DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D160205.14 | AWR/SEBS/S1 - No soil measurements during AWARE | awrsebsS1.b1 | Missing |
D160419.1 | AWR/SONDE/S1 - Reprocessed and Corrected: Station altitude set incorrectly | awrsondewnpnS1.b1 | Does not affect quality |
D160913.3 | AWR/CEIL/S1 - Reprocess: Incorrect averaging_inverval global attribute | awrceilS1.b1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/07/2015 | 0100 | 01/18/2016 | 1900 | Missing |
Subject: | AWR/SEBS/S1 - No soil measurements during AWARE |
DataStreams: | awrsebsS1.b1 |
Description: | This DQR serves as a note that the SEBS made no soil measurements during the AWARE campaign. Thus, select soil variables will be filled with missing values. |
Measurements: | awrsebsS1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/01/2015 | 0000 | 01/19/2016 | 0138 | Does not affect quality |
Subject: | AWR/SONDE/S1 - Reprocessed and Corrected: Station altitude set incorrectly |
DataStreams: | awrsondewnpnS1.b1 |
Description: | DATA REPROCESSED and CORRECTED: An incorrect station elevation was input into the raw data: Incorrect value is 1829.0 Correct value is 1803.5 The data were archived in October 2016. Please retrieve the reprocessed data for use in your analysis. ORIGINAL DQR CATEGORY: Red( Incorrect) REPROCESSED and CORRECTED DATA ARCHIVED:2016-10 REPROCESS IDENTIFICATION NUMBER: RID 1458 --------------------------------------------------- --- ORIGINAL DQR DESCRIPTION --- --------------------------------------------------- Station height is incorrect and needs to be corrected. Incorrect value is 1829.0 Correct value is 1803.5 |
Measurements: | awrsondewnpnS1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/03/2015 | 2107 | 01/17/2016 | 2359 | Does not affect quality |
Subject: | AWR/CEIL/S1 - Reprocess: Incorrect averaging_inverval global attribute |
DataStreams: | awrceilS1.b1 |
Description: | When the ceilometer software was changed from CT-View to CL-View, several firmware configuration changes were made to the model CT25K for consistency with the CL31 at other sites, including the data acquisition interval which was changed from 15 to 16 seconds. However, the global attribute "averaging_interval" in the ceil datastream was not changed. |
Measurements: | awrceilS1.b1:
|