Data Quality Reports for Session: 145900 User: perez Completed: 11/09/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D121005.1PVC/GNDRAD/M1 - Reprocess: Incorrect calibrationpvcgndrad20sM1.a0, pvcgndrad60sM1.b1


DQRID : D121005.1
Start DateStart TimeEnd DateEnd Time
06/25/2012000010/04/20122017
Subject:
PVC/GNDRAD/M1 - Reprocess: Incorrect calibration
DataStreams:pvcgndrad20sM1.a0, pvcgndrad60sM1.b1
Description:
Incorrect program used in Gndrad since PVC deployment period began.  The Gndrad program 
was corrected 10/04/2012 approx 20:17GMT.  Reprocessing will be required of the upwelling 
PSP (up_short_hemsip). This will require applying the following corrections for the time 
range specified.
Serial number:
serial number(original) = 30938
serial number(corrected) = 37297

Data:
up_short_hemip(corrected) = up_short_hemisp(original)*(113.25(new cal)/129.42(old cal))
Measurements:pvcgndrad60sM1.b1:
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Minima(up_short_hemisp_min)
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Maxima(up_short_hemisp_max)
  • Radiation, shortwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_short_hemisp)
  • up_short_hemisp_std

pvcgndrad20sM1.a0:
  • inst_up_short_hemisp


Back To Table of Contents



END OF DATA