DQR ID | Subject | Data Streams Affected |
---|---|---|
D031029.1 | SGP/EBBR/E20 - Fuse Blown in AEM | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031204.19 | SGP/EBBR/E20 - 6 Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031208.5 | SGP/EBBR/E20 - Wind Direction Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031211.5 | SGP/EBBR/E20 - Pressure Sensor Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031222.20 | SGP/EBBR/E20 - Wind Speed Sensor Frozen By Ice Storm | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040304.19 | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040304.20 | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040507.2 | SGP/EBBR/E20 - Left Air Temperature Incorrect | sgp15ebbrE20.b1, sgp30baebbrE20.c1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040722.1 | SGP/EBBR/E20 - Wind Direction Stuck at 100 Degrees | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040813.2 | SGP/EBBR/E20 - AEM Failure | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D041222.16 | SGP/EBBR/E20 - 6 Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D050206.14 | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D050207.10 | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D050404.4 | SGP/EBBR/E20 - Temp. of thum_left Incorrect At Times | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D051112.7 | SGP/EBBR/E20 - metadata corrections | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 2100 | 10/29/2003 | 2300 |
Subject: | SGP/EBBR/E20 - Fuse Blown in AEM |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When the EBBR system restarted on 15 Oct. 2003, the AEM malfunctioned. Surface fluxes data during this period are incorrect. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/29/2003 | 2200 | 10/29/2003 | 2245 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/2003 | 0530 | 12/23/2003 | 2140 |
Subject: | SGP/EBBR/E20 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Wind direction is incorrect, reading at or about 0 or 15 to 25 degrees. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/28/2003 | 1430 | 01/21/2004 | 2130 |
Subject: | SGP/EBBR/E20 - Pressure Sensor Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The E20 pressure sensor suffered from spikes in pressure, which were related to increases in voltage during the day as the solar panels charged the battery. These spikes were not of a magnitude that would affect the 30 minute surface fluxes. Replacement of the pressure sensor solved the problem. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/13/2003 | 1100 | 12/13/2003 | 1230 |
Subject: | SGP/EBBR/E20 - Wind Speed Sensor Frozen By Ice Storm |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind speed sensor was frozen stopped by ice from a storm. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0505 | 02/02/2004 | 1845 |
Subject: | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0535 | 02/02/2004 | 1755 |
Subject: | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2004 | 0000 | 03/31/2004 | 2355 |
Subject: | SGP/EBBR/E20 - Left Air Temperature Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30baebbrE20.c1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The left air temperature, and therefore top and bottom air temperatures were offscale or incorrect on occasion. Bowen ratio, sensible heat flux, and latent heat flux were also incorrect during those times. Inspection of the data is required to detect the incorrect periods. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
sgp30baebbrE20.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/09/2004 | 1745 | 08/04/2004 | 1915 |
Subject: | SGP/EBBR/E20 - Wind Direction Stuck at 100 Degrees |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was stuck at about 100 degrees. This did not affect the primary measurements (net radiation, soil heat flow, sensible heat flux, latent heat flux). |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/03/2004 | 0300 | 09/15/2004 | 2000 |
09/24/2004 | 0700 | 09/29/2004 | 1800 |
Subject: | SGP/EBBR/E20 - AEM Failure |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The AEM hung inbetween positions; home signals were zero. The AEM fuse kept blowing, most likely because of worn rails or sleeves. This condition may reoccur. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2004 | 1730 | 09/29/2004 | 1800 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1420 | 01/07/2005 | 1650 |
Subject: | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/2005 | 0150 | 01/07/2005 | 1425 |
Subject: | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/20/2005 | 1230 | 04/27/2005 | 2000 |
Subject: | SGP/EBBR/E20 - Temp. of thum_left Incorrect At Times |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The temperature portion of the left T/RH probe temperature spiked at times. This was caused by a faulty surge protector in the J-Panel. |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E20 - metadata corrections |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E20 data collected by ARM back to the installation of the instrument in April 1993. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp30ebbrE20.b1:
sgp15ebbrE20.b1:
sgp5ebbrE20.b1:
|