Data Quality Reports for Session: 181083 User: dumask1 Completed: 11/07/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D120831.1SGP/MWR3C/C1 - Possible bias in 89 GHz brightness temperaturessgpmwr3cC1.b1Suspect


DQRID : D120831.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/01/2011000007/22/20120000Suspect
Subject:
SGP/MWR3C/C1 - Possible bias in 89 GHz brightness temperatures
DataStreams:sgpmwr3cC1.b1
Description:
The 89 GHz brightness temperatures appear slightly warm when compared to model 
computations. The bias appear to be about 1.5 K. This could affect the liquid water retrievals that 
may display a slight positive bias.
Measurements:sgpmwr3cC1.b1:
  • 89.0 GHz sky brightness temperature(tbsky89)
  • Liquid water path best-estimate value, hourly mean(lwp)
  • Column precip water vapor(pwv)


Back To Table of Contents