Subject: | SGP/EBBR/E27 - Instrument problem, Loose connections |
DataStreams: | sgp15ebbrE27.b1, sgp30ebbrE27.b1
|
Description: | The soil heat flow #1 sensor went offscale low on occasion. This sometimes caused
sensible and latent heat fluxes to be 9999ed out by the EBBR programming, but not always. |
Suggestions: | |
Measurements: | sgp15ebbrE27.b1: - Soil heat flow 1 (mV)(soil_heat_flow_1_mv)
more
sgp30ebbrE27.b1: - Soil heat flow 1, corrected for soil moisture(corr_soil_heat_flow_1)
- Surface soil heat flux 1(surface_soil_heat_flux_1)
- Soil heat flow 1(soil_heat_flow_1)
- Surface sensible heat flux(sensible_heat_flux)
- Surface latent heat flux(latent_heat_flux)
more
|