DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D161122.2 | SGP/RADFLUXANAL/E19 - Reprocess: Incorrect set of SIRS coefficients | sgpradflux1longE19.c2 | Incorrect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/13/2007 | 0000 | 01/04/2008 | 2359 | Incorrect |
Subject: | SGP/RADFLUXANAL/E19 - Reprocess: Incorrect set of SIRS coefficients |
DataStreams: | sgpradflux1longE19.c2 |
Description: | Sometime on 10/13/2007 the SIRS data logger reverted to the old program used for the previous set of coefficients (i.e. Before the scheduled 09/13 shortwave instrument swap out). Differences in coefficients were such that the program change didn't result in easily discernible changes in the data. The long wave instruments were not affected. The SIRS data were reprocessed to apply the correct calibration coefficients for all shortwave measurements but the RADFLUX data have not been reprocessed. |
Measurements: | sgpradflux1longE19.c2:
|