DQR ID | Subject | Data Streams Affected |
---|---|---|
D120507.1 | PGH/NFOV/M1 - Instrument noise/interference | pghnfov2chM1.b1 |
D120629.1 | PGH/MET/M1 - Site installation | pghmetM1.b1 |
D120629.2 | PGH/MET/M1 - Incorrect atmospheric pressure data | pghmetM1.b1 |
D120629.3 | PGH/MET/M1 - PWD spikes and missing data prior to revised install | pghmetM1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/22/2011 | 0000 | 01/23/2012 | 1200 |
Subject: | PGH/NFOV/M1 - Instrument noise/interference |
DataStreams: | pghnfov2chM1.b1 |
Description: | When the signals are very low, a regular feature can be seen in the data. It begins on the hour, and lasts for ~20 minutes. This feature is a rise in the signal of 0.25 to 0.33 mV. It is small even when compared with the NFOV's typically small signals. My initial hunch is the NFOV is located next to or nearby equipment that operates/broadcasts/etc beginning on the hour, and lasting for ~20 minutes. Looking (very closely) back at the previous deployment, this regular signal bump is also evident, so it seems the equipment contaminating the NFOV is part of the AMF1, and not unique to this deployment. 20111222 is a good example of the issue. |
Measurements: | pghnfov2chM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/09/2011 | 0000 | 06/11/2011 | 2359 |
Subject: | PGH/MET/M1 - Site installation |
DataStreams: | pghmetM1.b1 |
Description: | Site installation during this time. Data not reliable. |
Measurements: | pghmetM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2011 | 1837 | 07/06/2011 | 0318 |
Subject: | PGH/MET/M1 - Incorrect atmospheric pressure data |
DataStreams: | pghmetM1.b1 |
Description: | Logger was reprogrammed following revised installation. An error with the timing sequence for the barometer caused incorrect readings until the program was reverted on 7/6. |
Measurements: | pghmetM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/09/2011 | 0000 | 07/12/2011 | 1522 |
Subject: | PGH/MET/M1 - PWD spikes and missing data prior to revised install |
DataStreams: | pghmetM1.b1 |
Description: | The PWD was not installed efficiently, leading to occasional spikes and a period of missing data from 7/6 - 7/12 until revised installation took place and the programming was updated. |
Measurements: | pghmetM1.b1:
|