DQR ID | Subject | Affected Data Streams | Data Quality Metric |
---|---|---|---|
D150506.1 | MAO/SEBS/M1 - Surface Energy Balance Incorrect | maosebsM1.b1 | Incorrect |
D151203.6 | MAO/SEBS/M1 - Surface Energy Balance Incorrect. | maosebsM1.b1 | Incorrect |
D150427.3 | MAO/SEBS/M1 - Net Radiometer Measurements Incorrect | maosebsM1.b1 | Incorrect |
D150908.2 | MAO/SEBS/M1 - Incorrect values because a connector was corroded | maosebsM1.b1 | Incorrect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-04-21 | 15:00:00 | 2015-05-04 | 14:30:00 | Incorrect |
Subject: | MAO/SEBS/M1 - Surface Energy Balance Incorrect |
---|---|
Affected Datastreams: | maosebsM1.b1 |
Description | Soil Heat Flow 1 had a partially sliced cable, causing soil heat flow 1, average soil heat flow, and surface energy balance to be incorrect. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-10-08 | 12:00:00 | 2015-12-01 | 11:30:00 | Incorrect |
Subject: | MAO/SEBS/M1 - Surface Energy Balance Incorrect. |
---|---|
Affected Datastreams: | maosebsM1.b1 |
Description | Surface Energy Balance was incorrect while soil heat flow 1 was not working. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-04-14 | 21:00:00 | 2015-04-23 | 19:30:00 | Incorrect |
Subject: | MAO/SEBS/M1 - Net Radiometer Measurements Incorrect |
---|---|
Affected Datastreams: | maosebsM1.b1 |
Description | Corrosion in the net radiometer connector caused some measurements from the net radiometer to be incorrect. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-08-16 | 15:00:00 | 2015-09-03 | 18:00:00 | Incorrect |
Subject: | MAO/SEBS/M1 - Incorrect values because a connector was corroded |
---|---|
Affected Datastreams: | maosebsM1.b1 |
Description | Surface Energy Balance, Solar Shortwave Downwelling, Albedo, and Net Radiation were incorrect because a connector was corroded. |
Measurements |
|