Data Quality Reports for Session: 178455 User: tjphillips Completed: 07/15/2016


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D000214.2SGP/EBBR - EBBR E7 Soil Moisture Jumping Aroundsgp30ebbrE7.b1
D000214.3SGP/EBBR - EBBR E7 Soil Moisture Sensors #2 and #4 Negativesgp30ebbrE7.b1
D000214.4SGP/EBBR - EBBR E7 Soil Moisture Sensor #5 Negativesgp30ebbrE7.b1
D000221.2SGP/EBBR - EBBR E7 Left Aspirator Not Workingsgp30ebbrE7.b1
D000221.6SGP/EBBR - EBBR E9 Anemometer Frozen, Wind Speed Incorrectsgp30ebbrE9.b1
D000224.10SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.11SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.12SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.13SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.14SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.15SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.16SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.17SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.5SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.6SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.7SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.8SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000224.9SGP/EBBR - EBBR E7 Soil Moisture Spikesgp30ebbrE7.b1
D000225.9SGP/EBBR - EBBR E7 Soil Heat Flows Spikedsgp30ebbrE7.b1
D000229.1SGP/EBBR - EBBR E7 Soil Moistures #2 and #4 Incorrectsgp30ebbrE7.b1
D000301.7SGP/EBBR - EBBR E7 Net Radiation Incorrectsgp30ebbrE7.b1
D000301.8SGP/EBBR - EBBR E9 Net Radiation Incorrectsgp30ebbrE9.b1
D010213.16SGP/EBBR/E7 - EBBR E7 Wind Speed Icedsgp30ebbrE7.b1
D010316.148SGP/EBBR/E7 - E7 EBBR Datalogger Replacement/Upgrade - Data Incorrectsgp30ebbrE7.b1
D010316.149SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.150SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.151SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.152SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.153SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.154SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.155SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.156SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.157SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.158SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.159SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.160SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.161SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.162SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrectsgp30ebbrE7.b1
D010316.163SGP/EBBR/E7 - E7 EBBR Right Aspirator Replacementsgp30ebbrE7.b1
D010316.164SGP/EBBR/E7 - E7 EBBR Left Aspirator Fan Not Workingsgp30ebbrE7.b1
D010316.165SGP/EBBR/E7 - E7 EBBR Net Radiometer Dome Replacementsgp30ebbrE7.b1
D010316.166SGP/EBBR/E7 - E7 EBBR All Data Incorrectsgp30ebbrE7.b1
D010316.167SGP/EBBR/E7 - E7 EBBR All Data Incorrectsgp30ebbrE7.b1
D010316.168SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikessgp30ebbrE7.b1
D010316.169SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikessgp30ebbrE7.b1
D010316.170SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikessgp30ebbrE7.b1
D010316.171SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikessgp30ebbrE7.b1
D010316.172SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikessgp30ebbrE7.b1
D010316.173SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikessgp30ebbrE7.b1
D010316.174SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikessgp30ebbrE7.b1
D010316.175SGP/EBBR/E7 - E7 EBBR Soil Temperature #4 Incorrectsgp30ebbrE7.b1
D010319.31SGP/EBBR/E7 - E7 EBBR AEM Frozen Stoppedsgp30ebbrE7.b1
D010319.32SGP/EBBR/E7 - E7 EBBR AEM Frozen Stoppedsgp30ebbrE7.b1
D010319.33SGP/EBBR/E7 - E7 EBBR AEM Frozen Stoppedsgp30ebbrE7.b1
D010319.34SGP/EBBR/E7 - E7 EBBR AEM Frozen Stoppedsgp30ebbrE7.b1
D010319.35SGP/EBBR/E7 - E7 EBBR AEM Frozen Stoppedsgp30ebbrE7.b1
D010319.36SGP/EBBR/E7 - E7 EBBR AEM Frozen Stoppedsgp30ebbrE7.b1
D010319.37SGP/EBBR/E7 - E7 EBBR AEM Frozen Stoppedsgp30ebbrE7.b1
D010319.40SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrectsgp30ebbrE7.b1
D010319.41SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrectsgp30ebbrE7.b1
D010319.42SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrectsgp30ebbrE7.b1
D010319.43SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrectsgp30ebbrE7.b1
D010319.44SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrectsgp30ebbrE7.b1
D010319.45SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrectsgp30ebbrE7.b1
D010319.46SGP/EBBR/E7 - E7 EBBR Soil Moistures 2, 4, and 5 Incorrectsgp30ebbrE7.b1
D010319.50SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrectsgp30ebbrE7.b1
D010319.51SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrectsgp30ebbrE7.b1
D010319.52SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrectsgp30ebbrE7.b1
D010319.53SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrectsgp30ebbrE7.b1
D010319.54SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrectsgp30ebbrE7.b1
D010319.55SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrectsgp30ebbrE7.b1
D010319.56SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrectsgp30ebbrE7.b1
D010319.57SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrectsgp30ebbrE7.b1
D010319.58SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrectsgp30ebbrE7.b1
D010319.59SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrectsgp30ebbrE7.b1
D010319.60SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrectsgp30ebbrE7.b1
D010319.61SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.62SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.63SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.64SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.65SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.66SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.67SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.68SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.69SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.70SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.71SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.72SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.73SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.74SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.75SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.76SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.77SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.78SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.79SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010319.80SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrectsgp30ebbrE7.b1
D010402.1SGP/EBBR/E9 - E9 EBBR Wind Direction Incorrectsgp30ebbrE9.b1
D010402.2SGP/EBBR/E9 - E9 EBBR Wind Speed Incorrectsgp30ebbrE9.b1
D010402.3SGP/EBBR/E9 - E9 EBBR Soil Heat Flow 1 Incorrectsgp30ebbrE9.b1
D010402.5SGP/EBBR/E9 - E9 EBBR Soil Heat Capacities Incorrectsgp30ebbrE9.b1
D011127.23SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checkssgp30ebbrE7.b1
D011127.25SGP EBBR E9 - E9 EBBR Data Incorect During 6 Month Checkssgp30ebbrE9.b1
D011129.2SGP EBBR E7 - E7 EBBR Data Incorrectsgp30ebbrE7.b1
D011129.3SGP EBBR E7 - E7 EBBR Soil Moisture #3 and Other Data Incorrectsgp30ebbrE7.b1
D011129.4SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Datasgp30ebbrE7.b1
D011129.5SGP EBBR E7 - E7 EBBR Soil Moisture #2 Spiked, Incorrect Data Resultedsgp30ebbrE7.b1
D011129.6SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Datasgp30ebbrE7.b1
D011129.7SGP EBBR E7 - E7 EBBR All Data Incorrectsgp30ebbrE7.b1
D011129.8SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibrationsgp30ebbrE7.b1
D011129.9SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Periodsgp30ebbrE7.b1
D011221.2SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrectsgp30ebbrE9.b1
D011221.3SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrectsgp30ebbrE9.b1
D011221.4SGP EBBR E9 - E9 EBBR Wind Speed Frozen Stoppedsgp30ebbrE9.b1
D011221.5SGP EBBR E9 - E9 EBBR Wind Direction Frozen In One Directionsgp30ebbrE9.b1
D011221.6SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrectsgp30ebbrE9.b1
D011221.8SGP EBBR E9 - E9 EBBR Gradients Incorrect During Sensor Replacementsgp30ebbrE9.b1
D020110.2SGP EBBR E9 - E9 EBBR Right Air Temperature Incorrectsgp30ebbrE9.b1
D020628.11SGP/EBBR/E7 - T/RH Checksgp30ebbrE7.b1
D020628.14SGP/EBBR/E9 - T/RH Checksgp30ebbrE9.b1
D020628.8SGP/EBBR/E7 - 3-month Checksgp30ebbrE7.b1
D020716.1SGP/EBBR/E9 - Annual calibration changeoutsgp30ebbrE9.b1
D020716.10SGP/EBBR/E9 - 6 Month Checkssgp30ebbrE9.b1
D020716.2SGP/EBBR/E9 - Annual calibration changeoutsgp30ebbrE9.b1
D020716.26SGP/EBBR/E7 - Measurements Zerosgp30ebbrE7.b1
D020716.27SGP/EBBR/E7 - AEM Hungsgp30ebbrE7.b1
D020716.28SGP/EBBR/E7 - Wind Speed Incorrectsgp30ebbrE7.b1
D020716.8SGP/EBBR/E7 - 6 Month Checkssgp30ebbrE7.b1
D020717.2SGP/EBBR/E9 - Reprocess: Soil Temperature #5 Incorrectsgp30ebbrE9.b1
D020717.3SGP/EBBR/E9 - Measurements All Zerossgp30ebbrE9.b1
D020717.4SGP/EBBR/E9 - Humidity Probe Measurements Incorrectsgp30ebbrE9.b1
D020717.5SGP/EBBR/E9 - Right Humidity Suspectsgp30ebbrE9.b1
D021113.1SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE9.b1, sgp30ebbrE7.b1
D021113.2SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30baebbrE7.c1, sgp30baebbrE9.c1
D021113.4SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE7.b1, sgp30ebbrE9.b1
D030110.30SGP/EBBR/E7 - Data Incorrect during 6 month checkssgp30ebbrE7.b1
D030110.32SGP/EBBR/E9 - Data Incorrect during 6 month checkssgp30ebbrE9.b1
D030113.1SGP/EBBR/E7 - Wind speed incorrectsgp30ebbrE7.b1
D030113.3SGP/EBBR/E7 - CES data incorrectsgp30ebbrE7.b1
D030113.4SGP/EBBR/E7 - Reprocess: Soil Heat Flow #2 Incorrectsgp30ebbrE7.b1
D030113.5SGP/EBBR/E7 - Change In Energy Storage Calculations Incorrectsgp30ebbrE7.b1
D030113.6SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #5 too lowsgp30ebbrE7.b1
D030113.7SGP/EBBR/E7 - AEM Problemssgp30ebbrE7.b1
D030113.8SGP/EBBR/E7 - T/RH Ventilator Fans Stoppedsgp30ebbrE7.b1
D030114.2SGP/EBBR/E7 - Data Reported as Zero following Logger Replacementsgp30ebbrE7.b1
D030114.5SGP/EBBR/E9 - Reprocess: Soil Temperature #5 Incorrectsgp30ebbrE9.b1
D030114.6SGP/EBBR/E9 - Reprocess: Soil Heat Flow #4 Incorrectsgp30ebbrE9.b1
D030114.8SGP/EBBR/E9 - Net Rad data bad during dome replacementsgp30ebbrE9.b1
D030114.9SGP/EBBR/E9 - AEM Malfunctionsgp30ebbrE9.b1
D030620.1SGP/EBBR/E7 - Soil Heat Flow #5 Incorrectsgp30ebbrE7.b1
D030712.1SGP/EBBR/E9 - AEM Hung Inbetween Home Positionssgp30ebbrE9.b1
D030712.13SGP/EBBR/E7 - 6 Month Checkssgp30ebbrE7.b1
D030712.15SGP/EBBR/E9 - 6 Month Checkssgp30ebbrE9.b1
D030712.2SGP/EBBR/E9 - Soil Heat Flow #1 Incorrectsgp30ebbrE9.b1
D030712.3SGP/EBBR/E9 - Battery Voltage Lowsgp30ebbrE9.b1
D030712.9SGP/EBBR/E7 - AEM Hung Inbetween Home Positionsgp30ebbrE7.b1
D030729.2SGP/EBBR/E9 - AEM Hung in home 30 position.sgp30ebbrE9.b1
D030729.3SGP/EBBR/E7 - AEM Malfunction, Some Data Incorrectsgp30ebbrE7.b1
D030917.2SGP/EBBR/E7 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrectsgp30ebbrE7.b1
D030919.1SGP/EBBR/E7 - Data all zerosgp30ebbrE7.b1
D030919.2SGP/EBBR/E7 - Energy Storage Incorrect, Fluxes Incorrectsgp30ebbrE7.b1
D030919.3SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrectsgp30ebbrE7.b1
D030919.7SGP/EBBR/E9 - Water in Net Radiometer; Surface Fluxes are Incorrectsgp30ebbrE9.b1
D031031.1SGP/EBBR/E7 - Reference Temperature Failuresgp30ebbrE7.b1
D031031.3SGP/EBBR/E9 - Measurements All Zerosgp30ebbrE9.b1
D031204.6SGP/EBBR/E7 - 6 Month Checkssgp30ebbrE7.b1
D031204.8SGP/EBBR/E9 - 6 Month Checkssgp30ebbrE9.b1
D031211.6SGP/EBBR/E7 - Pressure Sensor Data Incorrectsgp30ebbrE7.b1
D031222.13SGP/EBBR/E9 - Net Radiometer Iced Over During Stormsgp30ebbrE9.b1
D031222.14SGP/EBBR/E9 - Wind Speed Sensor Frozen By Ice Stormsgp30ebbrE9.b1
D031222.9SGP/EBBR/E7 - Wind Speed Sensor Frozen By Ice Stormsgp30ebbrE7.b1
D040206.3SGP/EBBR/E7 - Pressure Sensor Data Incorretsgp30ebbrE7.b1
D040304.3SGP/EBBR/E7 - Wind Speed Frozen Stopped By Icesgp30ebbrE7.b1
D040304.4SGP/EBBR/E7 - Tref Problem Causes All Temps. to be Incorrectsgp30ebbrE7.b1
D040304.8SGP/EBBR/E9 - Wind Speed Frozen Stopped By Icesgp30ebbrE9.b1
D040304.9SGP/EBBR/E9 - Wind Direction Frozen Stopped By Icesgp30ebbrE9.b1
D040723.2SGP/EBBR/E9 - net radiometer top dome broken, water in bottom domesgp30ebbrE9.b1
D040813.8SGP/EBBR/E7 - Pressure Too Highsgp30ebbrE7.b1
D041005.3SGP/EBBR/E7 - Data Missingsgp30ebbrE7.b1
D041222.10SGP/EBBR/E9 - 6 Month Checkssgp30ebbrE9.b1
D041222.8SGP/EBBR/E7 - 6 Month Checkssgp30ebbrE7.b1
D050113.2SGP/EBBR/E9 - Wind Speed Threshhold Lowsgp30ebbrE9.b1
D050114.7SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9 - BA EBBR VAP Bulk Aerodynamicssgp30baebbrE9.c1, sgp30baebbrE7.c1
D050206.6SGP/EBBR/E7 - Wind Speed Frozen Stopped By Ice Stormsgp30ebbrE7.b1
D050206.8SGP/EBBR/E9 - Wind Speed Frozen Stopped By Ice Stormsgp30ebbrE9.b1
D050207.4SGP/EBBR/E9 - Wind Direction Frozen Stopped By Ice Stormsgp30ebbrE9.b1
D050215.11SGP/EBBR/E7 - Wind Speed Frozen Stopped By Icesgp30ebbrE7.b1
D050215.14SGP/EBBR/E9 - Wind Direction Frozen Stopped By Icesgp30ebbrE9.b1
D050215.15SGP/EBBR/E9 - Wind Speed Frozen Stopped By Icesgp30ebbrE9.b1
D050330.2SGP/EBBR/E7 - Wrong Datalogger Programsgp30ebbrE7.b1
D050601.2SGP/EBBR/E9 - Soil moisture too highsgp30ebbrE9.b1
D050719.6SGP/EBBR/E7 - Improved EBBR CR10 Programsgp30ebbrE7.b1
D050719.8SGP/EBBR/E9 - Improved EBBR CR10 Programsgp30ebbrE9.b1
D051024.1SGP/EBBR/E7 - Data Missingsgp30ebbrE7.b1
D051104.1SGP/EBBR/E9 - Net Radiation Incorrect: Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D051106.20SGP/EBBR/E7 - Average Soil Heat Flux Incorrectsgp30ebbrE7.b1
D051106.22SGP/EBBR/E9 - Average Soil Heat Flux Incorrectsgp30ebbrE9.b1
D051106.3SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE7.b1
D051112.4SGP/EBBR/E7 - metadata correctionssgp30ebbrE7.b1
D051112.6SGP/EBBR/E9 - metadata correctionssgp30ebbrE9.b1
D051215.2SGP/EBBR/E9 - Net Radiation, Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D060111.3SGP/EBBR/E7 - Barometric Pressure Incorrectsgp30ebbrE7.b1
D060501.4SGP/EBBR/E7 - Fluxes and Gradient Measurements Incorrectsgp30ebbrE7.b1
D060621.7SGP/EBBR/E9 - Wind Speed Incorrectsgp30ebbrE9.b1
D070215.3SGP/EBBR/E7 - Windspeed threshhold too highsgp30ebbrE7.b1
D080102.2SGP/EBBR/E9 - Net Radiation Incorrectsgp30ebbrE9.b1
D080212.1SGP/EBBR/E7 - Wind Speed Frozen Stoppedsgp30ebbrE7.b1
D090312.2SGP/EBBR/E7 - AEM voltage too highsgp30ebbrE7.b1
D090313.11SGP/EBBR/E9 - Wind Speed Incorrectsgp30ebbrE9.b1
D090428.1SGP/EBBR/E7 - Fluxes intermittently incorrectsgp30ebbrE7.b1
D090617.3SGP/EBBR/E7 - Wind direction incorrectsgp30ebbrE7.b1
D100202.2SGP/EBBR/E7 - Wind speed frozen stoppedsgp30ebbrE7.b1
D100521.2SGP/EBBR/E9 - Sensible and latent heat flux incorrectsgp30ebbrE9.b1
D100727.4SGP/EBBR/E7 - Incorrect Sensible and Latent Heat Fluxessgp30ebbrE7.b1
D101007.3SGP/EBBR/E7 - Sensible and latent heat fluxes incorrect - soil heat flow 1 problemsgp30ebbrE7.b1
D101127.1SGP/EBBR/E9 - T/RH Probe Temperature Problem - Sensible and Latent Heat Fluxes Affectedsgp30ebbrE9.b1
D110105.4SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D110830.2SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D110830.3SGP/EBBR/E7 - Loose connection (ST #3)sgp30ebbrE7.b1
D111011.2SGP/EBBR/E7 - Sensible and Latent Heat Flux Incorrectsgp30ebbrE7.b1
D130114.1SGP/EBBR/E9 - Sensible and latent heat flux sometimes incorrectsgp30ebbrE9.b1
D130410.1SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D130410.2SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D130410.3SGP/EBBR/E9 - AEM hungsgp30ebbrE9.b1
D130423.3SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D141010.5SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D141103.2SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D151113.4SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D151201.2SGP ALL INSTRUMENTS - Icing Eventsgp30baebbrE9.c1, sgp30ebbrE9.b1
D160603.2SGP/EBBR/E9 - Data Missing or Incorrectsgp30ebbrE9.b1
D931108.6SGP/EBBR/E9 - pressure calibrationsgp30ebbrE9.b1
D940301.4Invalid wind speed frozen sensorsgp30ebbrE7.b1
D940301.6SGP/EBBR/E9 - Invalid wind speed frozen sensorsgp30ebbrE9.b1
D940329.3SGP/E9/EBBR - AEM Malfunctionsgp30ebbrE9.b1
D940503.1SGP/EBBR/E9 - AEM failuresgp30ebbrE9.b1
D940711.2SGP/EBBR/E9 - Reprocessing Notice (RID 13)sgp30ebbrE9.b1
D940711.4SGP/EBBR/E7 - Reprocess: Soil Temperature Probe Failuresgp30ebbrE7.b1
D940826.1SGP/EBBR/E9 - Malfunctioning Wind Dir Sensor, Incorrect SM2 Resultssgp30ebbrE9.b1
D940826.2SGP/EBBR/E9 - Reprocess: Soil Heat Flux Out of Rangesgp30ebbrE9.b1
D940830.7SGP/EBBR/E9 - Hail Damage to Net Radiometer and Wind Speed Sensorsgp30ebbrE9.b1
D940830.8Stopped Ventilation Fansgp30ebbrE7.b1
D940926.1Intermittent Stopped or Slowed Aspirator Fanssgp30ebbrE7.b1
D941114.3SGP/EBBR/E7 - Net Radiometer not levelsgp30ebbrE7.b1
D941208.2SGP/EBBR/E7 - Radiation Shield Problemsgp30ebbrE7.b1
D941220.3SGP/EBBR/E7 - Water in Net Radiometersgp30ebbrE7.b1
D950126.2SGP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Datasgp30ebbrE9.b1
D950308.2SGP/EBBR/E9 - Radiation Shield Problemsgp30ebbrE9.b1
D950626.11SGP/EBBR/E9 - Stopped Ventilation Fansgp30ebbrE9.b1
D950626.12SGP/EBBR/E9 - Water in Net Radiometersgp30ebbrE9.b1
D950626.6SGP/EBBR/E9 - Frozen Wind Speed Sensorsgp30ebbrE9.b1
D950626.8SBP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Datasgp30ebbrE9.b1
D951020.1SGP/EBBR/E9 - 3-month Checksgp30ebbrE9.b1
D951116.5SGP/EBBR/E9 - AEM Exchange Stopped in Snow and Freezing Rainsgp30ebbrE9.b1
D951127.1SGP/EBBR/E9 - Annual calibration changeoutsgp30ebbrE9.b1
D951221.1Annual calibration changeoutsgp30ebbrE7.b1
D960104.5SGP/EBBR/E7 - Wind Speed Cups Frozensgp30ebbrE7.b1
D960119.5SGP/EBBR/E7 - Soil Moisture Probes Offscalesgp30ebbrE7.b1
D960320.2SGP/EBBR/E7 - Wind Speed Cups Frozensgp30ebbrE7.b1
D960321.1SGP/EBBR/E9 - Wind Speed Cups Frozensgp30ebbrE9.b1
D960508.2SGP/EBBR/E7 - 3-month checksgp30ebbrE7.b1
D960508.4SGP/EBBR/E9 - 3-month checksgp30ebbrE9.b1
D961122.10SGP/EBBR/E9 - Air Temperature Thermocouples Incorrectsgp30ebbrE9.b1
D961122.20SGP/EBBR/E7 - EBBR 3-Month Checks - 10 EFssgp30ebbrE7.b1
D961122.22SGP/EBBR/E9 - EBBR 3 Month Checks - 10 EFssgp30ebbrE9.b1
D970330.4SGP/EBBR/E7- Wind Speed Cups Frozensgp30ebbrE7.b1
D970623.2SGP/EBBR/E9 - Temperature Portion of T/RH Probesgp30ebbrE9.b1
D971021.1SGP/EBBR/E7 - EBBR Biannual Checkssgp30ebbrE7.b1
D971021.3SGP/EBBR/E9 - EBBR Biannual Checkssgp30ebbrE9.b1
D971027.8SGP/EBBR/E9 - Wind Direction Sensor Malfunctionsgp30ebbrE9.b1
D980117.13SGP/EBBR/E9 - EBBR Frozen Wind Speedsgp30ebbrE9.b1
D980117.15SGP/EBBR/E7 - EBBR Frozen Wind Speedsgp30ebbrE7.b1
D980117.25SGP/EBBR/E9 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)sgp30ebbrE9.b1
D980117.31SGP/EBBR/E9 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affectedsgp30ebbrE9.b1
D980410.1SGP/EBBR/E7 - Right T/RH Probe Temperature Incorrectsgp30ebbrE7.b1
D980410.3SGP/EBBR/E7 - Wind Speed Sensor Frozensgp30ebbrE7.b1
D980410.5SGP/EBBR/E9 - Wind Speed Sensor Frozensgp30ebbrE9.b1
D980416.10SGP/EBBR/E9 - 3-Month Checksgp30ebbrE9.b1
D980416.8SGP/EBBR/E7 - 3-Month Checksgp30ebbrE7.b1
D980529.6SGP/EBBR/E7 - Six-Month Checkssgp30ebbrE7.b1
D980529.8SGP/EBBR/E9 - Six Month Checkssgp30ebbrE9.b1
D981113.2SGP/EBBR/E7 - Data Incorrect Because of Recompilesgp30ebbrE7.b1
D990127.12SGP/EBBR/E9 - Wind Direction Data Incorrectsgp30ebbrE9.b1
D990127.22SGP/EBBR/E7 - Wind Direction Data Incorrect (revised)sgp30ebbrE7.b1
D990127.8SGP/EBBR/E9 - EBBR E9 Net Radiometer Dome Broken, Flux Data Incorrectsgp30ebbrE9.b1
D990128.3SGP/EBBR/E7 - EBBR E7 Wind Speed Data Incorrectsgp30ebbrE7.b1
D990128.4SGP/EBBR/E7 - Wind Speed Data Incorrectsgp30ebbrE7.b1
D990128.6SGP/EBBR/E9 - Wind Speed Data Incorrectsgp30ebbrE9.b1
D990128.7SGP/EBBR/E9 - Wind Speed Data Incorrectsgp30ebbrE9.b1
D990622.5SGP/EBBR/E9 - Wind Speed Incorrectsgp30ebbrE9.b1
D990623.1SGP/EBBR/E9 - Right Aspirator Not Workingsgp30ebbrE9.b1


DQRID : D000214.2
Start DateStart TimeEnd DateEnd Time
12/23/1999090012/23/19991700
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Jumping Around
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs jumped around during the period, causing 
the soil moisture values and the quantities calculated from them to be 
incorrect.  The data values affected are shown below.


15 minute:  r_sm1, r_sm2, r_sm3, r_sm4, r_sm5
30 minute:  sm1, sm2, sm3, sm4, sm5, c_shf1, c_shf2, c_shf3, c_shf4, 
            c_shf5, g1, g2, g3, g4, g5, ave_shf, e, h
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000214.3
Start DateStart TimeEnd DateEnd Time
07/21/1999023010/30/19990330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Sensors #2 and #4 Negative
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture sensors #2 and #4 produced negative values for soil moisture
frequently during the period, causing the quantities calculated from them 
to be incorrect.  The version of the CR10X program at E7 does not have
max/min limits on the outputs. The data needs to be examined to determine 
times of incorrect soil moisture values.  The data values affected are 
shown below.


15 minute:  r_sm1, r_sm2, r_sm3, r_sm4, r_sm5
30 minute:  sm1, sm2, sm3, sm4, sm5, c_shf1, c_shf2, c_shf3, c_shf4, 
            c_shf5, g1, g2, g3, g4, g5, ave_shf, e, h
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000214.4
Start DateStart TimeEnd DateEnd Time
09/04/1999053009/10/19991330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Sensor #5 Negative
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture sensor #5 produced small negative values for soil moisture
infrequently during the period.  Because the vales were small negative, no
calculated data values are adversely affected. The data needs to be 
examined to determine times of incorrect soil moisture values.  
The data values affected are shown below.


15 minute:  r_sm5
30 minute:  sm5
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_5


Back To Table of Contents

DQRID : D000221.2
Start DateStart TimeEnd DateEnd Time
01/26/2000231502/01/20002050
Subject:
SGP/EBBR - EBBR E7 Left Aspirator Not Working
DataStreams:sgp30ebbrE7.b1
Description:
The left aspirator fan did not work during the period.

The following values were therefore incorrect:

5 minute:  tair_top, tair_bot, thum_top. thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_l, mv_hum_l, tair_l
30 minute: tair_top, tair_bot, thum_top. thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, e, h, bowen
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D000221.6
Start DateStart TimeEnd DateEnd Time
12/18/1999080012/18/19991930
Subject:
SGP/EBBR - EBBR E9 Anemometer Frozen, Wind Speed Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The anemometer cups were frozen stalled.

The following values were therefore incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D000224.10
Start DateStart TimeEnd DateEnd Time
01/10/2000020001/10/20000200
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.11
Start DateStart TimeEnd DateEnd Time
01/13/2000130001/13/20001300
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.12
Start DateStart TimeEnd DateEnd Time
01/14/2000133001/14/20001330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.13
Start DateStart TimeEnd DateEnd Time
02/01/2000133002/01/20001330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.14
Start DateStart TimeEnd DateEnd Time
02/02/2000133002/02/20001330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.15
Start DateStart TimeEnd DateEnd Time
02/04/2000140002/04/20001400
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.16
Start DateStart TimeEnd DateEnd Time
02/05/2000133002/05/20001330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.17
Start DateStart TimeEnd DateEnd Time
02/06/2000113002/06/20001130
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.5
Start DateStart TimeEnd DateEnd Time
12/24/1999010012/24/19990100
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.6
Start DateStart TimeEnd DateEnd Time
12/22/1999133012/22/19991330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
this day  causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.7
Start DateStart TimeEnd DateEnd Time
12/25/1999130012/25/19991300
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.8
Start DateStart TimeEnd DateEnd Time
01/01/2000023001/01/20000230
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000224.9
Start DateStart TimeEnd DateEnd Time
01/05/2000133001/05/20001330
Subject:
SGP/EBBR - EBBR E7 Soil Moisture Spike
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensor outputs are spiking up for a single half hour
for this day, causing the soil moisture values and
the quantities calculated from them to be incorrect.  The spiked half hours
are normally near sunrise.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000225.9
Start DateStart TimeEnd DateEnd Time
01/05/2000133001/05/20001330
Subject:
SGP/EBBR - EBBR E7 Soil Heat Flows Spiked
DataStreams:sgp30ebbrE7.b1
Description:
All soil heat flows were spiked during the period.  The affected data are:

15 minute: mv_hft1, mv_hft2, mv_hft3, mv_hft4, mv_hft5
30 minute: shf1, shf2, shf3, shf4, shf5, c_shf1, c_shf2, c_shf3, c_shf4,
           c_shf5, g1, g2, g3, g4, g5, ave_shf, h, e
Measurements:sgp30ebbrE7.b1:
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D000229.1
Start DateStart TimeEnd DateEnd Time
10/17/1999150010/30/19990330
Subject:
SGP/EBBR - EBBR E7 Soil Moistures #2 and #4 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture #2 and #4 were negative, often large negative, during very
dry soil conditions, causing several other quantities to also be incorrect. 

The affected data are:

15 minute: r_sm2, r_sm4
30 minute: sm2, sm4, c_shf2, c_shf4, cs2, cs4, ces2, ces4, g2, g4,
           ave_shf, h, e
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_4
  • soil_moisture_2
  • soil_heat_capacity_2
  • soil_moisture_4
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D000301.7
Start DateStart TimeEnd DateEnd Time
09/27/1999093009/28/19991700
Subject:
SGP/EBBR - EBBR E7 Net Radiation Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE7.b1:
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D000301.8
Start DateStart TimeEnd DateEnd Time
09/28/1999023009/30/19991500
Subject:
SGP/EBBR - EBBR E9 Net Radiation Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D010213.16
Start DateStart TimeEnd DateEnd Time
12/10/2000221512/15/20001715
Subject:
SGP/EBBR/E7 - EBBR E7 Wind Speed Iced
DataStreams:sgp30ebbrE7.b1
Description:
The anemometer was frozen stopped by freezing rain. Indicated data is incorrect.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D010316.148
Start DateStart TimeEnd DateEnd Time
03/14/2000205003/14/20002101
Subject:
SGP/EBBR/E7 - E7 EBBR Datalogger Replacement/Upgrade - Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The datalogger was replaced with one that had been upgraded
with a new operating system.  Data just after the 
replacement was incorrect.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.149
Start DateStart TimeEnd DateEnd Time
12/07/1999143012/07/19991431
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.150
Start DateStart TimeEnd DateEnd Time
12/09/1999133012/09/19991331
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.151
Start DateStart TimeEnd DateEnd Time
12/12/1999133012/12/19991331
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.152
Start DateStart TimeEnd DateEnd Time
12/12/1999190012/12/19991901
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.153
Start DateStart TimeEnd DateEnd Time
08/04/1999140008/04/19991431
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.154
Start DateStart TimeEnd DateEnd Time
08/04/1999153008/04/19991631
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.155
Start DateStart TimeEnd DateEnd Time
08/04/1999180008/04/19991801
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.156
Start DateStart TimeEnd DateEnd Time
08/04/1999220008/04/19992201
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.157
Start DateStart TimeEnd DateEnd Time
08/04/1999233008/05/19990031
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.158
Start DateStart TimeEnd DateEnd Time
08/05/1999043008/05/19990431
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.159
Start DateStart TimeEnd DateEnd Time
08/05/1999083008/05/19990831
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.160
Start DateStart TimeEnd DateEnd Time
08/07/1999073008/07/19990731
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic 
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.161
Start DateStart TimeEnd DateEnd Time
03/01/2000160003/01/20001631
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect while it was being replaced.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.162
Start DateStart TimeEnd DateEnd Time
05/09/2000183006/06/20001701
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #1 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #1 was incorrect.  A poor electronic
connection was suspected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 1(soil_temp_1)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.163
Start DateStart TimeEnd DateEnd Time
03/01/2000153003/01/20001701
Subject:
SGP/EBBR/E7 - E7 EBBR Right Aspirator Replacement
DataStreams:sgp30ebbrE7.b1
Description:
A number of the basic measurements and measurements calculated
from them were incorrect while the right AEM aspirator was replaced.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010316.164
Start DateStart TimeEnd DateEnd Time
08/04/1999124508/15/19992001
Subject:
SGP/EBBR/E7 - E7 EBBR Left Aspirator Fan Not Working
DataStreams:sgp30ebbrE7.b1
Description:
While the left aspirator fan was not working, the indicated
measurements were incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010316.165
Start DateStart TimeEnd DateEnd Time
11/07/2000193011/07/20002001
Subject:
SGP/EBBR/E7 - E7 EBBR Net Radiometer Dome Replacement
DataStreams:sgp30ebbrE7.b1
Description:
The net radiation, sensible heat flux, and latent heat flux
were incorrect while the net radiometer domes were being replaced.
Measurements:sgp30ebbrE7.b1:
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.166
Start DateStart TimeEnd DateEnd Time
09/26/2000210009/26/20002101
Subject:
SGP/EBBR/E7 - E7 EBBR All Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
All measurements were incorrect for an unknown reason.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.167
Start DateStart TimeEnd DateEnd Time
11/07/2000200011/07/20002001
Subject:
SGP/EBBR/E7 - E7 EBBR All Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
All measurements were incorrect for an unknown reason.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.168
Start DateStart TimeEnd DateEnd Time
03/01/2000133003/01/20001331
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikes
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensors spiked during the indicated period,
causing incorrect data.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.169
Start DateStart TimeEnd DateEnd Time
03/10/2000010003/10/20000101
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikes
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensors spiked during the indicated period,
causing incorrect data.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.170
Start DateStart TimeEnd DateEnd Time
02/01/2000133002/01/20001331
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikes
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensors spiked during the indicated period,
causing incorrect data.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.171
Start DateStart TimeEnd DateEnd Time
02/04/2000140002/04/20001401
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikes
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensors spiked during the indicated period,
causing incorrect data.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.172
Start DateStart TimeEnd DateEnd Time
02/05/2000133002/05/20001331
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikes
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensors spiked during the indicated period,
causing incorrect data.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.173
Start DateStart TimeEnd DateEnd Time
02/06/2000113002/06/20001131
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikes
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensors spiked during the indicated period,
causing incorrect data.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.174
Start DateStart TimeEnd DateEnd Time
02/09/2000130002/09/20001301
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture Spikes
DataStreams:sgp30ebbrE7.b1
Description:
All soil moisture sensors spiked during the indicated period,
causing incorrect data.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010316.175
Start DateStart TimeEnd DateEnd Time
08/13/2000193009/26/20002031
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Temperature #4 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Temperature probe #4 failed, resulting in incorrect data.
Measurements:sgp30ebbrE7.b1:
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D010319.31
Start DateStart TimeEnd DateEnd Time
12/12/2000030012/12/20001531
Subject:
SGP/EBBR/E7 - E7 EBBR AEM Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Icing caused the Automatic Exchange Mechanism to stop.  The
indicated measurements are therefore incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010319.32
Start DateStart TimeEnd DateEnd Time
12/13/2000064512/15/20001931
Subject:
SGP/EBBR/E7 - E7 EBBR AEM Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Icing caused the Automatic Exchange Mechanism to stop.  The
indicated measurements are therefore incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010319.33
Start DateStart TimeEnd DateEnd Time
12/17/2000000012/17/20001401
Subject:
SGP/EBBR/E7 - E7 EBBR AEM Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Icing caused the Automatic Exchange Mechanism to stop.  The
indicated measurements are therefore incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010319.34
Start DateStart TimeEnd DateEnd Time
12/22/2000020012/22/20001001
Subject:
SGP/EBBR/E7 - E7 EBBR AEM Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Icing caused the Automatic Exchange Mechanism to stop.  The
indicated measurements are therefore incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010319.35
Start DateStart TimeEnd DateEnd Time
12/25/2000233012/27/20001931
Subject:
SGP/EBBR/E7 - E7 EBBR AEM Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Icing caused the Automatic Exchange Mechanism to stop.  The
indicated measurements are therefore incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010319.36
Start DateStart TimeEnd DateEnd Time
12/27/2000220012/28/20001831
Subject:
SGP/EBBR/E7 - E7 EBBR AEM Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Icing caused the Automatic Exchange Mechanism to stop.  The
indicated measurements are therefore incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010319.37
Start DateStart TimeEnd DateEnd Time
12/30/2000080012/30/20001031
Subject:
SGP/EBBR/E7 - E7 EBBR AEM Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Icing caused the Automatic Exchange Mechanism to stop.  The
indicated measurements are therefore incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D010319.40
Start DateStart TimeEnd DateEnd Time
04/29/2000083004/29/20001431
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Moisture probe #2 was not capable of measuring very low soil moistures
in the dry conditions present.  The small positive, negative, and offscale measurements 
are incorrect.  Several other measurements calculated from soil moisture are incorrect 
also, as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D010319.41
Start DateStart TimeEnd DateEnd Time
04/30/2000013005/01/20000001
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Moisture probe #2 was not capable of measuring very low soil moistures
in the dry conditions present.  The small positive, negative, and offscale measurements 
are incorrect.  Several other measurements calculated from soil moisture are incorrect 
also, as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D010319.42
Start DateStart TimeEnd DateEnd Time
07/20/2000093007/20/20001101
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Moisture probe #2 was not capable of measuring very low soil moistures
in the dry conditions present.  The small positive, negative, and offscale measurements 
are incorrect.  Several other measurements calculated from soil moisture are incorrect 
also, as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D010319.43
Start DateStart TimeEnd DateEnd Time
08/10/2000073008/10/20001601
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Moisture probe #2 was not capable of measuring very low soil moistures
in the dry conditions present.  The small positive, negative, and offscale measurements 
are incorrect.  Several other measurements calculated from soil moisture are incorrect 
also, as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D010319.44
Start DateStart TimeEnd DateEnd Time
08/11/2000023009/23/20000501
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Moisture probe #2 was not capable of measuring very low soil moistures
in the dry conditions present.  The small positive, negative, and offscale measurements 
are incorrect.  Several other measurements calculated from soil moisture are incorrect 
also, as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D010319.45
Start DateStart TimeEnd DateEnd Time
12/12/2000053012/13/20002301
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture # 2 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Moisture probe #2 was not capable of measuring very low soil moistures
in the dry conditions present.  The small positive, negative, and offscale measurements 
are incorrect.  Several other measurements calculated from soil moisture are incorrect 
also, as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • corr_soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D010319.46
Start DateStart TimeEnd DateEnd Time
05/01/2000153005/01/20001531
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moistures 2, 4, and 5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Moisture Probes 2, 4, and 5 were not capable of measuring very low soil moistures in 
the dry conditions present.  The offscale measurements are incorrect.  Several other 
measurements calculated from soil moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • energy_storage_change_2
  • soil_moisture_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • energy_storage_change_4
  • soil_moisture_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D010319.50
Start DateStart TimeEnd DateEnd Time
07/13/2000040007/20/20001201
Subject:
SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #4 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • soil_moisture_4
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D010319.51
Start DateStart TimeEnd DateEnd Time
04/30/2000233504/30/20002356
Subject:
SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #4 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • soil_moisture_4
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D010319.52
Start DateStart TimeEnd DateEnd Time
04/30/2000180004/30/20001826
Subject:
SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #4 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • soil_moisture_4
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D010319.53
Start DateStart TimeEnd DateEnd Time
08/06/2000003009/23/20000501
Subject:
SGP/EBBR E7 - E7 EBBR Soil Moisture #4 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #4 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • soil_moisture_4
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D010319.54
Start DateStart TimeEnd DateEnd Time
08/16/2000110008/16/20001431
Subject:
SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #5 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are also incorrect as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • soil_heat_capacity_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010319.55
Start DateStart TimeEnd DateEnd Time
08/17/2000053008/17/20001601
Subject:
SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #5 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are also incorrect as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • soil_heat_capacity_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010319.56
Start DateStart TimeEnd DateEnd Time
08/18/2000023008/18/20002001
Subject:
SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #5 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are also incorrect as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • soil_heat_capacity_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010319.57
Start DateStart TimeEnd DateEnd Time
08/18/2000220009/23/20000931
Subject:
SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #5 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are also incorrect as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • soil_heat_capacity_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010319.58
Start DateStart TimeEnd DateEnd Time
10/08/2000073010/08/20001531
Subject:
SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #5 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are also incorrect as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • soil_heat_capacity_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010319.59
Start DateStart TimeEnd DateEnd Time
10/09/2000070010/09/20001531
Subject:
SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #5 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are also incorrect as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • soil_heat_capacity_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010319.60
Start DateStart TimeEnd DateEnd Time
10/10/2000090010/10/20001501
Subject:
SGP/EBBR/E7 - E7 EBBR soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #5 was not capable of measuring very low soil moistures in the dry 
conditions present.  The small positive, negative, and offscale measurements are incorrect.  
Several other measurements calculated from soil moisture are also incorrect as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_5
  • soil_heat_capacity_5
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D010319.61
Start DateStart TimeEnd DateEnd Time
08/28/2000103008/28/20001501
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.62
Start DateStart TimeEnd DateEnd Time
08/29/2000083008/29/20001531
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.63
Start DateStart TimeEnd DateEnd Time
08/30/2000053008/30/20001631
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.64
Start DateStart TimeEnd DateEnd Time
08/31/2000050008/31/20001701
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.65
Start DateStart TimeEnd DateEnd Time
09/01/2000033009/01/20001731
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.66
Start DateStart TimeEnd DateEnd Time
09/02/2000033009/02/20001731
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.67
Start DateStart TimeEnd DateEnd Time
09/03/2000033009/03/20001801
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.68
Start DateStart TimeEnd DateEnd Time
09/04/2000013009/04/20001901
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.69
Start DateStart TimeEnd DateEnd Time
09/05/2000043009/05/20001531
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.70
Start DateStart TimeEnd DateEnd Time
09/06/2000103009/06/20001501
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.71
Start DateStart TimeEnd DateEnd Time
09/10/2000110009/10/20001531
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.72
Start DateStart TimeEnd DateEnd Time
09/11/2000090009/11/20001601
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.73
Start DateStart TimeEnd DateEnd Time
09/12/2000063009/12/20001831
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.74
Start DateStart TimeEnd DateEnd Time
09/13/2000020009/13/20001701
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.75
Start DateStart TimeEnd DateEnd Time
09/14/2000113009/14/20001401
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.76
Start DateStart TimeEnd DateEnd Time
09/15/2000080009/15/20001631
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.77
Start DateStart TimeEnd DateEnd Time
09/16/2000043009/16/20001826
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.78
Start DateStart TimeEnd DateEnd Time
09/17/2000023009/17/20001831
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.79
Start DateStart TimeEnd DateEnd Time
09/18/2000010009/18/20002031
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010319.80
Start DateStart TimeEnd DateEnd Time
09/18/2000223009/23/20000431
Subject:
SGP/EBBR/E7 - E7 EBBR Soil Moisture #3 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture probe #3 was not capable of measuring very low soil moistures in the dry 
conditions that were present.  The small positive, negative, and
offscale measurements are incorrect.  Several other measurements calculated from soil 
moisture are incorrect also as a result.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D010402.1
Start DateStart TimeEnd DateEnd Time
12/11/2000000012/11/20001331
Subject:
SGP/EBBR/E9 - E9 EBBR Wind Direction Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind direction vane was frozen in one direction by icing during the indicated period.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D010402.2
Start DateStart TimeEnd DateEnd Time
12/10/2000201512/15/20001631
Subject:
SGP/EBBR/E9 - E9 EBBR Wind Speed Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed sensor cups were frozen in place by icing.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D010402.3
Start DateStart TimeEnd DateEnd Time
12/18/2000153002/13/20011546
Subject:
SGP/EBBR/E9 - E9 EBBR Soil Heat Flow 1 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Heat flow sensor #1 produced measurements that were large negative during the 
indicated period.  This was the result of sensor failure.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1


Back To Table of Contents

DQRID : D010402.5
Start DateStart TimeEnd DateEnd Time
03/13/2000160003/13/20001601
Subject:
SGP/EBBR/E9 - E9 EBBR Soil Heat Capacities Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Heat Capacities were out-of-range during this period, as reported by
the datalogger. The cause of this is unknown.

Actual values used in the computations of fluxes were okay, as the fluxes were not 
affected.
Measurements:sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5


Back To Table of Contents

DQRID : D011127.23
Start DateStart TimeEnd DateEnd Time
11/25/2001143511/25/20011601
05/08/2001180005/08/20011901
Subject:
SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE7.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • rh_top_fraction
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D011127.25
Start DateStart TimeEnd DateEnd Time
05/22/2001150005/22/20011536
04/12/2001180004/12/20011846
10/23/2001151010/23/20011701
Subject:
SGP EBBR E9 - E9 EBBR Data Incorect During 6 Month Checks
DataStreams:sgp30ebbrE9.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE9.b1:
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Atmospheric pressure(atmos_pressure)
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Net radiation(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • temp_trh_top
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • temp_air_bottom
  • soil_heat_flow_3
  • soil_moisture_1
  • Wind direction vector mean(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D011129.2
Start DateStart TimeEnd DateEnd Time
02/28/2001133002/28/20011331
Subject:
SGP EBBR E7 - E7 EBBR Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture measurements were spiked by an unknown cause.
This caused the indicated measurements and calculated
quantities to be incorrect.
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D011129.3
Start DateStart TimeEnd DateEnd Time
03/09/2001123003/09/20011231
Subject:
SGP EBBR E7 - E7 EBBR Soil Moisture #3 and Other Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture #3 spiked and caused other measurements and calculated quantities
to also be incorrect.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D011129.4
Start DateStart TimeEnd DateEnd Time
03/27/2001174503/27/20011936
Subject:
SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Data
DataStreams:sgp30ebbrE7.b1
Description:
The AEM stuck in one position, cuasing incorrect measurements
and calculated quantities.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D011129.5
Start DateStart TimeEnd DateEnd Time
03/29/2001150003/29/20011501
Subject:
SGP EBBR E7 - E7 EBBR Soil Moisture #2 Spiked, Incorrect Data Resulted
DataStreams:sgp30ebbrE7.b1
Description:
Soil moisture #2 spiked and caused other measurements and calculated quantities to
also be incorrect.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_2
  • soil_moisture_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D011129.6
Start DateStart TimeEnd DateEnd Time
04/10/2001194504/10/20012031
Subject:
SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Data
DataStreams:sgp30ebbrE7.b1
Description:
The AEM stuck in one position, causing the indicated measurements and calculated
quantities to be incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D011129.7
Start DateStart TimeEnd DateEnd Time
05/07/2001190005/07/20011901
Subject:
SGP EBBR E7 - E7 EBBR All Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The data was incorrect immediately after the re-calibrated system was 
installed and put into service.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D011129.8
Start DateStart TimeEnd DateEnd Time
05/07/2001193005/07/20011931
Subject:
SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibration
DataStreams:sgp30ebbrE7.b1
Description:
Soil temperature measurements and the half hour average were incorrect the half hour after 
starting the recalibrated system, causing other measurements and calculated quantities 
to be incorrect.
Measurements:sgp30ebbrE7.b1:
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_1
  • Soil temperature mean 1(soil_temp_1)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D011129.9
Start DateStart TimeEnd DateEnd Time
08/28/2001190008/28/20011901
Subject:
SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Period
DataStreams:sgp30ebbrE7.b1
Description:
Soil temperature measurements and the half hour average were incorrect the half hour after 
a missing data period, causing other measurements and calculated quantities to be 
incorrect.
Measurements:sgp30ebbrE7.b1:
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_1
  • Soil temperature mean 1(soil_temp_1)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D011221.2
Start DateStart TimeEnd DateEnd Time
02/23/2001054502/25/20011201
02/22/2001203102/22/20012301
03/20/2001014503/29/20011601
02/28/2001201503/11/20010831
01/01/2001000001/03/20011901
02/09/2001061502/11/20011701
01/20/2001091502/09/20010001
Subject:
SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
A worn AEM belt caused the AEM to hang frequently.
Gradient measurements, sensible heat flux, latent heat flux,
and Bowen ratio are incorrect during the indicated periods.

The AEM hung on 2/9/01 because of icing from an ice storm.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D011221.3
Start DateStart TimeEnd DateEnd Time
04/29/2001100005/08/20011501
04/24/2001124504/25/20010131
04/23/2001191504/24/20010031
04/10/2001154504/10/20011831
04/03/2001194504/03/20012331
04/29/2001074504/29/20010801
04/25/2001121504/26/20010501
04/08/2001131504/09/20010931
04/12/2001174504/12/20011901
04/29/2001000004/29/20010201
Subject:
SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The AEM belt was worn and the AEM hung frequently.
Gradients, sensible heat flux, latent heat flux,
and Bowen ratio were incorrect during the indicated period.

The AEM was replaced during the recalibration changeout
on 5/11/01.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D011221.4
Start DateStart TimeEnd DateEnd Time
01/28/2001053001/29/20012031
02/14/2001173502/16/20011831
02/09/2001043002/11/20011531
Subject:
SGP EBBR E9 - E9 EBBR Wind Speed Frozen Stopped
DataStreams:sgp30ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stop.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D011221.5
Start DateStart TimeEnd DateEnd Time
01/28/2001080001/29/20011701
02/09/2001043002/10/20011801
02/14/2001173502/16/20011831
Subject:
SGP EBBR E9 - E9 EBBR Wind Direction Frozen In One Direction
DataStreams:sgp30ebbrE9.b1
Description:
An ice storm froze the wind direction sensor in one postion.
Th indicated measurements are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D011221.6
Start DateStart TimeEnd DateEnd Time
05/15/2001231512/14/20012356
Subject:
SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil moisture probe #5 in the recalibrated unit installed
on 5/11/01 has not been working all of the time.  At times
the measurement has been very large and incorrect.  The
indicated measurements are incorrect at those times.  The
data must be inspected to determine the times that 
have incorrect data.  The sensible and latent heat fluxes can
be recalculated by using soil sets 1, 2, 3, and 4 only in a 
recalculation of the energy budget.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5


Back To Table of Contents

DQRID : D011221.8
Start DateStart TimeEnd DateEnd Time
07/19/2001150007/19/20011631
Subject:
SGP EBBR E9 - E9 EBBR Gradients Incorrect During Sensor Replacement
DataStreams:sgp30ebbrE9.b1
Description:
During the replacement of the right air temperature
probe, all gradient measurements were incorrect.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D020110.2
Start DateStart TimeEnd DateEnd Time
07/18/2001123007/18/20011431
07/16/2001053007/16/20011946
07/15/2001083007/15/20012216
07/14/2001023007/14/20012016
07/19/2001071507/19/20011616
07/17/2001130007/17/20011316
Subject:
SGP EBBR E9 - E9 EBBR Right Air Temperature Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The right air temperature probe measurements were
incorrect during these periods.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D020628.11
Start DateStart TimeEnd DateEnd Time
11/15/1994160511/15/19941800
Subject:
SGP/EBBR/E7 - T/RH Check
DataStreams:sgp30ebbrE7.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields
5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

5 minute:  1605, 1610, 1615, 1620, 1625, 1630, 1635, 1640, 1645,
           1650, 1655, 1700, 1705, 1710, 1715, 1720, 1725, 1730,
           1735, 1740, 1745, 1750
15 minute: 1615, 1630, 1645, 1700, 1715, 1730, 1745, 1800
30 minute: 1630, 1700, 1730, 1800

(EDITOR'S NOTE: The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D020628.14
Start DateStart TimeEnd DateEnd Time
11/14/1994182011/14/19942000
Subject:
SGP/EBBR/E9 - T/RH Check
DataStreams:sgp30ebbrE9.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h


5 minute:  1820, 1825, 1830, 1835, 1840, 1845, 1850, 1855, 1900,
           1905, 1910, 1915, 1920, 1925, 1930, 1935, 1940, 1945
15 minute: 1830, 1845, 1900, 1915, 1930, 1945
30 minute: 1830, 1900, 1930, 2000


(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D020628.8
Start DateStart TimeEnd DateEnd Time
10/04/1995150010/04/19951800
Subject:
SGP/EBBR/E7 - 3-month Check
DataStreams:sgp30ebbrE7.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D020716.1
Start DateStart TimeEnd DateEnd Time
11/15/1995210011/25/19950000
Subject:
SGP/EBBR/E9 - Annual calibration changeout
DataStreams:sgp30ebbrE9.b1
Description:
On November 15, 1995 the changeout for annual calibration occurred at E9,
Ashton, KS.  The soil moisture sensors were shipped wet from the vendor 
and did not stabilize until 25 November 1995.  The following data should 
be considered incorrect until 25 November 1995:

15 minute:  rr_sm1, rr_sm2, rr_sm3, rr_sm4, rr_sm5

30 minute:  h, e, ave_shf, shf1, shf2, shf3, shf4, shf5, sm1, sm2, sm3,
            sm4, sm5, cs1, cs2, cs3, cs4, cs5, ces1, ces2, ces3, ces4,
            g1, g2, g3, g4, g5.
Measurements:sgp30ebbrE9.b1:
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1
  • energy_storage_change_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • Sensible heat flux(sensible_heat_flux)
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • soil_moisture_1
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4


Back To Table of Contents

DQRID : D020716.10
Start DateStart TimeEnd DateEnd Time
05/09/2002160005/09/20021631
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp30ebbrE9.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D020716.2
Start DateStart TimeEnd DateEnd Time
11/15/1995210011/16/19951700
Subject:
SGP/EBBR/E9 - Annual calibration changeout
DataStreams:sgp30ebbrE9.b1
Description:
On November 15, 1995 the changeout for annual calibration occurred at E9,
Ashton, KS.  After installation of the new SEBS unit, RH output was zero.  
The next day site operations personnel found that the RH probe cable 
connections were loose.  RH returned to normal after the connections were 
tightened at 1700 GMT on 16 November 1995.  During the period of time that 
the connections were not made, the following data values are incorrect: 

5 minute:  hum_top, hum_bot, vp_top, vp_bot

15 minute: mv_hum_r, mv_hum_l

30 minute: hum_top, hum_bot, vp_top, vp_bot.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • rh_top_fraction


Back To Table of Contents

DQRID : D020716.26
Start DateStart TimeEnd DateEnd Time
03/12/2002210003/12/20022101
Subject:
SGP/EBBR/E7 - Measurements Zero
DataStreams:sgp30ebbrE7.b1
Description:
The indicated measurements were zero after interruption of the CR10 program.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D020716.27
Start DateStart TimeEnd DateEnd Time
04/14/2002220004/23/20021531
05/20/2002120006/06/20021501
Subject:
SGP/EBBR/E7 - AEM Hung
DataStreams:sgp30ebbrE7.b1
Description:
The indicated measurements were incorrect because the automatic exchange mechanism hung in 
one position.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D020716.28
Start DateStart TimeEnd DateEnd Time
05/20/2002120005/21/20021601
Subject:
SGP/EBBR/E7 - Wind Speed Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed and resultant wind speed are incorrect for the indicated times because a 
cup had broken off of the cup anemometer.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D020716.8
Start DateStart TimeEnd DateEnd Time
05/07/2002164505/07/20021716
Subject:
SGP/EBBR/E7 - 6 Month Checks
DataStreams:sgp30ebbrE7.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D020717.2
Start DateStart TimeEnd DateEnd Time
12/15/2001000006/30/20022356
Subject:
SGP/EBBR/E9 - Reprocess: Soil Temperature #5 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil temperature # 5 was incorrect most of the time, leading to incorrect surface heat 
flow, latent heat flux and sensible heat flux.  The heat fluxes can be recalculated by using 
soil sets 1-4 as follows:

ave_shf = (g1 + g2 + g3 + g4)/4
e = -(q + ave_shf)/(1 + bowen)
h = -(q + e + ave_shf)
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5


Back To Table of Contents

DQRID : D020717.3
Start DateStart TimeEnd DateEnd Time
06/04/2002150006/04/20021501
03/28/2002160003/28/20021601
Subject:
SGP/EBBR/E9 - Measurements All Zeros
DataStreams:sgp30ebbrE9.b1
Description:
The measurements were all zeros at the indicated times.  This occurs after a CR10 program 
restart, which sometimes happens after some servicing of the EBBR is performed.
Measurements:sgp30ebbrE9.b1:
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Atmospheric pressure(atmos_pressure)
  • home_signal_30
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Net radiation(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • temp_trh_top
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • soil_heat_flow_3
  • temp_air_bottom
  • soil_moisture_1
  • Wind direction vector mean(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D020717.4
Start DateStart TimeEnd DateEnd Time
03/28/2002161503/28/20021801
Subject:
SGP/EBBR/E9 - Humidity Probe Measurements Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The temperature and humidity measurements from both T/RH probes were incorrect during 
changeout of the right probe.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D020717.5
Start DateStart TimeEnd DateEnd Time
01/30/2002101507/16/20021630
Subject:
SGP/EBBR/E9 - Right Humidity Suspect
DataStreams:sgp30ebbrE9.b1
Description:
The Right Humidity measurement was normally incorrect, although it is often difficult to 
determine it by looking at the measurement.  The measurements float around, sometimes 
being too large and sometimes being too small, through most of the day, particularly for the 
hour before sunset through the hour after sunrise.  Great care and comparison with 
surrounding EBBR sites would be needed to be able to use any of the latent and sensible heat 
flux measurements from E9 for this period. 

Another DQPR has been issued to fix this problem, which has eluded repair efforts so far.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D021113.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE9.b1, sgp30ebbrE7.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D021113.2
Start DateStart TimeEnd DateEnd Time
10/01/1995000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30baebbrE7.c1, sgp30baebbrE9.c1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30baebbrE7.c1:
  • cs5
  • cs4
  • cs3
  • cs2
  • cs1

sgp30baebbrE9.c1:
  • cs2
  • cs1
  • cs4
  • cs3
  • cs5


Back To Table of Contents

DQRID : D021113.4
Start DateStart TimeEnd DateEnd Time
12/01/1993120006/18/20031159
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE7.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.
   
This does not affect the data quality.

(NOTE: The actual begin date of some of these data streams
 is as early as 7/4/93.  This DQR applies to all 30m EBBR
 data.)
Measurements:sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D030110.30
Start DateStart TimeEnd DateEnd Time
11/19/2002200011/19/20022030
Subject:
SGP/EBBR/E7 - Data Incorrect during 6 month checks
DataStreams:sgp30ebbrE7.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D030110.32
Start DateStart TimeEnd DateEnd Time
11/19/2002163511/19/20021735
Subject:
SGP/EBBR/E9 - Data Incorrect during 6 month checks
DataStreams:sgp30ebbrE9.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D030113.1
Start DateStart TimeEnd DateEnd Time
07/11/2002210007/18/20021700
Subject:
SGP/EBBR/E7 - Wind speed incorrect
DataStreams:sgp30ebbrE7.b1
Description:
A wind speed sensor electronics problem limited the
measurement to the sensor offset.  This data was incorrect.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D030113.3
Start DateStart TimeEnd DateEnd Time
07/30/2002190007/30/20021901
Subject:
SGP/EBBR/E7 - CES data incorrect
DataStreams:sgp30ebbrE7.b1
Description:
After a missing half hour, the soil temperature at the beginning of the half hour cannot 
be used to determine the soil energy storage term.  Therefore the
change of energy calculation blows up.  The indicated measurements are therefore 
incorrect.
Measurements:sgp30ebbrE7.b1:
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D030113.4
Start DateStart TimeEnd DateEnd Time
11/05/2002210011/05/20022129
Subject:
SGP/EBBR/E7 - Reprocess: Soil Heat Flow #2 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Heat Flow #2 measurements were incorrect while it was being replaced.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_2
  • soil_heat_flow_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D030113.5
Start DateStart TimeEnd DateEnd Time
11/05/2002213011/05/20022159
Subject:
SGP/EBBR/E7 - Change In Energy Storage Calculations Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Because soil temperature measurements were not available from the beginning of the half 
hour, the change in soil energy storage could not be calculated and thus is incorrect.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • surface_soil_heat_flux_1
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D030113.6
Start DateStart TimeEnd DateEnd Time
09/22/2002163012/03/20021830
Subject:
SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #5 too low
DataStreams:sgp30ebbrE7.b1
Description:
Soil Heat Flow #5 was sometimes 2X the other soil heat flow measurements when
heat flows were negative.  This does not usually greatly affect h and e, therefore the 
data color has been set to yellow.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030113.7
Start DateStart TimeEnd DateEnd Time
08/24/2002023008/27/20021800
07/10/2002080007/16/20021900
07/22/2002163007/30/20021630
Subject:
SGP/EBBR/E7 - AEM Problems
DataStreams:sgp30ebbrE7.b1
Description:
The AEM (Automatic Exchange Mechanism) hung in a non-home position for
a few lengthy periods, during which the indicated measurements are incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D030113.8
Start DateStart TimeEnd DateEnd Time
10/01/2002170010/08/20021645
Subject:
SGP/EBBR/E7 - T/RH Ventilator Fans Stopped
DataStreams:sgp30ebbrE7.b1
Description:
The temperature and relative humidity gradients are suspect because the 
ventilator fans were not operating during this time period. The data needs
to be carefully inspected to determine when measurements, if any, are correct.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D030114.2
Start DateStart TimeEnd DateEnd Time
07/30/2002180007/30/20021829
Subject:
SGP/EBBR/E7 - Data Reported as Zero following Logger Replacement
DataStreams:sgp30ebbrE7.b1
Description:
The data was reported as zero after a data logger replacement.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030114.5
Start DateStart TimeEnd DateEnd Time
07/01/2002000007/16/20021530
Subject:
SGP/EBBR/E9 - Reprocess: Soil Temperature #5 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Temperature #5 was intermittently incorrect.
The cause is unknown. The indicated measurements 
that are calculated using soil temperature are 
also incorrect.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5


Back To Table of Contents

DQRID : D030114.6
Start DateStart TimeEnd DateEnd Time
07/16/2002150007/16/20021529
Subject:
SGP/EBBR/E9 - Reprocess: Soil Heat Flow #4 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Heat Flow #4 was incorrect during these periods as a 
consequence of the repair of Soil Temperature #5.  
See below for a work-around.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_4


Back To Table of Contents

DQRID : D030114.8
Start DateStart TimeEnd DateEnd Time
09/24/2002160009/24/20021630
Subject:
SGP/EBBR/E9 - Net Rad data bad during dome replacement
DataStreams:sgp30ebbrE9.b1
Description:
The net radiation measurement was incorrect during replacement
of the top dome. Measurements calculated using net radiation are also incorrect.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D030114.9
Start DateStart TimeEnd DateEnd Time
11/17/2002070011/19/20021730
11/16/2002133011/16/20021430
Subject:
SGP/EBBR/E9 - AEM Malfunction
DataStreams:sgp30ebbrE9.b1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
inbetween a home position, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D030620.1
Start DateStart TimeEnd DateEnd Time
06/11/2003173007/15/20032000
Subject:
SGP/EBBR/E7 - Soil Heat Flow #5 Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Heat Flow Plate #5 data was intermittently incorrect at first 
(values too small negative), then was almost constantly so during the 
last half of the period.

Comparison of the individual soil heat flows will quickly show the times
that soil heat flow #5 was incorrect.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030712.1
Start DateStart TimeEnd DateEnd Time
02/23/2003200003/13/20031745
Subject:
SGP/EBBR/E9  - AEM Hung Inbetween Home Positions
DataStreams:sgp30ebbrE9.b1
Description:
The AEM was hung inbetween home positions, causing many measurements to be incorrect.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D030712.13
Start DateStart TimeEnd DateEnd Time
04/22/2003165004/22/20031720
Subject:
SGP/EBBR/E7  - 6 Month Checks
DataStreams:sgp30ebbrE7.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D030712.15
Start DateStart TimeEnd DateEnd Time
04/24/2003180004/24/20031830
Subject:
SGP/EBBR/E9  - 6 Month Checks
DataStreams:sgp30ebbrE9.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D030712.2
Start DateStart TimeEnd DateEnd Time
05/09/2003180005/09/20031800
Subject:
SGP/EBBR/E9  - Soil Heat Flow #1 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Heat Flow #1 was incorrect.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_1


Back To Table of Contents

DQRID : D030712.3
Start DateStart TimeEnd DateEnd Time
05/14/2003110005/30/20031700
Subject:
SGP/EBBR/E9 -   Battery Voltage Low
DataStreams:sgp30ebbrE9.b1
Description:
Many of the measurements are incorrect much of the time during this period,
when the battery voltage was 10.9 volts or less.
Measurements:sgp30ebbrE9.b1:
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Atmospheric pressure(atmos_pressure)
  • home_signal_30
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Net radiation(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • temp_trh_top
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • soil_heat_flow_3
  • temp_air_bottom
  • soil_moisture_1
  • Wind direction vector mean(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D030712.9
Start DateStart TimeEnd DateEnd Time
02/24/2003090003/11/20031800
Subject:
SGP/EBBR/E7  - AEM Hung Inbetween Home Position
DataStreams:sgp30ebbrE7.b1
Description:
The AEM was hung inbetween home positions, causing many measurements to be incorrect.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D030729.2
Start DateStart TimeEnd DateEnd Time
07/24/2003123008/12/20031615
Subject:
SGP/EBBR/E9 - AEM Hung in home 30 position.
DataStreams:sgp30ebbrE9.b1
Description:
The AEM was hung in the home 30 position.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D030729.3
Start DateStart TimeEnd DateEnd Time
07/27/2003133010/07/20032000
Subject:
SGP/EBBR/E7  - AEM Malfunction, Some Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
After a while, the teflon slides on the AEMs warp from
heat and use.  This tends to make the AEM drag, jam, and get hung.
This happened at E7 EBBR.

Replacement of the AEM resolved the problem.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D030917.2
Start DateStart TimeEnd DateEnd Time
10/13/2003000011/18/20032000
Subject:
SGP/EBBR/E7 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil Heat Flow #5 went offscale at times.

Latent and Sensible Heat Fluxes were incorrect when this occurred.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030919.1
Start DateStart TimeEnd DateEnd Time
08/26/2003180008/26/20031800
Subject:
SGP/EBBR/E7 - Data all zero
DataStreams:sgp30ebbrE7.b1
Description:
Data values were all zero after restarting the CR10 datalogger.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030919.2
Start DateStart TimeEnd DateEnd Time
08/26/2003183008/26/20031830
Subject:
SGP/EBBR/E7 - Energy Storage Incorrect, Fluxes Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The half hour after restart of the CR10 datalogger, the soil temperatures for the 
beginning of the period are missing.  Therefore the soil energy storage and surface flux values 
are also incorrect.
Measurements:sgp30ebbrE7.b1:
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D030919.3
Start DateStart TimeEnd DateEnd Time
08/29/2003023009/05/20031730
Subject:
SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE7.b1:
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D030919.7
Start DateStart TimeEnd DateEnd Time
08/02/2003060008/04/20031800
Subject:
SGP/EBBR/E9  - Water in Net Radiometer; Surface Fluxes are Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D031031.1
Start DateStart TimeEnd DateEnd Time
10/20/2003133010/20/20031630
10/22/2003000010/22/20031830
10/21/2003163010/21/20031830
10/19/2003173010/19/20031930
10/23/2003000010/23/20031630
Subject:
SGP/EBBR/E7  - Reference Temperature Failure
DataStreams:sgp30ebbrE7.b1
Description:
The reference T sensor was not working, affecting 
other temperature sensors.  Sensible and latent heat fluxes
were incorrect when this occurred.
Measurements:sgp30ebbrE7.b1:
  • temp_air_top
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D031031.3
Start DateStart TimeEnd DateEnd Time
09/23/2003160009/23/20031600
Subject:
SGP/EBBR/E9  - Measurements All Zero
DataStreams:sgp30ebbrE9.b1
Description:
Data values were all zero after restarting the CR10 datalogger.
Measurements:sgp30ebbrE9.b1:
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Atmospheric pressure(atmos_pressure)
  • home_signal_30
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Net radiation(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • temp_trh_top
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • soil_heat_flow_3
  • temp_air_bottom
  • soil_moisture_1
  • Wind direction vector mean(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D031204.6
Start DateStart TimeEnd DateEnd Time
11/04/2003220011/04/20032230
Subject:
SGP/EBBR/E7 - 6 Month Checks
DataStreams:sgp30ebbrE7.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D031204.8
Start DateStart TimeEnd DateEnd Time
11/04/2003173011/04/20031800
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp30ebbrE9.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D031211.6
Start DateStart TimeEnd DateEnd Time
03/07/2003150010/12/20032355
Subject:
SGP/EBBR/E7 - Pressure Sensor Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The E7 pressure sensor suffered
from spikes in pressure, which were related to 
increases in voltage during the day as the 
solar panels charged the battery.  These spikes
were not of a magnitude that would affect the 
30 minute surface fluxes.

Replacement of the pressure sensor solved the problem.
Measurements:sgp30ebbrE7.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031222.13
Start DateStart TimeEnd DateEnd Time
12/14/2003010012/14/20031930
Subject:
SGP/EBBR/E9  - Net Radiometer Iced Over During Storm
DataStreams:sgp30ebbrE9.b1
Description:
The net radiometer was covered with ice from a storm.  Net radiation values are incorrect, 
and are sometimes even negative during the daytime.  Sensible and latent heat fluxes are 
therefore incorrect.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D031222.14
Start DateStart TimeEnd DateEnd Time
12/09/2003202012/10/20030645
Subject:
SGP/EBBR/E9 - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D031222.9
Start DateStart TimeEnd DateEnd Time
12/09/2003222012/10/20031200
Subject:
SGP/EBBR/E7 - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed sensor was frozen stopped by ice.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040206.3
Start DateStart TimeEnd DateEnd Time
10/13/2003000001/28/20042030
Subject:
SGP/EBBR/E7 - Pressure Sensor Data Incorret
DataStreams:sgp30ebbrE7.b1
Description:
The E7 pressure sensor suffered
from spikes in pressure, which were related to 
increases in voltage during the day as the 
solar panels charged the battery.  These spikes
were not of a magnitude that would affect the 
30 minute surface fluxes.

Replacement of the pressure sensor solved the problem.
Measurements:sgp30ebbrE7.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D040304.3
Start DateStart TimeEnd DateEnd Time
02/05/2004233002/06/20041210
02/02/2004084002/03/20041650
01/26/2004075501/28/20041550
Subject:
SGP/EBBR/E7  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040304.4
Start DateStart TimeEnd DateEnd Time
02/19/2004212002/20/20040305
Subject:
SGP/EBBR/E7 - Tref Problem Causes All Temps. to be Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The Tref sensor went crazy for this brief period, making all temperature
measurements incorrect.
Measurements:sgp30ebbrE7.b1:
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • temp_air_top
  • temp_reference
  • Soil temperature mean 3(soil_temp_3)
  • temp_trh_bottom
  • temp_trh_top
  • temp_air_bottom
  • Soil temperature mean 1(soil_temp_1)


Back To Table of Contents

DQRID : D040304.8
Start DateStart TimeEnd DateEnd Time
01/28/2004033001/28/20040355
01/27/2004193501/28/20040140
01/31/2004180002/12/20041640
01/27/2004174501/27/20041800
Subject:
SGP/EBBR/E9  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition. The bearings
in the sensor appear to be worn, contributing to the problem.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040304.9
Start DateStart TimeEnd DateEnd Time
02/09/2004094502/09/20041430
02/02/2004000002/03/20041740
02/05/2004112002/05/20041405
Subject:
SGP/EBBR/E9  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE9.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D040723.2
Start DateStart TimeEnd DateEnd Time
06/28/2004120006/29/20041530
Subject:
SGP/EBBR/E9 - net radiometer top dome broken, water in bottom dome
DataStreams:sgp30ebbrE9.b1
Description:
The Net radiometer top dome was broken.  Site Ops did not indicate that there
was water in the bottom dome, but the data suggests it.  Net radiation values during the 
period are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D040813.8
Start DateStart TimeEnd DateEnd Time
08/10/2004192508/24/20041820
Subject:
SGP/EBBR/E7 - Pressure Too High
DataStreams:sgp30ebbrE7.b1
Description:
When data collection resumed after a missing period, the barometer pressure
had become very high, 102 kPa, which was not correct.  This condition resulted
from an incorrect calibration being used. Sensible heat flux was overestimated 
by about 4% and latent heat flux underestimated by about 4% because of the 
high pressure readings.
Measurements:sgp30ebbrE7.b1:
  • Atmospheric pressure(atmos_pressure)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D041005.3
Start DateStart TimeEnd DateEnd Time
08/04/2004170508/10/20041925
Subject:
SGP/EBBR/E7 - Data Missing
DataStreams:sgp30ebbrE7.b1
Description:
A power outage resulted in missing data for the indicated period.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D041222.10
Start DateStart TimeEnd DateEnd Time
10/05/2004163010/05/20041700
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp30ebbrE9.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D041222.8
Start DateStart TimeEnd DateEnd Time
10/05/2004200010/05/20042030
Subject:
SGP/EBBR/E7 - 6 Month Checks
DataStreams:sgp30ebbrE7.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D050113.2
Start DateStart TimeEnd DateEnd Time
12/01/2004083001/31/20051400
Subject:
SGP/EBBR/E9 - Wind Speed Threshhold Low
DataStreams:sgp30ebbrE9.b1
Description:
When the wind speed is very low, the anemometer cups stop turning.  Wind
speeds above the threshhold may be underestimated.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050114.7
Start DateStart TimeEnd DateEnd Time
10/01/1995000006/30/20032330
Subject:
SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9  - BA EBBR VAP Bulk Aerodynamics
DataStreams:sgp30baebbrE9.c1, sgp30baebbrE7.c1
Description:
Fixed AEM and wind speed sensor heights were improperly used in the calculation of bulk 
aerodynamic sensible and latent heat fluxes instead of site specific heights.

This resulted in either under-estimation or over-estimation of the sensible and latent 
heat fluxes.
Measurements:sgp30baebbrE7.c1:
  • austar
  • Heat flux, sensible, aerodynamic(ah)
  • Heat flux, latent, aerodynamic(ale)
  • Heat flux, latent, best estimate(ecomb)
  • Heat flux, sensible, best estimate(hcomb)

sgp30baebbrE9.c1:
  • Heat flux, sensible, best estimate(hcomb)
  • Heat flux, latent, aerodynamic(ale)
  • austar
  • Heat flux, latent, best estimate(ecomb)
  • Heat flux, sensible, aerodynamic(ah)


Back To Table of Contents

DQRID : D050206.6
Start DateStart TimeEnd DateEnd Time
01/04/2005145001/05/20050100
Subject:
SGP/EBBR/E7  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE7.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050206.8
Start DateStart TimeEnd DateEnd Time
01/04/2005150501/05/20050800
Subject:
SGP/EBBR/E9  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050207.4
Start DateStart TimeEnd DateEnd Time
01/04/2005175501/05/20050800
Subject:
SGP/EBBR/E9  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE9.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D050215.11
Start DateStart TimeEnd DateEnd Time
01/11/2005133001/12/20050050
Subject:
SGP/EBBR/E7  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE7.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050215.14
Start DateStart TimeEnd DateEnd Time
01/10/2005230001/11/20051645
Subject:
SGP/EBBR/E9  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE9.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D050215.15
Start DateStart TimeEnd DateEnd Time
02/08/2005053002/09/20051830
Subject:
SGP/EBBR/E9  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp30ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050330.2
Start DateStart TimeEnd DateEnd Time
03/08/2005194503/22/20051900
Subject:
SGP/EBBR/E7 - Wrong Datalogger Program
DataStreams:sgp30ebbrE7.b1
Description:
The wrong version 9 datalogger program (unit 12 instead of 13) was installed
during the period listed, causing soil heat flows to be 2 to 3 W m-2 too
high, pressure to be 0.35 kPa too high, and soil moistures to be 10% too low.

Effects on the sensible and latent heat flow are much smaller than the system error.
Measurements:sgp30ebbrE7.b1:
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • energy_storage_change_3
  • soil_moisture_5
  • energy_storage_change_4
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • corr_soil_heat_flow_1
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_capacity_3
  • surface_soil_heat_flux_2
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D050601.2
Start DateStart TimeEnd DateEnd Time
05/02/2005121506/11/20050600
Subject:
SGP/EBBR/E9 - Soil moisture too high
DataStreams:sgp30ebbrE9.b1
Description:
The 15 and 30 minute data for sm3 indicated that there was a problem with the sensor that 
kept the soil moisture artificially high.  This corrected itself on 6/11, but it is not 
clear why. 

A new sensor was installed on 6/17 and it has behaved well since then.
Measurements:sgp30ebbrE9.b1:
  • soil_moisture_3


Back To Table of Contents

DQRID : D050719.6
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051900
Subject:
SGP/EBBR/E7 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE7.b1
Description:
Effective 20050322.1900, the EBBR.E7 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE7.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE7.a1).
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D050719.8
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051600
Subject:
SGP/EBBR/E9 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE9.b1
Description:
Effective 20050322.1600, the EBBR.E9 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE9.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE9.a1).
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D051024.1
Start DateStart TimeEnd DateEnd Time
09/20/2005203010/07/20051530
Subject:
SGP/EBBR/E7 - Data Missing
DataStreams:sgp30ebbrE7.b1
Description:
Data was missing because of a communication problem.  However, previously
missing data from 10/07-18 was recovered from the EBRR storage module and ingested, 
thereby reducing the data lost period significantly.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D051104.1
Start DateStart TimeEnd DateEnd Time
10/31/2005090011/01/20051630
Subject:
SGP/EBBR/E9 - Net Radiation Incorrect: Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Water had entered the top of the net radiometer during the rain on 10/31 early morning.  
The net radiation, and thus sensible and latent heat fluxes were incorreect during the 
stated period.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D051106.20
Start DateStart TimeEnd DateEnd Time
03/08/2005200003/22/20051900
Subject:
SGP/EBBR/E7 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D051106.22
Start DateStart TimeEnd DateEnd Time
03/08/2005163003/22/20051600
Subject:
SGP/EBBR/E9 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D051106.3
Start DateStart TimeEnd DateEnd Time
09/14/2005000009/20/20052000
Subject:
SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The top dome of the net radiometer was cracked; net radiation, and sensible and latent 
heat flux measurements were incorrect.
Measurements:sgp30ebbrE7.b1:
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D051112.4
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E7 - metadata corrections
DataStreams:sgp30ebbrE7.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E7 data collected by ARM back to the installation of the 
instrument in May 1993. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE7.b1:
  • base_time


Back To Table of Contents

DQRID : D051112.6
Start DateStart TimeEnd DateEnd Time
10/13/2003000004/19/20052359
Subject:
SGP/EBBR/E9 - metadata corrections
DataStreams:sgp30ebbrE9.b1
Description:
On 20050420, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E9 data collected by ARM back to the installation of the 
instrument in December 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE9.b1:
  • base_time


Back To Table of Contents

DQRID : D051215.2
Start DateStart TimeEnd DateEnd Time
10/30/2005070011/01/20051615
Subject:
SGP/EBBR/E9 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The top dome of the net radiometer was broken, resulting in net radiations that were too 
small, and thus sensible and latent heat fluxes that were too small.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D060111.3
Start DateStart TimeEnd DateEnd Time
12/04/2005170002/20/20062230
Subject:
SGP/EBBR/E7 - Barometric Pressure Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The pressure measurement sometimes dropped to zero during daytime because of 
unstable battery voltage.
Measurements:sgp30ebbrE7.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D060501.4
Start DateStart TimeEnd DateEnd Time
03/21/2006100003/21/20062030
Subject:
SGP/EBBR/E7 - Fluxes and Gradient Measurements Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The left AEM aspirator was not working during this period, resulting in incorrect gradient 
and flux measurements.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D060621.7
Start DateStart TimeEnd DateEnd Time
04/30/2006223005/02/20061550
Subject:
SGP/EBBR/E9 - Wind Speed Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed measurement was incorrect after the cup anemometer lost a cup.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D070215.3
Start DateStart TimeEnd DateEnd Time
02/01/2007010002/20/20072100
Subject:
SGP/EBBR/E7 - Windspeed threshhold too high
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed sensor developed worn bearings and therefore too high a starting 
threshhold.

The data user should compare the EBBR wind speed with the SMOS wind speed to detect 
periods when the EBBR wind speed threshhold caused poor data quality.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D080102.2
Start DateStart TimeEnd DateEnd Time
12/22/2007150001/08/20081800
Subject:
SGP/EBBR/E9 - Net Radiation Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
There was water in the net radiometer.  

The net radiation data was incorrect.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D080212.1
Start DateStart TimeEnd DateEnd Time
02/21/2008123002/21/20082300
02/11/2008110002/12/20081730
Subject:
SGP/EBBR/E7  - Wind Speed Frozen Stopped
DataStreams:sgp30ebbrE7.b1
Description:
Freezing rain stopped wind speed sensor.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D090312.2
Start DateStart TimeEnd DateEnd Time
02/08/2009143004/15/20091800
Subject:
SGP/EBBR/E7 - AEM voltage too high
DataStreams:sgp30ebbrE7.b1
Description:
The AEM was putting out too high a home 30 voltage.

Sensible and latent flux data was affected by this condition, at first just at night, but 
later (especially after 03/17/09 0730 GMT) fluxes were affected during
all hours of the day.
Measurements:sgp30ebbrE7.b1:
  • home_signal_15
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • home_signal_30


Back To Table of Contents

DQRID : D090313.11
Start DateStart TimeEnd DateEnd Time
01/27/2009035001/28/20091910
Subject:
SGP/EBBR/E9 - Wind Speed Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D090428.1
Start DateStart TimeEnd DateEnd Time
04/20/2009183006/22/20091500
Subject:
SGP/EBBR/E7 - Fluxes intermittently incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Soil temperature #2 frequently spiked, causing incorrect sensible and latent heat fluxes. 
The condition was not always obvious from the qc checks.
Measurements:sgp30ebbrE7.b1:
  • Soil temperature mean 2(soil_temp_2)
  • energy_storage_change_2
  • soil_heat_capacity_2
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D090617.3
Start DateStart TimeEnd DateEnd Time
06/16/2009100006/22/20091500
Subject:
SGP/EBBR/E7 - Wind direction incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The wind direction flat-lined at ~10 degrees.  System was replaced.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D100202.2
Start DateStart TimeEnd DateEnd Time
01/03/2010140001/04/20100005
Subject:
SGP/EBBR/E7 - Wind speed frozen stopped
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D100521.2
Start DateStart TimeEnd DateEnd Time
03/20/2010173005/10/20101800
Subject:
SGP/EBBR/E9 - Sensible and latent heat flux incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Sensible and latent heat fluxes were sometimes incorrect when soil temperature 4 and soil 
moisture 4 were acting up.

Sometimes the sensible and latent heat fluxes are indicated as incorrect by an offscale 
reading produced by the data logger error checking routine.  This occurs mostly during 
daytime.  However, you will have to examine the soil moisture 4 and soil temperature 4 data 
to see when they were incorrect or offscale to determine all times for which sensible and 
latent heat fluxes were incorrect.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 4(soil_temp_4)
  • soil_moisture_4


Back To Table of Contents

DQRID : D100727.4
Start DateStart TimeEnd DateEnd Time
07/17/2010210507/22/20101600
Subject:
SGP/EBBR/E7 - Incorrect Sensible and Latent Heat Fluxes
DataStreams:sgp30ebbrE7.b1
Description:
Soil heat flow 4 failed.  Latent and sensible heat flux values were incorrect at times, 
when the EBBR program did not reject the incorrect soil heat flow.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • soil_heat_flow_4
  • Latent heat flux(latent_heat_flux)
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D101007.3
Start DateStart TimeEnd DateEnd Time
08/09/2010183010/06/20101830
Subject:
SGP/EBBR/E7 - Sensible and latent heat fluxes incorrect - soil heat flow 1 problem
DataStreams:sgp30ebbrE7.b1
Description:
Soil Heat Flow 1 was offscale at times, affecting sensible and latent heat fluxes during 
those times.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • surface_soil_heat_flux_1
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D101127.1
Start DateStart TimeEnd DateEnd Time
09/28/2010163010/06/20102130
Subject:
SGP/EBBR/E9 - T/RH Probe Temperature Problem - Sensible and Latent Heat Fluxes Affected
DataStreams:sgp30ebbrE9.b1
Description:
During mid-day the left T/RH probe temperature was offscale, sometimes resulting in 
incorrect sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D110105.4
Start DateStart TimeEnd DateEnd Time
10/14/2010080012/07/20101600
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The right Air Temperature probe leads were loose.
During nighttime the right Air Temperature went offscale,
resulting in incorrect sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D110830.2
Start DateStart TimeEnd DateEnd Time
06/09/2011050009/29/20111600
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The AEM stuck in the home 15 or home 30 position, resulting in incorrect sensible and 
latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D110830.3
Start DateStart TimeEnd DateEnd Time
07/21/2011203008/03/20111930
Subject:
SGP/EBBR/E7 - Loose connection (ST #3)
DataStreams:sgp30ebbrE7.b1
Description:
Soil temperature 3 was going offscale at times due to loose connections.  Sensible and 
latent heat fluxes were not affected.
Measurements:sgp30ebbrE7.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_3
  • soil_heat_capacity_3
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D111011.2
Start DateStart TimeEnd DateEnd Time
09/03/2011133009/28/20111900
Subject:
SGP/EBBR/E7 - Sensible and Latent Heat Flux Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
Latent and sensible heat flux were incorrect because the AEM was not working properly.
Measurements:sgp30ebbrE7.b1:
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D130114.1
Start DateStart TimeEnd DateEnd Time
08/05/2012040001/10/20131900
Subject:
SGP/EBBR/E9 - Sensible and latent heat flux sometimes incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil temperature 3 was usually several degrees lower than the other four soil temperature 
measurements and usually did not follow a diurnal trend.

Soil moisture 3 was usually ten to thirty percent higher than the other four soil moisture 
measurements and usually did not follow a diurnal trend.

Avoid derived latent and sensible heat fluxes at times when the soil_temp_3 deviates from 
the other soil_temp_[1,2,4] by more than 1 C, or the soil_moisture_3 deviates from the 
other soil_moisture_[1,2,4] by more than 10%.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Soil temperature mean 3(soil_temp_3)
  • soil_heat_capacity_3
  • soil_heat_flow_3
  • surface_soil_heat_flux_3
  • Sensible heat flux(sensible_heat_flux)
  • soil_moisture_3
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_3


Back To Table of Contents

DQRID : D130410.1
Start DateStart TimeEnd DateEnd Time
11/08/2012134011/19/20122000
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Net Radiation was incorrect, thus latent and sensible heat fluxes were incorrect.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D130410.2
Start DateStart TimeEnd DateEnd Time
02/20/2013190002/27/20132000
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Battery voltage was low, leading to many incorrect measurements, including sensible and 
latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D130410.3
Start DateStart TimeEnd DateEnd Time
03/24/2013070003/25/20131830
Subject:
SGP/EBBR/E9 - AEM hung
DataStreams:sgp30ebbrE9.b1
Description:
The AEM hung in between positions, causing sensible and latent heat fluxes to be 
incorrect.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D130423.3
Start DateStart TimeEnd DateEnd Time
04/10/2013110004/22/20131800
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Voltage issues. Latent and sensible heat fluxes missing during AEM malfunction.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D141010.5
Start DateStart TimeEnd DateEnd Time
09/20/2014220010/08/20141700
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Sensible and Latent Heat Fluxes incorrect because the automatic exchange mechanism was not 
working.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D141103.2
Start DateStart TimeEnd DateEnd Time
10/18/2014010010/31/20141800
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Sensible and latent heat fluxes were incorrect at times, when the AEM did not work 
correctly.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D151113.4
Start DateStart TimeEnd DateEnd Time
10/22/2015020011/04/20151830
Subject:
SGP/EBBR/E9 -  Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Sensible and latent heat fluxes were incorrect while the AEM was not working.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D151201.2
Start DateStart TimeEnd DateEnd Time
11/27/2015000011/30/20152359
Subject:
SGP ALL INSTRUMENTS - Icing Event
DataStreams:sgp30baebbrE9.c1, sgp30ebbrE9.b1
Description:
An icing event (winter storm Cara) passed slowly through the area during this time frame.  
Instruments at the SGP may have been affected by ice accumulation.
Measurements:sgp30ebbrE9.b1:
  • Atmospheric pressure(atmos_pressure)
  • Latent heat flux(latent_heat_flux)
  • temp_trh_top
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • vapor_pressure_bottom
  • soil_heat_flow_3
  • temp_air_bottom
  • Wind direction vector mean(wdir_vec_mean)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • home_signal_30
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Net radiation(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_moisture_1
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top

sgp30baebbrE9.c1:
  • vp_top
  • vegetation_height
  • tref
  • ces5
  • ces4
  • ces3
  • ces2
  • ces1
  • ts4
  • ts5
  • ts1
  • ts2
  • ts3
  • hum_bot
  • tair_bot
  • hum_top
  • thum_top
  • Heat flux, sensible, aerodynamic(ah)
  • home_30
  • Heat flux, sensible, best estimate(hcomb)
  • tair_top
  • vp_bot
  • Average soil heat flux(ave_shf)
  • bowen
  • thum_bot
  • Heat flux, latent, best estimate(ecomb)
  • cs2
  • shf2
  • cs1
  • shf3
  • cs4
  • shf1
  • cs3
  • home_15
  • cs5
  • shf4
  • shf5
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • wind_d
  • specific humidity(q)
  • g4
  • g5
  • g2
  • g3
  • res_ws
  • g1
  • wind_s
  • Corrected sensible heat flux(h)
  • Heat flux, latent(e)
  • sm3
  • sm4
  • Heat flux, latent, aerodynamic(ale)
  • sm5
  • c_shf5
  • c_shf4
  • austar
  • c_shf1
  • c_shf3
  • c_shf2
  • sm2
  • sm1
  • sigma_wd


Back To Table of Contents

DQRID : D160603.2
Start DateStart TimeEnd DateEnd Time
05/25/2016020006/01/20161800
Subject:
SGP/EBBR/E9 - Data Missing or Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
All data were incorrect or missing because the power supply failed.
Measurements:sgp30ebbrE9.b1:
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Atmospheric pressure(atmos_pressure)
  • home_signal_30
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Net radiation(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • temp_trh_top
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_heat_flow_5
  • qc_wspd_vec_mean
  • soil_heat_flow_2
  • soil_heat_flow_1
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • temp_air_bottom
  • soil_heat_flow_3
  • soil_moisture_1
  • Wind direction vector mean(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D931108.6
Start DateStart TimeEnd DateEnd Time
07/11/1993030011/01/19931700
Subject:
SGP/EBBR/E9 - pressure calibration
DataStreams:sgp30ebbrE9.b1
Description:
In the original Campbell CR10 software provided by the vendor (version 1),
the EBBR had incorrect calibration pressure sensor slopes and offsets.
The slopes and offset was carried through into version 2 of the
software and was not discovered by the mentor (me) until sometime later.
The calibration and slope did not deleteriously affect calculations in
the program since only a four percent reduction in atmospheric pressure
measurement resulted (the calculations are not very sensitive to small
errors in pressure). The vendor does not recall how the wrong
calibrations came to be used.   

Version 4 of the CR10 program includes the proper calibration and offset. 
This remedies the apparent offset problem (it was actually a calibration 
and offset problem). In comparisons with the co-located SMOS pressure
sensor, the difference between the SMOS and EBBR pressure values appeared
almost constant with time, hence the assumption of an offset problem.
However, the EBBR pressure sensor offsets are so large (a consequence of
tailoring the calibration curve to a small range of elevations in which the
calibration applies) that the very small error in slope was difficult to
recognize.

The outputted pressure values for the EBBR system can be corrected
with the following information and equations.  

         Old Slope     Old Offset        New Slope     New Offset

          0.01952        81.24            0.02031        81.27

   Correct Pressure =
               ((Current Pressure Data - 81.24)*0.02031/0.01952) + 81.27
                    =  1.04047*(Current Pressure Data) - 3.258
Measurements:sgp30ebbrE9.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents

DQRID : D940301.4
Start DateStart TimeEnd DateEnd Time
02/23/1994103002/24/19941540
Subject:
Invalid wind speed frozen sensor
DataStreams:sgp30ebbrE7.b1
Description:
ARM PROBLEM IDENTIFICATION FORM (PIF)

                            PIF No. P940301.4

Submitted By:        David R. Cook
    Organization:    Argonne National Laboratory
    Date Submitted:  March 1, 1994

Problem Description/Change Description.

o For Instrument Problems ONLY,
        Identify MODE of Operation:  Degraded

o Give a brief explanation with details, attach examples and any supporting
  information.  This should include a description of analysis leading to
  identification of problem and, if known, recommended action.


This is an informational PIF.

On February 23, 1994 the EBBR wind speed sensor at E7, Elk Falls, KS was
frozen to a stationary condition by ice.  Invalid data for the time period
indicated is:

30 minute: wind_s, res_ws

15 minute: wind_s

5 minute: wind_s, res_ws.


How may we contact you?
    e-mail:  cook@anler.er.anl.gov
    phone:   (708) 252-5840
    FAX:     (708) 252-9792

Submitter's Priority: 3
    [Critical-1   Very Important-2 Important-3 Inconvenient-4 Interesting-5]

Where was this Problem Identified: FI
    [Site Data System-SDS      Experiment Center-EC]
    [Archive-A At              Field Instrument-FI ]
    [During Data Analyis-DA    Other- List Location]

Does this PIF result in a Software Change Request?  NO
    Where:                     [ SDS,  EC, or  A ]

    Type:                      [Development-1 Problem-2  Enhancement-3]

    List Programs/Documents Affected:

    Configuration Identification:

Does problem impact data values or cause data loss?  Data Loss.
    which platform(s):  EBBR, E7, Elk Falls, KS

    Specify (or estimate) begin and end dates for data loss
          Begin Date    2/23/94   Time  1030  GMT
          End   Date    2/23/94   Time  1540  GMT

    Apparent cause of data loss, if known:   Ice

    SUGGESTED CAUSES:
    [human error, component failure, temperature, lightning          ]
    [foreign matter, power loss, software failure,                   ]
    [communications failure, modification difficulites, specify other]
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D940301.6
Start DateStart TimeEnd DateEnd Time
02/23/1994040002/24/19941300
Subject:
SGP/EBBR/E9 - Invalid wind speed frozen sensor
DataStreams:sgp30ebbrE9.b1
Description:
On February 23, 1994 the EBBR wind speed sensor at E9, Ashton, KS was
frozen to a stationary condition by ice.  It broke free in strong winds on
February 24, 1994.  Invalid data for the time period indicated is:

30 minute: wind_s, res_ws

15 minute: wind_s

5 minute: wind_s, res_ws.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D940329.3
Start DateStart TimeEnd DateEnd Time
07/11/1993150103/22/19941643
Subject:
SGP/E9/EBBR - AEM Malfunction
DataStreams:sgp30ebbrE9.b1
Description:
EDITOR'S NOTE:  This DQR refers, in part, to data collected prior to the
begin date of regular ARM data.  During the first month covered by this
DQR, the EBBR.E9 data were not archived with standard ARM names.  The data
are therefore not readily available, but can be made available by special
request.  The total period covered by the problem documented here is
930615.0000-940322.1643.

The AEM at E9 frequently did not function properly during the time period
stated.  Please see the notes in the EBBR platform describing home signal
conditions for which certain of the data fields are suspect.  The newly
installed AEM is performing properly so far.

The files could be flagged, but it is up to the user to read the
platform notes concerning the condition of the home signal and then
view the quality of the data accordingly.  I would be at my terminal full-
time in attempting to list all days and times and data fields that are
affected by the numerous AEM malfunctions.  Furthermore, I have done so
previously in several PIFs that I will reference here for information:
P931101.4, P931115.2, P940105.2, P940211.3
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • home_signal_30
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • home_signal_15
  • rh_top_fraction


Back To Table of Contents

DQRID : D940503.1
Start DateStart TimeEnd DateEnd Time
04/05/1994150004/19/19941525
Subject:
SGP/EBBR/E9 - AEM failure
DataStreams:sgp30ebbrE9.b1
Description:
The Automatic Exchange Mechanism would not function.  It was decided to
take the unit back to SGP CART to try to repair it.  A spare AEM was not
available for a replacement, so the aspirated radiation shields housing
temperature and humidity gradient sensors were attached to the EBBR
framework, one meter apart vertically, with the right side in the lower
position.  The housings remained this way for two weeks.  During this time
period, home signal, sensible heat flux, and latent heat flux values are
incorrect.  Significant reprocessing would be required to obtain correct
fluxes, and that would be possible only if one assumed that offsets in the
sensor calibrations are negligible; that is a very debatable assumption
considering that the EBBR system is already half a year past due for
calibration.
Measurements:sgp30ebbrE9.b1:
  • home_signal_30
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • home_signal_15


Back To Table of Contents

DQRID : D940711.2
Start DateStart TimeEnd DateEnd Time
06/18/1994020006/25/19941930
06/25/1994230006/28/19941600
06/15/1994230006/16/19940030
06/15/1994210006/15/19942130
06/16/1994213006/17/19941530
06/17/1994190006/17/19941930
Subject:
SGP/EBBR/E9 - Reprocessing Notice (RID 13)
DataStreams:sgp30ebbrE9.b1
Description:
See below for details of reprocessing that was completed on 20150121. Original DQR 
category: 4 (Red, Incorrect)

-------------------------------------------------------------------------------

Failure of soil heat flow sensor #5 at E9, Ashton, KS resulted in incorrect
data values for 6 fields for much of the period of time listed above.  The
soil heat flow values from #5 were so large (in the absolute) that it
deleteriosly affected the soil heat flux average and the sensible and
latent heat fluxes.  The fields affected were:

30 minute: shf5, c_shf5, g5, ave_shf, e, h

15 minute: mv_hft5.

I list only the 30 minute times affected below; it can be assumed that the
15 minute value contained in the half hour are incorrect.  Sensor #5 was
replaced at 1545 GMT on June 28.  Old S/N 923029, new S/N 923092.  Half hour
1600 GMT is missing due to having to reload the CR10 program with a new shf5
calibration.  Sensible and latent heat fluxes can be recomputed by averaging
soil heat flow sensors 1-4; use the following equations:

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q +ave_shf)/(1 + bowen)

h = e * bowen,

where g is total soil heat flow, q is net radiation, and bowen is Bowen
Ratio.

Affected half hours:

Date          Times (GMT)

6/15    2130, 2300, 2330
6/16    0000, 0030, 2130-2330
6/17    0000-1530, 1900, 1930
6/18    0200-2330
6/19    All
6/20    All
6/21    All
6/22    All
6/23    All
6/24    All
6/25    0000-1930, 2300, 2330
6/26    All
6/27    All
6/28    0000-1600
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D940711.4
Start DateStart TimeEnd DateEnd Time
06/28/1994170006/29/19941700
Subject:
SGP/EBBR/E7 - Reprocess: Soil Temperature Probe Failure
DataStreams:sgp30ebbrE7.b1
Description:
Failure of soil temperature probe #4 at E7, Elk Falls, KS resulted in incorrect
data values for 6 fields for the period of time listed above.  The soil
temperature value from probe #4 went offscale, resulting in a zero value
for the soil energy storage term calculated from that probe and thus no
contribution to the total soil heat flux for soils set 4 and the same for
average soil heat flux.  This led to incorrect sensible and latent heat
flux values.

The fields affected were:

30 minute: ts4, ces4, g4, ave_shf, e, h

15 minute: rr_ts4.
Measurements:sgp30ebbrE7.b1:
  • Soil temperature mean 4(soil_temp_4)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D940826.1
Start DateStart TimeEnd DateEnd Time
08/19/1994010008/23/19941530
Subject:
SGP/EBBR/E9 - Malfunctioning Wind Dir Sensor, Incorrect SM2 Results
DataStreams:sgp30ebbrE9.b1
Description:
It has been reported previously that a malfunction of the wind direction
sensor resulting in zero or 135 degree outputs can cause the soil moisture
#2 sensor to read offscale.  The two sensors are attached to a multiplexer
pair.  The manufacturer of the multiplexer and data acquisition system have
not been able to explain how our instrument configuration can cause this
effect.  Shortly after 0030 GMT on August 20, 1994 significant rainfall
occurred, being reflected in more than a doubling of soil moisture within
an hour.  During the time period listed above, the wind direction sensor
mulfunctioned (apparently caused by water in the wind direction sensor
electronics), causing the following data fields to be incorrect:

5 minute:  res_ws, wind_d, sigma_wd

15 minute: mv_wind_dir

30 minute: res_ws, wind_d, sigma_wd.

During part of the listed period, Soil Moisture #2 was also incorrect,
being offscale; during those times the following 30 minute data is also
incorrect:

30 minute: sm2, c_shf2, ave_shf, cs2, ces2, g2, h, e.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D940826.2
Start DateStart TimeEnd DateEnd Time
08/17/1994170008/17/19942300
Subject:
SGP/EBBR/E9 - Reprocess: Soil Heat Flux Out of Range
DataStreams:sgp30ebbrE9.b1
Description:
For an unknown reason, soil heat flux sensor #5 indicated too small a value
for the period listed above.  This resulted in an incorrect average of soil
heat flow for the five sets of soil heat flow plates, and therefore
incorrect e (latent heat flux) and h (sensible heat flux) in the 30 minute
data.  The following data values are incorrect:

15 minute: mv_hft5

30 minute: shf5, c_shf5, ave_shf, g5, e, h

The latent and sensible heat flux can be recalculated by using only soil
heat flows 1 through 4 to calculate the average soil heat flow,

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q).
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D940830.7
Start DateStart TimeEnd DateEnd Time
08/20/1994013008/23/19941600
Subject:
SGP/EBBR/E9 - Hail Damage to Net Radiometer and Wind Speed Sensor
DataStreams:sgp30ebbrE9.b1
Description:
Golf ball size hail was reported for the Ashton site for early August 20,
1994.  It damaged the wind speed sensor and the net radiometer shortly
before 0130 GMT.  The following data fields are to be flagged as incorrect
for the periods listed above (resultant wind speed has already been
indicated as incorrect in a previous DQR that documented the malfunction of
the wind direction sensor):

5 minute:  wind_s, res_ws, q

15 minute: wind_s, mv_q

30 minute: wind_s, res_ws, q, h, e.

Note that h and e are also incorrect as a consequence of q being incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D940830.8
Start DateStart TimeEnd DateEnd Time
08/09/1994000008/23/19941922
Subject:
Stopped Ventilation Fan
DataStreams:sgp30ebbrE7.b1
Description:
DQR No:                               Platform: EBBR

Subject: Stopped Ventilation Fan

Date Submitted: 30 August 1994
Submitted By:                         _x_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
        What level data: (raw,a0,a1,b1,c1 etc): a0 (5 minute),
                                                a1 (15 and 30 minute)

    What location was the data collected at: E7, Elk Falls, KS

    Period of time in question
        Begin Date 8/9/94
        End Date   8/23/94   Time 1922 GMT

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 ___  incorrect                         _x_  Only some data fields affected
 ___  wrong calibration
 _x_  others (information only)

 Discussion of Problem:

Sometime between August 9 and 23, 1994 the ventilation fan of the
EBBR stopped; the fan guard was clogged with insect remains.  The fan was
restarted at 1922 GMT on 23 August.  Inspection of the EBBR data does not
indicate any ill affects on the calculated sensible and latent heat during
the period.  The fan may have stopped soon before the arrival of the site
operator on 23 August.  I cannot suggest flagging the data as incorrect, but
this message should still be attached to the data so that anyone who might
discover something unusual may have some basis for explaining it.

The quantities that are normally affected by stoppage of the ventilation to
the temperature and relative humidity sensors are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

Other observations/measurements impacted by this problem:

see list above

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Enclose the message above with the data if possible.

Data Processing Notes                Date

-------------------------------------------------------------------
END
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D940926.1
Start DateStart TimeEnd DateEnd Time
08/18/1994120009/21/19941530
Subject:
Intermittent Stopped or Slowed Aspirator Fans
DataStreams:sgp30ebbrE7.b1
Description:
DQR No:                               Platform: EBBR

Subject: Intermittent Stopped or Slowed Aspirator Fans

Date Submitted: 26 September 1994
Submitted By:                         _x_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: EBBR/T and RH
        What level data: (raw,a0,a1,b1,c1 etc): a0 (5 minute),
                                                a1 (15 and 30 minute)

    What location was the data collected at: E7, Elk Falls, KS

    Period of time in question
        Begin Date 8/18/94   Time 1200 GMT
        End Date   9/21/94   Time 1530 GMT

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _x_  Only some data fields affected
 ___  wrong calibration
 ___  others (information only)

 Discussion of Problem:

Around 1200 GMT on September 21, 1994 the aspirator fans of the EBBR
intermittently stopped or slowed significantly; the fans were clogged with
insect remains and spider webs.  Only a few weeks earlier the same
situation occurred at this EBBR.  The 15 minute data reveals that most of
the time the right aspirator fan was the one that failed to work, although
there are times that it appears that the left fan was either not working
also or was the only one not working.  Unlike the previous occurrence, the
30 minute flux data does show some indication of this problem, although, as
usual, it is far easier to see in the 15 minute data.  The fans were cleaned
out and restarted at 1530 GMT on September 21, 1994.  The data listed below
should be flagged as incorrect for the period shown above.

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

Other observations/measurements impacted by this problem:

see list above

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Enclose the message above with the data if possible.

Data Processing Notes                Date

-------------------------------------------------------------------
END
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D941114.3
Start DateStart TimeEnd DateEnd Time
10/20/1994000011/01/19941540
Subject:
SGP/EBBR/E7 - Net Radiometer not level
DataStreams:sgp30ebbrE7.b1
Description:
Sometime between 0000 and 1200 GMT on October 20, 1994, the net radiometer
support of the EBBR at E7 was bent down at about a 30 degree angle, probably
by migrating birds.  A couple of DQRs have been issued by me indicating other
extended facilities at which birds have caused incorrect data from net
radiometers.  The net radiometer support was probably loose to begin with.
The effect can be easily seen in the data, when comparison is made to the
EBBR data at Ashton, KS.  Since the net radiometer support extends south
from the EBBR, the net radiation values are high during the period above,
leading to incorrect values of latent and sensible heat fluxes.  Until the
net radiometer was levelled on November 1, 1994, the net radiation was
approximately 26% high at solar noon, although it may have been incorrect
by a smaller percentage at night.  From October 22 through 28 the half hour
of data nearest solar noon averaged 497 watts per meter squared at Elk
Falls and only 396 at Ashton.  During the period listed above, the following
data are incorrect and cannot be recalculated:

5 minute:  q

15 minute: mv_q

30 minute: q, h, e

Science Team members or others using the data should recognize that the
flux data is not correct for this fairly lengthy time period.
Measurements:sgp30ebbrE7.b1:
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D941208.2
Start DateStart TimeEnd DateEnd Time
11/15/1994230011/30/19941600
Subject:
SGP/EBBR/E7 - Radiation Shield Problem
DataStreams:sgp30ebbrE7.b1
Description:
The right radiation shield was out of position or off during the period of
time indicated.  This may or may not have occurred as a result of preventative
maintenance on November 15.  All air and humidity probe temperatures (except
the reference temperature), relative humidities, vapor pressures, Bowen ratio,
sensible heat flux, and latent heat flux during this period are questionable.
During a large part of the period the resultant sensible and latent heat fluxes
look reasonable.  However, during part of the period, the difference in
relative humidity between the two EBBR levels appears to be much too large.
Unusual differences in temperatures are not as obvious.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D941220.3
Start DateStart TimeEnd DateEnd Time
12/14/1994160012/14/19941630
Subject:
SGP/EBBR/E7 - Water in Net Radiometer
DataStreams:sgp30ebbrE7.b1
Description:
A small amount of water collected in the bottom dome of the net radiometer.
It is not obvious that it had been there for more than several hours before
the site operators arrived for a preventative maintenance visit and there
is no evidence of any effects on the data (there had been heavy cloudiness
for the previous several hours).  The only incorrect data occurred
during the removal of the water.  The dome was not replaced.  The following
data is incorrect between 1600 and 1630 GMT on December 14, 1994:

5 minute:  q

15 minute: mv_q

30 minute: q, e, h
Measurements:sgp30ebbrE7.b1:
  • Net radiation(net_radiation)
  • Latent heat flux(latent_heat_flux)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D950126.2
Start DateStart TimeEnd DateEnd Time
01/05/1995220001/09/19950230
10/28/1994203010/28/19942230
10/13/1994180010/14/19941500
01/02/1995060001/05/19951700
12/27/1994160012/27/19941630
01/14/1995080001/15/19950300
10/17/1994203010/17/19942100
01/09/1995090001/14/19950400
08/19/1994170008/19/19942300
12/20/1994063012/23/19940530
01/15/1995120001/16/19951600
12/26/1994170012/27/19940130
Subject:
SGP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Data
DataStreams:sgp30ebbrE9.b1
Description:
Soil heat flow sensor #5 periodically outputted incorrect values from
mid-August 1994 until mid-January 1995.  The output often indicated large
negative heat flow.  The sensor was replaced on January 23, 1995, even
though the previous week of data was correct.  The data affected (and thus
incorrect) includes:

15 minute: mv_hft5
30 minute: shf5, c_shf5, g5, ave_shf, e, h.

The dates and times (GMT) of incorrect values are listed below.  Only half
hour times are listed.

08/19/94  1700-2300
10/13/94  1800-2330
10/14/94  0000-1500
10/17/94  2030-2100
10/28/94  2030-2230
12/20/94  0630-2330
12/21/94  0000-2330
12/22/94  0000-2330
12/23/94  0000-0530
12/26/94  1700-2330
12/27/94  0000-0130, 1630
01/02/95  0600-2330
01/03/95  0000-2330
01/04/95  0000-2330
01/05/95  0000-1700, 2200-2330
01/06/95  0000-2330
01/07/95  0000-2330
01/08/95  0000-2330
01/09/95  0000-0230, 0900-2330
01/10/95  0000-2330
01/11/95  0000-2330
01/12/95  0000-2330
01/13/95  0000-2330
01/14/95  0000-0400, 0800-2330
01/15/95  0000-0300, 1200-2330
01/16/95  0000-1600

The latent and sensible heat fluxes can be recalculated by using only soil
heat flows 1 through 4 to calculate the average soil heat flow,

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q)
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D950308.2
Start DateStart TimeEnd DateEnd Time
02/21/1995003002/21/19951600
Subject:
SGP/EBBR/E9 - Radiation Shield Problem
DataStreams:sgp30ebbrE9.b1
Description:
The left radiation shield was off during the period of time above.  Close
inspection of the 15 minute data was required to detect when the shield
fell off.  As is often the case in such a situation, the 30 minute data
does not adequately indicate such a failure.  A radiation shield has fallen off
of an EBBR before, apparently a result of vibration of the AEM during
exchanges.  All air and humidity probe temperatures (except the reference
temperature), relative humidities, vapor pressures, Bowen ratio, sensible heat
flux, and latent heat flux during this period are considered to be incorrect.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D950626.11
Start DateStart TimeEnd DateEnd Time
04/18/1995013004/18/19951620
Subject:
SGP/EBBR/E9 - Stopped Ventilation Fan
DataStreams:sgp30ebbrE9.b1
Description:
On April 18, 1995, a site operator discovered the right aspirator ventilation
fan of the EBBR to be stopped.  Inspection of the data indicates that this
condition began early in the GMT day.  Interpretation of the start time of
the condition is made more difficult by a slight bias low in absolute
temperature in comparison to the left temperature probe.  Lack of ventilation
of the temperature and relative humidity sensors attached to the AEM results
in incorrect measurements of air temperature and relative humidity by the
right aspirator probes, and therefore all quantities calculated from them,
including sensible and latent heat fluxes, are incorrect as well.
The quantities that are incorrect for the period above are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, mv_hum_r, tair_r

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D950626.12
Start DateStart TimeEnd DateEnd Time
04/18/1995113004/18/19951530
Subject:
SGP/EBBR/E9 - Water in Net Radiometer
DataStreams:sgp30ebbrE9.b1
Description:
The top dome of the net radiometer was broken and a small amount of water
had collected in the bottom dome of the net radiometer.  It is not obvious
that it had been there for more than several hours before the site operators
arrived for a preventative maintenance visit.  There are noticable effects on
the data for the period listed above.  The domes were replaced.  The following
data is incorrect for the period above:

5 minute:  q

15 minute: mv_q

30 minute: q, e, h
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D950626.6
Start DateStart TimeEnd DateEnd Time
03/07/1995024503/08/19951640
Subject:
SGP/EBBR/E9 - Frozen Wind Speed Sensor
DataStreams:sgp30ebbrE9.b1
Description:
On March 7, 1995 freezing rain stopped the cups of the EBBR wind
speed instrument at Ashton, KS (E9).  All 5, 15, and 30
minute data values indicated below are incorrect for the period listed above.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D950626.8
Start DateStart TimeEnd DateEnd Time
03/11/1995010003/11/19950600
03/11/1995153003/12/19951930
03/16/1995183003/18/19951100
03/13/1995043003/13/19950500
03/19/1995210003/20/19950400
03/10/1995210003/10/19952130
03/20/1995153003/20/19951700
Subject:
SBP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Data
DataStreams:sgp30ebbrE9.b1
Description:
Soil heat flow sensor #5 periodically outputted incorrect values during the
period above.  The output often indicated large negative heat flow.  The
sensor connections were tightened on March 20, 1995, which seems to have
corrected the problem.  The data affected (and thus incorrect) includes:

15 minute: mv_hft5
30 minute: shf5, c_shf5, g5, ave_shf, e, h.

The dates and times (GMT) of incorrect values are listed below.  Only half
hour times are listed.

03/10/95  2130
03/11/95  0100-0600, 1530-2330
03/12/95  0000-1930
03/13/95  0500
03/16/95  1830-2330
03/17/95  0000-2330
03/18/95  0000-1100
03/19/95  2100-2330
03/20/95  0000-0400, 1530-1700

The latent and sensible heat fluxes can be recalculated by using only soil
heat flows 1 through 4 to calculate the average soil heat flow,

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q)
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D951020.1
Start DateStart TimeEnd DateEnd Time
10/05/1995153010/05/19951830
Subject:
SGP/EBBR/E9 - 3-month Check
DataStreams:sgp30ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D951116.5
Start DateStart TimeEnd DateEnd Time
11/11/1995014511/11/19951600
Subject:
SGP/EBBR/E9 - AEM Exchange Stopped in Snow and Freezing Rain
DataStreams:sgp30ebbrE9.b1
Description:
On the night of November 10-11, a north-south line from south central
Kansas through south central Oklahoma received snow and freezing rain and experienced 
below freezing temperatures.  This caused the EBBR automatic exchange mechanism (AEM) to stop 
exchanging temporarily.   

Note that temperatures, relative humidities, and vapor pressures are not affected; these 
are correct as measured, but the height at which the measurements occurred must be 
determined from the home signal value.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D951127.1
Start DateStart TimeEnd DateEnd Time
11/15/1995123011/15/19952100
Subject:
SGP/EBBR/E9 - Annual calibration changeout
DataStreams:sgp30ebbrE9.b1
Description:
On November 15, 1995 the changeout for annual calibration occurred at E9,
Ashton, KS.  SEBS unit 4 was removed and unit 6 was installed.  Between
1230 and 2100 GMT no data was collected; data during this period is missing.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Atmospheric pressure(atmos_pressure)
  • home_signal_30
  • Latent heat flux(latent_heat_flux)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • Soil temperature mean 3(soil_temp_3)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 1(soil_temp_1)
  • Net radiation(net_radiation)
  • rh_top_fraction
  • base_time
  • East longitude(lon)
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • temp_trh_top
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • soil_heat_flow_3
  • temp_air_bottom
  • soil_moisture_1
  • Wind direction vector mean(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • time_offset
  • Altitude above mean sea level(alt)
  • soil_moisture_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Sensible heat flux(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • North latitude(lat)
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D951221.1
Start DateStart TimeEnd DateEnd Time
11/02/1995153011/28/19952200
Subject:
Annual calibration changeout
DataStreams:sgp30ebbrE7.b1
Description:
DQR No:                               Platform: EBBR

Subject:  Annual Calibration Changeout - E7, Elk Falls, KS

Date Submitted:  December 21, 1995
Submitted By:                         _x_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: EBBR/Changeout
        What level data: (raw,a0,a1,b1,c1 etc): a1 (5 and 30 minute)
                                                a0 (15 minute)

    What location was the data collected at: E7, Elk Falls, KS

    Period of time in question
        Begin Date 11/02/95   Time 1530 GMT
        End Date   11/28/95   Time 2200 GMT

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
                                             part of the period)
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:

On November 2, 1995 the changeout for annual calibration occurred at E7,
Elk Falls, KS.  SEBS unit 9 was removed and unit 12 was installed.  Between
1530 and 1930 GMT no data was collected.  The soil moisture probes were
shipped dry from the vendor.  Site operations did not realize this and
installed them without wetting the bags that hold the soil moisture probes
in soil.  The water did not penetrate into the bags of soil.  Therefore, some
soil moisture probe outputs were initially offscale.  Different soil
moisture probes indicated offscale at different times until 28 November
1995.  On 28 November, site operations soaked the soil moisture probe bags
with water, causing the soil moisture data values to come on scale.

No data was collected during the time of the installation on November 2,
between 1530 and 1930 GMT.

The incorrect soil moisture after SEBS 12 was installed affected numerous
data values including:

15 minute:  rr_sm1, rr_sm2, rr_sm3, rr_sm4, rr_sm5

30 minute:  h, e, ave_shf, shf1, shf2, shf3, shf4, shf5, sm1, sm2, sm3,
            sm4, sm5, cs1, cs2, cs3, cs4, cs5, ces1, ces2, ces3, ces4,
            g1, g2, g3, g4, g5.

Inspection of the data readily shows which soil moisture probes were
offscale.  When one or more were offscale, the e, h, and ave_shf data and the
respective numbered data variables above were incorrect.  h and e can be
recalculated using only correct soil moisture probe values and equations shown
in many previous DQRs.


Other observations/measurements impacted by this problem:

see above

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data with this comment.

Data Processing Notes                Date

-------------------------------------------------------------------
END
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D960104.5
Start DateStart TimeEnd DateEnd Time
12/19/1995104012/19/19951650
Subject:
SGP/EBBR/E7 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE7.b1
Description:
Freezing rain, snow, and below freezing conditions during 19 January
1995 caused the wind speed sensor cups to freeze in a stopped state at E7,
Elk Falls, KS on 19 January 1995.  When temperatures rose to above freezing
later that day, the ice thawed and the cups turned freely again.

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D960119.5
Start DateStart TimeEnd DateEnd Time
01/07/1996053001/09/19961730
Subject:
SGP/EBBR/E7 - Soil Moisture Probes Offscale
DataStreams:sgp30ebbrE7.b1
Description:
DQR No:                               Platform: EBBR

Subject: E7 Soil Moisture Probes Offscale

Date Submitted:  January 19, 1996
Submitted By:                         _x_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: EBBR/Soil Moisture Probes
        What level data: (raw,a0,a1,b1,c1 etc): a1 (15 and 30 minute)

  What location was the data collected at: E7, Elk Falls, KS

  Period of time in question (Times vary for different days)

        Date 01/07/96   Time 0530-2400 GMT  Probe sm2
                             0530-2130 GMT        sm4
                             1100-1900 GMT        sm5
             01/08/96        0000-2400 GMT        sm2
                             0130-2300 GMT        sm4
                             0130-2030 GMT        sm5
             01/09/96        0000-2200 GMT        sm2
                             1130-1900 GMT        sm4
                             1130-1730 GMT        sm5

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:

During numerous periods within the days listed above, individual soil moisture
probes indicated high or offscale, on the dry side.  The cause of the
problems is unknown.  Data since 9 January 1996 has been correct.
Recalculation of ave_shf, e, and h must be made using only the soil moisture
sets with correct soil moisture values.

Affected data values are (# for probe number):

15 minute: rr_sm#

30 minute: sm#, c_shf#, cs#, ces#, g#, ave_shf, e, h

Sensible, latent, and soil heat fluxes can be recalculated using the soil
probe sets that provide correct data.  For example, if soil moisture 2 is
incorrect,

ave_shf = (g1 + g3 + g4 + g5)/4

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),


If soil moisture 2 and 4 are incorrect,

ave_shf = (g1 + g3 + g5)/3

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),


If soil moisture 2, 4, and 5 are incorrect,

ave_shf = (g1 + g3)/2

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),

Other observations/measurements impacted by this problem:

see above

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data with this comment.

Data Processing Notes                Date

-------------------------------------------------------------------
END
Measurements:sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_moisture_1
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • surface_soil_heat_flux_1
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_capacity_3
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_4
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_3
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D960320.2
Start DateStart TimeEnd DateEnd Time
01/23/1996050001/24/19961830
Subject:
SGP/EBBR/E7 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE7.b1
Description:
Freezing rain, snow, and below freezing conditions during 23 January 
1996 caused the wind speed sensor cups to freeze in a stopped state at E7, 
Elk Falls, KS on 23 January 1996.  When temperatures rose to above freezing  
on 24 January 1996, the ice thawed and the cups turned freely again. 

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D960321.1
Start DateStart TimeEnd DateEnd Time
01/23/1996045001/23/19961555
Subject:
SGP/EBBR/E9 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE9.b1
Description:
Freezing rain, snow, and below freezing conditions during 23 January 
1996 caused the wind speed sensor cups to freeze in a stopped state at E9, 
Ashton, KS.  Site operations personnel removed the ice from the cups later 
in the day to allow them to turn freely again. 

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D960508.2
Start DateStart TimeEnd DateEnd Time
05/02/1996144105/02/19961512
Subject:
SGP/EBBR/E7 - 3-month check
DataStreams:sgp30ebbrE7.b1
Description:
During EBBR 3-month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D960508.4
Start DateStart TimeEnd DateEnd Time
04/30/1996173104/30/19961800
Subject:
SGP/EBBR/E9 - 3-month check
DataStreams:sgp30ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D961122.10
Start DateStart TimeEnd DateEnd Time
09/20/1996143009/20/19961500
Subject:
SGP/EBBR/E9 - Air Temperature Thermocouples Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Both air temperature thermocouples were offscale, for unknown reasons, for 
1500 GMT for both 15 and 30 minute air temperature values.

The malfunction of the air temperature thermocouples results in incorrect Bowen 
ratio, sensible heat flux, and latent heat flux during the period above. 

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_r, tair_l

30 minute: tair_top, tair_bot, bowen, e, and h
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D961122.20
Start DateStart TimeEnd DateEnd Time
11/13/1996151611/13/19961552
Subject:
SGP/EBBR/E7 - EBBR 3-Month Checks - 10 EFs
DataStreams:sgp30ebbrE7.b1
Description:
During EBBR 3-month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D961122.22
Start DateStart TimeEnd DateEnd Time
11/15/1996155711/15/19961630
Subject:
SGP/EBBR/E9 - EBBR 3 Month Checks - 10 EFs
DataStreams:sgp30ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D970330.4
Start DateStart TimeEnd DateEnd Time
01/23/1996050001/24/19961830
Subject:
SGP/EBBR/E7- Wind Speed Cups Frozen
DataStreams:sgp30ebbrE7.b1
Description:
Freezing rain, snow, and below freezing conditions during 23 January 
1996 caused the wind speed sensor cups to freeze in a stopped state at E7, 
Elk Falls, KS on 23 January 1996.  When temperatures rose to above freezing  
on 24 January 1996, the ice thawed and the cups turned freely again. 

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D970623.2
Start DateStart TimeEnd DateEnd Time
07/15/1996171506/18/19971645
Subject:
SGP/EBBR/E9 - Temperature Portion of T/RH Probe
DataStreams:sgp30ebbrE9.b1
Description:
The Temperature portion of the right T/RH probe indicated too high a 
temperature for nearly 11 months.  I twice placed work requests to have the 
probe replaced, but no spares were available.  Spares recently became 
available and I placed a new work request to have the probe changed.  The 
replacement occurred on 18 June 1997; this fixed the problem.  The main 
results of the high temperatures were probe top and bottom temperatures
(used only for the calculation of vapor pressure) and vapor pressures that 
were too large.  Furthermore, this caused latent heat flux to be reported 
to be too large, and therefore sensible heat flux was reported to be too 
small.  Recalculation of the fluxes using thermocouple temperatures to 
calculate vapor pressure would be quite time consuming and would have to
assume that the thermocouple temperature and probe temperature were nearly 
the same.

The EBBR procedures have been changed to include comparison of the 
thermocouple and probe temperatures to make it easier for the site 
operators to detect this condition.

The data affected (and thus incorrect) includes:

15 minute: rr_thum_r 
30 minute: thum_top, thum_bot, vp_top, vp_bot, e, h, bowen.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D971021.1
Start DateStart TimeEnd DateEnd Time
04/16/1997153304/16/19971625
Subject:
SGP/EBBR/E7 - EBBR Biannual Checks
DataStreams:sgp30ebbrE7.b1
Description:
During EBBR 6-month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D971021.3
Start DateStart TimeEnd DateEnd Time
04/15/1997184504/15/19971915
Subject:
SGP/EBBR/E9 - EBBR Biannual Checks
DataStreams:sgp30ebbrE9.b1
Description:
During EBBR 6 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D971027.8
Start DateStart TimeEnd DateEnd Time
08/10/1997000009/30/19971550
Subject:
SGP/EBBR/E9 - Wind Direction Sensor Malfunction
DataStreams:sgp30ebbrE9.b1
Description:
During numerous intermittent times during the period listed, the wind direction
sensor at E9, Ashton, KS malfunctioned, putting out a value of 135.  The
sensor was replaced on 30 September 1997, at 1550 GMT.  All wind direction data
with values of 135 during the period listed should be considered incorrect.
The affected data are:

 5 minute: res_ws, wind_d, sigma_d

15 minute: mv_wind_d

30 minute: res_ws, wind_d, sigma_d
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D980117.13
Start DateStart TimeEnd DateEnd Time
12/21/1997071512/21/19971115
01/04/1998074501/05/19981710
01/09/1998094501/09/19981610
Subject:
SGP/EBBR/E9 - EBBR Frozen Wind Speed
DataStreams:sgp30ebbrE9.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980117.15
Start DateStart TimeEnd DateEnd Time
01/08/1998085001/08/19981645
01/04/1998095001/04/19981950
Subject:
SGP/EBBR/E7 - EBBR Frozen Wind Speed
DataStreams:sgp30ebbrE7.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980117.25
Start DateStart TimeEnd DateEnd Time
01/04/1998184501/08/19981715
Subject:
SGP/EBBR/E9 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)
DataStreams:sgp30ebbrE9.b1
Description:
The EBBR AEM stopped exchanging because of icing at during this time
period.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for the time period indicated.  The other
measurements listed  are also incorrect for those times:
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D980117.31
Start DateStart TimeEnd DateEnd Time
12/24/1997163001/08/19981800
Subject:
SGP/EBBR/E9 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affected
DataStreams:sgp30ebbrE9.b1
Description:
The upper dome of the EBBR net radiometers was punctured.
After the puncture, water collected in the top and/or bottom dome.  The
water was removed and the dome was replaced during PM visits. 

 In some cases, the puncture and water resulted in incorrect data. 
Comparison with net radiation values from surrounding EBBR sites and the
SIRS is neccesary to determine if the EBBR net radiation data 
are correct or incorrect.

It is often difficult to tell from the data when the punctures occurred,
but they would have existed for no more than 2 weeks, since the domes
are checked during each two-weekly PM visit.

Incorrect net radiation data results in the latent heat flux and
sensible heat flux also being incorrect.
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D980410.1
Start DateStart TimeEnd DateEnd Time
11/28/1997160002/04/19982230
Subject:
SGP/EBBR/E7 - Right T/RH Probe Temperature Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The temperature portion of the right T/RH probe was reporting too high for
the period.   The following fields are incorrect:
 
 5 minute: thum_top, thum_bot, vp_top, vp_bot
15 minute: rr_thum-r
30 minute: thum_top, thum_bot, vp_top, vp_bot, e, h, bowen
Measurements:sgp30ebbrE7.b1:
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D980410.3
Start DateStart TimeEnd DateEnd Time
01/14/1998043001/14/19981830
Subject:
SGP/EBBR/E7 - Wind Speed Sensor Frozen
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed sensor was frozen stalled during this period.
Data values that were affected are:

 5 minute: wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980410.5
Start DateStart TimeEnd DateEnd Time
01/14/1998050001/15/19980030
Subject:
SGP/EBBR/E9 - Wind Speed Sensor Frozen
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed sensor was frozen stalled during this period. 

Data values that were affected are:

 5 minute: wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980416.10
Start DateStart TimeEnd DateEnd Time
10/16/1997192810/16/19972002
Subject:
SGP/EBBR/E9 - 3-Month Check
DataStreams:sgp30ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period above.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D980416.8
Start DateStart TimeEnd DateEnd Time
10/16/1997152810/16/19971602
Subject:
SGP/EBBR/E7 - 3-Month Check
DataStreams:sgp30ebbrE7.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period above.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D980529.6
Start DateStart TimeEnd DateEnd Time
05/12/1998194005/12/19982037
Subject:
SGP/EBBR/E7 - Six-Month Checks
DataStreams:sgp30ebbrE7.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period above.
Measurements:sgp30ebbrE7.b1:
  • rh_bottom_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • temp_air_bottom
  • Latent heat flux(latent_heat_flux)
  • vapor_pressure_bottom
  • Sensible heat flux(sensible_heat_flux)
  • bowen_ratio


Back To Table of Contents

DQRID : D980529.8
Start DateStart TimeEnd DateEnd Time
05/14/1998174005/14/19981759
Subject:
SGP/EBBR/E9 - Six Month Checks
DataStreams:sgp30ebbrE9.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period above.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents

DQRID : D981113.2
Start DateStart TimeEnd DateEnd Time
10/28/1998155910/28/19981600
Subject:
SGP/EBBR/E7 - Data Incorrect Because of Recompile
DataStreams:sgp30ebbrE7.b1
Description:
All data for the 5, 15, and 30 minute periods ending at 1600 GMT are
incorrect or missing because the CR10 program was recompiled.
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Net radiation(net_radiation)
  • temp_reference
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_1
  • soil_moisture_2
  • soil_heat_flow_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • North latitude(lat)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_moisture_1
  • Atmospheric pressure(atmos_pressure)
  • soil_heat_capacity_1
  • surface_soil_heat_flux_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_5
  • Latent heat flux(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind direction vector mean(wdir_vec_mean)
  • Soil temperature mean 4(soil_temp_4)
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • Altitude above mean sea level(alt)
  • base_time
  • bowen_ratio
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • time_offset
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • corr_soil_heat_flow_4
  • vapor_pressure_bottom
  • Soil temperature mean 1(soil_temp_1)
  • East longitude(lon)
  • rh_top_fraction
  • vapor_pressure_top
  • home_signal_15
  • Sensible heat flux(sensible_heat_flux)


Back To Table of Contents

DQRID : D990127.12
Start DateStart TimeEnd DateEnd Time
11/12/1998210011/25/19981830
Subject:
SGP/EBBR/E9 - Wind Direction Data Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind direction sensor stopped working correctly, resulting in the
following values being affected:

5 minute:  res_ws, wind_d, sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D990127.22
Start DateStart TimeEnd DateEnd Time
12/22/1998100512/22/19981600
Subject:
SGP/EBBR/E7 - Wind Direction Data Incorrect (revised)
DataStreams:sgp30ebbrE7.b1
Description:
The wind direction sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  res_ws, wind_d, sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE7.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction vector mean(wdir_vec_mean)


Back To Table of Contents

DQRID : D990127.8
Start DateStart TimeEnd DateEnd Time
11/12/1998123011/12/19982000
Subject:
SGP/EBBR/E9 - EBBR E9 Net Radiometer Dome Broken, Flux Data Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Incorrect Net Radiation values resulted in incorrect sensible and 
latent heat fluxes. Affected values are:

5 minute:   q
15 minute:  mv_q
30 minute:  q, e, h
Measurements:sgp30ebbrE9.b1:
  • Net radiation(net_radiation)
  • Sensible heat flux(sensible_heat_flux)
  • Latent heat flux(latent_heat_flux)


Back To Table of Contents

DQRID : D990128.3
Start DateStart TimeEnd DateEnd Time
01/01/1999150501/03/19992100
Subject:
SGP/EBBR/E7 - EBBR E7 Wind Speed Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990128.4
Start DateStart TimeEnd DateEnd Time
01/08/1999103501/08/19992300
Subject:
SGP/EBBR/E7 - Wind Speed Data Incorrect
DataStreams:sgp30ebbrE7.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE7.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990128.6
Start DateStart TimeEnd DateEnd Time
01/01/1999151501/03/19991830
Subject:
SGP/EBBR/E9 - Wind Speed Data Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990128.7
Start DateStart TimeEnd DateEnd Time
01/08/1999060501/08/19991900
Subject:
SGP/EBBR/E9 - Wind Speed Data Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990622.5
Start DateStart TimeEnd DateEnd Time
04/22/1999075004/29/19991850
Subject:
SGP/EBBR/E9 - Wind Speed Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The wind speed sensor lost two of the three cups.  Flux data is not 
affected.  The data values affected are:

5 minute: wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990623.1
Start DateStart TimeEnd DateEnd Time
05/13/1999123006/11/19991645
Subject:
SGP/EBBR/E9 - Right Aspirator Not Working
DataStreams:sgp30ebbrE9.b1
Description:
The result of the right aspirator not working was a reduction in measured
temperature gradient and thus a reduction in estimated sensible heat flux
and an increase in latent heat flux.  The fluxes could be in error by as
much as 10%.  Reported right air and humidity probe temperatures, top and 
bottom air and humidity probe temperatures, right relative humidity, and 
top and bottom vapor pressure are affected.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • Sensible heat flux(sensible_heat_flux)
  • temp_air_top
  • Latent heat flux(latent_heat_flux)
  • rh_top_fraction


Back To Table of Contents