DQR ID | Subject | Data Streams Affected |
---|---|---|
D011127.23 | SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checks | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D011129.6 | SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Data | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D011129.7 | SGP EBBR E7 - E7 EBBR All Data Incorrect | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D011129.8 | SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibration | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D011129.9 | SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Period | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D020716.26 | SGP/EBBR/E7 - Measurements Zero | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.00, sgp5ebbrE7.a1 |
D020716.27 | SGP/EBBR/E7 - AEM Hung | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D020716.28 | SGP/EBBR/E7 - Wind Speed Incorrect | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D020716.8 | SGP/EBBR/E7 - 6 Month Checks | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030110.30 | SGP/EBBR/E7 - Data Incorrect during 6 month checks | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030113.1 | SGP/EBBR/E7 - Wind speed incorrect | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030113.7 | SGP/EBBR/E7 - AEM Problems | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030113.8 | SGP/EBBR/E7 - T/RH Ventilator Fans Stopped | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030114.2 | SGP/EBBR/E7 - Data Reported as Zero following Logger Replacement | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030620.1 | SGP/EBBR/E7 - Soil Heat Flow #5 Incorrect | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030712.13 | SGP/EBBR/E7 - 6 Month Checks | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030712.9 | SGP/EBBR/E7 - AEM Hung Inbetween Home Position | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030729.3 | SGP/EBBR/E7 - AEM Malfunction, Some Data Incorrect | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030917.2 | SGP/EBBR/E7 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect | sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D030919.1 | SGP/EBBR/E7 - Data all zero | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D030919.3 | SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrect | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D031031.1 | SGP/EBBR/E7 - Reference Temperature Failure | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D031204.6 | SGP/EBBR/E7 - 6 Month Checks | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D031211.6 | SGP/EBBR/E7 - Pressure Sensor Data Incorrect | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
D031222.9 | SGP/EBBR/E7 - Wind Speed Sensor Frozen By Ice Storm | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D040206.3 | SGP/EBBR/E7 - Pressure Sensor Data Incorret | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D040304.3 | SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D040304.4 | SGP/EBBR/E7 - Tref Problem Causes All Temps. to be Incorrect | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D040813.8 | SGP/EBBR/E7 - Pressure Too High | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D041005.3 | SGP/EBBR/E7 - Data Missing | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D041222.8 | SGP/EBBR/E7 - 6 Month Checks | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D050206.6 | SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D050215.11 | SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D051024.1 | SGP/EBBR/E7 - Data Missing | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D051106.3 | SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D051112.4 | SGP/EBBR/E7 - metadata corrections | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D060111.3 | SGP/EBBR/E7 - Barometric Pressure Incorrect | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D060501.4 | SGP/EBBR/E7 - Fluxes and Gradient Measurements Incorrect | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D070215.3 | SGP/EBBR/E7 - Windspeed threshhold too high | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
D080212.1 | SGP/EBBR/E7 - Wind Speed Frozen Stopped | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/08/2001 | 1800 | 05/08/2001 | 1901 |
11/25/2001 | 1435 | 11/25/2001 | 1601 |
Subject: | SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/10/2001 | 1945 | 04/10/2001 | 2031 |
Subject: | SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Data |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The AEM stuck in one position, causing the indicated measurements and calculated quantities to be incorrect. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2001 | 1900 | 05/07/2001 | 1901 |
Subject: | SGP EBBR E7 - E7 EBBR All Data Incorrect |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The data was incorrect immediately after the re-calibrated system was installed and put into service. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2001 | 1930 | 05/07/2001 | 1931 |
Subject: | SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibration |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Soil temperature measurements and the half hour average were incorrect the half hour after starting the recalibrated system, causing other measurements and calculated quantities to be incorrect. |
Measurements: | sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/28/2001 | 1900 | 08/28/2001 | 1901 |
Subject: | SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Period |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Soil temperature measurements and the half hour average were incorrect the half hour after a missing data period, causing other measurements and calculated quantities to be incorrect. |
Measurements: | sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 2100 | 03/12/2002 | 2101 |
Subject: | SGP/EBBR/E7 - Measurements Zero |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.00, sgp5ebbrE7.a1 |
Description: | The indicated measurements were zero after interruption of the CR10 program. |
Measurements: | sgp5ebbrE7.00:
sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/14/2002 | 2200 | 04/23/2002 | 1531 |
05/20/2002 | 1200 | 06/06/2002 | 1501 |
Subject: | SGP/EBBR/E7 - AEM Hung |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The indicated measurements were incorrect because the automatic exchange mechanism hung in one position. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2002 | 1200 | 05/21/2002 | 1601 |
Subject: | SGP/EBBR/E7 - Wind Speed Incorrect |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The wind speed and resultant wind speed are incorrect for the indicated times because a cup had broken off of the cup anemometer. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2002 | 1645 | 05/07/2002 | 1716 |
Subject: | SGP/EBBR/E7 - 6 Month Checks |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/19/2002 | 2000 | 11/19/2002 | 2030 |
Subject: | SGP/EBBR/E7 - Data Incorrect during 6 month checks |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2002 | 2100 | 07/18/2002 | 1700 |
Subject: | SGP/EBBR/E7 - Wind speed incorrect |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | A wind speed sensor electronics problem limited the measurement to the sensor offset. This data was incorrect. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/10/2002 | 0800 | 07/16/2002 | 1900 |
07/22/2002 | 1630 | 07/30/2002 | 1630 |
08/24/2002 | 0230 | 08/27/2002 | 1800 |
Subject: | SGP/EBBR/E7 - AEM Problems |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The AEM (Automatic Exchange Mechanism) hung in a non-home position for a few lengthy periods, during which the indicated measurements are incorrect. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/2002 | 1700 | 10/08/2002 | 1645 |
Subject: | SGP/EBBR/E7 - T/RH Ventilator Fans Stopped |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The temperature and relative humidity gradients are suspect because the ventilator fans were not operating during this time period. The data needs to be carefully inspected to determine when measurements, if any, are correct. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/30/2002 | 1800 | 07/30/2002 | 1829 |
Subject: | SGP/EBBR/E7 - Data Reported as Zero following Logger Replacement |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The data was reported as zero after a data logger replacement. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/11/2003 | 1730 | 07/15/2003 | 2000 |
Subject: | SGP/EBBR/E7 - Soil Heat Flow #5 Incorrect |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Soil Heat Flow Plate #5 data was intermittently incorrect at first (values too small negative), then was almost constantly so during the last half of the period. Comparison of the individual soil heat flows will quickly show the times that soil heat flow #5 was incorrect. |
Measurements: | sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/22/2003 | 1650 | 04/22/2003 | 1720 |
Subject: | SGP/EBBR/E7 - 6 Month Checks |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/24/2003 | 0900 | 03/11/2003 | 1800 |
Subject: | SGP/EBBR/E7 - AEM Hung Inbetween Home Position |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The AEM was hung inbetween home positions, causing many measurements to be incorrect. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/27/2003 | 1330 | 10/07/2003 | 2000 |
Subject: | SGP/EBBR/E7 - AEM Malfunction, Some Data Incorrect |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | After a while, the teflon slides on the AEMs warp from heat and use. This tends to make the AEM drag, jam, and get hung. This happened at E7 EBBR. Replacement of the AEM resolved the problem. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 11/18/2003 | 2000 |
Subject: | SGP/EBBR/E7 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | Soil Heat Flow #5 went offscale at times. Latent and Sensible Heat Fluxes were incorrect when this occurred. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/26/2003 | 1800 | 08/26/2003 | 1800 |
Subject: | SGP/EBBR/E7 - Data all zero |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | Data values were all zero after restarting the CR10 datalogger. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/29/2003 | 0230 | 09/05/2003 | 1730 |
Subject: | SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrect |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/19/2003 | 1730 | 10/19/2003 | 1930 |
10/20/2003 | 1330 | 10/20/2003 | 1630 |
10/21/2003 | 1630 | 10/21/2003 | 1830 |
10/22/2003 | 0000 | 10/22/2003 | 1830 |
10/23/2003 | 0000 | 10/23/2003 | 1630 |
Subject: | SGP/EBBR/E7 - Reference Temperature Failure |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The reference T sensor was not working, affecting other temperature sensors. Sensible and latent heat fluxes were incorrect when this occurred. |
Measurements: | sgp5ebbrE7.b1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/04/2003 | 2200 | 11/04/2003 | 2230 |
Subject: | SGP/EBBR/E7 - 6 Month Checks |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/07/2003 | 1500 | 10/12/2003 | 2355 |
Subject: | SGP/EBBR/E7 - Pressure Sensor Data Incorrect |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.a1 |
Description: | The E7 pressure sensor suffered from spikes in pressure, which were related to increases in voltage during the day as the solar panels charged the battery. These spikes were not of a magnitude that would affect the 30 minute surface fluxes. Replacement of the pressure sensor solved the problem. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/09/2003 | 2220 | 12/10/2003 | 1200 |
Subject: | SGP/EBBR/E7 - Wind Speed Sensor Frozen By Ice Storm |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The wind speed sensor was frozen stopped by ice. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 01/28/2004 | 2030 |
Subject: | SGP/EBBR/E7 - Pressure Sensor Data Incorret |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The E7 pressure sensor suffered from spikes in pressure, which were related to increases in voltage during the day as the solar panels charged the battery. These spikes were not of a magnitude that would affect the 30 minute surface fluxes. Replacement of the pressure sensor solved the problem. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2004 | 0755 | 01/28/2004 | 1550 |
02/02/2004 | 0840 | 02/03/2004 | 1650 |
02/05/2004 | 2330 | 02/06/2004 | 1210 |
Subject: | SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The wind speed sensor was frozen stopped by ice from a storm. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/19/2004 | 2120 | 02/20/2004 | 0305 |
Subject: | SGP/EBBR/E7 - Tref Problem Causes All Temps. to be Incorrect |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The Tref sensor went crazy for this brief period, making all temperature measurements incorrect. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/10/2004 | 1925 | 08/24/2004 | 1820 |
Subject: | SGP/EBBR/E7 - Pressure Too High |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | When data collection resumed after a missing period, the barometer pressure had become very high, 102 kPa, which was not correct. This condition resulted from an incorrect calibration being used. Sensible heat flux was overestimated by about 4% and latent heat flux underestimated by about 4% because of the high pressure readings. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/04/2004 | 1705 | 08/10/2004 | 1925 |
Subject: | SGP/EBBR/E7 - Data Missing |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | A power outage resulted in missing data for the indicated period. |
Measurements: | sgp15ebbrE7.b1:
sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/2004 | 2000 | 10/05/2004 | 2030 |
Subject: | SGP/EBBR/E7 - 6 Month Checks |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/04/2005 | 1450 | 01/05/2005 | 0100 |
Subject: | SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/11/2005 | 1330 | 01/12/2005 | 0050 |
Subject: | SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/20/2005 | 2030 | 10/07/2005 | 1530 |
Subject: | SGP/EBBR/E7 - Data Missing |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | Data was missing because of a communication problem. However, previously missing data from 10/07-18 was recovered from the EBRR storage module and ingested, thereby reducing the data lost period significantly. |
Measurements: | sgp15ebbrE7.b1:
sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/14/2005 | 0000 | 09/20/2005 | 2000 |
Subject: | SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The top dome of the net radiometer was cracked; net radiation, and sensible and latent heat flux measurements were incorrect. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E7 - metadata corrections |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E7 data collected by ARM back to the installation of the instrument in May 1993. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/04/2005 | 1700 | 02/20/2006 | 2230 |
Subject: | SGP/EBBR/E7 - Barometric Pressure Incorrect |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The pressure measurement sometimes dropped to zero during daytime because of unstable battery voltage. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/21/2006 | 1000 | 03/21/2006 | 2030 |
Subject: | SGP/EBBR/E7 - Fluxes and Gradient Measurements Incorrect |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The left AEM aspirator was not working during this period, resulting in incorrect gradient and flux measurements. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2007 | 0100 | 02/20/2007 | 2100 |
Subject: | SGP/EBBR/E7 - Windspeed threshhold too high |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | The wind speed sensor developed worn bearings and therefore too high a starting threshhold. The data user should compare the EBBR wind speed with the SMOS wind speed to detect periods when the EBBR wind speed threshhold caused poor data quality. |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/11/2008 | 1100 | 02/12/2008 | 1730 |
02/21/2008 | 1230 | 02/21/2008 | 2300 |
Subject: | SGP/EBBR/E7 - Wind Speed Frozen Stopped |
DataStreams: | sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1 |
Description: | Freezing rain stopped wind speed sensor. |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|