netcdf mosaoscoM1.a1.20201001.000000 { dimensions: time = UNLIMITED ; // (53501 currently) variables: int base_time ; base_time:string = "2020-10-01 00:00:00 0:00" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; base_time:ancillary_variables = "time_offset" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2020-10-01 00:00:00 0:00" ; time_offset:ancillary_variables = "base_time" ; double time(time) ; time:long_name = "Time offset from midnight" ; time:units = "seconds since 2020-10-01 00:00:00 0:00" ; float co(time) ; co:long_name = "Carbon monoxide (CO) mixing ratio calculated with nominal sensitivity correction" ; co:units = "ppmv" ; co:missing_value = -9999.f ; float n2o(time) ; n2o:long_name = "Nitrous oxide (N2O) mixing ratio calculated with nominal sensitivity correction" ; n2o:units = "ppmv" ; n2o:missing_value = -9999.f ; float h2o(time) ; h2o:long_name = "Water vapor mixing ratio calculated with nominal sensitivity correction" ; h2o:units = "ppmv" ; h2o:missing_value = -9999.f ; float co_dry(time) ; co_dry:long_name = "Carbon monoxide (CO) mixing ratio corrected for water vapor concentration and calculated with nominal sensitivity correction" ; co_dry:units = "ppmv" ; co_dry:missing_value = -9999.f ; float n2o_dry(time) ; n2o_dry:long_name = "Nitrous oxide (N2O) mixing ratio corrected for water vapor concentration and calculated with nominal sensitivity correction" ; n2o_dry:units = "ppmv" ; n2o_dry:missing_value = -9999.f ; float gas_pressure(time) ; gas_pressure:long_name = "Cell sample pressure" ; gas_pressure:units = "torr" ; gas_pressure:missing_value = -9999.f ; float gas_temperature(time) ; gas_temperature:long_name = "Cell sample temperature" ; gas_temperature:units = "degC" ; gas_temperature:missing_value = -9999.f ; float ambient_temperature(time) ; ambient_temperature:long_name = "Ambient temperature of instrument" ; ambient_temperature:units = "degC" ; ambient_temperature:missing_value = -9999.f ; float set_point_for_MFC_1(time) ; set_point_for_MFC_1:long_name = "Set point for mass flow controller 1" ; set_point_for_MFC_1:units = "cm^3/min" ; set_point_for_MFC_1:flow_type = "mass flow" ; set_point_for_MFC_1:reference = "volume of mass flow corresponding to 0 deg C, 1013.25 hPa" ; set_point_for_MFC_1:missing_value = -9999.f ; set_point_for_MFC_1:comment = "This MFC is used along with MFC2 to control airflow to the first series of nafion columns to precondition the sample stream." ; float mass_flow_through_MFC_1(time) ; mass_flow_through_MFC_1:long_name = "Actual mass flow through mass flow controller 1" ; mass_flow_through_MFC_1:units = "cm^3/min" ; mass_flow_through_MFC_1:flow_type = "mass flow" ; mass_flow_through_MFC_1:reference = "volume of mass flow corresponding to 0 deg C, 1013.25 hPa" ; mass_flow_through_MFC_1:missing_value = -9999.f ; int valve_position_MFC_1(time) ; valve_position_MFC_1:long_name = "Valve position for mass flow controller 1" ; valve_position_MFC_1:units = "unitless" ; valve_position_MFC_1:missing_value = -9999 ; valve_position_MFC_1:flag_values = 0, 1, -1 ; valve_position_MFC_1:flag_meanings = "open closed error" ; float set_point_for_MFC_2(time) ; set_point_for_MFC_2:long_name = "Set point for mass flow controller 2" ; set_point_for_MFC_2:units = "cm^3/min" ; set_point_for_MFC_2:flow_type = "mass flow" ; set_point_for_MFC_2:reference = "volume of mass flow corresponding to 0 deg C, 1013.25 hPa" ; set_point_for_MFC_2:missing_value = -9999.f ; float mass_flow_through_MFC_2(time) ; mass_flow_through_MFC_2:long_name = "Actual mass flow through mass flow controller 2" ; mass_flow_through_MFC_2:units = "cm^3/min" ; mass_flow_through_MFC_2:flow_type = "mass flow" ; mass_flow_through_MFC_2:reference = "volume of mass flow corresponding to 0 deg C, 1013.25 hPa" ; mass_flow_through_MFC_2:missing_value = -9999.f ; int valve_position_MFC_2(time) ; valve_position_MFC_2:long_name = "Valve position mass flow controller 2" ; valve_position_MFC_2:units = "unitless" ; valve_position_MFC_2:missing_value = -9999 ; valve_position_MFC_2:flag_values = 0, 1, -1 ; valve_position_MFC_2:flag_meanings = "open closed error" ; float lat ; lat:long_name = "North latitude" ; lat:units = "degree_N" ; lat:valid_min = -90.f ; lat:valid_max = 90.f ; lat:standard_name = "latitude" ; float lon ; lon:long_name = "East longitude" ; lon:units = "degree_E" ; lon:valid_min = -180.f ; lon:valid_max = 180.f ; lon:standard_name = "longitude" ; float alt ; alt:long_name = "Altitude above mean sea level" ; alt:units = "m" ; alt:standard_name = "altitude" ; // global attributes: :command_line = "aosco_ingest -s mos -f M1 -DR" ; :Conventions = "ARM-1.2" ; :process_version = "ingest-aosco-1.2-4.el7" ; :dod_version = "aosco-a1-3.0" ; :site_id = "mos" ; :platform_id = "aosco" ; :facility_id = "M1" ; :data_level = "a1" ; :location_description = "Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) , Research Vessel PolarStern" ; :input_source = "/data/collection/mos/mosaoscoM1.00/mosaosM1.co.01s.00.20201001.000000.raw.tsv" ; :sampling_interval = "1 second" ; :averaging_interval = "not averaged" ; :datastream = "mosaoscoM1.a1" ; :CO_Instrument_Description = "LGR N2O_CO 908-0014-0000" ; :serial_number = "10-0004/WD59461" ; :mentor_name = "N/A" ; :mentor_affiliation = "N/A" ; :doi = "10.5439/1351064" ; :history = "created by user dsmgr on machine adc-procnode2 at 2021-09-22 20:19:02, using ingest-aosco-1.2-4.el7" ; }