Data Quality Reports for Session: 178642 User: qiuj1 Completed: 07/26/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D050718.2PYE/ECOR/M1 - Reprocessed: Wind direction offset correctedpye30ecorM1.b1Does not affect quality
D080125.4PYE/ECOR/M1 - Flux Data Suspect For Some Wind Directionspye30ecorM1.b1Does not affect quality


DQRID : D050718.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
04/08/2005000007/20/20051748Does not affect quality
Subject:
PYE/ECOR/M1 - Reprocessed: Wind direction offset corrected
DataStreams:pye30ecorM1.b1
Description:
The SMET wind direction was consistently 15 to 20 degrees larger than the wind direction 
determined by the ECOR. The ECOR was mistakenly aligned to magnetic north during this 
period.

The magnetic declination is 14 deg. 58 min., which explains most of the difference.

The ECOR data for this period were reprocessed in November 2006 to add 15 degrees to the 
wind direction.  No other changes were made to the data. The reprocessed data were 
archived in January 2007.
Measurements:pye30ecorM1.b1:
  • wind_dir


Back To Table of Contents

DQRID : D080125.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/01/2005000009/15/20052330Does not affect quality
Subject:
PYE/ECOR/M1 - Flux Data Suspect For Some Wind Directions
DataStreams:pye30ecorM1.b1
Description:
For some wind directions the horizontal fetch was not representative 
of the field in which the AMF was located.  Therefore, for the wind 
direction ranges 66-92 (buildings and trees) degrees, the fluxes are 
affected by insufficient fetch and  surfaces, buildings, or vegetation 
that are not similar to the local field conditions.
Measurements:pye30ecorM1.b1:
  • friction velocity(ustar)
  • Latent heat flux(lv_e)
  • CO2 flux(fc)
  • Corrected sensible heat flux(h)


Back To Table of Contents



END OF DATA