netcdf gucaoscpcf1mM1.b1.20211016.000030 { dimensions: time = UNLIMITED ; // (840 currently) bound = 2 ; variables: int base_time ; base_time:string = "2021-10-16 00:00:00 0:00" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; base_time:ancillary_variables = "time_offset" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2021-10-16 00:00:00 0:00" ; time_offset:ancillary_variables = "base_time" ; double time(time) ; time:long_name = "Time offset from midnight" ; time:units = "seconds since 2021-10-16 00:00:00 0:00" ; time:bounds = "time_bounds" ; time:standard_name = "time" ; double time_bounds(time, bound) ; time_bounds:long_name = "Time cell bounds" ; time_bounds:bound_offsets = -30., 30. ; float concentration(time) ; concentration:long_name = "Particle concentration" ; concentration:units = "1/cm^3" ; concentration:valid_min = 50.f ; concentration:valid_max = 10000.f ; concentration:missing_value = -9999.f ; concentration:ancillary_variables = "qc_concentration" ; int qc_concentration(time) ; qc_concentration:long_name = "Quality check results on field: Particle concentration" ; qc_concentration:units = "1" ; qc_concentration:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_concentration:flag_method = "bit" ; qc_concentration:bit_1_description = "Value is equal to missing_value." ; qc_concentration:bit_1_assessment = "Bad" ; qc_concentration:bit_2_description = "Value is less than the valid_min." ; qc_concentration:bit_2_assessment = "Bad" ; qc_concentration:bit_3_description = "Value is greater than the valid_max." ; qc_concentration:bit_3_assessment = "Bad" ; qc_concentration:bit_4_description = "Transformation could not finish (all values bad or outside range, etc.), value set to missing_value." ; qc_concentration:bit_4_assessment = "Bad" ; qc_concentration:bit_5_description = "Transformation resulted in an indeterminate outcome." ; qc_concentration:bit_5_assessment = "Indeterminate" ; float saturation_temp(time) ; saturation_temp:long_name = "Saturation temperature" ; saturation_temp:units = "degC" ; saturation_temp:missing_value = -9999.f ; float condensation_temp(time) ; condensation_temp:long_name = "Condensation temperature" ; condensation_temp:units = "degC" ; condensation_temp:missing_value = -9999.f ; float optics_temp(time) ; optics_temp:long_name = "Optics temperature" ; optics_temp:units = "degC" ; optics_temp:missing_value = -9999.f ; float cabinet_temp(time) ; cabinet_temp:long_name = "Cabinet temperature" ; cabinet_temp:units = "degC" ; cabinet_temp:missing_value = -9999.f ; float ambient_pressure(time) ; ambient_pressure:long_name = "Ambient pressure" ; ambient_pressure:units = "kPa" ; ambient_pressure:missing_value = -9999.f ; float orifice_pressure(time) ; orifice_pressure:long_name = "Orifice pressure" ; orifice_pressure:units = "kPa" ; orifice_pressure:missing_value = -9999.f ; float nozzle_pressure(time) ; nozzle_pressure:long_name = "Nozzle pressure" ; nozzle_pressure:units = "kPa" ; nozzle_pressure:missing_value = -9999.f ; float laser_current(time) ; laser_current:long_name = "Laser current" ; laser_current:units = "mA" ; laser_current:missing_value = -9999.f ; int liquid_level(time) ; liquid_level:long_name = "Liquid level" ; liquid_level:units = "1" ; liquid_level:missing_value = -9999 ; liquid_level:flag_values = 0, 1 ; liquid_level:flag_meanings = "not_full full" ; float fraction_full(time) ; fraction_full:long_name = "Liquid fraction available" ; fraction_full:units = "1" ; fraction_full:missing_value = -9999.f ; float dilution_correction_factor(time) ; dilution_correction_factor:long_name = "Dilution correction factor" ; dilution_correction_factor:units = "1" ; dilution_correction_factor:missing_value = -9999.f ; float lat ; lat:long_name = "North latitude" ; lat:units = "degree_N" ; lat:valid_min = -90.f ; lat:valid_max = 90.f ; lat:standard_name = "latitude" ; float lon ; lon:long_name = "East longitude" ; lon:units = "degree_E" ; lon:valid_min = -180.f ; lon:valid_max = 180.f ; lon:standard_name = "longitude" ; float alt ; alt:long_name = "Altitude above mean sea level" ; alt:units = "m" ; alt:standard_name = "altitude" ; // global attributes: :command_line = "aoscpcf1m -s guc -f M1 -RD -b 20210825 -e 20211017" ; :Conventions = "ARM-1.2" ; :process_version = "ingest-aoscpcf1m-1.1-0.el7" ; :dod_version = "aoscpcf1m-b1-1.0" ; :site_id = "guc" ; :platform_id = "aoscpcf1m" ; :facility_id = "M1" ; :data_level = "b1" ; :location_description = "Surface Atmosphere Integrated Field Laboratory (SAIL), Mt Crested Butte, Colorado" ; :datastream = "gucaoscpcf1mM1.b1" ; :input_datastreams = "gucaoscpcfM1.b1 : 2.6 : 20211016.000000" ; :sampling_interval = "1 second" ; :averaging_interval = "1 minute" ; :CPC_Instrument_Description = "3772 Condensation Particle Counter, with dilution flow" ; :Instrument_Manufacturer = "TSI, Inc." ; :doi = "10.5439/1398277" ; :history = "created by user erwinmj on machine prod-proc5.adc.arm.gov at 2023-02-10 17:34:34, using ingest-aoscpcf1m-1.1-0.el7" ; }