DQR ID | Subject | Affected Data Streams | Data Quality Metric |
---|---|---|---|
D170413.1 | ENA/MWRP/C1 - Possible recalibration needed | enamwrpC1.b1 | Incorrect |
D140606.1 | ENA/MWRP/C1 - Radiometer not calibrated | enamwrpC1.b1 | Incorrect |
D150826.1 | ENA/MWRP/C1 - Intermittent data | enamwrpC1.b1 | Note |
D140905.2 | ENA/MWRP/C1 - Incorrect IRT readings | enamwrpC1.b1 | Incorrect |
D151020.3 | ENA/MWRP/C1 - Instrument removed for repairs | enamwrpC1.b1 | Missing |
D141212.1 | ENA/MWRP/C1 - Reprocessing Notice (RID 1261) | enamwrpC1.b1 | Note |
D140625.3 | ENA/MWRP/C1 - Bad calibration | enamwrpC1.b1 | Incorrect |
D140724.3 | ENA/MWRP/C1 - Reprocess: Bias in brightness temperatures | enamwrpC1.b1 | Suspect |
D150219.2 | ENA/MWRP/C1 - Reprocess: Calibration drift | enamwrpC1.b1 | Incorrect |
D150303.6 | ENA/MWRP/C1 - Occasional outages of surface T/RH readings | enamwrpC1.b1 | Suspect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2017-03-24 | 10:35:00 | 2017-04-21 | 14:59:59 | Incorrect |
Subject: | ENA/MWRP/C1 - Possible recalibration needed |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | The data appear to have incorrect calibration |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-03-01 | 00:00:00 | 2014-04-28 | 17:38:00 | Incorrect |
Subject: | ENA/MWRP/C1 - Radiometer not calibrated |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | The radiometer was not calibrated during this time. Data should be disregarded. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-07-03 | 00:00:00 | 2015-07-30 | 20:18:00 | Note |
Subject: | ENA/MWRP/C1 - Intermittent data |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | There are several data gaps in the data due to a change in the radiometer's hardware configuration. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-08-20 | 22:30:00 | 2014-08-25 | 13:30:00 | Incorrect |
Subject: | ENA/MWRP/C1 - Incorrect IRT readings |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | The infrared temperature readings are higher than those from the IRT and skyrad instruments. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-10-08 | 16:00:00 | 2017-03-24 | 11:00:00 | Missing |
Subject: | ENA/MWRP/C1 - Instrument removed for repairs |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | The instrument was sent to the vendor fore repairs |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-10-29 | 00:00:00 | 2014-11-24 | 15:38:00 | Note |
Subject: | ENA/MWRP/C1 - Reprocessing Notice (RID 1261) |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | See below for details of reprocessing that was completed on 20150309. Original DQR category: 3 (Yellow, Suspect). ----------------------------------------------------------- The radiometer's calibration appears unstable. The brightness temperatures are warmer than expected. Data need to be recalibrated. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-05-19 | 00:00:00 | 2014-06-04 | 14:59:00 | Incorrect |
Subject: | ENA/MWRP/C1 - Bad calibration |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | The radiometer was poorly calibrated following a power outage at the site. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-06-04 | 14:00:00 | 2014-07-24 | 19:34:59 | Suspect |
Subject: | ENA/MWRP/C1 - Reprocess: Bias in brightness temperatures |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | The brightness temperatures between 22.234 and 26.234 GHz show a bias of 1.7 to 3.6 degrees K. Data needs to be recalibrated. As a consequence the retrieved precipitable water vapor has a positive bias. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-02-26 | 00:00:00 | 2015-10-08 | 16:00:00 | Incorrect |
Subject: | ENA/MWRP/C1 - Reprocess: Calibration drift |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | The data are incorrect mostly because of fast drift in the calibration. Brightness temperatures become negative after 9/7/2015. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-04-24 | 02:00:00 | 2015-10-08 | 15:04:00 | Suspect |
Subject: | ENA/MWRP/C1 - Occasional outages of surface T/RH readings |
---|---|
Affected Datastreams: | enamwrpC1.b1 |
Description | Occasionally the surface temperature and relative humidity readings are not updated and the measurements appear flat for short times. The primary data are most likely not affected because the surface measurements are flatlined for short intervals when big changes are not expected. |
Measurements |
|