D000127.2SGP/MWR - MWR Scaled sondes too wetsgplssondeC1.c1
D020909.1SGP/SONDE/C1 - Bad Temperature SensorsgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020909.2SGP/SONDE/C1 - Bad Temperature SensorsgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D021006.1Bad temperature sensorsgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030411.3SGP/Sonde/C1 - Failed Sonde Launches due to Antenna problemssgplssondeC1.c1, sgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D050912.2SGP/SONDE/C1 - Temperature/RH incorrectsgplssondeC1.c1, sgpsondewnpnC1.b1


DQRID : D000127.2
Start DateStart TimeEnd DateEnd Time
12/03/1999053112/04/19990530
Subject:
SGP/MWR - MWR Scaled sondes too wet
DataStreams:sgplssondeC1.c1
Description:
As discussed in P000109.1, two of the MWR scaled radiosondes were 
scaled such that the relative humidity profiles greatly exceeded
100% RH for large fractions of the profile.  The two launches that
were affected were on 991203.0531 and 991204.0530.  In both cases,
the scale factor was on the order of 1.9.  Users should beware of
all MWR scaled radiosondes with scale factors outside the range of
0.8 - 1.2.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D020909.1
Start DateStart TimeEnd DateEnd Time
09/06/2002172709/06/20021854
Subject:
SGP/SONDE/C1 - Bad Temperature Sensor
DataStreams:sgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the temperature sensor broke upon launch and therefore the reported 
temperature is approximately 40 degC too low.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)

sgpqmemwrcolC1.c1:
  • Water vapor, total integrated from radiosonde(integ_vap_sonde)

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D020909.2
Start DateStart TimeEnd DateEnd Time
09/06/2002052709/06/20020718
Subject:
SGP/SONDE/C1 - Bad Temperature Sensor
DataStreams:sgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the temperature sensor broke shortly after launch. Temperatures are offset 
by approxmiately (but not constantly) 40 degC.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)

sgpqmemwrcolC1.c1:
  • Water vapor, total integrated from radiosonde(integ_vap_sonde)

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D021006.1
Start DateStart TimeEnd DateEnd Time
10/03/2002112010/03/20021320
Subject:
Bad temperature sensor
DataStreams:sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the temperture sensor broke a few seconds into flight.  This results in an 
unreasonably low temperature for the rest of the flight.  For some reason, the rh values 
also go missing shortly after launch.  Only the wind and pressure data are reliable.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)
  • alt

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • asc
  • alt
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • asc
  • Dry Bulb Temperature(tdry)
  • alt


Back To Table of Contents

DQRID : D030411.3
Start DateStart TimeEnd DateEnd Time
04/01/2003173004/01/20031930
04/02/2003053004/02/20030730
04/02/2003113004/02/20031330
Subject:
SGP/Sonde/C1 - Failed Sonde Launches due to Antenna problems
DataStreams:sgplssondeC1.c1, sgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
These sonde launches where unsuccessful due to problems
with the antenna configuration resulting in signal loss
before the launch.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • lat
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Dry Bulb Temperature(tdry)
  • alt
  • time_offset
  • lon
  • base_time

sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Eastward Wind Component(u_wind)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • time_offset
  • lat
  • alt
  • wstat
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • lon
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • wstat
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • Northward Wind Component(v_wind)
  • alt
  • lat
  • base_time
  • Eastward Wind Component(u_wind)
  • time_offset
  • Dry Bulb Temperature(tdry)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D050912.2
Start DateStart TimeEnd DateEnd Time
09/09/2005113209/09/20051332
Subject:
SGP/SONDE/C1 - Temperature/RH incorrect
DataStreams:sgplssondeC1.c1, sgpsondewnpnC1.b1
Description:
The temperature throughout this sounding is too high and as a result the RH values will be 
incorrect as well.  I'm not sure what is wrong here but the operators noted reasonable 
values (18.1 degC, 87%) in the log before launch.  Review of the raw data, however, shows 
the sonde reporting temperatures nearly 20 degC higher.  I suppose it is possible that 
the operator entered into the log the reference temperature from the GC25 ground check set 
rather than the temperature reported by the sonde - I can't think of any other 
explanation - there is no doubt that the temperature sensor on this sonde was bad.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents