DQR ID | Subject | Data Streams Affected |
---|---|---|
D041222.13 | SGP/EBBR/E15 - 6 Month Checks | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D050206.11 | SGP/EBBR/E15 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D050207.7 | SGP/EBBR/E15 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D050215.18 | SGP/EBBR/E15 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D050215.19 | SGP/EBBR/E15 - Wind Direction Frozen Stopped By Ice | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D050624.2 | SGP/EBBR/E15 - Net Radiation Too Large - Water in Bottom | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D051106.9 | SGP/EBBR/E15 - Soil Set #5 Temperature, Moisture, and Heat Flow Incorrect | sgp15ebbrE15.b1, sgp30ebbrE15.b1 |
D051111.12 | SGP/EBBR/E15 - metadata corrections | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D051215.3 | SGP/EBBR/E15 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect. | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D060111.10 | SGP/EBBR/E15 - Incorrect Sensible and Latent Heat Fluxes | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
D060501.15 | SGP/EBBR/E15 - Wind Speed Sensor Frozen Stopped | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/26/2004 | 1630 | 10/26/2004 | 1700 |
Subject: | SGP/EBBR/E15 - 6 Month Checks |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/04/2005 | 1010 | 01/05/2005 | 0200 |
Subject: | SGP/EBBR/E15 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/04/2005 | 1605 | 01/05/2005 | 0200 |
Subject: | SGP/EBBR/E15 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2005 | 0030 | 01/12/2005 | 1545 |
Subject: | SGP/EBBR/E15 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2005 | 0030 | 01/12/2005 | 0930 |
Subject: | SGP/EBBR/E15 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/13/2005 | 0800 | 05/24/2005 | 1700 |
Subject: | SGP/EBBR/E15 - Net Radiation Too Large - Water in Bottom |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | Water in the bottom dome of the net radiometer made the measurements incorrectly large. Sensible and latent heat fluxes were therefore incorrect. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/15/2005 | 2130 | 07/19/2005 | 1700 |
Subject: | SGP/EBBR/E15 - Soil Set #5 Temperature, Moisture, and Heat Flow Incorrect |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1 |
Description: | Rodents chewed the cables on all three soil set #5 sensors, making the measurements incorrect. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E15 - metadata corrections |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E15 data collected by ARM back to the installation of the instrument in September 1992. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil type 4) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/30/2005 | 0000 | 11/08/2005 | 1815 |
Subject: | SGP/EBBR/E15 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect. |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | The top dome of the net radiometer was broken, resulting in net radiations that were too small, and thus sensible and latent heat fluxes that were too small. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/10/2006 | 1330 | 01/17/2006 | 1730 |
Subject: | SGP/EBBR/E15 - Incorrect Sensible and Latent Heat Fluxes |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | Incorrect gradient measurements and sensible and latent heat fluxes resulted from the AEM not exchanging. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/22/2006 | 1300 | 02/22/2006 | 1530 |
Subject: | SGP/EBBR/E15 - Wind Speed Sensor Frozen Stopped |
DataStreams: | sgp15ebbrE15.b1, sgp30ebbrE15.b1, sgp5ebbrE15.b1 |
Description: | Freezing rain froze the wind speed sensor to a stopped condition during the period. |
Measurements: | sgp15ebbrE15.b1:
sgp30ebbrE15.b1:
sgp5ebbrE15.b1:
|