DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D150206.1 | ACX/HSRL/M1 - Instrument down at times | acxhsrlM1.a1 | Suspect |
D150220.2 | ACX/S-TABLE/M1 - Instrument | acxrphtiltM1.a1, acxrphM1.00, acxrphcontrolM1.a1 | Missing |
D150302.11 | ACX/S-TABLE/M1 - Missing Data: Ship in Port | acxrphtiltM1.a1, acxrphM1.00, acxrphcontrolM1.a1 | Missing |
D150302.12 | ACX/CCN/CPC/HTDMA/NEPHELOMETER/OZONE/PSAP/M1 - Ship in port | acxaoshtdmaM1.00 | Suspect |
D150302.13 | ACX/AERI/IRT/MWR/MWR3C/PRP/TSI/M1 - Ship passed under bridges | acxtsiM1.00, acxmwrM1.00 | Suspect |
D150302.15 | ACX/HSRL/M1 - Instrument covered while in port | acxhsrlM1.a1 | Incorrect |
D150302.16 | ACX/AERI/AOSMET/CEIL/CEILPBLHT/IRT/LDIS/MWR/MWR3C/NAV/PRP/TSI/M1/S1/S2 - Ship was in port | acxmwrM1.00, acxtsiM1.00 | Does not affect quality |
D150302.6 | ACX/HTDMA/M1 - Periodic missing data | acxaoshtdmaM1.00 | Missing |
D150303.2 | ACX/HSRL/M1 - Instrument Covered | acxhsrlM1.a1 | Incorrect |
D150402.2 | ACX/HTDMA/M1 - Failure to fill butanol into HTDMA | acxaoshtdmaM1.00 | Incorrect |
D150819.2 | ACX/HTDMA/M1 - Reprocess: Missing data each day | acxaoshtdmaM1.00 | Does not affect quality |
D160224.4 | AWR/PSAP/M1 - Pump failure | awraospsap3wM1.b1 | Incorrect |
D160315.5 | AWR/GVRP/M1 - Incorrect data from lost thermal control | awrgvrpM1.b1, awrgvrpM1.a1 | Incorrect |
D160315.6 | AWR/GVRP/M1 - Missing data | awrgvrpM1.b1, awrgvrpM1.a1, awrgvrpM1.00 | Missing |
D160316.2 | AWR/NEPHELOMETER/M1 - Instrument startup | awraosnephdryM1.b1, awraoshumidgrM1.00 | Incorrect |
D160418.2 | AWR/PSAP/M1 - Instrument spin-up period | awraospsap3wM1.b1 | Incorrect |
D160602.1 | ASI/TRACEGAS/M1 - Faulty NOy mass flow controller | asiaosnoxM1.00, asiaosnoxM1.a1 | Suspect |
D160608.1 | ASI/MFR/M1 - Connector Problem | asimfr10mM1.a0, asimfr10mM1.b1, asimfr10mM1.00 | Incorrect |
D160608.3 | ASI/TRACEGAS/M1 - Air leak | asiaoscoM1.a1, asiaoscoM1.00 | Incorrect |
D160609.3 | AWR/NEPHELOMETER/M1 - Bulb burned out | awraosnephdryM1.b1, awraoshumidgrM1.00 | Incorrect |
D160610.11 | ASI/RWP/M1 - Loose connection | asi1290rwpprecipmomM1.a0, asi1290rwpwindconM1.a1, asi1290rwpwindmomM1.a0, asi1290rwpprecipconM1.a1 | Incorrect |
D160610.5 | ASI/SASHE/M1 - Instrument | asisashemfrM1.b1, asisashenirM1.b1, asisashenirhisunM1.a0, asisashevishisunM1.a0, asisashevisM1.b1 | Suspect |
D160612.1 | ASI/MFR/M1 - Misconfigured logger, lat/lon incorrect | asimfr10mM1.a0, asimfr10mM1.00, asimfr10mM1.b1 | Incorrect |
D160616.6 | AWR/PSAP/M1 - Pump inoperational | awraospsap3wM1.b1 | Incorrect |
D160616.7 | AWR/PSAP/M1 - Pump failure | awraospsap3wM1.b1 | Incorrect |
D160616.8 | ASI/PSAP/M1 - Pre-deployment data | asiaospsap3wM1.b1, asiaospsap3w1mM1.b1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaospsap3wM1.00 | Incorrect |
D160620.5 | ASI/MFR/M1 - Reprocess: Incorrect lat/lon | asimfr10mM1.b1, asimfr10mM1.a0 | Suspect |
D160621.4 | ASI/AOS/M1 - Manifold blower not working | asiaospsap3w1mM1.b1, asiaoscpcfM1.b1, asiaoscpcfM1.a1, asiaossp2auxM1.a0, asiaosnoxM1.00, asiaospsap3wM1.00, asiaoscoM1.a1, asiaospsap3wM1.b1, asiaosozoneM1.00, asiaosso2M1.00, asiaosozoneM1.a1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaoscpcfM1.00, asiaoscoM1.00, asiaossp2auxM1.00 | Incorrect |
D160621.6 | ASI/MWR3C/M1 - Reprocess: Incorrect calibration | asimwr3cM1.00, asimwr3cM1.b1 | Incorrect |
D160622.1 | ASI/OZONE/PTR-MS/TRACEGAS/M1 - Sampling cabin air | asiaosozoneM1.00, asiaosso2M1.00, asiaosso2M1.a1, asiaoscoM1.a1, asiaoscoM1.00, asiaosozoneM1.a1 | Incorrect |
D160622.3 | ASI/MWR/M1 - Uncertain calibration-RECALIBRATE | asimwrtipM1.a1, asimwrlosM1.b1 | Suspect |
D160629.3 | ASI/RAIN/M1 - Instrument not installed | asiraintbM1.b1 | Incorrect |
D160701.2 | ASI/MWR/S1 - Instrument malfunction | asimwrlosS1.b1, asimwrtipS1.a1, asimwrS1.00 | Incorrect |
D160707.1 | ASI/TRACEGAS/M1 - NOy Channel failed | asiaosnoxM1.a1 | Missing |
D160707.2 | ASI/TRACEGAS/M1 - Slow return to ambient measurement after HNO3 calibration | asiaosnoxM1.a1 | Suspect |
D160708.12 | ASI/PSAP/M1 - Transmission less than 0.7 | asiaospsap3wM1.b1, asiaospsap3w1mM1.b1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaospsap3wM1.00 | Incorrect |
D160722.1 | AWR/CPC/NEPHELOMETER/PSAP/M1 - Low impactor flow | awraospsap3wM1.b1, awraosnephdryM1.b1, awraoshumidgrM1.00 | Suspect |
D160803.4 | ASI/MWR/S1 - Radiometer removed | asimwrlosS1.b1, asimwrS1.00, asimwrtipS1.a1 | Missing |
D160815.1 | AWR/NEPHELOMETER/M1 - Bulb burned out | awraoshumidgrM1.00, awraosnephdryM1.b1 | Incorrect |
D160819.3 | ASI/PSAP/M1 - Transmittance less than vendor threshold | asiaospsap3w1mM1.b1, asiaospsap3wM1.b1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaospsap3wM1.00 | Incorrect |
D160907.12 | ASI/CPC/M1 - Instrument testing | asiaoscpcfM1.b1, asiaoscpcfM1.a1 | Incorrect |
D160907.13 | ASI/CPC/M1 - Instrument maintence | asiaoscpcfM1.b1, asiaoscpcfM1.a1 | Incorrect |
D160907.2 | ENA/RWP/C1 - Data System Upgrade | ena1290rwpprecipmeanlowC1.a1, ena1290rwpprecipmeanhighC1.a1 | Missing |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/14/2015 | 0641 | 01/22/2015 | 1739 | Suspect |
Subject: | ACX/HSRL/M1 - Instrument down at times |
DataStreams: | acxhsrlM1.a1 |
Description: | The HSRL went down at times during this period. |
Measurements: | acxhsrlM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/31/2015 | 1630 | 02/12/2015 | 1400 | Missing |
Subject: | ACX/S-TABLE/M1 - Instrument |
DataStreams: | acxrphtiltM1.a1, acxrphM1.00, acxrphcontrolM1.a1 |
Description: | MWACR data will not be from vertically pointing antenna |
Measurements: | acxrphtiltM1.a1:
acxrphcontrolM1.a1:
acxrphM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/29/2015 | 1400 | 01/30/2015 | 2154 | Missing |
Subject: | ACX/S-TABLE/M1 - Missing Data: Ship in Port |
DataStreams: | acxrphtiltM1.a1, acxrphM1.00, acxrphcontrolM1.a1 |
Description: | Instrument shut down while in port |
Measurements: | acxrphtiltM1.a1:
acxrphcontrolM1.a1:
acxrphM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/29/2015 | 1748 | 01/30/2015 | 1805 | Suspect |
Subject: | ACX/CCN/CPC/HTDMA/NEPHELOMETER/OZONE/PSAP/M1 - Ship in port |
DataStreams: | acxaoshtdmaM1.00 |
Description: | Ship was in port and data were likely impacted by anthropogenic sources. |
Measurements: | acxaoshtdmaM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/30/2015 | 1851 | 01/30/2015 | 1856 | Suspect |
01/29/2015 | 1638 | 01/29/2015 | 1640 | Suspect |
01/30/2015 | 1818 | 01/30/2015 | 1827 | Suspect |
01/29/2015 | 1710 | 01/29/2015 | 1711 | Suspect |
Subject: | ACX/AERI/IRT/MWR/MWR3C/PRP/TSI/M1 - Ship passed under bridges |
DataStreams: | acxtsiM1.00, acxmwrM1.00 |
Description: | Ship passed under bridges while in port. Use caution as the bridges may be in the field of view of the instrument. |
Measurements: | acxmwrM1.00:
acxtsiM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/29/2015 | 1300 | 01/30/2015 | 2140 | Incorrect |
Subject: | ACX/HSRL/M1 - Instrument covered while in port |
DataStreams: | acxhsrlM1.a1 |
Description: | Instrument was covered while in port. |
Measurements: | acxhsrlM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/29/2015 | 1748 | 01/29/2015 | 1805 | Does not affect quality |
Subject: | ACX/AERI/AOSMET/CEIL/CEILPBLHT/IRT/LDIS/MWR/MWR3C/NAV/PRP/TSI/M1/S1/S2 - Ship was in port |
DataStreams: | acxmwrM1.00, acxtsiM1.00 |
Description: | Ship was in port of San Francisco |
Measurements: | acxmwrM1.00:
acxtsiM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/18/2015 | 0945 | 01/18/2015 | 2014 | Missing |
01/21/2015 | 0949 | 01/21/2015 | 2018 | Missing |
01/20/2015 | 0940 | 01/20/2015 | 2020 | Missing |
01/13/2015 | 0945 | 01/13/2015 | 2014 | Missing |
01/17/2015 | 0947 | 01/17/2015 | 2016 | Missing |
01/19/2015 | 0942 | 01/19/2015 | 2023 | Missing |
01/14/2015 | 0942 | 01/14/2015 | 2023 | Missing |
01/15/2015 | 0940 | 01/15/2015 | 2020 | Missing |
01/12/2015 | 0947 | 01/12/2015 | 2016 | Missing |
01/16/2015 | 0949 | 01/16/2015 | 2018 | Missing |
01/11/2015 | 0949 | 01/11/2015 | 2018 | Missing |
Subject: | ACX/HTDMA/M1 - Periodic missing data |
DataStreams: | acxaoshtdmaM1.00 |
Description: | For this time period, there is missing data daily between approximately 10 UTC to 20 UTC. |
Measurements: | acxaoshtdmaM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/12/2015 | 0520 | 02/15/2015 | 1305 | Incorrect |
Subject: | ACX/HSRL/M1 - Instrument Covered |
DataStreams: | acxhsrlM1.a1 |
Description: | Instrument was covered while returning to port at the end of the campaign. |
Measurements: | acxhsrlM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/31/2015 | 0130 | 02/11/2015 | 0952 | Incorrect |
Subject: | ACX/HTDMA/M1 - Failure to fill butanol into HTDMA |
DataStreams: | acxaoshtdmaM1.00 |
Description: | CPC counts went to zero and remained at zero until the end of the stated time range. The CPC was on and detecting only shot noise from the optical detector. Indications suggest that butanol was not being filled into the HT-DMA |
Measurements: | acxaoshtdmaM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/05/2015 | 2012 | 02/11/2015 | 1709 | Does not affect quality |
Subject: | ACX/HTDMA/M1 - Reprocess: Missing data each day |
DataStreams: | acxaoshtdmaM1.00 |
Description: | There was a period of missing data each day in the originally collected data files. A set of 39 replacement data files has been transferred to the DMF. These files include all the the data in the original files as well as the data from the missing periods. Reprocessing the data will result in including the missing data. |
Measurements: | acxaoshtdmaM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/21/2016 | 0337 | 02/22/2016 | 2153 | Incorrect |
Subject: | AWR/PSAP/M1 - Pump failure |
DataStreams: | awraospsap3wM1.b1 |
Description: | Pump began failing periodically. The appropriate dates are listed. |
Measurements: | awraospsap3wM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/30/2016 | 0300 | 02/26/2016 | 2300 | Incorrect |
Subject: | AWR/GVRP/M1 - Incorrect data from lost thermal control |
DataStreams: | awrgvrpM1.b1, awrgvrpM1.a1 |
Description: | The radiometer lost thermal control |
Measurements: | awrgvrpM1.a1:
awrgvrpM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/26/2016 | 2010 | 06/13/2016 | 0912 | Missing |
Subject: | AWR/GVRP/M1 - Missing data |
DataStreams: | awrgvrpM1.b1, awrgvrpM1.a1, awrgvrpM1.00 |
Description: | Radiometer removed for repairs |
Measurements: | awrgvrpM1.00:
awrgvrpM1.a1:
awrgvrpM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/15/2015 | 2050 | 11/16/2015 | 2044 | Incorrect |
Subject: | AWR/NEPHELOMETER/M1 - Instrument startup |
DataStreams: | awraosnephdryM1.b1, awraoshumidgrM1.00 |
Description: | Instrument was just turned on and not yet operating under normal conditions. No valid data. |
Measurements: | awraoshumidgrM1.00:
awraosnephdryM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/15/2015 | 2049 | 11/17/2015 | 0044 | Incorrect |
Subject: | AWR/PSAP/M1 - Instrument spin-up period |
DataStreams: | awraospsap3wM1.b1 |
Description: | Data unreliable during instrument spin-up period at the begin of the deployment. |
Measurements: | awraospsap3wM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/27/2016 | 1338 | 05/17/2016 | 1222 | Suspect |
Subject: | ASI/TRACEGAS/M1 - Faulty NOy mass flow controller |
DataStreams: | asiaosnoxM1.00, asiaosnoxM1.a1 |
Description: | NOy flow started dropping from the the expected 1.0 L/min at 08:27 UTC on 05/12/2016. It continued to fall gradually until on 05/12/2016 at 15:30 UTC it was down to .01 L/min. NOy MFC was replaced. As of 05/17/2016 12:22 UTC the instrument is back up and running with the correct flow. |
Measurements: | asiaosnoxM1.00:
asiaosnoxM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/26/2016 | 1359 | 06/07/2016 | 1630 | Incorrect |
Subject: | ASI/MFR/M1 - Connector Problem |
DataStreams: | asimfr10mM1.a0, asimfr10mM1.b1, asimfr10mM1.00 |
Description: | When the instrument cable was attached a pin was bent completely over that caused a host of issues with the data. Do not use any of the data covered by this DQR. |
Measurements: | asimfr10mM1.b1:
asimfr10mM1.a0:
asimfr10mM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/03/2016 | 1549 | 06/06/2016 | 1958 | Incorrect |
Subject: | ASI/TRACEGAS/M1 - Air leak |
DataStreams: | asiaoscoM1.a1, asiaoscoM1.00 |
Description: | Filter change resulted in total leak to cabin air. Data irrecoverable. |
Measurements: | asiaoscoM1.a1:
asiaoscoM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/03/2016 | 0335 | 06/04/2016 | 0300 | Incorrect |
Subject: | AWR/NEPHELOMETER/M1 - Bulb burned out |
DataStreams: | awraosnephdryM1.b1, awraoshumidgrM1.00 |
Description: | Nephelometer bulb was burned out. No valid data for the entire time range. |
Measurements: | awraoshumidgrM1.00:
awraosnephdryM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/09/2016 | 0000 | 06/09/2016 | 1246 | Incorrect |
Subject: | ASI/RWP/M1 - Loose connection |
DataStreams: | asi1290rwpprecipmomM1.a0, asi1290rwpwindconM1.a1, asi1290rwpwindmomM1.a0, asi1290rwpprecipconM1.a1 |
Description: | Missing and incorrect data due to loose connections. |
Measurements: | asi1290rwpprecipconM1.a1:
asi1290rwpprecipmomM1.a0:
asi1290rwpwindconM1.a1:
asi1290rwpwindmomM1.a0:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/31/2016 | 0000 | 06/01/2016 | 1644 | Suspect |
Subject: | ASI/SASHE/M1 - Instrument |
DataStreams: | asisashemfrM1.b1, asisashenirM1.b1, asisashenirhisunM1.a0, asisashevishisunM1.a0, asisashevisM1.b1 |
Description: | REQUIRED |
Measurements: | asisashevisM1.b1:
asisashenirhisunM1.a0:
asisashemfrM1.b1:
asisashenirM1.b1:
asisashevishisunM1.a0:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/05/2016 | 0700 | 05/05/2016 | 0955 | Incorrect |
05/26/2016 | 0700 | 05/26/2016 | 0955 | Incorrect |
05/12/2016 | 0700 | 05/12/2016 | 0955 | Incorrect |
05/11/2016 | 0700 | 05/11/2016 | 0955 | Incorrect |
05/22/2016 | 0700 | 05/22/2016 | 0955 | Incorrect |
06/02/2016 | 0700 | 06/02/2016 | 0955 | Incorrect |
05/18/2016 | 0700 | 05/18/2016 | 0955 | Incorrect |
05/04/2016 | 0700 | 05/04/2016 | 0955 | Incorrect |
06/05/2016 | 0700 | 06/05/2016 | 0955 | Incorrect |
05/02/2016 | 0700 | 05/02/2016 | 0955 | Incorrect |
06/01/2016 | 0700 | 06/01/2016 | 0955 | Incorrect |
05/16/2016 | 0700 | 05/16/2016 | 0955 | Incorrect |
05/14/2016 | 0700 | 05/14/2016 | 0955 | Incorrect |
06/07/2016 | 0700 | 06/07/2016 | 0955 | Incorrect |
05/25/2016 | 0700 | 05/25/2016 | 0955 | Incorrect |
05/15/2016 | 0700 | 05/15/2016 | 0955 | Incorrect |
05/08/2016 | 0700 | 05/08/2016 | 0955 | Incorrect |
06/08/2016 | 0700 | 06/08/2016 | 0955 | Incorrect |
05/07/2016 | 0700 | 05/07/2016 | 0955 | Incorrect |
05/03/2016 | 0700 | 05/03/2016 | 0955 | Incorrect |
05/19/2016 | 0700 | 05/19/2016 | 0955 | Incorrect |
05/31/2016 | 0700 | 05/31/2016 | 0955 | Incorrect |
05/28/2016 | 0700 | 05/28/2016 | 0955 | Incorrect |
05/01/2016 | 0700 | 05/01/2016 | 0955 | Incorrect |
05/17/2016 | 0700 | 05/17/2016 | 0955 | Incorrect |
05/13/2016 | 0700 | 05/13/2016 | 0955 | Incorrect |
05/10/2016 | 0700 | 05/10/2016 | 0955 | Incorrect |
05/24/2016 | 0700 | 05/24/2016 | 0955 | Incorrect |
06/09/2016 | 0700 | 06/09/2016 | 0955 | Incorrect |
05/29/2016 | 0700 | 05/29/2016 | 0955 | Incorrect |
05/06/2016 | 0700 | 05/06/2016 | 0955 | Incorrect |
05/27/2016 | 0700 | 05/27/2016 | 0955 | Incorrect |
06/06/2016 | 0700 | 06/06/2016 | 0955 | Incorrect |
04/29/2016 | 0700 | 04/29/2016 | 0955 | Incorrect |
06/04/2016 | 0700 | 06/04/2016 | 0955 | Incorrect |
05/21/2016 | 0700 | 05/21/2016 | 0955 | Incorrect |
06/03/2016 | 0700 | 06/03/2016 | 0955 | Incorrect |
05/09/2016 | 0700 | 05/09/2016 | 0955 | Incorrect |
05/30/2016 | 0700 | 05/30/2016 | 0955 | Incorrect |
04/28/2016 | 0700 | 04/28/2016 | 0955 | Incorrect |
04/27/2016 | 0700 | 04/27/2016 | 0955 | Incorrect |
05/23/2016 | 0700 | 05/23/2016 | 0955 | Incorrect |
04/30/2016 | 0700 | 04/30/2016 | 0955 | Incorrect |
06/10/2016 | 0700 | 06/10/2016 | 0955 | Incorrect |
05/20/2016 | 0700 | 05/20/2016 | 0955 | Incorrect |
Subject: | ASI/MFR/M1 - Misconfigured logger, lat/lon incorrect |
DataStreams: | asimfr10mM1.a0, asimfr10mM1.00, asimfr10mM1.b1 |
Description: | The data logger had incorrect latitude and longitude settings. This caused the measurement range to be at the wrong setting when the sun came up resulting in the channels over-ranging. Though the lat/lon are not correct, the reflected irradiance data outside of the affected time range are OK and completely acceptable to use. |
Measurements: | asimfr10mM1.b1:
asimfr10mM1.a0:
asimfr10mM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/01/2016 | 0000 | 04/07/2016 | 2257 | Incorrect |
Subject: | AWR/PSAP/M1 - Pump inoperational |
DataStreams: | awraospsap3wM1.b1 |
Description: | Pump inoperational until the end date. |
Measurements: | awraospsap3wM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/12/2016 | 1642 | 03/17/2016 | 2211 | Incorrect |
03/29/2016 | 1952 | 03/31/2016 | 2359 | Incorrect |
03/01/2016 | 0000 | 03/01/2016 | 2330 | Incorrect |
Subject: | AWR/PSAP/M1 - Pump failure |
DataStreams: | awraospsap3wM1.b1 |
Description: | Pump failed. Operator repeatedly started and stopped pump. Listed are gaps greater than one hour where flow was insufficient. |
Measurements: | awraospsap3wM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/23/2016 | 0938 | 04/27/2016 | 1500 | Incorrect |
Subject: | ASI/PSAP/M1 - Pre-deployment data |
DataStreams: | asiaospsap3wM1.b1, asiaospsap3w1mM1.b1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaospsap3wM1.00 |
Description: | The instrument was affected by setting changes and people nearby. |
Measurements: | asiaospsap3w1sM1.b1:
asiaospsap3wM1.a1:
asiaospsap3w1mM1.b1:
asiaospsap3wM1.b1:
asiaospsap3wM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/26/2016 | 1359 | 06/10/2016 | 1851 | Suspect |
Subject: | ASI/MFR/M1 - Reprocess: Incorrect lat/lon |
DataStreams: | asimfr10mM1.b1, asimfr10mM1.a0 |
Description: | The lat/lon is incorrect. This DQR is set as Suspect as the irradiance data outside of some morning hours are not impacted, and the mentor doesn't want potential data users to dismiss all these data for that reason alone. That said, if the lat/lon is used then steps should be made in processing to correct the lat/lon. Correct vales are: -7.9674 / -14.3494 |
Measurements: | asimfr10mM1.b1:
asimfr10mM1.a0:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/16/2016 | 0042 | 06/16/2016 | 1345 | Incorrect |
Subject: | ASI/AOS/M1 - Manifold blower not working |
DataStreams: | asiaospsap3w1mM1.b1, asiaoscpcfM1.b1, asiaoscpcfM1.a1, asiaossp2auxM1.a0, asiaosnoxM1.00, asiaospsap3wM1.00, asiaoscoM1.a1, asiaospsap3wM1.b1, asiaosozoneM1.00, asiaosso2M1.00, asiaosozoneM1.a1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaoscpcfM1.00, asiaoscoM1.00, asiaossp2auxM1.00 |
Description: | Manifold blower not working, instrument sample flows either zero or different than specified. Sampling through the stack not isokinetic. |
Measurements: | asiaosso2M1.00:
asiaosozoneM1.a1:
asiaossp2auxM1.a0:
asiaoscoM1.a1:
asiaospsap3w1mM1.b1:
asiaospsap3wM1.a1:
asiaospsap3wM1.b1:
asiaospsap3wM1.00:
asiaosozoneM1.00:
asiaospsap3w1sM1.b1:
asiaosnoxM1.00:
asiaoscpcfM1.a1:
asiaoscoM1.00:
asiaoscpcfM1.00:
asiaossp2auxM1.00:
asiaoscpcfM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/27/2016 | 1540 | 07/15/2016 | 0000 | Incorrect |
Subject: | ASI/MWR3C/M1 - Reprocess: Incorrect calibration |
DataStreams: | asimwr3cM1.00, asimwr3cM1.b1 |
Description: | The radiometer had obstructions in the FOV and was not calibrating properly |
Measurements: | asimwr3cM1.00:
asimwr3cM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/25/2016 | 0837 | 05/25/2016 | 1251 | Incorrect |
Subject: | ASI/OZONE/PTR-MS/TRACEGAS/M1 - Sampling cabin air |
DataStreams: | asiaosozoneM1.00, asiaosso2M1.00, asiaosso2M1.a1, asiaoscoM1.a1, asiaoscoM1.00, asiaosozoneM1.a1 |
Description: | Inlet system turned off. Sampling cabin air. No effect on NO/NOx/NOy. |
Measurements: | asiaosso2M1.00:
asiaosozoneM1.a1:
asiaosso2M1.a1:
asiaoscoM1.a1:
asiaoscoM1.00:
asiaosozoneM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/21/2016 | 1624 | 06/08/2016 | 2100 | Suspect |
Subject: | ASI/MWR/M1 - Uncertain calibration-RECALIBRATE |
DataStreams: | asimwrtipM1.a1, asimwrlosM1.b1 |
Description: | There may be a slight obstruction on the radiometer FOV while scanning. The scanning angles were changed. |
Measurements: | asimwrlosM1.b1:
asimwrtipM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/23/2016 | 0913 | 05/12/2016 | 2359 | Incorrect |
Subject: | ASI/RAIN/M1 - Instrument not installed |
DataStreams: | asiraintbM1.b1 |
Description: | The instrument was not installed during this time. Reported data are incorrect and not representative of conditions. |
Measurements: | asiraintbM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/11/2016 | 1600 | 07/12/2016 | 0000 | Incorrect |
Subject: | ASI/MWR/S1 - Instrument malfunction |
DataStreams: | asimwrlosS1.b1, asimwrtipS1.a1, asimwrS1.00 |
Description: | The instrument had a mechanical problem with the rotating mirror. |
Measurements: | asimwrlosS1.b1:
asimwrtipS1.a1:
asimwrS1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/12/2016 | 0903 | 05/17/2016 | 1618 | Missing |
Subject: | ASI/TRACEGAS/M1 - NOy Channel failed |
DataStreams: | asiaosnoxM1.a1 |
Description: | Instrument Mass Flow Controller for the NOy channel died (slowly). It was replaced and normal function restored. |
Measurements: | asiaosnoxM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/01/2016 | 0000 | 06/24/2016 | 0800 | Suspect |
Subject: | ASI/TRACEGAS/M1 - Slow return to ambient measurement after HNO3 calibration |
DataStreams: | asiaosnoxM1.a1 |
Description: | Nitric acid permeation source is used to calibrate at 06:00 on odd days. The response on the NO2 and NOy channels is large and takes excessive time to recover after the calibration. This is apparent as a spike in the data after the calibration. Users should ignore this spike. HNO3 calibration was turned off. |
Measurements: | asiaosnoxM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/25/2016 | 0235 | 06/25/2016 | 0820 | Incorrect |
06/30/2016 | 0740 | 06/30/2016 | 0913 | Incorrect |
06/27/2016 | 2142 | 06/28/2016 | 0007 | Incorrect |
06/29/2016 | 0651 | 06/29/2016 | 0950 | Incorrect |
06/26/2016 | 0204 | 06/26/2016 | 0726 | Incorrect |
06/12/2016 | 1755 | 06/13/2016 | 0948 | Incorrect |
06/13/2016 | 2303 | 06/14/2016 | 0009 | Incorrect |
06/28/2016 | 0354 | 06/28/2016 | 0943 | Incorrect |
06/05/2016 | 2257 | 06/06/2016 | 1042 | Incorrect |
06/03/2016 | 0519 | 06/03/2016 | 1000 | Incorrect |
06/14/2016 | 0407 | 06/14/2016 | 0941 | Incorrect |
06/24/2016 | 2213 | 06/25/2016 | 0007 | Incorrect |
06/26/2016 | 2104 | 06/27/2016 | 0859 | Incorrect |
06/20/2016 | 0415 | 06/20/2016 | 1000 | Incorrect |
06/22/2016 | 0508 | 06/22/2016 | 1004 | Incorrect |
06/05/2016 | 0246 | 06/05/2016 | 1213 | Incorrect |
06/15/2016 | 0601 | 06/15/2016 | 1005 | Incorrect |
Subject: | ASI/PSAP/M1 - Transmission less than 0.7 |
DataStreams: | asiaospsap3wM1.b1, asiaospsap3w1mM1.b1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaospsap3wM1.00 |
Description: | Vendor specifies valid data only when Tr > 0.7. These are periods > 1 h where the filter wasn't changed and the Tr went < 0.7. |
Measurements: | asiaospsap3w1sM1.b1:
asiaospsap3wM1.a1:
asiaospsap3w1mM1.b1:
asiaospsap3wM1.b1:
asiaospsap3wM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/18/2016 | 0400 | 07/21/2016 | 0500 | Suspect |
Subject: | AWR/CPC/NEPHELOMETER/PSAP/M1 - Low impactor flow |
DataStreams: | awraospsap3wM1.b1, awraosnephdryM1.b1, awraoshumidgrM1.00 |
Description: | CPC inlet not properly connected to the sample lines. Flow through the impactor below nominal. Instruments sampling cabin air at least part of the time. |
Measurements: | awraospsap3wM1.b1:
awraoshumidgrM1.00:
awraosnephdryM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/12/2016 | 0000 | 08/22/2016 | 1746 | Missing |
Subject: | ASI/MWR/S1 - Radiometer removed |
DataStreams: | asimwrlosS1.b1, asimwrS1.00, asimwrtipS1.a1 |
Description: | The radiometer was sent to the vendor for repairs |
Measurements: | asimwrlosS1.b1:
asimwrtipS1.a1:
asimwrS1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/12/2016 | 0300 | 08/12/2016 | 1100 | Incorrect |
Subject: | AWR/NEPHELOMETER/M1 - Bulb burned out |
DataStreams: | awraoshumidgrM1.00, awraosnephdryM1.b1 |
Description: | Nephelometer bulb burned out. No valid data from this period. |
Measurements: | awraoshumidgrM1.00:
awraosnephdryM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/14/2016 | 0347 | 07/14/2016 | 0805 | Incorrect |
07/03/2016 | 1044 | 07/03/2016 | 1541 | Incorrect |
07/03/2016 | 0217 | 07/03/2016 | 0603 | Incorrect |
07/04/2016 | 0612 | 07/04/2016 | 0727 | Incorrect |
07/16/2016 | 0133 | 07/16/2016 | 0607 | Incorrect |
07/03/2016 | 2136 | 07/03/2016 | 2357 | Incorrect |
07/22/2016 | 0218 | 07/22/2016 | 0911 | Incorrect |
07/11/2016 | 0358 | 07/11/2016 | 0850 | Incorrect |
07/18/2016 | 0721 | 07/18/2016 | 0907 | Incorrect |
07/23/2016 | 1656 | 07/23/2016 | 1919 | Incorrect |
07/09/2016 | 0336 | 07/09/2016 | 0604 | Incorrect |
07/20/2016 | 0745 | 07/20/2016 | 0940 | Incorrect |
07/25/2016 | 0400 | 07/25/2016 | 0849 | Incorrect |
07/24/2016 | 0402 | 07/24/2016 | 0930 | Incorrect |
07/09/2016 | 1300 | 07/09/2016 | 1849 | Incorrect |
07/15/2016 | 0237 | 07/15/2016 | 0954 | Incorrect |
07/01/2016 | 0719 | 07/01/2016 | 0914 | Incorrect |
07/10/2016 | 0126 | 07/10/2016 | 0610 | Incorrect |
Subject: | ASI/PSAP/M1 - Transmittance less than vendor threshold |
DataStreams: | asiaospsap3w1mM1.b1, asiaospsap3wM1.b1, asiaospsap3w1sM1.b1, asiaospsap3wM1.a1, asiaospsap3wM1.00 |
Description: | Periods greater than 1 hour where the transmittance is less than 0.7. This is the threshold by the vendor for valid data. Other gaps in data greater than 1 hour are also included. |
Measurements: | asiaospsap3w1sM1.b1:
asiaospsap3wM1.a1:
asiaospsap3w1mM1.b1:
asiaospsap3wM1.b1:
asiaospsap3wM1.00:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/03/2016 | 1314 | 09/03/2016 | 1327 | Incorrect |
Subject: | ASI/CPC/M1 - Instrument testing |
DataStreams: | asiaoscpcfM1.b1, asiaoscpcfM1.a1 |
Description: | During this time tests were being run with a HEPA filter on the inlet. Data is not representative of ambient aerosol concentrations |
Measurements: | asiaoscpcfM1.a1:
asiaoscpcfM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/06/2016 | 1004 | 09/06/2016 | 1029 | Incorrect |
09/06/2016 | 1815 | 09/06/2016 | 1819 | Incorrect |
Subject: | ASI/CPC/M1 - Instrument maintence |
DataStreams: | asiaoscpcfM1.b1, asiaoscpcfM1.a1 |
Description: | During these intervals, connections were being removed from the CPC to prepare for it to take the place of the SMPS CPC. |
Measurements: | asiaoscpcfM1.a1:
asiaoscpcfM1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/22/2016 | 1401 | 08/23/2016 | 1909 | Missing |
Subject: | ENA/RWP/C1 - Data System Upgrade |
DataStreams: | ena1290rwpprecipmeanlowC1.a1, ena1290rwpprecipmeanhighC1.a1 |
Description: | Data lost during the site data system upgrade. |
Measurements: | ena1290rwpprecipmeanlowC1.a1:
ena1290rwpprecipmeanhighC1.a1:
|