Data Quality Reports for Session: 150746 User: ps Completed: 06/10/2013


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D120113.6SGP/IRT/C1 - Noisy 10m IRT datasgpirt10mC1.b1
D121022.1SGP/IRT/C1 - Measurement rangesgpirt10mC1.b1, sgpirt25mC1.b1
D130211.1SGP/IRT/C1 - 10m IRT ground surface temperaturesgpirt10mC1.b1


DQRID : D120113.6
Start DateStart TimeEnd DateEnd Time
01/03/2012153001/04/20122030
Subject:
SGP/IRT/C1 - Noisy 10m IRT data
DataStreams:sgpirt10mC1.b1
Description:
The 10M IRT surface temperatures were very noisy because the connection to the data logger 
had become loose.
Measurements:sgpirt10mC1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • internal_voltage
  • sfc_ir_temp_std
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • logger_temp


Back To Table of Contents

DQRID : D121022.1
Start DateStart TimeEnd DateEnd Time
06/25/2012180008/04/20122059
Subject:
SGP/IRT/C1 - Measurement range
DataStreams:sgpirt10mC1.b1, sgpirt25mC1.b1
Description:
The ground surface temperature exceeded the maximum measurement of 50C on some days. The 
maximum was increased to 60C for IRT10m on 10/1/2012 at 15:25 and for IRT25m on 10/9/2012 
at 21:45.
Measurements:sgpirt25mC1.b1:
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)

sgpirt10mC1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)


Back To Table of Contents

DQRID : D130211.1
Start DateStart TimeEnd DateEnd Time
11/11/2012075002/08/20131525
Subject:
SGP/IRT/C1 - 10m IRT ground surface temperature
DataStreams:sgpirt10mC1.b1
Description:
The 10m IRT was measuring lower ground surface temperature than the 25m IRT. The lens was 
cleaned on 12/19/2012 and replaced on 2/8/2013 but the difference in temperature appears 
to be due to the seasonal difference in surface cover - tall grass vesus bare soil.
Measurements:sgpirt10mC1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • sfc_ir_temp_std
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)


Back To Table of Contents



END OF DATA