DQR ID | Subject | Data Streams Affected |
---|---|---|
D160411.1 | ENA/UHSAS/C1 - Intermittent spikes in the lower size bins | enaaosuhsasC1.a1 |
D160411.2 | ENA/UHSAS/C1 - Instrument not sampling ambient air | enaaosuhsasC1.a1 |
D160427.7 | ENA/C1 - Reprocess: Slightly incorrect location fields | enaaoscpcfC1.a1, enametC1.b1 |
D160610.10 | ENA/UHSAS/C1 - High counts in lower size bins | enaaosuhsasC1.a1 |
D160610.9 | ENA/UHSAS/C1 - missing data | enaaosuhsasC1.a1 |
D160613.1 | ENA/CAPS-PMEX/NEPHELOMETER/PSAP/C1 - Impactor not switching | enaaosnephdryC1.a1, enaaosnephdryC1.b1 |
D160701.3 | ENA/AOS/C1 - | enaaoscpcfC1.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/28/2016 | 2200 | 04/01/2016 | 2330 |
Subject: | ENA/UHSAS/C1 - Intermittent spikes in the lower size bins |
DataStreams: | enaaosuhsasC1.a1 |
Description: | Intermittent spikes in the 3 lowest size bins. Other size bins should not be affected. |
Measurements: | enaaosuhsasC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/31/2016 | 1600 | 04/01/2016 | 1025 |
03/30/2016 | 0900 | 03/30/2016 | 1100 |
03/30/2016 | 1530 | 03/30/2016 | 1900 |
Subject: | ENA/UHSAS/C1 - Instrument not sampling ambient air |
DataStreams: | enaaosuhsasC1.a1 |
Description: | Instrument was periodically offline or not sampling ambient air for troubleshooting purposes. Data missing or no valid data. |
Measurements: | enaaosuhsasC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2013 | 0941 | 04/30/2016 | 2359 |
Subject: | ENA/C1 - Reprocess: Slightly incorrect location fields |
DataStreams: | enaaoscpcfC1.a1, enametC1.b1 |
Description: | Some of the instruments are being processed with the previous "GRW-Azores" lat/lon/alt instead of the new "ENA-Azores" lat/lon/alt. The differences are minor, but will be corrected. The respective GRW and ENA lat, lon, and alt values are as follows: GRW lat = 39.0911 ; ENA lat = 39.0916 ; GRW lon = -28.0297 ; ENA lon = -28.0257 ; GRW alt = 26 ; ENA alt = 30.48 ; |
Measurements: | enaaoscpcfC1.a1:
enametC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/07/2016 | 1340 | 06/08/2016 | 0200 |
Subject: | ENA/UHSAS/C1 - High counts in lower size bins |
DataStreams: | enaaosuhsasC1.a1 |
Description: | High counts in the 3 lowest size bins. Other size bins should not be affected. |
Measurements: | enaaosuhsasC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/06/2016 | 2210 | 06/07/2016 | 1340 |
Subject: | ENA/UHSAS/C1 - missing data |
DataStreams: | enaaosuhsasC1.a1 |
Description: | Instrument's internal hard drive was full and no new data was being saved except a few samples occasionally. |
Measurements: | enaaosuhsasC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/10/2016 | 1500 | 06/12/2016 | 1100 |
Subject: | ENA/CAPS-PMEX/NEPHELOMETER/PSAP/C1 - Impactor not switching |
DataStreams: | enaaosnephdryC1.a1, enaaosnephdryC1.b1 |
Description: | Impactor power accidentally unplugged. Impactor not switching and stuck in 10um position. The quality of data variables is not affected. |
Measurements: | enaaosnephdryC1.a1:
enaaosnephdryC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/20/2016 | 1820 | 06/21/2016 | 0835 |
Subject: | ENA/AOS/C1 - |
DataStreams: | enaaoscpcfC1.a1 |
Description: | During a measurement of the inlet flow rate, the cpcf inlet became plugged and the instrument was flooded with butanol. After removing the butanol and allowing the system to dry, the cpc returned to normal operation. |
Measurements: | enaaoscpcfC1.a1:
|