netcdf coraafcpcfisoF1.b1.20181208.160602 { dimensions: time = UNLIMITED ; // (12273 currently) variables: int base_time ; base_time:string = "2018-12-08 00:00:00 0:00" ; base_time:long_name = "Base time in Epoch" ; base_time:units = "seconds since 1970-1-1 0:00:00 0:00" ; base_time:ancillary_variables = "time_offset" ; double time_offset(time) ; time_offset:long_name = "Time offset from base_time" ; time_offset:units = "seconds since 2018-12-08 00:00:00 0:00" ; time_offset:ancillary_variables = "base_time" ; double time(time) ; time:long_name = "Time offset from midnight" ; time:units = "seconds since 2018-12-08 00:00:00 0:00" ; time:standard_name = "time" ; float concentration(time) ; concentration:long_name = "Particle concentration" ; concentration:units = "1/cm^3" ; concentration:missing_value = -9999.f ; concentration:valid_min = 0.f ; concentration:valid_max = 50000.f ; concentration:ancillary_variables = "qc_concentration" ; int qc_concentration(time) ; qc_concentration:long_name = "Quality check results on field: Particle concentration" ; qc_concentration:units = "unitless" ; qc_concentration:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_concentration:concentration_max_warning = 50000.f ; qc_concentration:concentration_min_warning = 15000.f ; qc_concentration:nozzle_pressure_min_alarm = 0.75f ; qc_concentration:nozzle_pressure_min_warning = 1.5f ; qc_concentration:nozzle_pressure_max_warning = 3.5f ; qc_concentration:nozzle_pressure_max_alarm = 4.f ; qc_concentration:orifice_pressure_min_warning = 20.f ; qc_concentration:orifice_pressure_max_warning = 70.f ; qc_concentration:orifice_pressure_min_alarm = 18.f ; qc_concentration:orifice_pressure_max_alarm = 73.f ; qc_concentration:pressure_diff_max_warning = 0.528f ; qc_concentration:pressure_diff_max_alarm = 0.6f ; qc_concentration:sat_temp_min_alarm = 38.5f ; qc_concentration:sat_temp_max_alarm = 39.5f ; qc_concentration:cond_temp_min_alarm = 21.5f ; qc_concentration:cond_temp_max_alarm = 22.5f ; qc_concentration:optics_temp_min_alarm = 38.f ; qc_concentration:optics_temp_max_alarm = 42.f ; qc_concentration:laser_current_min_alarm = 35.f ; qc_concentration:cabinet_temp_min_alarm = 0.f ; qc_concentration:cabinet_temp_max_alarm = 45.f ; qc_concentration:ambient_pressure_min_alarm = 70.f ; qc_concentration:ambient_pressure_max_alarm = 110.f ; qc_concentration:flag_method = "bit" ; qc_concentration:bit_1_description = "Value is equal to missing_value." ; qc_concentration:bit_1_assessment = "Bad" ; qc_concentration:bit_2_description = "Value is less than the valid_min." ; qc_concentration:bit_2_assessment = "Bad" ; qc_concentration:bit_3_description = "Value is greater than the valid_max." ; qc_concentration:bit_3_assessment = "Bad" ; qc_concentration:bit_4_description = "Value is greater than concentration_min_warning AND value is less than concentration_max_warning" ; qc_concentration:bit_4_assessment = "Indeterminate" ; qc_concentration:bit_5_description = "nozzle_pressure < nozzle_pressure_min_warning OR nozzle_pressure > nozzle_pressure_max_warning" ; qc_concentration:bit_5_assessment = "Indeterminate" ; qc_concentration:bit_6_description = "nozzle_pressure < nozzle_pressure_min_alarm OR nozzle_pressure > nozzle_pressure_max_alarm" ; qc_concentration:bit_6_assessment = "Bad" ; qc_concentration:bit_7_description = "orifice_pressure < orifice_pressure_min_warning OR orifice_pressure > orifice_pressure_max_warning" ; qc_concentration:bit_7_assessment = "Indeterminate" ; qc_concentration:bit_8_description = "orifice_pressure < orifice_pressure_min_alarm OR orifice_pressure > orifice_pressure_max_alarm" ; qc_concentration:bit_8_assessment = "Bad" ; qc_concentration:bit_9_description = "saturation_temp < sat_temp_min_alarm OR saturation_temp > sat_temp_max_alarm" ; qc_concentration:bit_9_assessment = "Bad" ; qc_concentration:bit_10_description = "condensation_temp < cond_temp_min_alarm OR condensation_temp > cond_temp_max_alarm" ; qc_concentration:bit_10_assessment = "Bad" ; qc_concentration:bit_11_description = "optics_temp < optics_temp_min_alarm OR optics_temp > optics_temp_max_alarm" ; qc_concentration:bit_11_assessment = "Bad" ; qc_concentration:bit_12_description = "laser_current < laser_current_min_alarm" ; qc_concentration:bit_12_assessment = "Bad" ; qc_concentration:bit_13_description = "cabinet_temp < cabinet_temp_min_alarm OR cabinet_temp > cabinet_temp_max_alarm" ; qc_concentration:bit_13_assessment = "Bad" ; qc_concentration:bit_14_description = "ambient_pressure < ambient_pressure_min_alarm OR ambient_pressure > ambient_pressure_max_alarm" ; qc_concentration:bit_14_assessment = "Indeterminate" ; qc_concentration:bit_15_description = "(ambient_pressure - nozzle_pressure - orifice_pressure) / (ambient_pressure - nozzle_pressure) > pressure_diff_max_warning" ; qc_concentration:bit_15_assessment = "Indeterminate" ; qc_concentration:bit_16_description = "(ambient_pressure - nozzle_pressure - orifice_pressure) / (ambient_pressure - nozzle_pressure) >= pressure_diff_max_alarm" ; qc_concentration:bit_16_assessment = "Bad" ; float saturator_temperature(time) ; saturator_temperature:long_name = "Saturation temperature" ; saturator_temperature:units = "degC" ; saturator_temperature:missing_value = -9999.f ; float condenser_temperature(time) ; condenser_temperature:long_name = "Condensation temperature" ; condenser_temperature:units = "degC" ; condenser_temperature:missing_value = -9999.f ; float optics_temperature(time) ; optics_temperature:long_name = "Optics temperature" ; optics_temperature:units = "degC" ; optics_temperature:missing_value = -9999.f ; float cabinet_temperature(time) ; cabinet_temperature:long_name = "Cabinet temperature" ; cabinet_temperature:units = "degC" ; cabinet_temperature:missing_value = -9999.f ; float ambient_pressure(time) ; ambient_pressure:long_name = "Ambient pressure" ; ambient_pressure:units = "kPa" ; ambient_pressure:missing_value = -9999.f ; float orifice_pressure(time) ; orifice_pressure:long_name = "Orifice pressure" ; orifice_pressure:units = "kPa" ; orifice_pressure:missing_value = -9999.f ; float nozzle_pressure(time) ; nozzle_pressure:long_name = "Nozzle pressure" ; nozzle_pressure:units = "kPa" ; nozzle_pressure:missing_value = -9999.f ; float laser_current(time) ; laser_current:long_name = "Laser current" ; laser_current:units = "mA" ; laser_current:missing_value = -9999.f ; int liquid_level(time) ; liquid_level:long_name = "Liquid level" ; liquid_level:units = "unitless" ; liquid_level:missing_value = -9999 ; liquid_level:flag_values = 0, 1 ; liquid_level:flag_meanings = "not_full full" ; double lat(time) ; lat:long_name = "North latitude" ; lat:units = "degree_N" ; lat:valid_min = -33.5 ; lat:valid_max = -31. ; lat:missing_value = -9999. ; lat:standard_name = "latitude" ; lat:source = "coraafnavdsm10hzF1.a1:lat" ; lat:ancillary_variables = "qc_lat" ; int qc_lat(time) ; qc_lat:long_name = "Quality check results on field: North latitude" ; qc_lat:units = "unitless" ; qc_lat:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_lat:flag_method = "bit" ; qc_lat:bit_1_description = "Value is equal to missing_value." ; qc_lat:bit_1_assessment = "Bad" ; qc_lat:bit_2_description = "Value is less than the valid_min." ; qc_lat:bit_2_assessment = "Bad" ; qc_lat:bit_3_description = "Value is greater than the valid_max." ; qc_lat:bit_3_assessment = "Bad" ; double lon(time) ; lon:long_name = "East longitude" ; lon:units = "degree_E" ; lon:valid_min = -65.5 ; lon:valid_max = -63.5 ; lon:missing_value = -9999. ; lon:standard_name = "longitude" ; lon:source = "coraafnavdsm10hzF1.a1:lon" ; lon:ancillary_variables = "qc_lon" ; int qc_lon(time) ; qc_lon:long_name = "Quality check results on field: East longitude" ; qc_lon:units = "unitless" ; qc_lon:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_lon:flag_method = "bit" ; qc_lon:bit_1_description = "Value is equal to missing_value." ; qc_lon:bit_1_assessment = "Bad" ; qc_lon:bit_2_description = "Value is less than the valid_min." ; qc_lon:bit_2_assessment = "Bad" ; qc_lon:bit_3_description = "Value is greater than the valid_max." ; qc_lon:bit_3_assessment = "Bad" ; double alt(time) ; alt:long_name = "Altitude above mean sea level" ; alt:units = "m" ; alt:valid_min = 0. ; alt:valid_max = 8000. ; alt:missing_value = -9999. ; alt:standard_name = "altitude" ; alt:source = "coraafnavdsm10hzF1.a1:alt" ; alt:ancillary_variables = "qc_alt" ; int qc_alt(time) ; qc_alt:long_name = "Quality check results on field: Altitude above mean sea level" ; qc_alt:units = "unitless" ; qc_alt:description = "This field contains bit packed integer values, where each bit represents a QC test on the data. Non-zero bits indicate the QC condition given in the description for those bits; a value of 0 (no bits set) indicates the data has not failed any QC tests." ; qc_alt:flag_method = "bit" ; qc_alt:bit_1_description = "Value is equal to missing_value." ; qc_alt:bit_1_assessment = "Bad" ; qc_alt:bit_2_description = "Value is less than the valid_min." ; qc_alt:bit_2_assessment = "Bad" ; qc_alt:bit_3_description = "Value is greater than the valid_max." ; qc_alt:bit_3_assessment = "Bad" ; // global attributes: :command_line = "aafcpcfisocorr -s cor -f F1 -D" ; :Conventions = "ARM-1.2" ; :process_version = "ingest-aafcpcfisocorr-1.1-0.el7" ; :dod_version = "aafcpcfiso-b1-1.0" ; :input_source = "/data/collection/cor/coraafcpcfisoF1.00/20181208a.D.3772a.txt" ; :site_id = "cor" ; :platform_id = "aafcpcfiso" ; :facility_id = "F1" ; :data_level = "b1" ; :location_description = "Cloud, Aerosol, and Complex Terrain Interactions (CACTI), Gulfstream 159 (\"G1\") Aircraft" ; :datastream = "coraafcpcfisoF1.b1" ; :sampling_interval = "1 second" ; :cpc_instrument_description = "3772 Condensation Particle Counter, with dilution flow" ; :instrument_manufacturer = "TSI, Inc." ; :doi = "10.5439/1373109" ; :history = "created by user fparry on machine prod-proc3.adc.arm.gov at 2023-03-15 18:35:01, using ingest-aafcpcfisocorr-1.1-0.el7" ; }