Data Quality Reports for Session: 179506 User: goffinb1 Completed: 09/08/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D071001.1SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensorsgp30ebbrE26.b1Suspect


DQRID : D071001.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
09/28/2007014010/11/20071730Suspect
Subject:
SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor
DataStreams:sgp30ebbrE26.b1
Description:
The left Thum (temperature of the humidity sensor chamber) measurement was incorrect at 
times, affecting several measurements, including the sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • Latent heat flux(latent_heat_flux)
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents



END OF DATA