Data Quality Reports for Session: 147899 User: vghate Completed: 02/13/2013


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D121211.3PVC/MWR/M1 - Surface air temp sensor failurepvcmwrlosM1.b1, pvcmwrtipM1.a1
D121218.2PVC/MET/M1 - Tower loweredpvcmetM1.b1
D121218.4PVC/GNDRAD/M1 - IRT failurepvcgndrad20sM1.a0, pvcgndrad60sM1.b1
D130117.4PVC/MET/M1 - Instrument problempvcmetM1.00, pvcmetM1.b1


DQRID : D121211.3
Start DateStart TimeEnd DateEnd Time
10/04/2012000012/07/20121815
Subject:
PVC/MWR/M1 - Surface air temp sensor failure
DataStreams:pvcmwrlosM1.b1, pvcmwrtipM1.a1
Description:
The surface air temperature was missing or outside the valid range some days.  The sensor 
was replaced.
Measurements:pvcmwrlosM1.b1:
  • tkair

pvcmwrtipM1.a1:
  • tkair


Back To Table of Contents

DQRID : D121218.2
Start DateStart TimeEnd DateEnd Time
10/30/2012200012/13/20121830
Subject:
PVC/MET/M1 - Tower lowered
DataStreams:pvcmetM1.b1
Description:
The tower containing the wind sensor was not at full-height of 10 meters following 
Hurricane Sandy.
Measurements:pvcmetM1.b1:
  • wind_spd_arith_max
  • wind_dir_sd
  • wind_spd_arith_min
  • Vector-averaged Wind Speed(wind_spd_vec_avg)
  • Vector-averaged Wind Direction(wind_dir_vec_avg)
  • wind_spd_arith_sd
  • Wind speed, lower, 1-min avg(wind_spd_arith_avg)


Back To Table of Contents

DQRID : D121218.4
Start DateStart TimeEnd DateEnd Time
06/26/2012000012/11/20121556
Subject:
PVC/GNDRAD/M1 - IRT failure
DataStreams:pvcgndrad20sM1.a0, pvcgndrad60sM1.b1
Description:
The IRT failed but continued producing a misleading analog signal. The ground surface 
temperature measurements were unrepresentative of the actual temperature.
Measurements:pvcgndrad60sM1.b1:
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • sfc_ir_temp_std
  • Effective Surface (Skin) Temperature(sfc_ir_temp)

pvcgndrad20sM1.a0:
  • inst_sfc_ir_signal


Back To Table of Contents

DQRID : D130117.4
Start DateStart TimeEnd DateEnd Time
10/29/2012170012/28/20120508
Subject:
PVC/MET/M1 - Instrument problem
DataStreams:pvcmetM1.00, pvcmetM1.b1
Description:
Present weather detector was occasionally reporting a hardware problem during this time. 
The reported error did not affect visibility readings, but caused all other data to report 
as missing. Error resolved its self with no indication of the problem cause.
Measurements:pvcmetM1.b1:
  • pwd_cumul_snow
  • pwd_pw_code_1_hr
  • pwd_avg_H2O_int_1_min
  • pwd_pw_code_inst
  • pwd_pw_code_15_min
  • pwd_cumul_water

pvcmetM1.00:
  • Raw data stream - documentation not supported


Back To Table of Contents



END OF DATA