Data Quality Reports for Session: 146197 User: qyj Completed: 11/23/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050614.1SGP/VCEIL/C1 - poor signalsgpvceil25kC1.b1
D060707.5SGP/VCEIL/C1 - low amplitudesgpvceil25kC1.b1
D100215.1SGP/VCEIL/C1/B4/B5/B6 - Reprocess: Incorrect serial_number and sum_backscatter fieldssgpvceil25kB4.b1, sgpvceil25kB5.b1, sgpvceil25kB6.b1, sgpvceil25kC1.b1
D100514.1SGP/VCEIL/C1 - Range normalizationsgpvceil25kC1.b1
D120524.7SGP/VCEIL/C1 - Contaminated windowsgpvceil25kC1.b1


DQRID : D050614.1
Start DateStart TimeEnd DateEnd Time
05/05/2005184204/19/20061713
Subject:
SGP/VCEIL/C1 - poor signal
DataStreams:sgpvceil25kC1.b1
Description:
When parameters were changed (set noise_h2_compensation to "ON" and units to "METERS") to 
correct a low amplitude problem, the backscatter plots began displaying horizontal 
stripes indicating detector "ringing". However, the cloud base heights are not affected. The 
problem was corrected when the instrument was replaced.
Measurements:sgpvceil25kC1.b1:
  • detection_status
  • Backscatter(backscatter)


Back To Table of Contents

DQRID : D060707.5
Start DateStart TimeEnd DateEnd Time
12/06/2004182005/05/20051841
Subject:
SGP/VCEIL/C1 - low amplitude
DataStreams:sgpvceil25kC1.b1
Description:
When the instrument was replaced with a spare, the backscatter plots began displaying a 
suspiciously low amount of amplitude (noise) but the cloud base heights were not affected. 

Discovered that when the vendor repaired this unit in August 2004, noise compensation was 
set to "OFF". Changed the parameters to "ON".

Also noted that the measurement units was set to "FEET".  This was changed to "METERS.  
The heights are not affected because the ingest recognizes the raw data units and 
automatically converts to meters.
Measurements:sgpvceil25kC1.b1:
  • Backscatter(backscatter)


Back To Table of Contents

DQRID : D100215.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000010/31/20092359
Subject:
SGP/VCEIL/C1/B4/B5/B6 - Reprocess: Incorrect serial_number and sum_backscatter fields
DataStreams:sgpvceil25kB4.b1, sgpvceil25kB5.b1, sgpvceil25kB6.b1, sgpvceil25kC1.b1
Description:
Attribute serial_number: In most cases, this field is not representative of the actual 
serial number of the instrument because the value did not change when an instrument changed 
locations or was replaced with a spare.

Variable sum_backscatter: An out-of-range condition for the "sum of detected and 
normalized backscatter" was reported as 0 instead of missing (-9999). The valid range is 0 - 
0.0999 /srad.

This DQR also applies to a1 level data collected prior to b1 level.
Measurements:sgpvceil25kC1.b1:
  • sum_backscatter

sgpvceil25kB4.b1:
  • sum_backscatter

sgpvceil25kB6.b1:
  • sum_backscatter

sgpvceil25kB5.b1:
  • sum_backscatter


Back To Table of Contents

DQRID : D100514.1
Start DateStart TimeEnd DateEnd Time
04/16/2010220204/23/20102241
Subject:
SGP/VCEIL/C1 - Range normalization
DataStreams:sgpvceil25kC1.b1
Description:
The range gate data were not normalized during this period because, when the CL31 was 
first deployed, I was uncertain about this parameter and returned it to its default setting 
of "off". Range gate normalization was enabled after receiving the following from Vaisala:

''We do recommend to keep this 'profile noise_h2' setting on. If 'profile noise_h2' is 
off, then range correction of the signal would freeze at 2400 m, unless the algorithm has 
detected a cloud region. This had been designed to make profiles in CL-VIEW look less noisy 
and to emphasize the presence of clouds.''
Measurements:sgpvceil25kC1.b1:
  • Lowest cloud base height detected.(first_cbh)
  • vertical_visibility
  • alt_highest_signal
  • Second lowest cloud base height(second_cbh)
  • Backscatter(backscatter)
  • Third cloud base height(third_cbh)


Back To Table of Contents

DQRID : D120524.7
Start DateStart TimeEnd DateEnd Time
04/17/2012151304/18/20121546
Subject:
SGP/VCEIL/C1 - Contaminated window
DataStreams:sgpvceil25kC1.b1
Description:
Alarm shown: Light Path Obstruction and Window Contamination. Window condition was 2%. 
Observed massive amounts of bird droppings on window. Cleaned window and shortly after 
window condition had risen to 94% and alarm was cleared.
Measurements:sgpvceil25kC1.b1:
  • Lowest cloud base height detected.(first_cbh)
  • vertical_visibility
  • sum_backscatter
  • alt_highest_signal
  • background_light
  • Second lowest cloud base height(second_cbh)
  • detection_status
  • Backscatter(backscatter)
  • Third cloud base height(third_cbh)


Back To Table of Contents



END OF DATA