netcdf sgpbsrnC1.a0.20010122.000000 { dimensions: time = UNLIMITED ; // (963 currently) variables: int base_time ; base_time:string = "21-Jan-2001,22:58:00 GMT" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2001-01-21 22:58:00 0:00" ; float vbat(time) ; vbat:long_name = "Average battery voltage" ; vbat:units = "V" ; vbat:resolution = "0.1" ; vbat:field_index = "1" ; float nip(time) ; nip:long_name = "Average pyrheliometer voltage" ; nip:units = "mV" ; nip:resolution = "0.01" ; nip:field_index = "2" ; float psp1(time) ; psp1:long_name = "Average shaded pyranometer voltage" ; psp1:units = "mV" ; psp1:resolution = "0.01" ; psp1:field_index = "3" ; float psp2(time) ; psp2:long_name = "Average unshaded pyranometer voltage" ; psp2:units = "mV" ; psp2:resolution = "0.01" ; psp2:field_index = "4" ; float psig(time) ; psig:long_name = "Average pyrgeometer thermopile voltage" ; psig:units = "mV" ; psig:resolution = "0.01" ; psig:field_index = "5" ; float ptcase(time) ; ptcase:long_name = "Average pyrgeometer case thermistor resistance" ; ptcase:units = "Ohms" ; ptcase:resolution = "0.1" ; ptcase:field_index = "6" ; float ptdome(time) ; ptdome:long_name = "Average pyrgeometer dome thermistor resistance" ; ptdome:units = "Ohms" ; ptdome:resolution = "0.1" ; ptdome:field_index = "7" ; float vref(time) ; vref:long_name = "Average reference voltage" ; vref:units = "mV" ; vref:resolution = "0.01" ; vref:field_index = "8" ; float snip(time) ; snip:long_name = "Standard deviation for pyrheliometer" ; snip:units = "mV" ; snip:resolution = "0.01" ; snip:field_index = "9" ; float spsp1(time) ; spsp1:long_name = "Standard deviation for shaded pyranometer" ; spsp1:units = "mV" ; spsp1:resolution = "0.01" ; spsp1:field_index = "10" ; float spsp2(time) ; spsp2:long_name = "Standard deviation for unshaded pyranometer" ; spsp2:units = "mV" ; spsp2:resolution = "0.01" ; spsp2:field_index = "11" ; float ssig(time) ; ssig:long_name = "Standard deviation for pyrgeometer thermopile" ; ssig:units = "mV" ; ssig:resolution = "0.01" ; ssig:field_index = "12" ; float stcase(time) ; stcase:long_name = "Standard deviation for pyrgeometer case thermistor resistance" ; stcase:units = "Ohms" ; stcase:resolution = "0.1" ; stcase:field_index = "13" ; float stdome(time) ; stdome:long_name = "Standard deviation for pyrgeometer dome thermistor resistance" ; stdome:units = "Ohms" ; stdome:resolution = "0.1" ; stdome:field_index = "14" ; float svref(time) ; svref:long_name = "Standard deviation for reference" ; svref:units = "mV" ; svref:resolution = "0.01" ; svref:field_index = "15" ; float lat ; lat:long_name = "north latitude" ; lat:units = "degrees" ; lat:valid_range = -90.f, 90.f ; float lon ; lon:long_name = "east longitude" ; lon:units = "degrees" ; lon:valid_range = -180.f, 180.f ; float alt ; alt:long_name = "altitude" ; alt:units = "meters above Mean Sea Level" ; // global attributes: :ingest-software = " bsrn_ingest.c,v 6.0 1999/07/04 21:43:16 sds Release6_0 $" ; :proc-level = "a0" ; :input-source = "bsrn1:/data/raw/bsrnC1/in/bsrn1.980121738.icm" ; :site-id = "sgp" ; :facility-id = "C1 : Central_Facility" ; :sds-mode = "production" ; :sample-int = "1 second" ; :averaging-int = "60 seconds" ; :serial-number = "BSRN1\n", "PYRANOMETER(Unshaded): 31096F3\n", "PYRANOMETER(Shaded): 30953F3\n", "PYRGEOMETER(Shaded): 30687F3\n", "PYRHELIOMETER: 30721E6\n", "" ; :missing-data = "N/A" ; :comment = "The time assigned to each data point indicates the end of any\n", "period of averaging of the geophysical data.\n", "\n", "Altitude is in meters above Mean Sea Level" ; :field_indices = "Each field contains an attribute named \"field_index\".\n", "This index is unique to each field and contains a value\n", "from 1 to N (where N is the number of fields in platform)." ; :resolution_description = "The resolution field attributes refer to the number of significant\n", "digits relative to the decimal point that should be used in\n", "calculations. Using fewer digits might result in greater uncertainty;\n", "using a larger number of digits should have no effect and thus is\n", "unnecessary. However, analyses based on differences in values with\n", "a larger number of significant digits than indicated could lead to\n", "erroneous results or misleading scientific conclusions.\n", "\n", "resolution for lat= 0.001\n", "resolution for lon = 0.001\n", "resolution for alt = 1" ; :calib-coeff = "PYRANOMETER(Unshaded):8.933 \n", "PYRANOMETER(Shaded):8.454\n", "PYRGEOMETER(Shaded): 3.76\n", "PYRHELIOMETER:8.608 \n", "" ; :calib-date = "PYRANOMETER(Unshaded): 07/28/00\n", "PYRANOMETER(Shaded): 07/28/00\n", "PYRGEOMETER(Shaded): N/A.\n", "PYRHELIOMETER: 07/28/00\n", "" ; :sensor_heights = "The sensors are all at 1.5 meters, +/- 0.25 meters." ; :zeb_platform = "sgpbsrnC1.a0" ; :history = "created by the Zebra DataStore library, 22-Jan-2001,0:14:17, $RCSfile: DFA_NetCDF.c,v $ $Revision: 3.52 $\n", "" ; }