Data Quality Reports for Session: 180063 User: weltyj1 Completed: 09/29/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D080526.1SGP/ECOR/E10 - Incorrect CO2 fluxessgp30ecorE10.b1Incorrect
D080604.2SGP/ECOR/E14 - Sensor failuresgp30ecorE14.b1Suspect


DQRID : D080526.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/10/2008113006/25/20081500Incorrect
Subject:
SGP/ECOR/E10 - Incorrect CO2 fluxes
DataStreams:sgp30ecorE10.b1
Description:
The analog CO2 signal from the LI-7500 to the sonic anemometer became very noisy and 
incorrect CO2 fluxes resulted. Sonic anemometer was replaced.
Measurements:sgp30ecorE10.b1:
  • CO2 flux(fc)


Back To Table of Contents

DQRID : D080604.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
04/02/2008133006/05/20081930Suspect
Subject:
SGP/ECOR/E14 - Sensor failure
DataStreams:sgp30ecorE14.b1
Description:
The water vapor output of the LI-7500 was too low, indicating that water vapor leaked into 
the sensor and that the chemicals are spent or there was an electronic failure.

Latent heat flux was not normally affected by this problem.
Measurements:sgp30ecorE14.b1:
  • Mean H2O density(mean_q)


Back To Table of Contents



END OF DATA