Data Quality Reports for Session: 179257 User: ql_data Completed: 08/25/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D160523.1SGP/STAMP/E12 - 10 cm South Soil Moisture IncorrectsgpstampE12.b1Incorrect
D160603.4SGP/STAMP/E12 - East Soil Measurements MissingsgpstampE12.b1Missing
D160701.1SGP/STAMP/E15 - 5 cm west measurements too low.sgpstampE15.b1Suspect


DQRID : D160523.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/09/2016190005/18/20161600Incorrect
Subject:
SGP/STAMP/E12 - 10 cm South Soil Moisture Incorrect
DataStreams:sgpstampE12.b1
Description:
10 cm south soil moisture was much too low in comparison with 10 cm east and west 
measurements.
Measurements:sgpstampE12.b1:
  • Plant water availability, south profile(plant_water_availability_south)
  • Soil specific soil water content, south profile(soil_specific_water_content_south)
  • Loam soil water content, south profile(loam_soil_water_content_south)
  • Total plant water availability, south profile(total_plant_water_availability_south)


Back To Table of Contents

DQRID : D160603.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/18/2016160005/31/20161500Missing
Subject:
SGP/STAMP/E12 - East Soil Measurements Missing
DataStreams:sgpstampE12.b1
Description:
Some east profile soil moisture measurements were missing during the period.
Measurements:sgpstampE12.b1:
  • Soil specific soil water content, east profile(soil_specific_water_content_east)
  • Plant water availability, east profile(plant_water_availability_east)
  • Loam soil water content, east profile(loam_soil_water_content_east)
  • Total plant water availability, east profile(total_plant_water_availability_east)
  • Soil temperature, east profile(soil_temperature_east)
  • real_dielectric_permittivity_east
  • soil_conductivity_east


Back To Table of Contents

DQRID : D160701.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/01/2016210006/29/20161600Suspect
Subject:
SGP/STAMP/E15 - 5 cm west measurements too low.
DataStreams:sgpstampE15.b1
Description:
5 cm west soil measurements were generally too low due to a faulty factory calibration, 
and sometimes went offscale low.
Measurements:sgpstampE15.b1:
  • real_dielectric_permittivity_west
  • Plant water availability, west profile(plant_water_availability_west)
  • Soil specific soil water content, west profile(soil_specific_water_content_west)
  • Loam soil water content, west profile(loam_soil_water_content_west)
  • Total plant water availability, west profile(total_plant_water_availability_west)


Back To Table of Contents



END OF DATA