DQR ID | Subject | Data Streams Affected |
---|---|---|
D040227.3 | SGP/SIRS/E2 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE2.00, sgpsirsE2.b1 |
D040831.1 | SGP/SIRS/E1 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE1.00, sgpsirsE1.b1 |
D060630.10 | SGP/SIRS/E2 - Reprocess: Longwave Calibration error | sgpsirsE2.b1 |
D060630.12 | SGP/SIRS/E4 - Reprocess: Longwave Calibration error | sgpsirsE4.b1 |
D060630.13 | SGP/SIRS/E5 - Reprocess: Longwave Calibration error | sgpsirsE5.b1 |
D060630.14 | SGP/SIRS/E6 - Reprocess: Longwave Calibration error | sgpsirsE6.b1 |
D060630.9 | SGP/SIRS/E1 - Reprocess: Longwave Calibration error | sgpsirsE1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/12/2004 | 1612 | 03/25/2004 | 1600 |
Subject: | SGP/SIRS/E2 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE2.00, sgpsirsE2.b1 |
Description: | During the pyrgeometer instrument (PIR) changout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements were : downwelling diffuse (DD), upwelling shortwave(US), direct normal (NIP) and downwelling shortwave(DS) Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*118.11 US(corrected) = (US/113.19)*118.21 NIP(corrected)= (NIP/120.17)*119.08 DS(corrected) = (DS/118.46)*117.33 |
Measurements: | sgpsirsE2.b1:
sgpsirsE2.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/10/2004 | 2050 | 04/20/2004 | 2015 |
Subject: | SGP/SIRS/E1 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE1.00, sgpsirsE1.b1 |
Description: | During the pyrgeometer instrument (PIR) changout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements (instruments) were : downwelling diffuse (8-48), upwelling shortwave(PSP), direct normal (NIP) and downwelling shortwave (PSP) Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*109.01 US(corrected) = (US/113.19)*111.47 NIP(corrected)= (NIP/120.17)*114.82 DS(corrected) = (DS/118.46)*116.51 |
Measurements: | sgpsirsE1.b1:
sgpsirsE1.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/12/2004 | 1630 | 02/23/2005 | 1615 |
Subject: | SGP/SIRS/E2 - Reprocess: Longwave Calibration error |
DataStreams: | sgpsirsE2.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | sgpsirsE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/10/2004 | 1720 | 02/22/2006 | 1615 |
Subject: | SGP/SIRS/E4 - Reprocess: Longwave Calibration error |
DataStreams: | sgpsirsE4.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | sgpsirsE4.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/10/2004 | 2030 | 02/22/2006 | 1817 |
Subject: | SGP/SIRS/E5 - Reprocess: Longwave Calibration error |
DataStreams: | sgpsirsE5.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | sgpsirsE5.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/11/2004 | 1610 | 02/09/2006 | 1553 |
Subject: | SGP/SIRS/E6 - Reprocess: Longwave Calibration error |
DataStreams: | sgpsirsE6.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | sgpsirsE6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/10/2004 | 2055 | 02/21/2006 | 2007 |
Subject: | SGP/SIRS/E1 - Reprocess: Longwave Calibration error |
DataStreams: | sgpsirsE1.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | sgpsirsE1.b1:
|