DQR ID | Subject | Data Streams Affected |
---|---|---|
D050808.3 | TWP/SMET/C3 - Data not representative | twpsmet60sC3.b1 |
D050831.4 | TWP/SMET/C3 - Towrr lowered for sensor comparisons, data not representative | twpsmet60sC3.b1 |
D050919.4 | TWP/GNDRAD/C3 - Tower inverted for instrument testing and replacement | twpgndrad60sC3.b1 |
D051202.3 | TWP/SKYRAD/C3 - Reprocess: Incorrect datalogger program affecting PIR1 and PIR2 downwelling longwave | twpskyrad60sC3.b1 |
D060630.33 | TWP/SKYRAD/C3 - Reprocess: Longwave Calibration error | twpskyrad60sC3.b1 |
D060630.36 | TWP/GNDRAD/C3 - Reprocess: Longwave Calibration error | twpgndrad60sC3.b1 |
D060818.3 | TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa | twpsmet60sC3.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2005 | 0030 | 08/05/2005 | 0330 |
Subject: | TWP/SMET/C3 - Data not representative |
DataStreams: | twpsmet60sC3.b1 |
Description: | Tower was lowered for radiometer change and characterization. Wind, temp and RH data not representative of local conditions. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2005 | 0030 | 08/05/2005 | 0330 |
Subject: | TWP/SMET/C3 - Towrr lowered for sensor comparisons, data not representative |
DataStreams: | twpsmet60sC3.b1 |
Description: | The tower was lowered for radiometer change and comparisons. During the time period the data listed was not representative. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2005 | 0030 | 08/05/2005 | 0200 |
08/09/2005 | 0000 | 08/09/2005 | 0200 |
Subject: | TWP/GNDRAD/C3 - Tower inverted for instrument testing and replacement |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The tower at Darwin was brought down to test and replace the Gndrad PIR on 8/5/2005 and the PSP on 8/9/2005 |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/21/2004 | 0000 | 09/09/2005 | 2012 |
Subject: | TWP/SKYRAD/C3 - Reprocess: Incorrect datalogger program affecting PIR1 and PIR2 |
DataStreams: | twpskyrad60sC3.b1 |
Description: | The excitation delays using in measuring the PIR1 case thermistor commonly named "Case1" and the PIR2 dome thermistor called "Dome2" were discovered to have been incorrectly set to 0 in the Skyrad datalogger program when the new CR23X based Skyrad loggers were installed. The result of no delay in these measurements results in an error in the measured resistance of the thermistors, Case1 and Dome2, and thus the calculated PIR1 and PIR2 irradiances. The errors are inversely proportial to temperature. Users can apply temperature dependent irradiance corrections as shown in the table below. Recall that the reported uncertainty of PIRs is typically +-.25% to +-.5% or 1 to 2 W/m2. The error corrections become the same order of magnitude or larger than the instrument uncertainties at or below 260K or 9F. Irradiance Correction Table for Skyrad (TWP and NSA) DIR1 and DIR2 Irradiance DIR1 DIR1 DIR2 DIR2 T[F] Tcase[K] Correction[W/m2] Tdome[K] Correction[W/m2] 109.4 316.13 0.00 316.13 0.00 100.5 311.20 -0.15 311.20 0.12 93.2 307.14 -0.12 307.14 0.10 87.0 303.70 -0.10 303.70 0.08 81.6 300.70 -0.17 300.70 0.14 77.0 298.15 -0.22 298.15 0.18 59.4 288.35 -0.34 288.35 0.27 47.4 281.72 -0.23 281.72 0.18 38.5 276.74 -0.42 276.74 0.34 31.3 272.77 -0.48 272.77 0.38 25.4 269.48 -0.61 269.48 0.49 20.3 266.67 -0.67 266.67 0.54 16.0 264.25 -0.82 264.25 0.66 12.1 262.11 -0.98 262.11 0.79 8.7 260.19 -0.97 260.19 0.78 5.6 258.46 -1.07 258.46 0.86 2.7 256.89 -1.17 256.89 0.94 0.1 255.44 -1.33 255.44 1.07 -2.3 254.11 -1.41 254.11 1.13 -4.5 252.87 -1.43 252.87 1.15 -6.6 251.71 -1.52 251.71 1.22 -8.5 250.63 -1.63 250.63 1.31 -10.4 249.62 -1.73 249.62 1.39 -12.2 248.58 -1.79 248.58 1.44 -15.4 246.82 -1.93 246.82 1.55 -18.3 245.23 -2.05 245.23 1.65 -20.9 243.78 -2.22 243.78 1.78 -23.3 242.44 -2.36 242.44 1.89 -25.5 241.21 -2.58 241.21 2.07 -27.5 240.07 -2.65 240.07 2.13 -29.5 239.01 -2.75 239.01 2.21 -31.3 238.00 -3.02 238.00 2.42 |
Measurements: | twpskyrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2004 | 2200 | 12/21/2005 | 2136 |
Subject: | TWP/SKYRAD/C3 - Reprocess: Longwave Calibration error |
DataStreams: | twpskyrad60sC3.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | twpskyrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2004 | 0100 | 12/21/2005 | 2137 |
Subject: | TWP/GNDRAD/C3 - Reprocess: Longwave Calibration error |
DataStreams: | twpgndrad60sC3.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/02/2003 | 0000 | 07/13/2006 | 2219 |
Subject: | TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa |
DataStreams: | twpsmet60sC3.b1 |
Description: | Barometric pressure data was converted from hPa to kPa in order to standardize the measurement units among ARM sites and to conform to accepted standard units determined by the scientific community. |
Measurements: | twpsmet60sC3.b1:
|