DQR ID | Subject | Data Streams Affected |
---|---|---|
D120522.10 | TWP/QCRAD/C1 - LWdn ventilator failed | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.11 | TWP/QCRAD/C1 - LWup and dn fluxes Tc/Td bad | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.2 | TWP/QCRAD/C1 - LWup connection bad | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.3 | TWP/QCRAD/C1 - Spikes in temperature data | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.4 | TWP/QCRAD/C1 - Upwelling fluxes too low | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.5 | TWP/QCRAD/C1 - Upwelling LW and SW radiometers inverted | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.6 | TWP/QCRAD/C1 - Shortwave downwelling fluxes too low | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.7 | TWP/QCRAD/C1 - Reprocess: Incorrect datalogger program affecting PIR1 and PIR2 downwelling longwave | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.8 | TWP/QCRAD/C1 - Reprocess: NIP calibration | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120522.9 | TWP/QCRAD/C1 - Upwelling flux incorrect | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120523.1 | TWP/QCRAD/C1 - Downwelling LW flux appears incorrect | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
D120529.2 | TWP/QCRAD/C2 - MFRSR installation period | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120606.2 | TWP/QCRAD/C2 - Reprocess: Incorrect calibration coefficients | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120606.3 | TWP/QCRAD/C2 - Air temperature noisy or bad | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120606.4 | TWP/QCRAD/C2 - Case and dome temperatures noisy or bad | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120606.5 | TWP/QCRAD/C2 - Downwelling LW too high | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120607.1 | TWP/QCRAD/C2 - NIP cable bad | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120607.2 | TWP/QCRAD/C2 - Direct normal reading too low | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120607.3 | TWP/QCRAD/C2 - Tracker failure | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
D120607.4 | TWP/QCRAD/C2 - upwelling radiometers inverted | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/14/2008 | 0200 | 08/18/2008 | 0545 |
Subject: | TWP/QCRAD/C1 - LWdn ventilator failed |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | LWdn flux may be questionable during this time. Described in instrument DQR D080826.3: During the time range specified the PIR2 output is questionable due to ventilator fan failure. Although the PIR is temperature compensated, data review indicates that the PIR2 didn't compare as well with PIR1. Typical differences during full sun are approximately 10 w/m2. During this time period differences of 10-14 W/m2 were noted. |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2001 | 2000 | 03/13/2003 | 2300 |
11/01/2006 | 0000 | 12/01/2006 | 0000 |
Subject: | TWP/QCRAD/C1 - LWup and dn fluxes Tc/Td bad |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | Upwelling and downwelling longwave case and dome temperatures and fluxes appear to be incorrect during these times. No instrument DQRs exist for these time periods |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/11/1996 | 0000 | 02/27/1997 | 0659 |
Subject: | TWP/QCRAD/C1 - LWup connection bad |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | Data from the upwelling longwave radiometer are not valid for this period because of an incorrect connection to the data logger. Described in instrument DQR D000711.68. |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/12/1998 | 0000 | 05/01/1998 | 0000 |
Subject: | TWP/QCRAD/C1 - Spikes in temperature data |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | Beginning on 980212 (day #43) spikes began to occur in the surface temperature and water vapor pressure. These spikes occur approximately once per hour (the spacing is very regular but occasionally an hour is skipped). In the one-minute averaged data, the temperature spike lasts for only one minute and dips approximately 4-5 C below the actual temperature. The one-minute standard deviation is more dramatic, rising from about 0.1 to about 35. The one minute temperature minimum is the most easily identifiable, each hour when the spike occurs, the minimum is -245.84. The vapor pressure mean jumps from about 30 to over 50 and the standard deviation jumps from less than 1 to more than 200. This problem was fixed by the RESET team on 980501. Air temperature data is needed for tests on LW up and LW down pyrgeometer case and dome temperatures, and tests on the irradiances from upwelling LW/SW and downwelling LW. Problem documented in instrument DQR D000718.11 |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/22/1998 | 0400 | 05/02/1998 | 0400 |
02/28/1999 | 0000 | 03/07/1999 | 0700 |
03/27/2000 | 0700 | 04/02/2000 | 0400 |
10/15/2002 | 0000 | 10/30/2002 | 0000 |
Subject: | TWP/QCRAD/C1 - Upwelling fluxes too low |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | The upwelling longwave and shortwave fluxes appear to be too low during these periods. It is possible that these are caused by inverting the radiometers but no instrument DQRs exist documenting the changes during these times. |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/2003 | 0620 | 12/09/2003 | 1155 |
11/01/2004 | 0040 | 11/05/2004 | 2318 |
11/11/2005 | 2230 | 11/17/2005 | 0030 |
Subject: | TWP/QCRAD/C1 - Upwelling LW and SW radiometers inverted |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | The upwelling longwave and shortwave radiometers were inverted during this period for comparison with calibrated instruments. Documented in instrument DQRs: D031215.2, D041106.2, D051123.2 |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/24/1999 | 0000 | 11/11/1999 | 0000 |
Subject: | TWP/QCRAD/C1 - Shortwave downwelling fluxes too low |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | Downwelling shortwave total, diffuse and direct normal flux values are low. Sometimes this also impacts the best estimate flux. The source of this problem is not clear. No instrument DQRs exist describing this problem. |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/02/2004 | 0200 | 09/09/2005 | 2022 |
Subject: | TWP/QCRAD/C1 - Reprocess: Incorrect datalogger program affecting PIR1 and PIR2 downwelling |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | Downwelling longwave calibration incorrect. Needs to be reprocessed. Described in instrument DQR D051202.5: The excitation delays using in measuring the PIR1 case thermistor commonly named "Case1" and the PIR2 dome thermistor called "Dome2" were discovered to have been incorrectly set to 0 in the Skyrad datalogger program when the new CR23X based Skyrad loggers were installed. The result of no delay in these measurements results in an error in the measured resistance of the thermistors, Case1 and Dome2, and thus the calculated PIR1 and PIR2 irradiances. The absolute value of the errors are inversely proportial to temperature. Users can apply temperature dependent irradiance corrections shown in the table below. Recall that the reported uncertainty of PIRs is typically +-.25% to +-.5% or 1 to 2 W/m2. The error corrections become the same order of magnitude or larger than the instrument uncertainties at or below 260K or 9F. Irradiance Correction Table for Skyrad (TWP and NSA) DIR1 and DIR2 Irradiance DIR1 DIR1 DIR2 DIR2 T[F] Tc[K] [W/m2] Td[K] [W/m2] 109.4 316.13 0.00 316.13 0.00 100.5 311.20 -0.15 311.20 0.12 93.2 307.14 -0.12 307.14 0.10 87.0 303.70 -0.10 303.70 0.08 81.6 300.70 -0.17 300.70 0.14 77.0 298.15 -0.22 298.15 0.18 59.4 288.35 -0.34 288.35 0.27 47.4 281.72 -0.23 281.72 0.18 38.5 276.74 -0.42 276.74 0.34 31.3 272.77 -0.48 272.77 0.38 25.4 269.48 -0.61 269.48 0.49 20.3 266.67 -0.67 266.67 0.54 16.0 264.25 -0.82 264.25 0.66 12.1 262.11 -0.98 262.11 0.79 8.7 260.19 -0.97 260.19 0.78 5.6 258.46 -1.07 258.46 0.86 2.7 256.89 -1.17 256.89 0.94 0.1 255.44 -1.33 255.44 1.07 -2.3 254.11 -1.41 254.11 1.13 -4.5 252.87 -1.43 252.87 1.15 -6.6 251.71 -1.52 251.71 1.22 -8.5 250.63 -1.63 250.63 1.31 -10.4 249.62 -1.73 249.62 1.39 -12.2 248.58 -1.79 248.58 1.44 -15.4 246.82 -1.93 246.82 1.55 -18.3 245.23 -2.05 245.23 1.65 -20.9 243.78 -2.22 243.78 1.78 -23.3 242.44 -2.36 242.44 1.89 -25.5 241.21 -2.58 241.21 2.07 -27.5 240.07 -2.65 240.07 2.13 -29.5 239.01 -2.75 239.01 2.21 -31.3 238.00 -3.02 238.00 2.42 |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2004 | 0513 | 10/31/2004 | 2230 |
Subject: | TWP/QCRAD/C1 - Reprocess: NIP calibration |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | Direct normal flux has incorrect calibration coefficient but can be fixed as described in instrument DQR D041106.1: The tracker rotated and pulled the cable away from the NIP connector. In trying to discover the problem with the NIP a new NIP was put in. When the problem turned out to be the cable, the observers didn't put the former NIP back in. The NIP then in service was 31346E6 RS@45=8.1573 whereas the coefficients used were for the old NIP 299937E6 RS@45=7.8775 |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/03/2003 | 1700 | 03/13/2003 | 2130 |
Subject: | TWP/QCRAD/C1 - Upwelling flux incorrect |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | An incorrect datalogger configuration made upwelling fluxes incorrect during this time period. Described in instrument DQR D030317.3: The configuration for the SMET was inadvertently loaded into the GNDRAD at Manus at 03/03/2003 17:00 GMT. This error was found and corrected on 03/13/2003 at 21:30 GMT. Because the wrong channels were addressed with incorrect sampling coefficients, it would be very difficult (and in some cases impossible) to reconstruct the data for this week and 3 day period. |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2005 | 0500 | 11/17/2005 | 0700 |
Subject: | TWP/QCRAD/C1 - Downwelling LW flux appears incorrect |
DataStreams: | twpqcrad1longC1.c1, twpqcrad1longC1.c2, twpqcrad1longC1.s1, twpqcrad1longC1.s2 |
Description: | Downwelling longwave fluxes values appear incorrect during this time. The cause for the strange values is not known. No instrument DQRs exist describing this problem. |
Measurements: | twpqcrad1longC1.s1:
twpqcrad1longC1.c2:
twpqcrad1longC1.c1:
twpqcrad1longC1.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/1998 | 0000 | 11/19/1998 | 2359 |
Subject: | TWP/QCRAD/C2 - MFRSR installation period |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | The MFRSR was being installed during this time, with many changes. All data should be used with caution during this time. Described in instrument DQR D020613.4. |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/20/2002 | 2347 | 09/20/2003 | 2333 |
Subject: | TWP/QCRAD/C2 - Reprocess: Incorrect calibration coefficients |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | Incorrect calibration coefficients were used for downwelling shortwave and longwave irradiance. The following calculation method should be applied to correct the data, For the downwelling shortwave(PSPG) (DS) Old Calibration coefficient [W/m2\mV] =119.68 New Calibration Coefficient [W/m2\mV] =125.94 DS(new_value)[W/m2]=( DS(old_value)[W/m2]/ 119.68 [W/m2\mV] )* 125.94 [W/m2/mV] For the longwave irradiance (PIRG): If the .a0 and .b1 data set available the following procedure should be applied for the downwelling LW 1) Obtain the following variables from the 20s datastream for each one minute of the affected time range: inst_down_long_hemisp1_dome_resist (Rd) inst_down_long_ hemisp1_case_resist (Rc) inst_down_long_ hemisp1_tp (tpDIR_mV) 2) Using the 20s tp voltage in mV convert to uV. tpDIR[uV] = inst_down_long_hemisp1_tp [mV]*1000[uV/mV] 3) For each 20s data entry, convert Rd and Rc to temperature Td =1/ (a0 + (a1*LN (Rd*1000) + (a2*LN (Rd*1000)^3))) Tc = 1/ (a0 + (a1*LN (Rc*1000) + (a2*LN (Rc*1000)^3))) Where a0 = 0.0010295 a1 = 0.0002391 a2 = 0.0000001568 4) Apply for each 20s data entry: (correct k1=0.2755) WinDIR(W/m^2)= [0.2755*tpDIR] + Sigma*Tc^4 -4*Sigma*(Td^4 - Tc^4) Where, WinDIR = Corrected down_long_hemisp1 (W/m^2) Sigma = 5.6704E-8 (Stefan-Boltzman Constant) 5) Generate new 1 minute average from the three 20-second measurements For the longwave irradiance (PIRD): If the .a0 and .b1 data set available the following procedure should be applied for the downwelling LW 1) Obtain the following variables from the 20s datastream for each one minute of the affected time range: inst_down_long_hemisp2_dome_resist (Rd) inst_down_long_ hemisp2_case_resist (Rc) inst_down_long_ hemisp2_tp (tpDIR_mV) 2) Using the 20s tp voltage in mV convert to uV. tpDIR[uV] = inst_down_long_hemisp2_tp [mV]*1000[uV/mV] 3) For each 20s data entry, convert Rd and Rc to temperature Td =1/ (a0 + (a1*LN (Rd*1000) + (a2*LN (Rd*1000)^3))) Tc = 1/ (a0 + (a1*LN (Rc*1000) + (a2*LN (Rc*1000)^3))) Where a0 = 0.0010295 a1 = 0.0002391 a2 = 0.0000001568 4) Apply for each 20s data entry: (correct k1=0.2786) WinDIR(W/m^2)= [0.2786*tpDIR] + Sigma*Tc^4 -4*Sigma*(Td^4 - Tc^4) Where, WinDIR = Corrected down_long_hemisp2(W/m^2) Sigma = 5.6704E-8 (Stefan-Boltzman Constant) 5) Generate new 1 minute average from the three 20-second measurements This issue was also described in instrument DQR D031007.3. |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/06/1999 | 0000 | 03/07/1999 | 0900 |
02/01/2001 | 0000 | 03/15/2001 | 0000 |
Subject: | TWP/QCRAD/C2 - Air temperature noisy or bad |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | Air temperature is bad or noisy during this time. Air temperature data is needed for tests on LW up and LW down pyrgeometer case and dome temperatures, and tests on the irradiances from upwelling LW/SW and downwelling LW. There were no instrument DQRs on this problem at the time this report was submitted. |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/17/2001 | 0000 | 03/03/2003 | 2100 |
11/10/2006 | 1200 | 11/26/2006 | 2300 |
04/15/2009 | 0000 | 06/01/2009 | 0000 |
Subject: | TWP/QCRAD/C2 - Case and dome temperatures noisy or bad |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | Upwelling and downwelling longwave case and dome temperatures are noisy or bad during this time. Not all corrections and tests can be applied to LW fluxes as a result. No instrument DQRs exist describing this problem. |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2011 | 0143 | 01/28/2011 | 0600 |
Subject: | TWP/QCRAD/C2 - Downwelling LW too high |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | Downwelling longwave irradiance was too high compared to another instrument, possibly due to a bad connection. Problem described in instrument DQR D110317.3: |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/31/2007 | 0223 | 02/10/2007 | 0055 |
Subject: | TWP/QCRAD/C2 - NIP cable bad |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | Shortwave direct normal irradiance data are missing or incorrect due to instrument cable failure. Described in instrument DQR D070206.1. Note that fewer quality checks can be applied accurately to the BestEstimate data. |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/02/2008 | 2230 | 03/10/2008 | 2130 |
Subject: | TWP/QCRAD/C2 - Direct normal reading too low |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | Direct normal irradiance data is bad. Described in instrument DQR D080313.2. |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/01/1999 | 0000 | 11/01/1999 | 0000 |
05/26/2001 | 1200 | 06/18/2001 | 0400 |
06/25/2001 | 1800 | 08/16/2001 | 0400 |
12/01/2003 | 0000 | 01/01/2004 | 0000 |
12/17/2008 | 1942 | 12/21/2008 | 2215 |
03/25/2009 | 2000 | 05/18/2009 | 0442 |
06/16/2011 | 2335 | 08/15/2011 | 0130 |
10/06/2011 | 0000 | 12/31/2011 | 0000 |
Subject: | TWP/QCRAD/C2 - Tracker failure |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | Tracker appears to be out of alignment or inoperative during these times. The short_direct_normal (NIP) and down_short_diffuse_hemisp (8-48) data appear to be bad and not recoverable. Several of these periods are documented in instrument DQRs: D110831.1, D090328.1, D081222.3, D040107.1, D011207.1, D011019.8 |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/1999 | 0500 | 08/11/1999 | 2030 |
01/03/2000 | 2225 | 01/19/2000 | 2359 |
06/27/2000 | 0440 | 06/30/2000 | 2359 |
09/16/2003 | 0000 | 09/23/2003 | 0000 |
09/24/2004 | 0200 | 09/28/2004 | 0115 |
09/17/2005 | 0152 | 09/23/2005 | 0115 |
10/31/2001 | 0500 | 11/05/2001 | 2100 |
09/13/2002 | 2200 | 09/20/2002 | 2100 |
Subject: | TWP/QCRAD/C2 - upwelling radiometers inverted |
DataStreams: | twpqcrad1longC2.c1, twpqcrad1longC2.c2, twpqcrad1longC2.s1, twpqcrad1longC2.s2 |
Description: | During calibration check periods the gndrad instruments are inverted to compare with the skyrad pir and psp. Most periods described in instrument DQRs: D990909.1, D030224.1, D031007.4, D040929.2, D050926.6 Last two periods identified manually from data. |
Measurements: | twpqcrad1longC2.c2:
twpqcrad1longC2.c1:
twpqcrad1longC2.s1:
twpqcrad1longC2.s2:
|