netcdf sgpgramstddrC1.a0.20001003.130018 { dimensions: time = UNLIMITED ; // (30053 currently) channel = 7 ; index = 6 ; variables: int base_time ; base_time:string = "3-Oct-2000,12:50:24 GMT" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2000-10-03 12:50:24 0:00" ; short tddr(time, channel) ; tddr:long_name = "Total Direct Diffuse Radiation" ; tddr:units = "counts" ; tddr:resolution = "1" ; tddr:field_index = "1" ; tddr:Explanation_of_channel_1 = "10nm bandpass centered at .500 microns" ; tddr:Explanation_of_channel_2 = "10nm bandpass centered at .862 microns" ; tddr:Explanation_of_channel_3 = "10nm bandpass centered at 1.064 microns" ; tddr:Explanation_of_channel_4 = "10nm bandpass centered at 1.249 microns" ; tddr:Explanation_of_channel_5 = "10nm bandpass centered at 1.501 microns" ; tddr:Explanation_of_channel_6 = "10nm bandpass centered at 1.650 microns" ; tddr:Explanation_of_channel_7 = "10nm bandpass centered at 1.751 microns" ; short tddr_tec_temp(time) ; tddr_tec_temp:long_name = "TDDR Thermal Electric Cooler Temperature" ; tddr_tec_temp:units = "counts" ; tddr_tec_temp:resolution = "1" ; tddr_tec_temp:field_index = "2" ; short tddr_ring_encoder(time) ; tddr_ring_encoder:long_name = "TDDR Shadow Ring Encoder" ; tddr_ring_encoder:units = "counts" ; tddr_ring_encoder:resolution = "1" ; tddr_ring_encoder:field_index = "3" ; short avg_tec_temp(time) ; avg_tec_temp:long_name = "Five Second Moving Average TEC Temperature" ; avg_tec_temp:units = "counts" ; avg_tec_temp:resolution = "1" ; avg_tec_temp:field_index = "4" ; short motor(time) ; motor:long_name = "Chopper Motor Controller Flag" ; motor:units = "unitless" ; motor:resolution = "1" ; motor:field_index = "5" ; motor:value_0 = "value of 0 indicates motor is off" ; motor:value_1 = "value of 1 indicates motor is on" ; short gain(time) ; gain:long_name = "TDDR Gain Setting Flag" ; gain:units = "unitless" ; gain:resolution = "1" ; gain:field_index = "6" ; gain:value_0 = "value of 0 indicates TDDR gain setting is low" ; gain:value_1 = "value of 1 indicates TDDR gain setting is high" ; short cover(time) ; cover:long_name = "Is Cover Installed Flag" ; cover:units = "unitless" ; cover:resolution = "1" ; cover:field_index = "7" ; cover:value_0 = "value of 0 indicates the cover is removed" ; cover:value_1 = "value of 1 indicates the cover is installed" ; short blower(time) ; blower:long_name = "Dome Blower System Flag" ; blower:units = "unitless" ; blower:resolution = "1" ; blower:field_index = "8" ; blower:value_0 = "value of 0 indicates Dome Blower not functioning" ; blower:value_1 = "value of 1 indicates Dome Blower is functioning" ; float system_temp(time, index) ; system_temp:long_name = "System Temperatures" ; system_temp:units = "degC" ; system_temp:resolution = "0.1" ; system_temp:field_index = "9" ; float lat ; lat:long_name = "north latitude" ; lat:units = "degrees" ; lat:valid_range = -90.f, 90.f ; float lon ; lon:long_name = "east longitude" ; lon:units = "degrees" ; lon:valid_range = -180.f, 180.f ; float alt ; alt:long_name = "altitude" ; alt:units = "meters above Mean Sea Level" ; // global attributes: :ingest-software = " grams_ingest.c,v 6.0 1999/07/04 21:43:26 sds Release6_0 $" ; :proc-level = "a0" ; :input-source = "grams1:/data/raw/gramsC1/in/tddr2_20001003_125024.dat" ; :site-id = "sgp" ; :facility-id = "C1 : Central_Facility" ; :sds-mode = "production" ; :sample-int = "10Hz" ; :averaging-int = "None." ; :serial-number = " " ; :missing-data = "N/A" ; :comment = "Fields with units = \"counts\" are 1 part in 4096" ; :field_indices = "Each field contains an attribute named \"field_index\".\n", "This index is unique to each field and contains a value\n", "from 1 to N (where N is the number of fields in platform)." ; :resolution_description = "The resolution field attributes refer to the number of significant\n", "digits relative to the decimal point that should be used in\n", "calculations. Using fewer digits might result in greater uncertainty;\n", "using a larger number of digits should have no effect and thus is\n", "unnecessary. However, analyses based on differences in values with\n", "a larger number of significant digits than indicated could lead to\n", "erroneous results or misleading scientific conclusions.\n", "\n", "resolution for lat= 0.001\n", "resolution for lon = 0.001\n", "resolution for alt = 1" ; :zeb_platform = "sgpgramstddrC1.a0" ; :history = "created by the Zebra DataStore library, 3-Oct-2000,14:41:48, $RCSfile: DFA_NetCDF.c,v $ $Revision: 3.52 $\n", "" ; }