DQR ID | Subject | Data Streams Affected |
---|---|---|
D020520.2 | SGP/OKM/X1 - Overview of Automated Data Quality -March 2002 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D031016.1 | SGP/OKM/X1 - Station Change | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2002 | 0000 | 03/31/2002 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality -March 2002 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Janet Martinez, the Mesonet QA manager of the automated quality assurance results for the March 2002 Oklahoma Mesonet data. ============================================================== Notes: On March 1 & 2, most of the state reported snow and a few hours of freezing rain. In spite of the fact that the effect of this snow/ice event was much less severe than the Jan 30-31 storm, the wind obs at 60 sites had to be manually flagged for time periods ranging from 3 to 26 hours due to freezing rain coating the anemometers. Temperatures in the state quickly recovered and on March 14, OKC set a record high temp for that date of 85 degrees. The southeast part of the state experienced heavy rains on two occasions, with Idabel leading the pack at nearly 10 inches of rain during March. The Mesonet Technicians began Spring Pass 2002 in March. During the month, they also resolved 75 trouble tickets! In addition to the work detailed in this report, their work included scheduled replacements of 10m wind direction monitors (in the past four months, 100 have been changed out), and replacement of failed net radiometers, soil moisture sensors, ground heat flux plates and soil temp probes. They also replaced 7 cup-type anemometers with starting threshold problems (likely caused by our three winter ice storms). The initial installation of telnet power switches at base stations continued. The data collection software and hardware for the ARS Micronet was upgraded to match that used by the Mesonet (upgraded in spring of 2001). The new collection software is called LoggerNet. Thanks to all involved in the successful completion of this upgrade. ** This month's QA report can also be found at the following URL: http://operations.ocs.ou.edu/pub/qa/monthly/mar02.htm This webpage is still under construction, so continue to send me your comments and suggestions. Janet ======================================================================== ------------------------------------------------------------------------ CORE MESONET QA REPORT ------------------------------------------------------------------------ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #6403 HOBA Leveled and cleaned gauge (reported phantom tips) #6417 CALV Checked and cleaned gauge (reported no melt during or after snow) #6463 NORM Replaced switch (tips 30% low compared to nearby sites) #6480 TISH Re-attached magnet & replaced switch TA9M Current: None Added: None Resolved: None WS2M Current: #6458 CHEY Starting threshold problems #6459 ELRE Starting threshold problems #6461 PUTN Starting threshold problems Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TB05 Current: None Added: #6514 HUGO Monthly QA indicates 5 degree C low bias Resolved: None TS30 Current: None Added: None Resolved: None ------------------------------------------------------------------------ ARS QA REPORT ------------------------------------------------------------------------ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #6435 A131 Adjusted magnet and switch (reported no tips in February) TS05 Current: #6490 A161 Reporting temps of -12 deg C Added: None Resolved: None TS10 Current: #6491 A161 Reporting temps of -15 deg C Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== "Current Tickets" are the unresolved tickets as of the last day of the month. "Added Tickets" are based on evaluations of parameters averaged over the month at 1800 UTC. Rain is evaluated as a monthly accumulation. "Resolved Tickets" are the problems that were fixed during the entire month. LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 09/28/2003 | 2359 |
Subject: | SGP/OKM/X1 - Station Change |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | The Mesonet station near Marshall was moved on September 25, 2003 to improve accessiblity for the Mesonet technicians who visit and maintain the site. The new site has the code MRSH. It replaces the old Marshall site that had the code MARS. Since the latitude and longitude of the stations are included in the cdf file, users of these data should not have a problem. |
Measurements: | sgpokmX1.01:
sgp15okmX1.a1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.b1:
|