Data Quality Reports for Session: 181698 User: lkberg Completed: 11/23/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D120716.1PVC/MET/M1 - Tower loweredpvcmetM1.b1Suspect
D121102.1PVC/MET/M1 - False positive precipitationpvcmetM1.b1Suspect
D121218.2PVC/MET/M1 - Tower loweredpvcmetM1.b1Does not affect quality
D130117.4PVC/MET/M1 - PWD data intermittently missingpvcmetM1.b1Missing
D130508.2PVC/MET/M1 - PWD failurepvcmetM1.b1Suspect
D130617.1PVC/MET/M1 - T/RH sensor failurepvcmetM1.b1Incorrect
D130718.5PVC/MET/M1 - Questionable humiditypvcmetM1.b1Suspect


DQRID : D120716.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
07/13/2012123007/13/20121330Suspect
Subject:
PVC/MET/M1 - Tower lowered
DataStreams:pvcmetM1.b1
Description:
Met tower was lowered during this time. Data may be inaccurate.
Measurements:pvcmetM1.b1:
  • wind_spd_arith_max
  • wind_dir_sd
  • wind_spd_arith_min
  • Atmospheric pressure(atmos_pressure)
  • relh_sd
  • wind_spd_arith_sd
  • Pressure, vapor, at 2-m height, 1-min avg(vappress_mean)
  • Wind speed, lower, 1-min avg(wind_spd_arith_avg)
  • Temperature mean(temp_mean)
  • temp_sd
  • Humidity, relative, at 2-m height, 1-min avg(relh_mean)
  • Vector-averaged Wind Speed(wind_spd_vec_avg)
  • Vector-averaged Wind Direction(wind_dir_vec_avg)
  • vappress_sd


Back To Table of Contents

DQRID : D121102.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
08/11/2012000010/25/20121309Suspect
Subject:
PVC/MET/M1 - False positive precipitation
DataStreams:pvcmetM1.b1
Description:
Optical rain gauge recorded significantly more precipitation than expected. Instrument was 
removed/replaced and sent for recalibration.
Measurements:pvcmetM1.b1:
  • org_carrier_mean
  • Rain, surface, 1-min avg(precip_rate_mean)
  • precip_rate_min
  • precip_rate_sd
  • precip_rate_max


Back To Table of Contents

DQRID : D121218.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/30/2012200012/13/20121830Does not affect quality
Subject:
PVC/MET/M1 - Tower lowered
DataStreams:pvcmetM1.b1
Description:
The tower containing the wind sensor was not at full-height of 10 meters following 
Hurricane Sandy.
Measurements:pvcmetM1.b1:
  • wind_spd_arith_max
  • wind_dir_sd
  • wind_spd_arith_min
  • Vector-averaged Wind Speed(wind_spd_vec_avg)
  • Vector-averaged Wind Direction(wind_dir_vec_avg)
  • wind_spd_arith_sd
  • Wind speed, lower, 1-min avg(wind_spd_arith_avg)


Back To Table of Contents

DQRID : D130117.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/29/2012170012/28/20120508Missing
Subject:
PVC/MET/M1 - PWD data intermittently missing
DataStreams:pvcmetM1.b1
Description:
Present weather detector was occasionally reporting a hardware problem during this time. 
The reported error did not affect visibility readings, but caused all other data to report 
as missing. Error resolved its self with no indication of the problem cause.
Measurements:pvcmetM1.b1:
  • pwd_cumul_snow
  • pwd_pw_code_1_hr
  • pwd_avg_H2O_int_1_min
  • pwd_pw_code_inst
  • pwd_pw_code_15_min
  • pwd_cumul_water


Back To Table of Contents

DQRID : D130508.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
01/27/2013041204/15/20131435Suspect
Subject:
PVC/MET/M1 - PWD failure
DataStreams:pvcmetM1.b1
Description:
Lens and rain sensor in present weather detector failed. Data during this time are suspect 
or missing.
Measurements:pvcmetM1.b1:
  • pwd_cumul_snow
  • pwd_pw_code_1_hr
  • Average 10 min visibility(pwd_avg_vis_10_min)
  • pwd_avg_H2O_int_1_min
  • pwd_pw_code_inst
  • pwd_pw_code_15_min
  • pwd_cumul_water
  • Average 1 min visibility(pwd_avg_vis_1_min)


Back To Table of Contents

DQRID : D130617.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/21/2013112505/31/20131255Incorrect
06/03/2013125806/03/20132002Incorrect
Subject:
PVC/MET/M1 - T/RH sensor failure
DataStreams:pvcmetM1.b1
Description:
Temperature, relative humidity, and vapor pressure data are incorrect due to a failed 
sensor. Sensor replacement corrected the problem.
Measurements:pvcmetM1.b1:
  • Humidity, relative, at 2-m height, 1-min avg(relh_mean)
  • vappress_sd
  • relh_sd
  • Pressure, vapor, at 2-m height, 1-min avg(vappress_mean)
  • temp_sd
  • Temperature mean(temp_mean)


Back To Table of Contents

DQRID : D130718.5
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/26/2013180006/29/20131000Suspect
Subject:
PVC/MET/M1 - Questionable humidity
DataStreams:pvcmetM1.b1
Description:
A reference check of the humidity sensor showed that the instrument may have been reading 
as much as 20% high.
Measurements:pvcmetM1.b1:
  • Humidity, relative, at 2-m height, 1-min avg(relh_mean)
  • vappress_sd
  • relh_sd
  • Pressure, vapor, at 2-m height, 1-min avg(vappress_mean)


Back To Table of Contents



END OF DATA