netcdf sgpaoscpcfS01.a1.20160613.000000 { dimensions: time = UNLIMITED ; // (64796 currently) variables: int base_time ; base_time:string = "2016-06-13 00:00:00 0:00" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; base_time:ancillary_variables = "time_offset" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2016-06-13 00:00:00 0:00" ; time_offset:ancillary_variables = "base_time" ; double time(time) ; time:long_name = "Time offset from midnight" ; time:units = "seconds since 2016-06-13 00:00:00 0:00" ; time:standard_name = "time" ; float concentration(time) ; concentration:long_name = "Particle concentration" ; concentration:units = "1/cm^3" ; concentration:missing_value = -9999.f ; float saturation_temp(time) ; saturation_temp:long_name = "Saturation temperature" ; saturation_temp:units = "degC" ; saturation_temp:missing_value = -9999.f ; float condensation_temp(time) ; condensation_temp:long_name = "Condensation temperature" ; condensation_temp:units = "degC" ; condensation_temp:missing_value = -9999.f ; float optics_temp(time) ; optics_temp:long_name = "Optics temperature" ; optics_temp:units = "degC" ; optics_temp:missing_value = -9999.f ; float cabinet_temp(time) ; cabinet_temp:long_name = "Cabinet temperature" ; cabinet_temp:units = "degC" ; cabinet_temp:missing_value = -9999.f ; float ambient_pressure(time) ; ambient_pressure:long_name = "Ambient pressure" ; ambient_pressure:units = "kPa" ; ambient_pressure:missing_value = -9999.f ; float orifice_pressure(time) ; orifice_pressure:long_name = "Orifice pressure" ; orifice_pressure:units = "kPa" ; orifice_pressure:missing_value = -9999.f ; float nozzle_pressure(time) ; nozzle_pressure:long_name = "Nozzle pressure" ; nozzle_pressure:units = "kPa" ; nozzle_pressure:missing_value = -9999.f ; float laser_current(time) ; laser_current:long_name = "Laser current" ; laser_current:units = "mA" ; laser_current:missing_value = -9999.f ; int liquid_level(time) ; liquid_level:long_name = "Liquid level" ; liquid_level:units = "unitless" ; liquid_level:missing_value = -9999 ; liquid_level:flag_values = 0, 1 ; liquid_level:flag_meanings = "not_full full" ; float fraction_full(time) ; fraction_full:long_name = "Liquid fraction available" ; fraction_full:units = "unitless" ; fraction_full:missing_value = -9999.f ; int dilution_valve_position(time) ; dilution_valve_position:long_name = "Dilution flow valve position" ; dilution_valve_position:units = "unitless" ; dilution_valve_position:missing_value = -9999 ; dilution_valve_position:flag_values = -1, 0, 1 ; dilution_valve_position:flag_meanings = "error closed open" ; float dilution_flow_setpoint(time) ; dilution_flow_setpoint:long_name = "Flow setpoint" ; dilution_flow_setpoint:units = "sccm" ; dilution_flow_setpoint:missing_value = -9999.f ; float dilution_flow_reading(time) ; dilution_flow_reading:long_name = "Flow read" ; dilution_flow_reading:units = "sccm" ; dilution_flow_reading:missing_value = -9999.f ; float lat ; lat:long_name = "North latitude" ; lat:units = "degree_N" ; lat:valid_min = -90.f ; lat:valid_max = 90.f ; lat:standard_name = "latitude" ; float lon ; lon:long_name = "East longitude" ; lon:units = "degree_E" ; lon:valid_min = -180.f ; lon:valid_max = 180.f ; lon:standard_name = "longitude" ; float alt ; alt:long_name = "Altitude above mean sea level" ; alt:units = "m" ; alt:standard_name = "altitude" ; // global attributes: :command_line = "aos_ingest -n aoscpcf -s sgp -f S01" ; :Conventions = "ARM-1.0" ; :process_version = "ingest-aos-14.17-0.el6" ; :dod_version = "aoscpcf-a1-2.3" ; :site_id = "sgp" ; :facility_id = "S01" ; :platform_id = "aoscpcf" ; :data_level = "a1" ; :location_description = "Southern Great Plains (SGP), Lamont, Oklahoma" ; :datastream = "sgpaoscpcfS01.a1" ; :input_source = "/data/collection/sgp/sgpaoscpcfS01.00/sgpaosS01.cpc3772.01s.00.20160613.000000.raw.tsv" ; :sampling_interval = "1 second" ; :averaging_interval = "not averaged" ; :serial_number = "not available" ; :CPC_Instrument_Description = "3772 Condensation Particle Counter, with dilution flow" ; :Instrument_Manufacturer = "TSI, Inc." ; :history = "created by user dsmgr on machine ruby at 2016-06-13 01:26:03, using ingest-aos-14.17-0.el6" ; }