Data Quality Reports for Session: 178824 User: vghate Completed: 08/04/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D120414.6SGP/QCRAD/E16 - Tracker alignment issuesgpqcrad1longE16.s2Incorrect
D120510.28SGP/QCRAD/E16 - Tc/Td bad or noisysgpqcrad1longE16.s2Suspect


DQRID : D120414.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/14/1999150003/24/19992359Incorrect
10/05/1999060010/20/19991400Incorrect
Subject:
SGP/QCRAD/E16 - Tracker alignment issue
DataStreams:sgpqcrad1longE16.s2
Description:
Tracker appears to be out of alignment or inoperative during these times. The 
short_direct_normal (NIP) and down_short_diffuse_hemisp (8-48) data appear to be bad and not 
recoverable.

There were no instrument DQRs on this problem at the time this report was submitted.
Measurements:sgpqcrad1longE16.s2:
  • Irradiance, shortwave, downwelling, diffuse, hemispheric, pyranometer(down_short_diffuse_hemisp)
  • Best Estimate Global Downwelling Shortwave Hemispheric Irradiance(BestEstimate_down_short_hemisp)
  • Irradiance, shortwave, direct normal, pyrheliometer(short_direct_normal)


Back To Table of Contents

DQRID : D120510.28
Start DateStart TimeEnd DateEnd Time Data Quality Metric
12/18/2007190001/16/20081800Suspect
05/01/1990000008/01/19990000Suspect
03/24/2003150004/15/20030300Suspect
04/03/1997150005/07/19971700Suspect
Subject:
SGP/QCRAD/E16  - Tc/Td bad or noisy
DataStreams:sgpqcrad1longE16.s2
Description:
Case and dome temperatures for longwave fluxes are sporadically bad or noisy during these 
periods corresponding to additional noise in the longwave fluxes. Some checks can't be 
applied to the LW fluxes.

No instrument DQRs exist documenting this problem.
Measurements:sgpqcrad1longE16.s2:
  • Downwelling Longwave Hemispheric Irradiance, Pyrgeometer(down_long_hemisp)
  • LWdnTc
  • LWdnTd
  • Radiation, longwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_long_hemisp)
  • LWupTc
  • LWupTd


Back To Table of Contents



END OF DATA