netcdf houtbscpcS3.b1.20220914.210000 { dimensions: time = UNLIMITED ; // (1801 currently) num_cpc = 1 ; variables: int base_time ; base_time:string = "2022-09-14 00:00:00 0:00" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; base_time:ancillary_variables = "time_offset" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2022-09-14 00:00:00 0:00" ; time_offset:ancillary_variables = "base_time" ; double time(time) ; time:long_name = "Time offset from midnight" ; time:units = "seconds since 2022-09-14 00:00:00 0:00" ; time:calendar = "gregorian" ; time:standard_name = "time" ; float wind_direction(time, num_cpc) ; wind_direction:long_name = "Wind direction from iMet sensor" ; wind_direction:units = "degree" ; wind_direction:valid_min = 0.f ; wind_direction:valid_max = 360.f ; wind_direction:missing_value = -9999.f ; wind_direction:standard_name = "wind_from_direction" ; wind_direction:ancillary_variables = "qc_wind_direction" ; int qc_wind_direction(time, num_cpc) ; qc_wind_direction:long_name = "Quality check results on field: Wind direction from iMet sensor" ; qc_wind_direction:units = "1" ; qc_wind_direction:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_wind_direction:flag_method = "bit" ; qc_wind_direction:bit_1_description = "Value is equal to missing_value." ; qc_wind_direction:bit_1_assessment = "Bad" ; qc_wind_direction:bit_2_description = "Value is less than valid_min." ; qc_wind_direction:bit_2_assessment = "Bad" ; qc_wind_direction:bit_3_description = "Value is greater than valid_max." ; qc_wind_direction:bit_3_assessment = "Bad" ; float wind_speed(time, num_cpc) ; wind_speed:long_name = "Wind speed from iMet sensor" ; wind_speed:units = "m/s" ; wind_speed:valid_min = 0.f ; wind_speed:valid_max = 15.f ; wind_speed:missing_value = -9999.f ; wind_speed:standard_name = "wind_speed" ; wind_speed:ancillary_variables = "qc_wind_speed" ; int qc_wind_speed(time, num_cpc) ; qc_wind_speed:long_name = "Quality check results on field: Wind speed from iMet sensor" ; qc_wind_speed:units = "1" ; qc_wind_speed:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_wind_speed:flag_method = "bit" ; qc_wind_speed:bit_1_description = "Value is equal to missing_value." ; qc_wind_speed:bit_1_assessment = "Bad" ; qc_wind_speed:bit_2_description = "Value is less than valid_min." ; qc_wind_speed:bit_2_assessment = "Bad" ; qc_wind_speed:bit_3_description = "Value is greater than valid_max." ; qc_wind_speed:bit_3_assessment = "Bad" ; float temperature(time, num_cpc) ; temperature:long_name = "Temperature from iMet sensor" ; temperature:units = "degC" ; temperature:valid_min = -95.f ; temperature:valid_max = 50.f ; temperature:missing_value = -9999.f ; temperature:standard_name = "air_temperature" ; temperature:ancillary_variables = "qc_temperature" ; int qc_temperature(time, num_cpc) ; qc_temperature:long_name = "Quality check results on field: Temperature from iMet sensor" ; qc_temperature:units = "1" ; qc_temperature:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_temperature:flag_method = "bit" ; qc_temperature:bit_1_description = "Value is equal to missing_value." ; qc_temperature:bit_1_assessment = "Bad" ; qc_temperature:bit_2_description = "Value is less than valid_min." ; qc_temperature:bit_2_assessment = "Bad" ; qc_temperature:bit_3_description = "Value is greater than valid_max." ; qc_temperature:bit_3_assessment = "Bad" ; float relative_humidity(time, num_cpc) ; relative_humidity:long_name = "Relative humidity from iMet sensor" ; relative_humidity:units = "%" ; relative_humidity:valid_min = 0.f ; relative_humidity:valid_max = 105.f ; relative_humidity:missing_value = -9999.f ; relative_humidity:standard_name = "relative_humidity" ; relative_humidity:ancillary_variables = "qc_relative_humidity" ; int qc_relative_humidity(time, num_cpc) ; qc_relative_humidity:long_name = "Quality check results on field: Relative humidity from iMet sensor" ; qc_relative_humidity:units = "1" ; qc_relative_humidity:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_relative_humidity:flag_method = "bit" ; qc_relative_humidity:bit_1_description = "Value is equal to missing_value." ; qc_relative_humidity:bit_1_assessment = "Bad" ; qc_relative_humidity:bit_2_description = "Value is less than valid_min." ; qc_relative_humidity:bit_2_assessment = "Bad" ; qc_relative_humidity:bit_3_description = "Value is greater than valid_max." ; qc_relative_humidity:bit_3_assessment = "Bad" ; float imet_pressure(time, num_cpc) ; imet_pressure:long_name = "Pressure from iMet sensor" ; imet_pressure:units = "hPa" ; imet_pressure:valid_min = 10.f ; imet_pressure:valid_max = 1200.f ; imet_pressure:missing_value = -9999.f ; imet_pressure:standard_name = "air_pressure" ; imet_pressure:ancillary_variables = "qc_imet_pressure" ; int qc_imet_pressure(time, num_cpc) ; qc_imet_pressure:long_name = "Quality check results on field: Pressure from iMet sensor" ; qc_imet_pressure:units = "1" ; qc_imet_pressure:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_imet_pressure:flag_method = "bit" ; qc_imet_pressure:bit_1_description = "Value is equal to missing_value." ; qc_imet_pressure:bit_1_assessment = "Bad" ; qc_imet_pressure:bit_2_description = "Value is less than valid_min." ; qc_imet_pressure:bit_2_assessment = "Bad" ; qc_imet_pressure:bit_3_description = "Value is greater than valid_max." ; qc_imet_pressure:bit_3_assessment = "Bad" ; float gps_pressure(time, num_cpc) ; gps_pressure:long_name = "GPS pressure from iMet sensor" ; gps_pressure:units = "hPa" ; gps_pressure:valid_min = 10.f ; gps_pressure:valid_max = 1200.f ; gps_pressure:missing_value = -9999.f ; gps_pressure:standard_name = "air_pressure" ; gps_pressure:ancillary_variables = "qc_gps_pressure" ; int qc_gps_pressure(time, num_cpc) ; qc_gps_pressure:long_name = "Quality check results on field: GPS pressure from iMet sensor" ; qc_gps_pressure:units = "1" ; qc_gps_pressure:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_gps_pressure:flag_method = "bit" ; qc_gps_pressure:bit_1_description = "Value is equal to missing_value." ; qc_gps_pressure:bit_1_assessment = "Bad" ; qc_gps_pressure:bit_2_description = "Value is less than valid_min." ; qc_gps_pressure:bit_2_assessment = "Bad" ; qc_gps_pressure:bit_3_description = "Value is greater than valid_max." ; qc_gps_pressure:bit_3_assessment = "Bad" ; float total_concentration(time, num_cpc) ; total_concentration:long_name = "Total number concentration from CPC for the aerosol particles larger than 10 nm" ; total_concentration:units = "1/cm^3" ; total_concentration:valid_min = 0.f ; total_concentration:valid_max = 20000.f ; total_concentration:missing_value = -9999.f ; total_concentration:standard_name = "number_concentration_of_ambient_aerosol_in_air" ; total_concentration:ancillary_variables = "qc_total_concentration" ; int qc_total_concentration(time, num_cpc) ; qc_total_concentration:long_name = "Quality check results on field: Total number concentration from CPC for the aerosol particles larger than 10 nm" ; qc_total_concentration:units = "1" ; qc_total_concentration:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_total_concentration:flag_method = "bit" ; qc_total_concentration:bit_1_description = "Value is equal to missing_value." ; qc_total_concentration:bit_1_assessment = "Bad" ; qc_total_concentration:bit_2_description = "Value is less than valid_min." ; qc_total_concentration:bit_2_assessment = "Bad" ; qc_total_concentration:bit_3_description = "Value is greater than valid_max." ; qc_total_concentration:bit_3_assessment = "Bad" ; float lat(time, num_cpc) ; lat:long_name = "North latitude from iMet sensor" ; lat:units = "degree_N" ; lat:valid_min = -90.f ; lat:valid_max = 90.f ; lat:missing_value = -9999.f ; lat:standard_name = "latitude" ; float lon(time, num_cpc) ; lon:long_name = "East longitude from iMet sensor" ; lon:units = "degree_E" ; lon:valid_min = -180.f ; lon:valid_max = 180.f ; lon:missing_value = -9999.f ; lon:standard_name = "longitude" ; float alt(time, num_cpc) ; alt:long_name = "Altitude above mean sea level from iMet sensor" ; alt:units = "m" ; alt:missing_value = -9999.f ; alt:standard_name = "altitude" ; // global attributes: :command_line = "tbscpc_ingest -s hou -f S3" ; :Conventions = "ARM-1.2" ; :process_version = "ingest-tbscpc-2.0-0.el7" ; :dod_version = "tbscpc-b1-2.0" ; :input_source = "/data/collection/hou/houtbscpcS3.01/hou.s3.tbs.cpc.20220914.210000.txt" ; :site_id = "hou" ; :platform_id = "tbscpc" ; :facility_id = "S3" ; :data_level = "b1" ; :location_description = "Tracking Aerosol Convection Interactions Experiment (TRACER), Damon, Texas" ; :datastream = "houtbscpcS3.b1" ; :doi = "10.5439/1582131" ; :history = "created by user dsmgr on machine flint at 2022-09-16 01:47:01, using ingest-tbscpc-2.0-0.el7" ; }