Data Quality Reports for Session: 152162 User: shafians1 Completed: 08/09/2013


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D030711.4SGP/EBBR/E27 - Reference T Sensor Failuresgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030711.5SGP/EBBR/E27 - Wind Direction Hungsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030712.24SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030919.12SGP/EBBR/E27 - Water in Net Radiometer; Surface Fluxes are Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030922.7SGP/EBBR/E27 - Right Air Temperature Spiked Offscalesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031021.3SGP/EBBR/E27 - Missing data during system updatesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031117.3SGP/EBBR/E27 - Right Air Temperature Spiked Offscalesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031204.22SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040304.25SGP/EBBR/E27 - Wind Speed Frozen Stopped By Icesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040507.3SGP/EBBR/E27 - Right Air Temperature Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040706.3SGP/EBBR/E27 - Loose Tair Left Connectionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D041222.19SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D050206.17SGP/EBBR/E27 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D050207.13SGP/EBBR/E27 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051106.15SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051106.16SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredtsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051112.10SGP/EBBR/E27 - metadata correctionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060425.1SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060501.27SGP/EBBR/E27 - Flux and Gradient Measurements Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060712.1SGP/EBBR/E27 - Field fire burned AEMsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060809.2SGP/EBBR/E27 - Low Battery Conditionsgp30ebbrE27.b1, sgp5ebbrE27.b1, sgp15ebbrE27.b1
D060818.11SGP/EBBR/E27 - Most Measurements Suspectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060818.13SGP/EBBR/E27 - Battery Voltage Problem - Measurements Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D070809.1SGP/EBBR/E27 - Multiplexer #2 failuresgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D080114.3SGP/EBBR/E27 - Measurements offscalesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D090313.9SGP/EBBR/E27 - Wind Speed Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1


DQRID : D030711.4
Start DateStart TimeEnd DateEnd Time
05/07/2003103005/15/20031600
05/18/2003180005/28/20031700
Subject:
SGP/EBBR/E27 - Reference T Sensor Failure
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The reference T sensor was not working much of the time, affecting 
all other temperature sensors.  Sensible and latent heat fluxes
were incorrect when this occurred.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_reference
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right
  • temp_air_left
  • temp_reference_rr

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_reference
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D030711.5
Start DateStart TimeEnd DateEnd Time
05/07/2003103006/12/20031800
Subject:
SGP/EBBR/E27 - Wind Direction Hung
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The Wind Direction frequently hung at values in the 70s or 80s.

No other data was affected. Fluxes were not affected.
Measurements:sgp5ebbrE27.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv

sgp30ebbrE27.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D030712.24
Start DateStart TimeEnd DateEnd Time
05/15/2003160005/15/20031645
Subject:
SGP/EBBR/E27 -  6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • temp_trh_left_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D030919.12
Start DateStart TimeEnd DateEnd Time
08/30/2003063009/03/20031700
Subject:
SGP/EBBR/E27  - Water in Net Radiometer; Surface Fluxes are Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp5ebbrE27.b1:
  • Radiation, net(net_radiation)

sgp15ebbrE27.b1:
  • net_radiation_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D030922.7
Start DateStart TimeEnd DateEnd Time
10/15/2003103011/17/20030630
Subject:
SGP/EBBR/E27 - Right Air Temperature Spiked Offscale
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature was going offscale at times.
This problem seemed to end without Site Ops. intervention.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D031021.3
Start DateStart TimeEnd DateEnd Time
10/29/2003170010/29/20031930
Subject:
SGP/EBBR/E27 - Missing data during system update
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Some soil parameters were slightly incorrect since EBBR.E27 was 
                 installed in May 2003.  While the coefficients were being updated,
                 data collection was suspended resulting in missing data for the 
                 specified period.
                    No significant effects (1% or less) on the surface heat flux data 
                 would have occurred from using the slightly incorrect coefficients. 
                 Therefore, flagging of the surface flux data from the time of 
                 installation of E27 is unwarranted.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • base_time
  • temp_reference
  • vapor_pressure_bottom
  • lon
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • time
  • Wind speed vector mean(wspd_vec_mean)
  • lat
  • wdir_vec_std
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • temp_air_top
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • Barometric Pressure(atmos_pressure)
  • alt
  • time_offset
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • lon
  • soil_moisture_1_rr
  • soil_moisture_3_rr
  • battery_voltage
  • time_offset
  • soil_temp_5_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • alt
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • lat
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • temp_trh_right_rr
  • rh_right_mv
  • base_time
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • time_offset
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • lon
  • Barometric Pressure(atmos_pressure)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • corr_soil_heat_flow_2
  • vapor_pressure_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • home_signal_30
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • soil_moisture_2
  • Soil temperature mean 4(soil_temp_4)
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • soil_moisture_4
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • soil_moisture_5
  • base_time
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • lat
  • alt
  • wdir_vec_std
  • home_signal_15
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D031117.3
Start DateStart TimeEnd DateEnd Time
09/06/2003120010/11/20030730
Subject:
SGP/EBBR/E27 - Right Air Temperature Spiked Offscale
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature was going offscale at times.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D031204.22
Start DateStart TimeEnd DateEnd Time
10/29/2003183010/29/20031945
Subject:
SGP/EBBR/E27 - 6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • temp_trh_left_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D040304.25
Start DateStart TimeEnd DateEnd Time
02/02/2004070502/02/20041800
02/05/2004020502/05/20040600
Subject:
SGP/EBBR/E27  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp5ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040507.3
Start DateStart TimeEnd DateEnd Time
03/01/2004000003/31/20042355
Subject:
SGP/EBBR/E27  - Right Air Temperature Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature, and therefore top and bottom air temperatures
were offscale or incorrect on occasion.  Bowen ratio, sensible heat flux, and latent heat 
flux were also incorrect during those times.

Inspection of the data is required to detect the incorrect periods.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D040706.3
Start DateStart TimeEnd DateEnd Time
06/10/2004060007/21/20041725
Subject:
SGP/EBBR/E27 - Loose Tair Left Connections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Tair left dropped out at times. When this occurred, the sensible and latent heat fluxes 
are incorrect.

Tightening of the electronic connections to the datalogging equipment
appears to have solved the problem.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_left

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D041222.19
Start DateStart TimeEnd DateEnd Time
09/29/2004200009/29/20042030
Subject:
SGP/EBBR/E27 - 6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • temp_trh_left_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D050206.17
Start DateStart TimeEnd DateEnd Time
01/05/2005155501/07/20051605
Subject:
SGP/EBBR/E27  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp5ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp15ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050207.13
Start DateStart TimeEnd DateEnd Time
01/06/2005100501/07/20051430
Subject:
SGP/EBBR/E27  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp5ebbrE27.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv

sgp30ebbrE27.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D051106.15
Start DateStart TimeEnd DateEnd Time
08/05/2005220008/17/20051600
Subject:
SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The net radiometer top dome was broken and water got inside, making the net radiation, and 
sensible and latent heat flux measurements incorrect.
Measurements:sgp5ebbrE27.b1:
  • Radiation, net(net_radiation)

sgp15ebbrE27.b1:
  • net_radiation_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D051106.16
Start DateStart TimeEnd DateEnd Time
08/17/2005163008/27/20051930
Subject:
SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredt
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Residual Moisture left in the top dome of the net radiometer after the 8/17/05 servicing 
caused the net radiation measurements to be biased low, and resulting in sensible and 
latent heat flux being low also.
Measurements:sgp5ebbrE27.b1:
  • Radiation, net(net_radiation)

sgp15ebbrE27.b1:
  • net_radiation_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D051112.10
Start DateStart TimeEnd DateEnd Time
10/13/2003000008/16/20052359
Subject:
SGP/EBBR/E27 - metadata corrections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
On 20050816, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E27 data collected by ARM back to the installation of the 
instrument in May 2003. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp5ebbrE27.b1:
  • base_time

sgp15ebbrE27.b1:
  • base_time

sgp30ebbrE27.b1:
  • base_time


Back To Table of Contents

DQRID : D060425.1
Start DateStart TimeEnd DateEnd Time
03/03/2006000005/10/20061130
05/25/2006210006/20/20061730
Subject:
SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The left T/RH probe temperature sensor was spiking some of the time during these periods. 
Therefore, sensible and latent heat fluxes were incorrect during parts of the periods as 
well.
Measurements:sgp5ebbrE27.b1:
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • bowen_ratio


Back To Table of Contents

DQRID : D060501.27
Start DateStart TimeEnd DateEnd Time
02/18/2006033003/01/20061615
Subject:
SGP/EBBR/E27 - Flux and Gradient Measurements Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The sensible and latent heat flux and gradient measurements were incorrect
while the AEM was hung in one position.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • temp_trh_left_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D060712.1
Start DateStart TimeEnd DateEnd Time
07/11/2006013007/21/20061730
Subject:
SGP/EBBR/E27 - Field fire burned AEM
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
A fire in the E27 field burned the AEM, making it non-functional.
Sensible and latent heat fluxes and gradients were incorrect during this period.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • home_signal
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • home_signal
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • temp_trh_left_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • home_signal_30
  • rh_bottom_fraction
  • home_signal_15
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D060809.2
Start DateStart TimeEnd DateEnd Time
05/31/2006060006/07/20061730
06/14/2006050006/20/20061730
Subject:
SGP/EBBR/E27 - Low Battery Condition
DataStreams:sgp30ebbrE27.b1, sgp5ebbrE27.b1, sgp15ebbrE27.b1
Description:
A low battery condition caused most of the measurements to be incorrect.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • temp_reference
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • time
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • temp_air_top
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_1_rr
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • temp_trh_right_rr
  • rh_right_mv
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Barometric Pressure(atmos_pressure)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • home_signal_30
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • Soil temperature mean 4(soil_temp_4)
  • soil_moisture_2
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_4
  • Soil temperature mean 3(soil_temp_3)
  • soil_moisture_5
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • wdir_vec_std
  • home_signal_15
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D060818.11
Start DateStart TimeEnd DateEnd Time
04/26/2006183008/17/20061730
Subject:
SGP/EBBR/E27 - Most Measurements Suspect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wrong EBBR program was used at this site.  Therefore, most of the measurements are 
suspect.

Note: Mentor reports reprocessing will not correct this problem.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • base_time
  • temp_reference
  • vapor_pressure_bottom
  • lon
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • time
  • Wind speed vector mean(wspd_vec_mean)
  • lat
  • wdir_vec_std
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • temp_air_top
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • Barometric Pressure(atmos_pressure)
  • alt
  • time_offset
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • lon
  • soil_moisture_3_rr
  • soil_moisture_1_rr
  • battery_voltage
  • time_offset
  • soil_temp_5_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • alt
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • lat
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • temp_trh_right_rr
  • rh_right_mv
  • base_time
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • time_offset
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • lon
  • Barometric Pressure(atmos_pressure)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • corr_soil_heat_flow_2
  • vapor_pressure_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • home_signal_30
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • soil_moisture_2
  • Soil temperature mean 4(soil_temp_4)
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • soil_moisture_4
  • Soil temperature mean 2(soil_temp_2)
  • Soil temperature mean 3(soil_temp_3)
  • soil_moisture_5
  • base_time
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • lat
  • alt
  • wdir_vec_std
  • home_signal_15
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D060818.13
Start DateStart TimeEnd DateEnd Time
08/11/2006130008/21/20062330
Subject:
SGP/EBBR/E27 - Battery Voltage Problem - Measurements Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Battery voltage was too low much of the time during the period, thus most measurements 
were incorrect during much of the time period.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • temp_reference
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_bottom_fraction
  • temp_air_top
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_moisture_1_rr
  • soil_temp_5_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • temp_trh_right_rr
  • rh_right_mv
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Barometric Pressure(atmos_pressure)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • corr_soil_heat_flow_2
  • vapor_pressure_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • home_signal_30
  • soil_moisture_1
  • Soil temperature mean 1(soil_temp_1)
  • soil_moisture_2
  • Soil temperature mean 4(soil_temp_4)
  • soil_moisture_3
  • Soil temperature mean 5(soil_temp_5)
  • soil_moisture_4
  • Soil temperature mean 2(soil_temp_2)
  • soil_moisture_5
  • Soil temperature mean 3(soil_temp_3)
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • wdir_vec_std
  • home_signal_15
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D070809.1
Start DateStart TimeEnd DateEnd Time
08/07/2007213008/13/20071600
08/19/2007130008/29/20072130
Subject:
SGP/EBBR/E27 - Multiplexer #2 failure
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
A problem with the #2 Multiplexer caused a large number of measurements to be incorrect.  
Sensible and latent heat fluxes were often affected.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top

sgp15ebbrE27.b1:
  • soil_heat_flow_2_mv
  • soil_heat_flow_4_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • temp_air_left
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • rh_right_mv
  • net_radiation_mv
  • temp_air_right
  • rh_left_mv

sgp30ebbrE27.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • Radiation, net(net_radiation)
  • home_signal_30
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • corr_soil_heat_flow_1
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • home_signal_15
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_bottom
  • corr_soil_heat_flow_2
  • bowen_ratio
  • vapor_pressure_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D080114.3
Start DateStart TimeEnd DateEnd Time
12/22/2007180003/26/20081730
Subject:
SGP/EBBR/E27 - Measurements offscale
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
All J-panel 4 measurements (soil heat flows, net radiation, air temperatures, home 
signals, pressure, vapor pressure) were sometimes offscale or otherwise incorrect.  J-Panel was 
replaced 20080326 correcting the problem.
Measurements:sgp5ebbrE27.b1:
  • temp_air_bottom
  • temp_air_top
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • soil_heat_flow_2_mv
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • atmos_pressure_mv
  • soil_heat_flow_4_mv
  • net_radiation_mv
  • temp_air_right
  • soil_heat_flow_1_mv
  • temp_air_left

sgp30ebbrE27.b1:
  • corr_soil_heat_flow_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_heat_flow_1
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • Radiation, net(net_radiation)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • home_signal_30
  • Barometric Pressure(atmos_pressure)
  • home_signal_15
  • temp_air_bottom
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D090313.9
Start DateStart TimeEnd DateEnd Time
01/26/2009180001/28/20092145
Subject:
SGP/EBBR/E27 - Wind Speed Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp5ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE27.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents



END OF DATA