netcdf enaaoscpcfC1.a1.20240501.000000 { dimensions: time = UNLIMITED ; // (86398 currently) variables: int base_time ; base_time:string = "2024-05-01 00:00:00 0:00" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; base_time:ancillary_variables = "time_offset" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2024-05-01 00:00:00 0:00" ; time_offset:ancillary_variables = "base_time" ; double time(time) ; time:long_name = "Time offset from midnight" ; time:units = "seconds since 2024-05-01 00:00:00 0:00" ; time:standard_name = "time" ; float corrected_concentration(time) ; corrected_concentration:long_name = "Concentration adjusted using corrected_flow" ; corrected_concentration:units = "1/cm^3" ; corrected_concentration:missing_value = -9999.f ; float corrected_flow(time) ; corrected_flow:long_name = "Corrected flow rate" ; corrected_flow:units = "cc/min" ; corrected_flow:missing_value = -9999.f ; float raw_concentration(time) ; raw_concentration:long_name = "Raw particle concentration using uncorrected flow rate" ; raw_concentration:units = "1/cm^3" ; raw_concentration:missing_value = -9999.f ; float saturation_temp(time) ; saturation_temp:long_name = "Saturation temperature" ; saturation_temp:units = "degC" ; saturation_temp:missing_value = -9999.f ; float condensation_temp(time) ; condensation_temp:long_name = "Condensation temperature" ; condensation_temp:units = "degC" ; condensation_temp:missing_value = -9999.f ; float optics_temp(time) ; optics_temp:long_name = "Optics temperature" ; optics_temp:units = "degC" ; optics_temp:missing_value = -9999.f ; float cabinet_temp(time) ; cabinet_temp:long_name = "Cabinet temperature" ; cabinet_temp:units = "degC" ; cabinet_temp:missing_value = -9999.f ; float ambient_pressure(time) ; ambient_pressure:long_name = "Ambient pressure" ; ambient_pressure:units = "kPa" ; ambient_pressure:missing_value = -9999.f ; float orifice_pressure(time) ; orifice_pressure:long_name = "Orifice pressure" ; orifice_pressure:units = "kPa" ; orifice_pressure:missing_value = -9999.f ; float nozzle_pressure(time) ; nozzle_pressure:long_name = "Nozzle pressure" ; nozzle_pressure:units = "kPa" ; nozzle_pressure:missing_value = -9999.f ; float laser_current(time) ; laser_current:long_name = "Laser current" ; laser_current:units = "mA" ; laser_current:missing_value = -9999.f ; int liquid_level(time) ; liquid_level:long_name = "Liquid level" ; liquid_level:units = "1" ; liquid_level:missing_value = -9999 ; liquid_level:flag_values = 0, 1 ; liquid_level:flag_meanings = "not_full full" ; float fraction_full(time) ; fraction_full:long_name = "Liquid fraction available" ; fraction_full:units = "1" ; fraction_full:missing_value = -9999.f ; float analog_in_1(time) ; analog_in_1:long_name = "Analog input 1" ; analog_in_1:units = "V" ; analog_in_1:missing_value = -9999.f ; float analog_in_2(time) ; analog_in_2:long_name = "Analog input 2" ; analog_in_2:units = "V" ; analog_in_2:missing_value = -9999.f ; float pressure_drop(time) ; pressure_drop:long_name = "Flow rate pressure drop" ; pressure_drop:units = "kPa" ; pressure_drop:missing_value = -9999.f ; float cal_multiplier(time) ; cal_multiplier:long_name = "Calibration multiplier" ; cal_multiplier:units = "1" ; cal_multiplier:missing_value = -9999.f ; float cal_offset(time) ; cal_offset:long_name = "Calibration offset" ; cal_offset:units = "1" ; cal_offset:missing_value = -9999.f ; float lat ; lat:long_name = "North latitude" ; lat:units = "degree_N" ; lat:valid_min = -90.f ; lat:valid_max = 90.f ; lat:standard_name = "latitude" ; float lon ; lon:long_name = "East longitude" ; lon:units = "degree_E" ; lon:valid_min = -180.f ; lon:valid_max = 180.f ; lon:standard_name = "longitude" ; float alt ; alt:long_name = "Altitude above mean sea level" ; alt:units = "m" ; alt:standard_name = "altitude" ; // global attributes: :command_line = "aoscpcf_ingest -s ena -f C1" ; :Conventions = "ARM-1.2" ; :process_version = "ingest-aoscpcf-1.3-0.el7" ; :dod_version = "aoscpcf-a1-3.0" ; :input_source = "/data/collection/ena/enaaoscpcfC1.00/enaaoss1.cpc3772.01s.00.20240501.000000.raw.tsv" ; :site_id = "ena" ; :platform_id = "aoscpcf" ; :facility_id = "C1" ; :data_level = "a1" ; :location_description = "Eastern North Atlantic (ENA), Graciosa Island, Azores" ; :datastream = "enaaoscpcfC1.a1" ; :serial_number = "3772140501" ; :sampling_interval = "1 second" ; :cpc_instrument_description = "3772 Condensation Particle Counter, with dilution flow" ; :instrument_manufacturer = "TSI, Inc." ; :mentor_name = "Kuang" ; :mentor_affiliation = "BNL" ; :doi = "10.5439/1336393" ; :history = "created by user dsmgr on machine prod-proc3.adc.arm.gov at 2024-05-01 02:05:00, using ingest-aoscpcf-1.3-0.el7" ; }