DQR ID | Subject | Data Streams Affected |
---|---|---|
D040318.10 | SGP/SMOS/E13 - 6-month Calibration Checks | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
D050209.10 | SGP/SMOS/E13 - Wind Data Suspect | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
D050322.3 | SGP/SMOS/E13 - T/RH sensor failure | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/16/2003 | 1827 | 10/16/2003 | 1855 |
04/15/2004 | 1958 | 04/15/2004 | 2020 |
10/28/2004 | 1835 | 10/28/2004 | 1855 |
04/15/2005 | 1435 | 04/15/2005 | 1455 |
11/23/2005 | 1940 | 11/23/2005 | 1953 |
05/01/2006 | 1438 | 05/01/2006 | 1545 |
10/13/2006 | 1605 | 10/13/2006 | 1635 |
04/16/2007 | 1414 | 04/16/2007 | 1441 |
Subject: | SGP/SMOS/E13 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Description: | During the time periods specified, the SMOS.E13 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. Calibration results are available from the OMIS database at http://www.ops.sgp.arm.gov:591/smos6cal/default.htm To view all 6-month calibration reports leave the date time entry blank. |
Measurements: | sgp1440smosE13.b1:
sgp30smosE13.b1:
sgp1smosE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 0000 | 02/03/2005 | 2359 |
Subject: | SGP/SMOS/E13 - Wind Data Suspect |
DataStreams: | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Description: | Wind speed and direction data suspect during time period due to icing. |
Measurements: | sgp1440smosE13.b1:
sgp30smosE13.b1:
sgp1smosE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2005 | 0258 | 04/01/2005 | 1545 |
Subject: | SGP/SMOS/E13 - T/RH sensor failure |
DataStreams: | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Description: | The T/RH sensor began to fail at high RH% values. Since this site has an aspirated radiation shield, values in excess of the 104% manufacturer limit are not expected to occur due to rain or condensation. |
Measurements: | sgp1440smosE13.b1:
sgp30smosE13.b1:
sgp1smosE13.b1:
|