DQR ID | Subject | Data Streams Affected |
---|---|---|
D040904.2 | TWP/SKYRAD/C3 - Incorrect NIP cal coefficient | twpskyrad60sC3.b1 |
D050104.1 | TWP/SKYRAD/C3 - Reprocess: NIP calibrations incorrect | twpskyrad60sC3.b1, twpskyradC3.00 |
D050221.2 | TWP/GNDRAD/C3 - IRT bias | twpgndrad60sC3.b1 |
D060110.3 | TWP/SKYRAD/C3 - IRT damaged | twpskyrad20sC3.a0, twpskyrad60sC3.b1 |
D060111.1 | TWP/GNDRAD/C3 - IRT power | twpgndrad60sC3.b1 |
D060426.8 | TWP/SMET/C3 - ORG data noisy due to degraded ground | twpsmet60sC3.b1 |
D060630.36 | TWP/GNDRAD/C3 - Reprocess: Longwave Calibration error | twpgndrad60sC3.b1 |
D060818.3 | TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa | twpsmet60sC3.b1 |
D061011.4 | TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added | twpsmet60sC3.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/24/2004 | 0000 | 09/02/2004 | 2350 |
Subject: | TWP/SKYRAD/C3 - Incorrect NIP cal coefficient |
DataStreams: | twpskyrad60sC3.b1 |
Description: | During our site visit comparison at Darwin we observed that the skyrad NIP was reading about 50 w/m2 lower than the comparison cavity radfiometer and the replacement NIP on the comparison stand. We found that the calibration coefficient for the NIP (responsivity at 45o)was put in as 8.64X10-6. The NIP was new and had not been calibrated at SGP. The factory number was 8.04X10-6. We corrected the calibration coefficient and the instruments agreed to better than 5 w/m2. |
Measurements: | twpskyrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2004 | 0000 | 09/02/2004 | 0400 |
Subject: | TWP/SKYRAD/C3 - Reprocess: NIP calibrations incorrect |
DataStreams: | twpskyrad60sC3.b1, twpskyradC3.00 |
Description: | On 05/20 during installtion of the new Campbell datalogger system and associated program the NIP (S/N 33551E6) was assigned an incorrect calibration coefficient. A coefficient of 116.01 W/m2/mV was applied when it should have been 124.378 W/m2/mV. TWP reports SV0405D and SV0409D detail the activities which lead to this DQR. |
Measurements: | twpskyradC3.00:
twpskyrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/10/2004 | 0700 | 12/25/2004 | 0300 |
Subject: | TWP/GNDRAD/C3 - IRT bias |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The IRT measured higher surface temperatures than expected from the PIR, even at night. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2005 | 2314 | 03/07/2006 | 0257 |
Subject: | TWP/SKYRAD/C3 - IRT damaged |
DataStreams: | twpskyrad20sC3.a0, twpskyrad60sC3.b1 |
Description: | The analog output of the IRT was damaged by a lightning strike. The problem was corrected by replacing the instrument with a spare. The damaged IRT was returned to the vendor for repair. |
Measurements: | twpskyrad60sC3.b1:
twpskyrad20sC3.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/20/2005 | 2330 | 01/02/2006 | 2300 |
Subject: | TWP/GNDRAD/C3 - IRT power |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The IRT failed to report after a planned power outage to add lightning protection modules to the AC power wiring. The problem was corrected when a loose power connection to the logger was found, rectified, and power restored to the logger. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/2005 | 0000 | 08/24/2006 | 2359 |
Subject: | TWP/SMET/C3 - ORG data noisy due to degraded ground |
DataStreams: | twpsmet60sC3.b1 |
Description: | SMET Rain Data began to be noisy during December 2005 and the problem slowly became worse over time so that in February 2006 the ORG was reporting with a constant background value of around 0.10 mm/hr rain rate. ORG voltage showed a near constant value above the 85mV threshold. The ground for the ORG had become degraded and was lost due to corrosion. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2004 | 0100 | 12/21/2005 | 2137 |
Subject: | TWP/GNDRAD/C3 - Reprocess: Longwave Calibration error |
DataStreams: | twpgndrad60sC3.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/02/2003 | 0000 | 07/13/2006 | 2219 |
Subject: | TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa |
DataStreams: | twpsmet60sC3.b1 |
Description: | Barometric pressure data was converted from hPa to kPa in order to standardize the measurement units among ARM sites and to conform to accepted standard units determined by the scientific community. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 0000 | 09/26/2006 | 1435 |
Subject: | TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added |
DataStreams: | twpsmet60sC3.b1 |
Description: | A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 datastream. When reprocessing of this datastream occurs these variables will be added with -9999 (missing) as the value for dates prior to gauge installation. |
Measurements: | twpsmet60sC3.b1:
|