DQR ID | Subject | Data Streams Affected |
---|---|---|
D010320.18 | SGP/OKM - Overview of Automated Data Quality -January 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010412.2 | SGP/OKM - Overview of Automated Data Quality - February 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010510.1 | SGP/OKM - Overview of Automated Data Quality - March 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010531.3 | SGP/OKM - CATO station retired | sgp05okmX1.b1, sgp15okmX1.b1, sgpokmX1.01 |
D010531.4 | SGP/OKM - BEEX station added | sgp05okmX1.b1, sgp15okmX1.b1, sgpokmX1.01 |
D010531.6 | SGP/OKM - Overview of Automated Data Quality - April 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010703.1 | SGP/OKM - Overview of Automated Data Quality - May 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010731.1 | SGP/OKM - Overview of Automated Data Quality - June 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010906.1 | SGP/OKM - Overview of Automated Data Quality - July 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D011015.1 | SGP/OKM - Overview of Automated Data Quality - August 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D011127.3 | SGP/OKM - Overview of Automated Data Quality - September 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D020131.2 | SGP/OKM/X1 - Overview of Automated Data Quality - November 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D020201.1 | SGP/OKM/X1 - Overview of Automated Data Quality - December 2001 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D031016.1 | SGP/OKM/X1 - Station Change | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2001 | 0000 | 01/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality -January 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the January 2001 Oklahoma Mesonet data. A major ice storm took place from January 28-30 across the northwest one-third of Oklahoma. The wind sensors became frozen at over 40 stations. Several occurrences in which soil temperature sensors have "heaved" themselves out of the ground have been noted by techs recently. After analyzing the soil temperature data for January, it appears that 9 additional stations may be having the same problem. Trouble tickets have been issued so that the suspect sites can be visited during this coming month. The unusually wet and cold winter is likely to blame. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: #5355 ERIC Sensor frequently drops to 0% Added: None Resolved: #5332 MEDI Replaced sensor with suspected 5% high bias WDIR Current: None Added: None Resolved: #5344 SKIA Replaced sensor stuck at 360 degrees WSPD Current: None Added: None Resolved: #5405 PAUL Replaced suspect sensor PRES Current: None Added: None Resolved: #5403 VINI Replaced barometer reporting +300 mb high bias SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 Added: #5394 SEIL Sensor reporting 80% low Resolved: None RAIN Current: #5397 MEDF Gauge stuck at 0 during precip event Added: None Resolved: #5351 STIL Replaced gauge with bad switch #5396 NORM Replaced suspect gauge #5398 CLOU Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: #5402 MAYR 3 C cool bias Added: None Resolved: None TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: None TB05 Current: #5416 REDR Possible erosion causing TB05 to drop well below freezing #5419 MARS Possible erosion causing TB05 to drop well below freezing Added: #5454 BLAC Possible erosion #5455 KING Possible erosion #5456 OKMU Possible erosion #5457 PRYO Possible erosion #5458 FORA Possible erosion #5459 TAHL Possible erosion Resolved: #5215 PUTN Repaired lose wire on mux TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5395 A150 Repaired gauge by adjusting switch TS05 Current: None Added: #5453 A165 Possible erosion Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2001 | 0000 | 02/28/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - February 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the February 2001 Oklahoma Mesonet data. 3 more ice storms hit the state during February. The first storm lasted from the 8th through the 11th and affected much of northwest Oklahoma. The second event lasted from the 15th through the 18th and affected 27 stations in south-central and east-central Oklahoma. The third event affected over 40 stations in central and northeastern Oklahoma on the 28th of the month. Wind data from these events was flagged appropriately in the QA database. HUGO became the first site to get struck by lightning during 2001. On the 24th, the site suffered major damage to the logger, battery, rain gauge, temperature and RH, and soil temperatures sensors. =============================================================== TAIR Current: #5442 GRA2 Sensor reporting 3.5 C warm bias Added: None Resolved: None RELH Current: #5505 HUGO Lightning damage Added: None Resolved: #5355 ERIC Replaced erratic sensor #5441 HECT Repaired lose wire WDIR Current: None Added: None Resolved: None WSPD Current: #5490 RING Bad bearings suspected due to low bias Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 #5394 SEIL Sensor reporting 80% low Added: #5519 MEDF Monthly QA indicates 10% low bias Resolved: None RAIN Current: #5397 MEDF Gauge stuck at 0 during precip event #5511 HUGO Gauge occasionally double-tips #5466 PUTN Gauge under-reported rainfall by over 1 inch Added: None Resolved: None TA9M Current: #5492 JAYX Reporting 7-8 erratic obs per day Added: None Resolved: None WS2M Current: None Added: None Resolved: #5445 WAUR Replaced dirty bearings TS10 Current: #5507 HUGO Lightning damage Added: None Resolved: #5410 SKIA Tightened lose wire TB10 Current: #5402 MAYR 3 C cool bias #5468 STUA Sensor has 10 C warm bias Added: #5518 MEDF Monthly QA indicates 3 C warm bias Resolved: #5433 SHAW Reset sensor found heaved upward #5479 HASK Reset sensor found heaved upward TS05 Current: #5194 FAIR 5 C cool bias #5508 HUGO Lightning damage Added: None Resolved: None TB05 Current: #5419 MARS Possible erosion causing TB05 to drop well below freezing #5454 BLAC Possible erosion #5455 KING Possible erosion #5456 OKMU Possible erosion #5457 PRYO Possible erosion #5458 FORA Possible erosion #5459 TAHL Possible erosion Added: None Resolved: #5416 REDR Reset sensor found heaved upward #5417 SHAW Reset sensor found heaved upward #5480 HASK Reset sensor found heaved upward TS30 Current: #5509 HUGO Lightning damage Added: #5517 EUFA Monthly QA indicates 3 C cool bias Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: #5516 A149 Monthly QA indicates high bias Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5467 A121 Gauge under-reporting Added: None Resolved: #5452 A122 Replaced bad switch TS05 Current: #5453 A165 Possible erosion Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2001 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - March 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the March 2001 Oklahoma Mesonet data. 69 trouble tickets were resolved by the techs during March. WOW! You won't notice all of that work here in this report, because some of the fixes were for scheduled rotations of sensors and work done on OASIS sensors (both of which we haven't made a part of the monthly QA report as of yet.) Soil temperature probes under bare soil continue to be a major problem as over 20 stations have been found to have their probes literally heaved out of the ground. This is something we've never witnessed in the Mesonet EVER, and is likely due to all the wet, freezing weather we had this past winter. We'll hope it doesn't happen again for at least 8 more years. The Mesonet technicians are beginning their Spring Pass 2001 in which all sites will be visited over the next 3 months. During this pass, they will be taking site photos, maintaining the vegetation inside the site enclosure, cleaning sensors, and performing rain gauge tests. =============================================================== TAIR Current: None Added: None Resolved: #5442 GRA2 Replaced faulty sensor RELH Current: None Added: None Resolved: #5505 HUGO Replaced lightning-damaged sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #5490 RING Replaced damaged sensor PRES Current: None Added: None Resolved: None SRAD Current: #5519 MEDF Monthly QA indicates 10% low bias Added: None Resolved: #5072 KETC Replaced sensor with high bias #5159 FAIR Replaced lightning-damaged sensor #5394 SEIL Replaced sensor with low bias RAIN Current: #5511 HUGO Gauge occasionally double-tips Added: None Resolved: #5397 MEDF Replaced bad switch #5466 PUTN Replaced bad switch TA9M Current: None Added: None Resolved: #5492 JAYX Repaired lose wire WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #5507 HUGO Replaced lightning-damaged sensor TB10 Current: #5518 MEDF Monthly QA indicates 3 C warm bias Added: None Resolved: #5402 MAYR Replaced bad sensor #5468 STUA Replaced gopher-damaged sensor #5440 WILB Corrected erosion problem TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: #5508 HUGO Replaced lightning-damaged sensor TB05 Current: #5515 STIG Sensor reporting erratic values Added: #5569 CATO Check for erosion #5570 BREC Check for erosion Resolved: #5419 MARS Repaired erosion problem #5454 BLAC Repaired erosion problem #5455 KING Repaired erosion problem #5456 OKMU Repaired erosion problem #5457 PRYO Repaired erosion problem #5458 FORA Site checked for erosion #5459 TAHL Repaired erosion problem #5499 TISH Repaired erosion problem #5535 BIXB Repaired erosion problem #5536 WYNO Repaired erosion problem #5537 COPA Repaired erosion problem #5538 NOWA Repaired erosion problem #5539 MIAM Repaired erosion problem #5541 WILB Repaired erosion problem TS30 Current: #5517 EUFA Monthly QA indicates 3 C cool bias Added: None Resolved: #5509 HUGO Replaced lightning-damaged sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: #5522 A152 Repaired vandalized sensor RELH Current: None Added: None Resolved: #5516 A149 Replaced sensor with high bias SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5467 A121 Replaced bad switch TS05 Current: None Added: None Resolved: #5453 A165 Checked for erosion TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #5523 A165 Corrected wiring problem TS30 Current: None Added: None Resolved: #5524 A165 Corrected wiring problem ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 04/19/2001 | 2359 |
Subject: | SGP/OKM - CATO station retired |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | The Catoosa station (CATO) was decommissioned on April 19 due to poor site exposure and the end of the EPSCOR project. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgpokmX1.01:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/OKM - BEEX station added |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | A new site located at Bee (BEEX) was added beginning on April 1, 2001. It does not appear in data files before that date. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgpokmX1.01:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 04/30/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - April 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the April 2001 Oklahoma Mesonet data. TAIR Current: None Added: None Resolved: #5525 HUGO Replaced erratic sensor RELH Current: None Added: None Resolved: None WDIR Current: #5590 BURB Sensor reporting out of phase Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #5588 BBOW Replaced plugged-up barometer SRAD Current: None Added: None Resolved: #5519 MEDF Replaced sensor with low bias RAIN Current: None Added: None Resolved: #5511 HUGO Replaced gauge that occasionally double tips #5592 HASK Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #5623 BBOW Replaced sensor with noisy bearings TS10 Current: #5589 BURB Sensor has erratic 10 C warm bias Added: None Resolved: #5556 EUFA Replaced suspect sensor TB10 Current: None Added: None Resolved: #5518 MEDF Replaced sensor with 3 C warm bias #5553 NORM Repaired erosion problem #5558 EUFA Replaced suspect sensor TS05 Current: None Added: None Resolved: #5194 FAIR Replaced lightning-damaged sensor #5557 EUFA Replaced suspect sensor TB05 Current: None Added: None Resolved: #5515 STIG Replaced erratic sensor #5547 NORM Repaired erosion problem #5559 EUFA Replaced suspect sensor #5570 BREC Repaired erosion problem TS30 Current: None Added: None Resolved: #5517 EUFA Replaced suspect sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ====================================================================== |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2001 | 0000 | 05/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - May 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the May 2001 Oklahoma Mesonet data. ============================================================== Notes: Rotations of the wind speed sensors are coming to a close. Most all Mesonet sites have had their nose cones replaced. Pyranometers are now beginning to be rotated statewide. Most stations should have newly calibrated pyranometers by the end of the summer. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: #5639 NINN Sensor reporting many small spikes and dips not observed at nearby A122 #5707 ALTU Sensor stuck at 10-15% Added: None Resolved: None WDIR Current: None Added: None Resolved: #5590 BURB Repaired erroneous WDIR by fixing TA15 port WSPD Current: None Added: None Resolved: #5673 CALV Replaced sensor with noisy bearings PRES Current: None Added: None Resolved: #5644 CLAY Replaced bad barometer SRAD Current: None Added: None Resolved: None RAIN Current: #5666 GOOD Gauge missed rain event Added: None Resolved: #5662 BURB Replaced bad switch #5698 CLAY Replaced bad switch TA9M Current: #5658 MIAM Sensor reporting 20 C cool bias Added: None Resolved: None WS2M Current: None Added: None Resolved: #5664 MARE Replaced sensor with noisy bearings #5670 EUFA Replaced sensor with noisy bearings #5676 CALV Replaced sensor with noisy bearings #5685 CLAY Replaced sensor with dirty bearings TS10 Current: None Added: None Resolved: #5589 BURB Repaired erratic readings by fixing TA15 port TB10 Current: #5665 APAC Sensor reporting 10 C warm bias Added: None Resolved: None TS05 Current: None Added: None Resolved: None TB05 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5669 B123 Gauge reported rain in excess of 8 inches Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: #5671 A125 New sensor (installed via trouble ticket #5634) is also reporting erratic obs Added: None Resolved: #5634 A125 Replaced bad sensor TS15 Current: None Added: None Resolved: None TS30 Current: None Added: #5727 A135 Monthly QA indicates 4 C cool bias Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ====================================================================== |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/01/2001 | 0000 | 06/30/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - June 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the June 2001 Oklahoma Mesonet data. ============================================================== Notes: Spring Pass 2001 was completed in June. All 114 stations have now been visited, inspected, and maintained. In addition, over 1500 digital photos were taken to document the vegetation conditions at each site. The technicians now embark on Summer Pass 2001... =============================================================== TAIR Current: None Added: None Resolved: #5724 SALL Replaced bad sensor RELH Current: #5772 STIL Sensor stuck at 0% Added: None Resolved: #5639 NINN Replaced erratic sensor #5707 ALTU Replaced bad sensor WDIR Current: None Added: None Resolved: #5723 FREE Replaced defective sensor WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #5769 HECT Initial installation of barometer SRAD Current: None Added: None Resolved: #5702 OILT Replaced bad sensor #5851 FREE Replaced lightning-damaged sensor RAIN Current: #5778 STIL Double counts on one bucket Added: None Resolved: #5746 JAYX Fixed clogged gauge #5776 CLAR Repaired stuck buckets #5758 LANE Fixed double-tipping gauge #5771 MEDF Cleaned clogged gauge #5708 COPA Replaced suspect gauge #5666 GOOD Removed spider that was preventing buckets from tipping TA9M Current: None Added: None Resolved: #5658 MIAM Tightened wires to sensor WS2M Current: #5857 MADI Stuck at 0 Added: None Resolved: #5784 STIL Replaced sensor with noisy bearings TS10 Current: None Added: None Resolved: None TB10 Current: #5885 DURA Many erratic data dips Added: None Resolved: #5762 WIST Corrected erosion problem #5764 TALI Corrected erosion problem #5665 APAC Replaced defective sensor TS05 Current: #5756 SLAP Sod is consistently warmer than bare plot #5858 HOLL Sod is consistently warmer than bare plot Added: None Resolved: None TB05 Current: #5859 ARDM Data suggests sensor is sticking out of ground Added: None Resolved: #5761 WIST Corrected erosion problem #5763 TALI Corrected erosion problem TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #5714 A156 Replaced lightning-damaged sensor SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5669 B123 Replaced defective switch TS05 Current: None Added: None Resolved: #5725 A111 Replaced defective sensor TS10 Current: None Added: None Resolved: #5671 A125 Replaced defective sensor TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: #5726 A135 Replaced defective sensor #5717 A134 Replaced defective sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2001 | 0000 | 07/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - July 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the July 2001 Oklahoma Mesonet data. Notes: Northwest and southwest Oklahoma were the hot spots of the state during July. Average 1800 UTC temperatures in those areas were over 36 C (97 F). The 1800 UTC pressure data revealed corresponding localized areas of low pressure (heat lows) in those same areas. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #5772 STIL Replaced bad sensor #5950 BRIS Replaced bad sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #5898 VANO Initial install of barometer SRAD Current: None Added: None Resolved: #5927 MARS Replaced sensor with high bias #6002 BUTL Replaced sensor with low bias RAIN Current: #6006 GOOD Soil moisture detected rainfall, but gauge did not Added: None Resolved: #5778 STIL Fixed double-counting gauge TA9M Current: None Added: None Resolved: #5658 MIAM Tightened wires to sensor WS2M Current: None Added: None Resolved: #5870 WEBB Replaced sensor with noisy bearings #5877 NEWK Replaced sensor with high starting threshold #5857 MADI Replaced dead sensor TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: #5885 DURA Tightened wire to correct erratic data TS05 Current: #5756 SLAP Sod is consistently warmer than bare plot Added: None Resolved: #5858 HOLL Corrected erosion problem TB05 Current: #5859 ARDM Data suggests sensor is sticking out of ground Added: None Resolved: #5859 ARDM Replaced sensor with high bias TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #5983 A133 Replaced sensor with high bias RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: #5909 A166 Replaced defective sensor #5966 A130 Replaced sensor with 6 C warm bias TS10 Current: #6000 A148 Sensor spiking to 50 C #6001 A125 Sensor spiking to 70 C Added: None Resolved: #5926 A159 Replaced gopher-damaged sensor #5910 A125 Replaced defective sensor TS15 Current: None Added: None Resolved: #5956 A159 Replaced gopher-damaged sensor #5963 A125 Replaced defective sensor #5965 A155 Replaced defective sensor TS30 Current: #5998 A130 Sensor dipping below 0 C #5999 A154 Sensor has a 10 C cool bias #6004 A122 Sensor reporting erratically and out of range Added: None Resolved: #5726 A135 Replaced defective sensor #5717 A134 Replaced defective sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/01/2001 | 0000 | 08/31/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - August 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the August 2001 Oklahoma Mesonet data. ============================================================== Notes: Mesonet technicians were busy performing Summer Pass 2001 during August. Just a few of their tasks include: trimming vegetation, cleaning sensors, rotating sensors, and performing sensor tests. Summer Pass will be completed October 1. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: #6036 ALTU Reporting multiple data dips #6053 MARE Reporting multiple data spikes Added: None Resolved: None SRAD Current: #6081 FAIR Reporting values over 600 W/m^2 at night Added: None Resolved: None RAIN Current: None Added: None Resolved: #6033 OKMU Replaced bad switch #6034 CLAR Replaced bad switch #6050 CHER Cleaned dirty gauge TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: #6054 CHAN Sod plot is 4 C warmer than bare plot #6064 ADAX TS05 is consistently cooler than TS10 Added: None Resolved: None TB05 Current: None Added: None Resolved: #6055 ALV2 Repaired erosion TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #6023 A181 Replaced lightning-damaged sensor RAIN Current: None Added: None Resolved: #6017 A154 Replaced bad switch #6018 A132 Replaced suspect switch #6030 A162 Replaced suspect switch TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #6000 A148 Replaced bad sensor #6001 A125 Replaced bad sensor TS15 Current: None Added: None Resolved: #6015 A154 Replaced damaged sensor TS30 Current: None Added: None Resolved: #5998 A130 Replaced defective sensor #5999 A154 Replaced defective sensor #6004 A122 Replaced dead sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/01/2001 | 0000 | 09/30/2001 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - September 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the September 2001 Oklahoma Mesonet data. ============================================================== Notes: The Mesonet technicians completed Summer Pass 2001 in late September. Just a few of their accomplishments during this pass include: * 1500 site photos taken to document the stations * 95 sensors rotated * All rain gauges tested * All soil temperature depths verified =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #6036 ALTU Replaced erratic barometer #6053 MARE Removed obstructions from baro tube SRAD Current: None Added: None Resolved: #6081 FAIR Replaced bad pyranometer RAIN Current: None Added: None Resolved: #6082 ADAX Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #6089 ALTU Replaced due to bad bearings #6104 IDAB Replaced due to bad bearings TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: #6064 ADAX Replaced bad sensor TB05 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2001 | 0000 | 11/30/2001 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - November 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the November 2001 Oklahoma Mesonet data. ============================================================== Notes: A new Mesonet site located near Inola, OK was installed on 14 November 2001. The new station's 4-letter identifier is INOL. This site measures all of the core Mesonet parameters. Bill Wyatt and Thomas Smith completed the rotation of all wind monitors in the northwest section of the state during November. ============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #6181 REDR Replaced suspect sensor #6187 SEIL Replaced suspect sensor #6188 CHER Replaced sensor reaching 103-106% during periods of high relative humidity WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #6192 WIST Replaced erratic pyranometer RAIN Current: #6231 COOK Gauge continued to report tips after snow melt #6232 BEEX Gauge stuck at 0 for rain events Added: None Resolved: #6191 CHER Replaced gauge that failed drip test #6207 MINC Replaced rusty screws on terminal strip that caused missing tips TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: #6254 RING Monthly QA indicates 2 C cool bias Resolved: None TB10 Current: None Added: None Resolved: #6165 TISH Tightened wires that had caused erratic observations TS05 Current: #6146 FAIR Sensor stuck at -46 C Added: None Resolved: None TB05 Current: None Added: None Resolved: #6206 WASH Corrected 1 cm of soil erosion TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #6208 A133 Removed spider web that prevented tips from occurring TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/2001 | 0000 | 12/31/2001 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - December 2001 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Janet Martinez, the Mesonet QA manager of the automated quality assurance results for the December 2001 Oklahoma Mesonet data. ============================================================== Notes: The Mesonet Technicians completed the Fall Pass 2001 in late December. Over 1800 site photos were taken. We are preparing a CD that will contain all photos, accomplishments, site visitation forms and special findings. The CD will be available next month. The Technicians also resolved 59 trouble tickets in December! In addition to the tickets shown in this report, their work included scheduled rotations of wind monitors and soil temperature sensors, as well as replacements of site batteries and rain gauge switches. The monthly analysis identified the site with the maximum rainfall. Mt. Herman received 11.8 inches in December, with 7.8 inches falling in a single day (December 16)! In late November, a widespread freezing rain event impacted southern and eastern Oklahoma. The wind data from 27 stations were deemed erroneous and appropriately flagged in the database. ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #6259 RETR Frequent erratic dips in data Added: None Resolved: #6260 PAUL Replaced sensor reaching 114% relative humidity WDIR Current: None Added: None Resolved: #6261 KENT Fixed wiring problem #6262 BOIS Fixed wiring problem #6263 GOOD Fixed wiring problem #6264 HOOK Fixed wiring problem #6265 BEAV Fixed wiring problem WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: RAIN Current: None Added: None Resolved: #6192 COOK Replaced switch #6232 BEEX Removed spider webs that prevented tips from occurring #6266 TALI Removed spider webs that prevented tips from occurring TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #6230 APAC Replaced sensor with dips to -100 C #6254 RING Replaced suspect sensor TB10 Current: None Added: None Resolved: None TS05 Current: None Added: #6304 WAUR Monthly QA indicates 3 C cool bias Resolved: #6252 INOL Fixed wiring on sensor reporting -219.3 C #6282 RING Replaced suspect sensor TB05 Current: None Added: None Resolved: #6268 ARDM Re-leveled surface to correct depth TS30 Current: None Added: #6305 MANG Monthly QA indicates 5 C cool bias Resolved: #6283 RING Replaced suspect sensor ------------------------------------------------------------------------ ARS QA REPORT ------------------------------------------------------------------------ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #6257 A163 Replaced switch on gauge that failed drip test #6270 A156 Removed webbing between funnel and buckets #6302 A154 Replaced switch on gauge that failed drip test TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #6258 A110 Replaced sensor damaged by rodent TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 09/28/2003 | 2359 |
Subject: | SGP/OKM/X1 - Station Change |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | The Mesonet station near Marshall was moved on September 25, 2003 to improve accessiblity for the Mesonet technicians who visit and maintain the site. The new site has the code MRSH. It replaces the old Marshall site that had the code MARS. Since the latitude and longitude of the stations are included in the cdf file, users of these data should not have a problem. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
sgpokmX1.01:
|