DQRID : D100106.1
Start DateStart TimeEnd DateEnd Time
11/25/2009173312/10/20092121
Subject:
SGP/MET/E9 - Wind Speed Data Incorrect
DataStreams:sgpmetE9.b1
Description:
Wind speed sensor reference wire became detached.  This caused all wind sensor data to 
report near 0 m/s.
Measurements:sgpmetE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • qc_wspd_vec_mean
  • qc_wspd_arith_mean
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D110524.3
Start DateStart TimeEnd DateEnd Time
05/03/2010000005/07/20100215
Subject:
SGP/MET/E9 - Time-stamp uncertainty
DataStreams:sgpmetE9.b1
Description:
Between 20100503 and 20100507 the sgp.E9 instruments (EBBR, MET, SIRS, SWATS) time clocks 
were drifting outside the allowable +/-3 seconds.  During the specified period, the 
swings ranged from -326 to +637 seconds.
Measurements:sgpmetE9.b1:
  • Humidity, relative, at 2-m height, 1-min avg(rh_mean)
  • qc_temp_mean
  • qc_wdir_vec_mean
  • Wind speed vector mean(wspd_vec_mean)
  • qc_wdir_vec_std
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Barometric Pressure(atmos_pressure)
  • qc_rh_mean
  • qc_wspd_vec_mean
  • time
  • Corrected total precipitation measured by TBRG(tbrg_precip_total_corr)
  • qc_tbrg_precip_total
  • qc_vapor_pressure_mean
  • Mean Air Temperature or Hardware Error(temp_mean)
  • qc_tbrg_precip_total_corr
  • wdir_vec_std
  • vapor_pressure_mean
  • base_time
  • time_offset
  • tbrg_precip_total
  • qc_time
  • qc_wspd_arith_mean
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • qc_atmos_pressure


Back To Table of Contents

DQRID : D111114.1
Start DateStart TimeEnd DateEnd Time
11/08/2011155011/09/20110701
Subject:
SGP/MET/E9 - RH probe failure
DataStreams:sgpmetE9.b1
Description:
The T/RH probe failed. The resulting problem led to very unreasonable values of RH (~160%) 
which caused the vapor pressure values to also be incorrect.