DQR ID | Subject | Data Streams Affected |
---|---|---|
D050622.1 | SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect (AEM failure) | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
D051111.11 | SGP/EBBR/E13 - metadata corrections | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
D051116.2 | SGP/CO2FLX/C1 - downwelling longwave hemispheric irradiance incorrect | sgp30co2flx4mmetC1.b1 |
D051116.3 | SGP/CO2FLX/C1 - Soil Temperature measurements | sgp30co2flx4mmetC1.b1 |
D060107.1 | SGP/CO2FLX/C1 - Reprocess: calibration error | sgp30co2flx4mC1.b1 |
D060630.6 | SGP/IRT/C1 - Reprocess: Longwave Calibration error | sgpirt25mC1.b1 |
D070416.4 | SGP/CO2FLX/C1 - downwelling longwave hemispheric irradiance incorrect | sgp30co2flx4mmetC1.b1 |
D071011.2 | SGP/CO2FLX/C1 - Reprocess: 4m instruments height | sgp30co2flx4mC1.b1 |
D081202.1 | SGP/CO2FLX/C1 - Reprocessed: Recalibration | sgp30co2flx4mC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/08/2005 | 1900 | 07/06/2005 | 1630 |
Subject: | SGP/EBBR/E13 - Sensible and Latent Heat Fluxes Incorrect (AEM failure) |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | The AEM was stuck in the home 30 position most of this period. Therefore, the sensible and latent heat fluxes are incorrect during most of this period. |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E13 - metadata corrections |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E13 data collected by ARM back to the installation of the instrument in September 1992. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for systems 3) Correction of soil type 4) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/28/2004 | 1900 | 11/16/2005 | 0000 |
Subject: | SGP/CO2FLX/C1 - downwelling longwave hemispheric irradiance incorrect |
DataStreams: | sgp30co2flx4mmetC1.b1 |
Description: | A problem was identified with the downwelling longwave hemispheric irradiance (variable "r_down_long_hemisp") calibration of our Kipp & Zonen CNR1 radiometer. The offset of the instrument is believed to be incorrect over the specified time frame, and a correction of the problem is underway. |
Measurements: | sgp30co2flx4mmetC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/18/2002 | 0000 | 11/16/2005 | 0000 |
Subject: | SGP/CO2FLX/C1 - Soil Temperature measurements |
DataStreams: | sgp30co2flx4mmetC1.b1 |
Description: | Current data quality check (qc) procedure does not catch spikes in soil temperature measurements. A new qc procedure is being tested and will improve the current procedure. |
Measurements: | sgp30co2flx4mmetC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/27/2005 | 0000 | 01/06/2006 | 2359 |
Subject: | SGP/CO2FLX/C1 - Reprocess: calibration error |
DataStreams: | sgp30co2flx4mC1.b1 |
Description: | A problem was identified with the calibration of the instrument performed on May 27, 2005. A study to correct this bad calibration is underway. |
Measurements: | sgp30co2flx4mC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/15/2004 | 2052 | 02/14/2006 | 2050 |
Subject: | SGP/IRT/C1 - Reprocess: Longwave Calibration error |
DataStreams: | sgpirt25mC1.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | sgpirt25mC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/28/2004 | 0000 | 04/02/2007 | 1930 |
Subject: | SGP/CO2FLX/C1 - downwelling longwave hemispheric irradiance incorrect |
DataStreams: | sgp30co2flx4mmetC1.b1 |
Description: | Downwelling longwave radiation measurements (variable "r_down_long_hemisp") are bad due to a wiring issue. Users should not use the downwelling longwave hemispheric irradiance during this period. The downwelling shortwave and longwave radiation at CF is also available from the Broadband Radiometer Station (BRS). |
Measurements: | sgp30co2flx4mmetC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/17/2003 | 0000 | 10/11/2007 | 0000 |
Subject: | SGP/CO2FLX/C1 - Reprocess: 4m instruments height |
DataStreams: | sgp30co2flx4mC1.b1 |
Description: | The height of the 4m instruments is 4.8 m and not 4.65 m as shown in b1 datastream |
Measurements: | sgp30co2flx4mC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/26/2005 | 0000 | 01/11/2006 | 2359 |
Subject: | SGP/CO2FLX/C1 - Reprocessed: Recalibration |
DataStreams: | sgp30co2flx4mC1.b1 |
Description: | The 4m CO2 flux system was calibrated on May 25, 2005. After the calibration was performed, calibration coefficients used to measure CO2 density were not updated. This added an OFFSET to the CO2 density measurements. The data have been reprocessed to address the offset. The reprocessed data were archived in December 2008. Please retrieve the updated files for use in your analysis. |
Measurements: | sgp30co2flx4mC1.b1:
|