Data Quality Reports for Session: 145418 User: yushan0427 Completed: 10/22/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D000219.1SGP/SONDE/C1 - Incorrect surface temperaturesgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D000308.1SGP/SONDE - Questionable absolute pressuressgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D000308.2SGP/SONDE - Questionable absolute pressuressgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D000625.1SGP/SONDE/C1 - Operator used wrong calibration tapesgpsondeC1.a0, sgpsondeC1.a1, sgpsondewndcalcC1.c1, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1,
sgpsondeC1.00, sgpsondewrpnC1.00
D000801.2SGP/SONDE/C1 - Incorrect absolute pressuresgpsondewndcalcC1.c1, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D001107.1SGP/SONDE/C1 - Incorrect surface temperaturesgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D011207.3SGP/SONDE/C1 - Bad temp (other?) data in 12/3/01:2328 soundingsgpsondeC1.00, sgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D011231.1SGP/SONDE/C1 - Bad temperature in CF sounding 12/22/01:0527sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D011231.2SGP/SONDE/C1 - Bad temperature data CF sounding 12/28/01:2326sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020110.1SGP/SONDE/C1 - Bad temperature in SGP/CF sounding 20020108:0528sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020524.27SGP/SONDE/C1 - CF sounding 20020522:1130 bad temperature/RHsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020526.1SGP/SONDE/C1 - Bad T/RH data in CF sounding 20020523:1129sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020611.2SGP/SONDE/C1 - CF sounding 20020609:0229 bad temp/rh/etcsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020626.34SGP/SONDE/C1 - Incorrect Surface PressuresgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020626.35SGP/SONDE/C1 - Bad Temperature SensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020703.1SGP/SONDE/C1 - Temperature sensor failuresgpqmemwrcolC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020909.1SGP/SONDE/C1 - Bad Temperature SensorsgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D020909.2SGP/SONDE/C1 - Bad Temperature SensorsgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D021006.1Bad temperature sensorsgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D021117.1SGP/SONDE/C1 - Questionable RH: CF sounding 11/13/2002:2044sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D021121.1SGP/SONDE/C1 - Contaminated by interferencesgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D021123.2SGP/SONDE/C1 - Interference CF sounding 20021120:0225sgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D021201.1SGP/SONDE/C1 - Questionable RH CF sounding 0211211:1130sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030114.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030122.1SGP/SONDE/C1 - Broken temperature sensor SGP/CF soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030206.5SGP/SONDE/C1 - Bad temperature/RHsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030330.1SGP/Sonde/C1 - Bad temperature, RHsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030409.1SGP/Sonde/C1 - Bad RH in soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030411.1SGP/Sonde/C1 - Sondes launched an hour earlysgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030411.2SGP/Sonde/C1 - Incorrect surface temperature on CF soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030411.3SGP/Sonde/C1 - Failed Sonde Launches due to Antenna problemssgplssondeC1.c1, sgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030419.2SGP/SONDE/C1 - Broken Temperature SensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030427.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030507.3SGP/SONDE/C1 - Broken temperature sensorssgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030614.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030707.7SGP/SONDE/C1 - Incorrect surface RH value.sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030722.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030807.1SGP/SONDE/C1 - A few bad temperature values at the beginning of the soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D031112.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.b1
D040127.2SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D040219.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D040219.2SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D040223.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.b1
D040301.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.b1
D040415.2SGP/SONDE/C1 - Temperature sensor broke high into the soundingsgpsondewnpnC1.b1
D041005.1SGP/SONDE/C1 - Incorrect surface temperaturesgpsondewnpnC1.b1
D041013.4SGP/SONDE/C1 - Scheduled Soundings MissedsgpsondeC1.00, sgpsondewnpnC1.b1
D050201.1SGP/SONDE/C1 - Possibly bad pressure sensor or operator data entry errorsgpsondewnpnC1.b1
D050421.5SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D050510.1SGP/SONDE/C1 - Surface pressure bad and other data noisysgpsondewnpnC1.b1
D050510.2SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D050603.4SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D050725.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D050811.5SGP/SONDE/C1 - Bad T/RH and surface P.sgpsondewnpnC1.b1
D050912.2SGP/SONDE/C1 - Temperature/RH incorrectsgplssondeC1.c1, sgpsondewnpnC1.b1
D051027.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D051121.1SGP/SONDE/C1 - Sonde RH values incorrectsgpsondewnpnC1.b1
D060208.2SGP/SONDE/C1 - Mixed use of RS92-SGP and RS92-KL radiosondessgpsondewnpnC1.b1
D060227.2SGP/SONDE/C1 - Soundings done as part of dual-sonde flightssgpsondewnpnC1.b1
D060303.1SGP/SONDE/C1 - DigiCORAIII failed, replaced with S01/S02 launchessgpsondeC1.00, sgpsondewnpnC1.b1
D060630.1SGP/SONDE/C1 - No Wind/Lat/Lon Data in Sonde FilessgpsondewnpnC1.b1
D060928.2SGP/SONDE/C1 - RH values offset due to error in ground checksgpsondewnpnC1.b1
D060928.3SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdrysgpsondewnpnC1.b1
D061201.1SGP/SONDE/C1 - RH Sensor failuresgpsondewnpnC1.b1
D080829.2SGP/SONDE/C1 - Suspect RH profile from 150-350 m above ground levelsgpsondewnpnC1.b1
D090224.3SGP/SONDE/C1 - Suspect RH valuessgpsondewnpnC1.b1
D100803.3SGP/SONDE/C1 - Sensor failuresgpsondewnpnC1.b1
D931112.1operator errorsgpsondeC1.a0, sgpsondeC1.a1
D940804.1Possible error in humidity ground checksgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D941104.1Bad surface RH value in soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D941108.2Bad surface RH value in soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D941108.4CF Sonde Ground Check CorrectionssgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D941213.1Questionable initial values sounding 941209:1133sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950109.1Questionable surface value 1/2/95 11:32sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950109.2Questionable surface value 1/3/95 11:29sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950304.1Reprocess: Sounding 950222:0530 done in research modesgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950310.1Bad surface values in sounding 3/9/95:0530sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950316.1Reprocess: Sounding 950315:1429 done in research modesgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950417.1Reprocess: Sounding 950413:1130 done in research modesgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950419.1Bad surface values in sounding 4/17/95 14:29sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D950420.1SGP/SONDE/C1 - Reprocess: Bad surface pressuresgpsondeC1.a0, sgpsondeC1.a1
D950815.1SGP/SONDE/C1 - Sonde RESEARCH mode altitudes biased lowsgpsondewrprC1.a0, sgpsondewrprC1.a1, sgpsondewrprB1.a1, sgpsondewrprB1.a0,
sgpsondewrprB4.a1, sgpsondewrprB4.a0, sgpsondewrprB5.a0, sgpsondewrprB5.a1
D950816.5bad surface tdry value in sounding 17:55sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D951006.1Apparent Interference Signal in SoundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D951006.2Apparent Interference Signal in SoundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D951006.3Apparent Interference Signal in SoundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D951006.4Apparent Interference Signal in SoundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D951006.5Apparent Interference Signal in SoundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D951006.6Apparent Interference Signal in SoundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960122.1Jump in pressure value upon launchsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960122.2Jump in pressure value upon launchsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960129.1Bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960202.2bad pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960223.1Incorrect surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960223.2Incorrect surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960229.2SGP/SONDE/C1 - incorrect factory RH calib-radiosondessgpsondewrpnC1.a1, sgpsondewrpnC1.a0
D960403.1Bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960415.1Bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960506.1Bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960602.2bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960611.3bad surface values soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960701.4Bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960706.1Bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960913.1bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960913.2bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960913.3bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960913.5bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D960927.2Bad surface pressure soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D970111.1Incorrect surface temperaturesgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D970318.2Questionable RHsgpsondewrpnC1.a1
D970507.2Jump in pressure valuesgpsondewrpnC1.a1
D970624.2Incorrect surface valuessgpsondewrpnC1.a1
D970625.1Bad sounding file CF 970622:0228sgpsondewrpnC1.a1
D970709.1Bad pressure values CF sounding 970704:0525sgpsondewrpnC1.a1
D970710.1Questionable pressure/altitude datasgpsondewrpnC1.a1
D970923.2Pressure jump at launchsgpsondewrpnC1.a1
D980126.1Incorrect radiosonde serial numberssgpsondewrpnB1.a0, sgpsondewrpnB1.a1, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1,
sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.a0, sgpsondewrpnB6.a1, sgpsondewrpnC1.a0,
sgpsondewrpnC1.a1
D980126.2Incorrect surface temperature and humiditysgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D980506.1Incorrect surface valuessgpsondewrpnC1.a1
D980507.4Incorrect surface pressuresgpsondewrpnC1.a1
D980511.2Incorrect surface pressuresgpsondewrpnC1.a1
D980716.1Bad soundingsgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D980917.1Incorrect surface readingssgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D980917.2Incorrect surface RHsgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D990124.2SGP/SONDE - Dry bias in sonde RHsgpsondewnpnB1.a1, sgpsondewnpnB4.a0, sgpsondewnpnB4.a1, sgpsondewnpnB5.a0,
sgpsondewnpnB5.a1, sgpsondewnpnB6.a0, sgpsondewnpnB6.a1, sgpsondewnpnC1.a0, sgpsondewnpnC1.a1,
sgpsondewnprC1.a0, sgpsondewnprC1.a1, sgpsondewrpnB1.00, sgpsondewrpnB1.a0,
sgpsondewrpnB1.a1, sgpsondewrpnB4.00, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1, sgpsondewrpnB5.00,
sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.00, sgpsondewrpnB6.a0,
sgpsondewrpnB6.a1, sgpsondewrpnC1.00, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrprB1.00,
sgpsondewrprB1.a0, sgpsondewrprB1.a1, sgpsondewrprB4.00, sgpsondewrprB4.a0, sgpsondewrprB4.a1,
sgpsondewrprB5.00, sgpsondewrprB5.a0, sgpsondewrprB5.a1, sgpsondewrprC1.00,
sgpsondewrprC1.a0, sgpsondewrprC1.a1, DsgpsondeB1.00, DsgpsondeB1.a0, DsgpsondeB1.a1,
DsgpsondeB4.00, DsgpsondeB4.a0, DsgpsondeB4.a1, DsgpsondeB5.00, DsgpsondeB5.a0, DsgpsondeB5.a1,
DsgpsondeC1.00, DsgpsondeC1.a0, DsgpsondeC1.a1, DsgpsondenogcptucalcB1.c1,
DsgpsondenogcptucalcB4.c1, DsgpsondenogcptucalcB5.c1, DsgpsondenogcptucalcC1.c1,
DsgpsondenogcwrpnB1.c1, DsgpsondenogcwrpnB4.c1, DsgpsondenogcwrpnB5.c1, DsgpsondenogcwrpnC1.c1,
DsgpsondeptuB1.00, DsgpsondeptuB4.00, DsgpsondeptuB5.00, DsgpsondeptuB6.00,
DsgpsondeptuC1.00, DsgpsondeptucalcB1.c1, DsgpsondeptucalcB4.c1, DsgpsondeptucalcB5.c1,
DsgpsondeptucalcC1.c1, sgpsondeB1.00, sgpsondeB1.a0, sgpsondeB1.a1, sgpsondeB4.00, sgpsondeB4.a0,
sgpsondeB4.a1, sgpsondeB5.00, sgpsondeB5.a0, sgpsondeB5.a1, sgpsondeB6.00,
sgpsondeC1.00, sgpsondeC1.a0, sgpsondeC1.a1, sgpsondeptuC1.00, sgpsondewnpnB1.a0
D990210.1SGP/SONDE - Wrong cal tapesgpsondewndcalcC1.c1, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D990303.1SGP/SONDE - Pressure jump at launchsgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D990329.1Incorrect surface RHsgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D990513.1SGP/SONDE - RH probably biased low in several soundingssgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
D991221.1SGP/SONDE - Incorrect surface temperaturesgpsondewrpnC1.00, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
D991228.1SGP/SONDE - Incorrect surface temperaturesgpsondewrpnC1.a1, sgpsondewrpnC1.a0, sgpsondewrpnC1.00


DQRID : D000219.1
Start DateStart TimeEnd DateEnd Time
02/17/2000233002/17/20002330
Subject:
SGP/SONDE/C1 - Incorrect surface temperature
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
It appears as if the operator mis-typed the temperature when entering the
surface values into the system.  The value appears as 89.0 degC instead of
8.9 degC.  Also note that there are no RH data in this sounding other than
the initial value of 100%.  The reason for this loss of RH is unknown.
Measurements:sgpsondewrpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)

sgpsondewrpnC1.a0:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D000308.1
Start DateStart TimeEnd DateEnd Time
03/03/2000232803/04/20000051
Subject:
SGP/SONDE - Questionable absolute pressures
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
The sonde surface pressure reading was considerably higher than the
corresponding THWAPS pressure (988.0 hPa vs 982.3 hPa).  The sonde
readings are consistent during the sounding, however, suggesting that
this is not a case of a pressure jump at launch but one of sensor offset.
This problem will only affect those who use the absolute pressure values.
The file altitudes, which are based on the relative pressure changes
from the surface, should be fine.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)

sgpsondewrpnC1.a0:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D000308.2
Start DateStart TimeEnd DateEnd Time
03/04/2000022903/04/20000359
Subject:
SGP/SONDE - Questionable absolute pressures
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
The sonde surface pressure reading was considerably higher than the
corresponding THWAPS pressure (992.9 hPa vs 983.0 hPa).  The sonde
readings are consistent during the sounding, however, suggesting that
this is not a case of a pressure jump at launch but one of sensor offset.
This problem will only affect those who use the absolute pressure values.
The file altitudes, which are based on the relative pressure changes
from the surface, should be fine.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)

sgpsondewrpnC1.a0:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D000625.1
Start DateStart TimeEnd DateEnd Time
06/23/2000233006/24/20000100
Subject:
SGP/SONDE/C1 - Operator used wrong calibration tape
DataStreams:sgpsondeC1.a0, sgpsondeC1.a1, sgpsondewndcalcC1.c1, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1,
sgpsondeC1.00, sgpsondewrpnC1.00
Description:
It appears as if the operators had a problem with the original sounding
and launched a second radiosonde.  Apparently they used the calibration
tape that came with the first radiosonde (serial number 943156405) in
place of the one that was correct for the second radiosonde (sn 943156406)
and all the data are bad after the first sample (surface values).
Measurements:sgpsondewndcalcC1.c1:
  • lon
  • u_wind_calc
  • alt
  • u_wind_flags
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • base_time
  • v_wind_flags
  • time_offset
  • v_wind_calc

sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • time_offset
  • Eastward Wind Component(u_wind)
  • alt
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • Wind Direction(deg)
  • base_time
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Dry Bulb Temperature(tdry)
  • wstat

sgpsondewrpnC1.a0:
  • base_time
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Dewpoint Temperature(dp)
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • time_offset
  • alt
  • Wind Direction(deg)
  • lat
  • lon

sgpsondeC1.a1:
  • Dry Bulb Temperature(tdry)
  • asc
  • Eastward Wind Component(u_wind)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lon
  • Humidity, relative(rh)
  • Wind Direction(deg)
  • base_time
  • alt
  • lat
  • Mean Wind Speed(wspd)
  • time_offset
  • Dewpoint Temperature(dp)
  • wstat
  • Northward Wind Component(v_wind)

sgpsondeC1.a0:
  • base_time
  • wstat
  • alt
  • lon
  • Dry Bulb Temperature(tdry)
  • Wind Direction(deg)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • time_offset


Back To Table of Contents

DQRID : D000801.2
Start DateStart TimeEnd DateEnd Time
07/25/2000053307/25/20000724
Subject:
SGP/SONDE/C1 - Incorrect absolute pressure
DataStreams:sgpsondewndcalcC1.c1, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
The surface pressure (983.5 hPa) reported by this radiosonde (sn 94315713)
is substantially higher than that reported by the THWAPS (~977) or by the
sondes used in the previous and following soundings (976.6, 977.3).  This
may be a calibration problem or a mechanic problem on launch.  The pressure
values reported in the remainder of the sounding are consistent with the
reported surface pressure, so the altitudes should be correct.  The
absolute pressure values may be high by about 5 hPa.
Measurements:sgpsondewndcalcC1.c1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)

sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)

sgpsondewrpnC1.a0:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D001107.1
Start DateStart TimeEnd DateEnd Time
11/03/2000203011/03/20002030
Subject:
SGP/SONDE/C1 - Incorrect surface temperature
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
The value for air temperature at the surface in this file is 23.3 degC.  This value is too 
high and resulted from incorrect data entry (typographic mistake) by the operator.  The 
true value as determined from the operator pre-launch logs is 12.3 degC.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Dry Bulb Temperature(tdry)

sgpsondewrpnC1.a0:
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D011207.3
Start DateStart TimeEnd DateEnd Time
12/03/2001232812/04/20010158
Subject:
SGP/SONDE/C1 - Bad temp (other?) data in 12/3/01:2328 sounding
DataStreams:sgpsondeC1.00, sgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It looks as though the temperature sensor was damaged on launch.  The
recorded temp goes from 16.4 at the surface to -42.6 at 2 seconds into the
flight.  The temperature never exceeds -42 though the RH and pressure look
reasonable, but probably should be considered questionable.
Measurements:sgpsondewnpnC1.00:
  • Raw data stream - documentation not supported

sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D011231.1
Start DateStart TimeEnd DateEnd Time
12/22/2001052712/22/20010659
Subject:
SGP/SONDE/C1 - Bad temperature in CF sounding 12/22/01:0527
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature data in this sounding look bad after the first value.  The
temperature series is 11.4, 2.6, -14.3, -32.4 in the first 6 seconds of
flight.  I don't know why this occurred, but it obviously is incorrect.
The pressure and RH data look reasonable.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)


Back To Table of Contents

DQRID : D011231.2
Start DateStart TimeEnd DateEnd Time
12/28/2001232612/29/20010045
Subject:
SGP/SONDE/C1 - Bad temperature data CF sounding 12/28/01:2326
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature data in this sounding are bad from approximately 16 seconds
into the flight.  The temperature series is 9.9, 10.8, 11.3, 1.5, 11.6, 11.6,
11.6, -32.2 and remains below -30 degC.  I don't know why this occurred, but
it clearly is incorrect.  The pressure data looks OK as does the RH, though
the RH data are missing (probably sensor failure) above roughly 3.5 km.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)


Back To Table of Contents

DQRID : D020110.1
Start DateStart TimeEnd DateEnd Time
01/08/2002052801/08/20020714
Subject:
SGP/SONDE/C1 - Bad temperature in SGP/CF sounding 20020108:0528
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
Temperature values in this sounding went from 3.5 degC at the surface to
-33.3 degC at the next sample.  It appears that all the remaining
temperature values have an approximate -35 degC offset.  The pressure
and RH values appear reasonable.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)


Back To Table of Contents

DQRID : D020524.27
Start DateStart TimeEnd DateEnd Time
05/22/2002113005/22/20021347
Subject:
SGP/SONDE/C1 - CF sounding 20020522:1130 bad temperature/RH
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the sonde sensor boom was damaged upon launch.  The result
is that no RH data are reported and the reported temperature is something on
the order of 60 degC too low.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • asc

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • alt
  • Humidity, relative(rh)
  • asc


Back To Table of Contents

DQRID : D020526.1
Start DateStart TimeEnd DateEnd Time
05/23/2002112905/23/20021322
Subject:
SGP/SONDE/C1 - Bad T/RH data in CF sounding 20020523:1129
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the sensor boom was damaged shortly after launch.  The
temperature reading jumps -60 degC and the RH goes to 0.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • asc

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • alt
  • Humidity, relative(rh)
  • asc


Back To Table of Contents

DQRID : D020611.2
Start DateStart TimeEnd DateEnd Time
06/09/2002022906/09/20020236
Subject:
SGP/SONDE/C1 - CF sounding 20020609:0229 bad temp/rh/etc
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature and RH for this sounding look bad, either because of
interference from another sonde or because the temperature sensor was
broken on launch.  The sounding terminated early in any event.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • asc

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • alt
  • Humidity, relative(rh)
  • asc


Back To Table of Contents

DQRID : D020626.34
Start DateStart TimeEnd DateEnd Time
06/17/2002112806/17/20021313
Subject:
SGP/SONDE/C1 - Incorrect Surface Pressure
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the operator made a typographical error when entering the
surface pressure.  The file has 987.0 hPa and it probably should be 978.0
which would be consistent with the first sample provided by the radiosonde
(977.3 hPa), the surface pressures recorded for the adjacent soundings, and
the THWAPS pressure.

Because the sounding altitude is calculated assuming the surface pressure
is correct, the altitude values for the entire flight and the ascent rate 
values for the first 30 seconds of the sounding will be incorrect.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • asc

sgpsondewnpnC1.a1:
  • alt
  • asc


Back To Table of Contents

DQRID : D020626.35
Start DateStart TimeEnd DateEnd Time
06/19/2002232906/20/20020036
Subject:
SGP/SONDE/C1 - Bad Temperature Sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the temperature sensor broke shortly after launch.  As a
result, the temperature and dewpoint values are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D020703.1
Start DateStart TimeEnd DateEnd Time
06/27/2002172806/27/20021908
Subject:
SGP/SONDE/C1 - Temperature sensor failure
DataStreams:sgpqmemwrcolC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
Temperature sensor broke at launch.  All temperature-related variables
are incorrect.
Measurements:sgpqmemwrcolC1.c1:
  • Water vapor, total integrated from radiosonde(integ_vap_sonde)
  • integ_vap_sonde_direct

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D020909.1
Start DateStart TimeEnd DateEnd Time
09/06/2002172709/06/20021854
Subject:
SGP/SONDE/C1 - Bad Temperature Sensor
DataStreams:sgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the temperature sensor broke upon launch and therefore the reported 
temperature is approximately 40 degC too low.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)

sgpqmemwrcolC1.c1:
  • Water vapor, total integrated from radiosonde(integ_vap_sonde)

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D020909.2
Start DateStart TimeEnd DateEnd Time
09/06/2002052709/06/20020718
Subject:
SGP/SONDE/C1 - Bad Temperature Sensor
DataStreams:sgpqmemwrcolC1.c1, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the temperature sensor broke shortly after launch. Temperatures are offset 
by approxmiately (but not constantly) 40 degC.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)

sgpqmemwrcolC1.c1:
  • Water vapor, total integrated from radiosonde(integ_vap_sonde)

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D021006.1
Start DateStart TimeEnd DateEnd Time
10/03/2002112010/03/20021320
Subject:
Bad temperature sensor
DataStreams:sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the temperture sensor broke a few seconds into flight.  This results in an 
unreasonably low temperature for the rest of the flight.  For some reason, the rh values 
also go missing shortly after launch.  Only the wind and pressure data are reliable.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)
  • alt

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • asc
  • alt
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • asc
  • Dry Bulb Temperature(tdry)
  • alt


Back To Table of Contents

DQRID : D021117.1
Start DateStart TimeEnd DateEnd Time
11/13/2002204411/13/20022205
Subject:
SGP/SONDE/C1 - Questionable RH: CF sounding 11/13/2002:2044
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The RH data in this sounding is erratic between 2km and 10 km, oscillating between 
reasonable values (~40%RH) and zero.  I certainly doubt that this is a real, heretofore 
unreported, atmospheric phenomenon so I have to conclude that something is probably wrong with 
the sensor.  I have not seen this behavior before.  One would have to look at the 
absolutely raw RH data to explore further.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D021121.1
Start DateStart TimeEnd DateEnd Time
11/19/2002142311/19/20021623
11/19/2002172611/19/20021917
11/19/2002202611/19/20022204
Subject:
SGP/SONDE/C1 - Contaminated by interference
DataStreams:sgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
These three soundings are contaminated by interference from another radiosonde.  It is not 
clear why; this doesn't usually happen at the CF where the operators are very 
experienced and frequency separation is not usually a problem.
Measurements:sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Eastward Wind Component(u_wind)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • time_offset
  • lat
  • alt
  • wstat
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • lon
  • Dewpoint Temperature(dp)
  • Wind Direction(deg)
  • wstat
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • Northward Wind Component(v_wind)
  • alt
  • lat
  • Eastward Wind Component(u_wind)
  • base_time
  • time_offset
  • Dry Bulb Temperature(tdry)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D021123.2
Start DateStart TimeEnd DateEnd Time
11/20/2002022511/20/20020412
Subject:
SGP/SONDE/C1 - Interference CF sounding 20021120:0225
DataStreams:sgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
Like several soundings on 11/19, this sounding was affected by interference from another 
radiosonde.
Measurements:sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Eastward Wind Component(u_wind)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • time_offset
  • lat
  • alt
  • wstat
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • lon
  • Dewpoint Temperature(dp)
  • Wind Direction(deg)
  • wstat
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • Northward Wind Component(v_wind)
  • alt
  • lat
  • Eastward Wind Component(u_wind)
  • base_time
  • time_offset
  • Dry Bulb Temperature(tdry)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D021201.1
Start DateStart TimeEnd DateEnd Time
11/21/2002113011/21/20021311
Subject:
SGP/SONDE/C1 - Questionable RH CF sounding 0211211:1130
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The RH samples in this sounding oscillate between reasonable values (60-80%) and zero.  
This may be a problem with the RH sensor or the software that alternates between the heated 
and non-heated RH elements.  In either case, the reported values are questionable.  More 
investigation of the raw binary data would be required to diagnose further.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030114.1
Start DateStart TimeEnd DateEnd Time
01/11/2003053601/11/20030551
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The RH values during the first 15 minutes of this sounding oscillate between reasonable 
values and near-zero values.  The oscillation is irregular and seems to be related to 
failure of the RH sensor heating process.  I have informed Vaisala of the problem and provided 
raw data files to them for analysis.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030122.1
Start DateStart TimeEnd DateEnd Time
01/19/2003113401/19/20031259
Subject:
SGP/SONDE/C1 - Broken temperature sensor SGP/CF sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The radiosonde temperature sensor apparently broke during launch.  This results in bad 
temperature, dew point, and rh data.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030206.5
Start DateStart TimeEnd DateEnd Time
02/02/2003173202/02/20031832
Subject:
SGP/SONDE/C1 - Bad temperature/RH
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke shortly after launch.  All temperature and RH-related data 
are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030330.1
Start DateStart TimeEnd DateEnd Time
03/20/2003173103/20/20031904
03/20/2003113103/20/20031140
03/18/2003113203/18/20031322
Subject:
SGP/Sonde/C1 - Bad temperature, RH
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
These three soundings all show the effects of a temperature sensor broken at launch.  The 
temperature, RH, dew-point values all are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030409.1
Start DateStart TimeEnd DateEnd Time
04/06/2003114404/06/20031203
Subject:
SGP/Sonde/C1 - Bad RH in sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The RH sensor heating circuit was out of synch from about 400 sec after launch until the 
circuit was turned off whent he sounding temperature reached approximately 233 degK (-40 
degC) about 1500 sec after launch.  During this time period the reported RH oscillates 
between reasonable values and near-zero values.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030411.1
Start DateStart TimeEnd DateEnd Time
04/06/2003220004/07/20030700
Subject:
SGP/Sonde/C1 - Sondes launched an hour early
DataStreams:sgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It looks like someone forgot to set his/her clock ahead.  The sounding that should have 
been done at 23:30 UTC on 4/6 was done at 22:38 and the following sounding, which should 
have been done at 0530 on 4/7 was done at 04:31.  The subsequent soundings all are done at 
the correct times.
Measurements:sgpsondewnpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Eastward Wind Component(u_wind)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • time_offset
  • lat
  • alt
  • wstat
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • lon
  • Dewpoint Temperature(dp)
  • Wind Direction(deg)
  • wstat
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • Northward Wind Component(v_wind)
  • alt
  • lat
  • Eastward Wind Component(u_wind)
  • base_time
  • time_offset
  • Dry Bulb Temperature(tdry)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D030411.2
Start DateStart TimeEnd DateEnd Time
04/06/2003223804/06/20032238
Subject:
SGP/Sonde/C1 - Incorrect surface temperature on CF sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the operator entered an incorrect value for surface temperature.  Rather 
than 43.2 degC in the file, the value is most likely 19. degC (thwaps reading 19.4, first 
sonde reading aloft 18.6).
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D030411.3
Start DateStart TimeEnd DateEnd Time
04/01/2003173004/01/20031930
04/02/2003053004/02/20030730
04/02/2003113004/02/20031330
Subject:
SGP/Sonde/C1 - Failed Sonde Launches due to Antenna problems
DataStreams:sgplssondeC1.c1, sgpsondeC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
These sonde launches where unsuccessful due to problems
with the antenna configuration resulting in signal loss
before the launch.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • lat
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Dry Bulb Temperature(tdry)
  • alt
  • time_offset
  • lon
  • base_time

sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Eastward Wind Component(u_wind)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • time_offset
  • lat
  • alt
  • wstat
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • lon
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • wstat
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • Northward Wind Component(v_wind)
  • alt
  • lat
  • base_time
  • Eastward Wind Component(u_wind)
  • time_offset
  • Dry Bulb Temperature(tdry)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D030419.2
Start DateStart TimeEnd DateEnd Time
04/15/2003233204/16/20030124
Subject:
SGP/SONDE/C1 - Broken Temperature Sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke shortly after launch as a result all variables that are 
affected by temperature are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030427.1
Start DateStart TimeEnd DateEnd Time
04/18/2003113004/18/20031310
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor on this radiosonde broke after launch.  All temperature-related 
variables (dp, tdry, rh) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030507.3
Start DateStart TimeEnd DateEnd Time
05/04/2003113005/04/20031145
05/04/2003233005/05/20030116
Subject:
SGP/SONDE/C1 - Broken temperature sensors
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensors broke at launch on both of these soundings.  All of the 
temperature-related data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030614.1
Start DateStart TimeEnd DateEnd Time
06/09/2003173006/09/20031737
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030707.7
Start DateStart TimeEnd DateEnd Time
06/22/2003233106/22/20032331
Subject:
SGP/SONDE/C1 - Incorrect surface RH value.
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The surface RH value, reported as 0%RH should be 52%.  This resulted from a typographical 
error by the operator when entering the surface data.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030722.1
Start DateStart TimeEnd DateEnd Time
07/19/2003173007/19/20031930
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D030807.1
Start DateStart TimeEnd DateEnd Time
08/02/2003172508/02/20031726
Subject:
SGP/SONDE/C1 - A few bad temperature values at the beginning of the sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
I've never seen this before.  The temperature reported by the radiosonde dropped over 30 
degC just after launch (usually a symptom of a broken temperature sensor), but then 
recovered after 14 seconds of bad readings.  The temperatures from 2 seconds through 14 seconds 
after launch are incorrect, the remainder of the sounding looks fine.  I have sent the 
data files to Vaisala for their consideration.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)

sgpsondewnpnC1.a1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)


Back To Table of Contents

DQRID : D031112.1
Start DateStart TimeEnd DateEnd Time
11/01/2003113311/01/20031315
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D040127.2
Start DateStart TimeEnd DateEnd Time
01/16/2004201501/16/20042151
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values during the first half of this sounding oscillate between reasonable values 
and near-zero values.  The oscillation is irregular and seems to be related to failure of 
the RH sensor heating process.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D040219.1
Start DateStart TimeEnd DateEnd Time
02/09/2004053002/09/20040601
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values during the first part of this sounding oscillate between reasonable values 
and near-zero values.  The oscillation seems to be related to failure of the RH sensor 
heating process.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D040219.2
Start DateStart TimeEnd DateEnd Time
02/02/2004053002/02/20040826
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently transposed to digits when entering the surface 
pressure value.  The value entered is 987.0 hPa but the value shown in the raw data file at 
launch is 978.0.  As a result, the absolute altitudes in this sounding will be slightly 
incorrect as will be the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • asc


Back To Table of Contents

DQRID : D040223.1
Start DateStart TimeEnd DateEnd Time
02/19/2004174602/19/20041946
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D040301.1
Start DateStart TimeEnd DateEnd Time
02/27/2004053102/27/20040721
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor broke shortly after launch on this sounding.  All of the 
temperature-related data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D040415.2
Start DateStart TimeEnd DateEnd Time
04/13/2004122904/13/20041301
Subject:
SGP/SONDE/C1 - Temperature sensor broke high into the sounding
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor on this radiosonde appeared to break 56 minutes and 22 seconds into 
the sounding at an altitude of 16570 m.  All the data below this point are good; only 
the data above this point to the end of the sounding (88 minutes and 14 seconds) are bad.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D041005.1
Start DateStart TimeEnd DateEnd Time
10/02/2004113010/02/20041131
Subject:
SGP/SONDE/C1 - Incorrect surface temperature
DataStreams:sgpsondewnpnC1.b1
Description:
The operator entered a the surface temperature incorrectly on this sounding.  The sonde 
data file shows the temperature as 33.5 degC but the operations log shows it as 3.5 degC.  
The first temperature recorded by the sonde after launch is 3.7 degC, consistent with the 
typical early morning inversion.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D041013.4
Start DateStart TimeEnd DateEnd Time
01/16/2004233001/17/20041830
01/18/2004053001/18/20040630
01/21/2004053001/21/20040630
Subject:
SGP/SONDE/C1 - Scheduled Soundings Missed
DataStreams:sgpsondeC1.00, sgpsondewnpnC1.b1
Description:
The following scheduled sonde launches were missed due to computer 
system failures:

20040116.2330
20040117.0530
20040117.1130
20040117.1730
20040118.0530
20040121.0530
Measurements:sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • lat
  • time_offset
  • alt
  • wstat
  • Humidity, relative(rh)
  • Eastward Wind Component(u_wind)


Back To Table of Contents

DQRID : D050201.1
Start DateStart TimeEnd DateEnd Time
01/19/2005053101/19/20050706
Subject:
SGP/SONDE/C1 - Possibly bad pressure sensor or operator data entry error
DataStreams:sgpsondewnpnC1.b1
Description:
There is a discrepency between the surface pressure and temperature data entered by the 
operator and that recorded by the THWAPS.  Review of the raw data from the radiosonde shows 
that the pressure was periodically varying by as much as 12 hPa (~988 to 1000)in the 
time period before launch.  The operator entry of 998.2 is at the high end of this range - 
the concurrent THWAPS reading was about 988.4 at the low end.  The operator entered 
temperature 6.2 degC is considerably higher than the THWAPS value of 1.8.  The pre-flight log 
entry for this sounding is missing from the OMIS database.  If not for the extremely 
unstable pressure reading I would have assumed this was an operator error.  It will take some 
more research to figure out what is going on.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • lat
  • time_offset
  • alt
  • wstat
  • Humidity, relative(rh)
  • Eastward Wind Component(u_wind)


Back To Table of Contents

DQRID : D050421.5
Start DateStart TimeEnd DateEnd Time
04/11/2005174904/11/20051920
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently entered an incorrect surface pressure value.  The 
value entered is 988.8 hPa but the value shown in the raw data file at launch is 968.8.  As a 
result, the absolute altitudes in this sounding will be slightly incorrect as will be 
the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • asc


Back To Table of Contents

DQRID : D050510.1
Start DateStart TimeEnd DateEnd Time
04/26/2005172604/26/20051910
Subject:
SGP/SONDE/C1 - Surface pressure bad and other data noisy
DataStreams:sgpsondewnpnC1.b1
Description:
I was checking this sounding because the surface pressure entered by the operator was 
considerably higher than that recorded by the TWHAPS and SMOS.  I'm not sure why, but the 
pressure data are very noisy while the sonde is on the ground (which accounts for the 
incorrect surface pressure) and the RH data aloft do not look terrible but do not look great 
either.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • lat
  • time_offset
  • alt
  • wstat
  • Humidity, relative(rh)
  • Eastward Wind Component(u_wind)


Back To Table of Contents

DQRID : D050510.2
Start DateStart TimeEnd DateEnd Time
04/29/2005232904/30/20050111
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently typed an 89 instead of a 78 when entering the surface 
pressure value.  The value entered is 989.9 hPa but the value shown in the raw data file 
at launch is 978.9.  As a result, the absolute altitudes in this sounding will be 
slightly incorrect as will be the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • asc


Back To Table of Contents

DQRID : D050603.4
Start DateStart TimeEnd DateEnd Time
05/11/2005053005/11/20050750
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently mistyped a digit when entering the surface pressure 
value.  The value entered is 975.6 hPa but the value shown in the raw data file at launch 
is 972.6.  As a result, the absolute altitudes in this sounding will be slightly incorrect 
as will be the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • asc


Back To Table of Contents

DQRID : D050725.1
Start DateStart TimeEnd DateEnd Time
07/17/2005234707/18/20050141
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values below 6 km are incorrect.  The problem relates to a failure of the GC25 
ground check set used before this particular sounding.  The failure seems to have affected 
the sensor calibration with the effect that one of the two sensors was reading artificially 
high.  Because the internal processing software uses the highest of the two sensor 
readings, the bad sensor value is chosen whenever it is not heated.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D050811.5
Start DateStart TimeEnd DateEnd Time
08/01/2005113208/01/20050116
Subject:
SGP/SONDE/C1 - Bad T/RH and surface P.
DataStreams:sgpsondewnpnC1.b1
Description:
Apparently multiple failures.  The radiosonde temperature sensor broke on launch causing 
an approximate 35 degC negative offset and as a result, the RH is incorrect.  Furthermore, 
it appears that the pressure sensor was off by approximately 4 hPa, though this would 
not affect the altitude calculation, the absolute pressure is wrong.
Measurements:sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D050912.2
Start DateStart TimeEnd DateEnd Time
09/09/2005113209/09/20051332
Subject:
SGP/SONDE/C1 - Temperature/RH incorrect
DataStreams:sgplssondeC1.c1, sgpsondewnpnC1.b1
Description:
The temperature throughout this sounding is too high and as a result the RH values will be 
incorrect as well.  I'm not sure what is wrong here but the operators noted reasonable 
values (18.1 degC, 87%) in the log before launch.  Review of the raw data, however, shows 
the sonde reporting temperatures nearly 20 degC higher.  I suppose it is possible that 
the operator entered into the log the reference temperature from the GC25 ground check set 
rather than the temperature reported by the sonde - I can't think of any other 
explanation - there is no doubt that the temperature sensor on this sonde was bad.
Measurements:sgplssondeC1.c1:
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)

sgpsondewnpnC1.b1:
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D051027.1
Start DateStart TimeEnd DateEnd Time
10/24/2005114010/24/20051204
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values during this sounding oscillate between reasonable values and near-zero 
values.  The oscillation is due to failure of the RH sensor heating process.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D051121.1
Start DateStart TimeEnd DateEnd Time
04/13/2005234604/15/20051732
Subject:
SGP/SONDE/C1 - Sonde RH values incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
RH values for all sondes launched during this time were incorrect due to a faulty Ground 
Check set which damaged or conditioned the RH sensor improperly.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D060208.2
Start DateStart TimeEnd DateEnd Time
02/10/2006000012/31/20062359
Subject:
SGP/SONDE/C1 - Mixed use of RS92-SGP and RS92-KL radiosondes
DataStreams:sgpsondewnpnC1.b1
Description:
Because of a manufacturer's production problem, we will be using both RS92-SGP (GPS 
windfinding and RS92-KL (Loran windfinding) radiosondes at the SGP/CF starting February 10, 
2006.  The radiosonde type used for the each sounding may be determined by looking the 
metadata variable "launch_status" in the netCDF data files.
Measurements:sgpsondewnpnC1.b1:
  • wstat
  • lon
  • Mean Wind Speed(wspd)
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • lat
  • Eastward Wind Component(u_wind)


Back To Table of Contents

DQRID : D060227.2
Start DateStart TimeEnd DateEnd Time
02/22/2006000002/27/20060000
Subject:
SGP/SONDE/C1 - Soundings done as part of dual-sonde flights
DataStreams:sgpsondewnpnC1.b1
Description:
The following soundings done during the subject time period were flown in dual-sonde mode 
in which the standard ARM RS92 radiosonde was attached to the same balloon with a NASA 
ATR (atmospheric temperature reference) radiosonde.  The radiosondes were separated by a 6' 
styrofoam bar.  To accommodate the additional weight, we used 1200g balloons rather than 
350g balloons.  Accordingly, we want to alert users that these soundings may reach 
higher altitudes than normal for ARM soundings and that the ascent rate may be somewhat 
higher.  The following soundings are affected:

Sequence  Date    UTC launch time
    1     2/22        0530
    2     2/22        1730
    3     2/22        2330 <---- No data: launch failure    
    4     2/23        0230
    5     2/23        0530
    6     2/23        1730    
    7     2/23        2030
    8     2/23        2330
    9     2/24        2330
   10     2/25        0215
   11     2/25        0509    
   12     2/25        1730
   13     2/25        1930
   14     2/25        2300
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • lat
  • time_offset
  • alt
  • wstat
  • Humidity, relative(rh)
  • Eastward Wind Component(u_wind)


Back To Table of Contents

DQRID : D060303.1
Start DateStart TimeEnd DateEnd Time
01/17/2004233101/18/20040108
01/18/2004113801/18/20041252
01/18/2004172901/18/20041852
01/18/2004233901/19/20040111
01/19/2004053101/19/20040711
01/19/2004113601/19/20041316
01/19/2004233101/20/20040101
01/19/2004172301/19/20041752
01/20/2004053101/20/20040703
01/20/2004113201/20/20041332
01/20/2004172801/20/20041928
01/20/2004233001/21/20040130
01/21/2004173101/21/20041931
Subject:
SGP/SONDE/C1 - DigiCORAIII failed, replaced with S01/S02 launches
DataStreams:sgpsondeC1.00, sgpsondewnpnC1.b1
Description:
The digiCORA-III failed on Saturday 2004-01-17.  The operators reported that they were 
unable to load the software and conduct normal soundings.	Following procedure, they 
conducted the regular soundings by using the S01/S02 systems as allowed by the AIRS IOP schedule.
The netCDF header fields "input_source" and "facility_id" will mention which of the 
S01/S02 systems was used in these launches.
Measurements:sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewnpnC1.b1:
  • alt
  • lon
  • lat


Back To Table of Contents

DQRID : D060630.1
Start DateStart TimeEnd DateEnd Time
06/17/2006000006/21/20062359
Subject:
SGP/SONDE/C1 - No Wind/Lat/Lon Data in Sonde Files
DataStreams:sgpsondewnpnC1.b1
Description:
The wind finding hardware failed so that no wind or latitude/longitude data was collected 
on the launches for these days.
Measurements:sgpsondewnpnC1.b1:
  • wstat
  • lon
  • Mean Wind Speed(wspd)
  • Northward Wind Component(v_wind)
  • lat
  • Eastward Wind Component(u_wind)


Back To Table of Contents

DQRID : D060928.2
Start DateStart TimeEnd DateEnd Time
08/27/2006233209/25/20061600
Subject:
SGP/SONDE/C1 - RH values offset due to error in ground check
DataStreams:sgpsondewnpnC1.b1
Description:
Background: After installation of the latest software update , we began performing formal 
ground checks on RS92 radiosondes.  By comparing the
radiosonde readings with reference values in a controlled environment, the
ground check is intended to ensure that the radiosonde sensors are in
calibration before launch.  The radisonde values during the ground check
process are recorded automatically; the reference values are entered by the
operator.  If the radiosonde readings vary from the reference values, the
system 'corrects' the radiosonde values.  In the case of RH, the correction
is applied as an offset (true RH = indicated RH + correction).

Problem: Some operators misunderstood the ground-check procedure and entered the 
radiosonde values of RH rather than the reference value (assumed 0%RH), thus, some soundings done 
during this period have RH values that are different from what they would be if the 
ground check procedure had been done correctly.

Consequence:  Because the RH corrections generally are small (averaging
about 0.5% RH) and the precision of the reported RH data during this time
period is 1% RH, some values will not be affected at all; others will be off by about 1% 
RH (still within the stated accuracy of the sensor). 
Furthermore, because entering the radiosonde value as the reference value
results in a near zero 'correction,' one may view these soundings as being
done without the ground check correction.  Also note that the dew point
value will be suspect as well.

I am attaching below a listing of the soundings that were affected during the indicated 
time period.  Users can see the magnitude of the problem and choose whether or not to apply 
an offset in RH.  Note that application of the offset to the processed RH data (in the 
netCDF file) will not have the same effect of applying the correction to the absolutely 
raw data (before processing), but the differences should be insignificant.  Also note that 
the corrections for each sounding are included in the netCDF header information.  These 
attributes are named 'humidity_correction' and 'humidity_correction_2'.  The values of RH 
indicated by the radiosonde while it is in the ground check set are in attributes 
'humidity_gc_sonde' and 'humidity_gc_sonde_2.'  There is an RH reading for each of the two RH 
sensors used in the RS92 radiosonde.

Here is the list - RH1 and RH2 are the radiosonde readings in the ground
check set.  Ref is the reference value entered by the operator.  The
correcte reference value should be 0%.  To obtain an approximation to the RH value that 
would have been recorded if the ground check had been done
properly, subtract the Ref value from the indicated RH.

 YYYYMMDD  HHMM  SerialN      RH1     RH2     Ref
 20060827  2332  B2624322    1.00    1.00    1.00
 20060828  1731  B2634078    1.00    1.00    1.00
 20060828  2332  B2624380    3.00    3.00    2.00
 20060909  2331  B2615266    1.00    1.00    1.00
 20060915  1759  B2914012    1.00    1.00    1.00
 20060919  2350  B2825128    1.00    1.00    1.00
 20060920  1800  B2825088    1.00    1.00    1.00
 20060920  2346  B2815633    1.00    1.00    1.00
 20060921  1728  B2834732    1.30    1.30    1.30
 20060921  2330  B2825042    1.50    1.50    1.50
 20060922  0527  B2825043    1.70    1.80    1.70
 20060922  1128  B2825031    1.60    1.50    1.60
 20060922  1729  B2834437    1.50    1.50    1.50
 20060922  2330  B2825040    0.40    0.50    0.50
 20060923  0529  B2834733    0.30    0.30    0.30
 20060923  1128  B2825026    0.40    0.40    0.40
 20060923  1729  B2825064    0.60    0.70    0.60
 20060923  2330  B2825041    0.40    0.50    0.50
 20060924  0529  B2825039    0.30    0.30    0.30
 20060924  1729  B2825025    0.20    0.30    0.20
 20060924  2329  B2825032    0.30    0.40    0.40
 20060925  0529  B2824234    0.20    0.30    0.20
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D060928.3
Start DateStart TimeEnd DateEnd Time
09/28/2006172812/31/99992359
Subject:
SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry
DataStreams:sgpsondewnpnC1.b1
Description:
The output precision of the following variables was increased 20060928

alt  changed from 1m to 0.1m
dp   changed from 0.1degC to 0.01degC
pres changed from 0.1 hPa to 0.01 hPa
RH   changed from 1%RH to 0.01%RH
tdry changed from .1degC to 0.01degC

Note that the increase in precision does not necessarily imply an increase in accuracy.  
Users are cautioned to continue to use their best scientific judgement when using these or 
any other data.
Measurements:sgpsondewnpnC1.b1:
  • alt
  • Dry Bulb Temperature(tdry)
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D061201.1
Start DateStart TimeEnd DateEnd Time
11/27/2006233111/28/20060056
Subject:
SGP/SONDE/C1 - RH Sensor failure
DataStreams:sgpsondewnpnC1.b1
Description:
The differences between the two RH sensors on this sonde are unreasonably high (~20%).  As 
a result the reported RH values oscillate by this amount during the times the sensors 
are alternately heated.  After the heating stops, the reported RH comes from the sensor 
reading the higher value.  There is no way of knowing if this is the correct value.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D080829.2
Start DateStart TimeEnd DateEnd Time
09/14/2006113109/14/20061431
08/06/2006110008/06/20061800
08/12/2006110008/12/20062359
08/13/2006230008/13/20062359
08/14/2006110008/14/20061200
08/16/2006110008/16/20061200
08/25/2006113608/25/20061436
08/26/2006113408/26/20061434
08/28/2006053308/28/20060833
09/02/2006113509/02/20061435
09/02/2006173409/02/20062034
09/03/2006053409/03/20060834
09/03/2006113009/03/20061430
09/03/2006173009/03/20062030
09/04/2006113409/04/20061434
09/04/2006173109/04/20062031
09/05/2006113109/05/20061431
09/11/2006053209/11/20060832
09/12/2006113109/12/20061431
09/13/2006113109/13/20061431
Subject:
SGP/SONDE/C1 - Suspect RH profile from 150-350 m above ground level
DataStreams:sgpsondewnpnC1.b1
Description:
Several radiosondes were noticed to have a very stark dry layer between 150 m and 350 m, 
where the RH dropped from approximately 60-80% (which I would take as close to the ambient 
conditions) to less than 2%.  The character of these dropouts look like instrument 
issues, as it only a handful of radiosondes that appear to be affected.  The quicklook images 
from the Raman lidar does not show any very dry layers, thus supporting the hypothesis 
that the RH measurements from these radiosondes (at least in this small ~200 m level) are 
in error.  I should note that the temperature profiles look normal.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D090224.3
Start DateStart TimeEnd DateEnd Time
01/06/2009173001/06/20091730
Subject:
SGP/SONDE/C1 - Suspect RH values
DataStreams:sgpsondewnpnC1.b1
Description:
RH values only are suspect for the duration of this radiosonde flight, exhibiting a 
"sawtooth" pattern.
Measurements:sgpsondewnpnC1.b1:
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D100803.3
Start DateStart TimeEnd DateEnd Time
06/12/2002053306/12/20020533
Subject:
SGP/SONDE/C1 - Sensor failure
DataStreams:sgpsondewnpnC1.b1
Description:
Temperature sensor failure on sonde.  Data is incorrect, do not use.
Measurements:sgpsondewnpnC1.b1:
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • lon
  • Mean Wind Speed(wspd)
  • base_time
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Wind Direction(deg)
  • Northward Wind Component(v_wind)
  • lat
  • time_offset
  • alt
  • wstat
  • Humidity, relative(rh)
  • Eastward Wind Component(u_wind)


Back To Table of Contents

DQRID : D931112.1
Start DateStart TimeEnd DateEnd Time
11/11/1993192711/12/19932359
Subject:
operator error
DataStreams:sgpsondeC1.a0, sgpsondeC1.a1
Description:
DQR No:                               Platform: SGPSONDEC1

Subject: operator error

Date Submitted: 11/12/93
Submitted By: Barry Lesht             _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at problems@arm.gov.

Platform/Measurement:  All
        What level data: (raw,a0,a1,b1,c1 etc): 

    What location was the data collected at: SGP/CF
         
    Period of time in question
        Begin Date  11/11/93   Time   19:27    (GMT)
        End Date      /  /     Time     :      (GMT)
   Sonde data files 11/11/93 19:27 and following may have bad data.

 Data should be labeled:
 _X_  questionable                      ___  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:
 
 Mike Splitt of the site scientist team noted that the sounding done 11/11/93
 showed 0 RH at the ground.  I looked at the raw data file and also noted that
 the ground check humidity values were entered as 70 (reference) and 69 (sonde).
 The ground check humidity values should be zero.  This suggests an operator
 error of some sort.  Because 11/11 was a holiday, the usual sonde operator
 was not on site.  No entries of anything unusual were found in the daily
 ops log.  It may be coincidental that the SDS change-over moving Dorothy
 from the SPARC 2 to the SPARC 10 occurred at this time, but it may not be.

 The sounding done 11/12/93 also had problems.  Dave Glahn reported that the
 first sonde he tried showed 44% RH in the ground check set.  This typically
 results from using an incorrect calibration tape.  Dave opened a second
 sonde which passed ground check.  After launch, when Dave attempted to enter
 the surface observations, he says they were not written to the normal output
 file and that he was unable to graph the sounding on the sonde PC
 as it was occurring.  The operators played with the computer and ended up
 overwriting the standard output file - losing all data below about 5 km.

 It is difficult to determine the cause of the problem.  These data files
 should be flagged as questionable until we understand what happened.  My
 hypothesis is that the operators inadvertently modified the sonde software
 on 11/11 and that the output files are being written to the wrong directories.
 It is also possible that this problem resulted from the SDS change-over.
 SDS change-overs have, in the past, caused problems with the sonde data
 archiving.  I gave instructions to Dave Glahn to check the directory pointers
 before doing a sounding on Monday.  I will be on site Wednesday (for another
 purpose) and will check the system if we do not have resolution by then.
 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.


Data Processing Notes                Date
Measurements:sgpsondeC1.a1:
  • Dry Bulb Temperature(tdry)
  • asc
  • Eastward Wind Component(u_wind)
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • Mean Wind Speed(wspd)
  • lon
  • time_offset
  • Dewpoint Temperature(dp)
  • wstat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • Wind Direction(deg)

sgpsondeC1.a0:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • base_time
  • lat
  • wstat
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • alt
  • time_offset
  • lon
  • Dry Bulb Temperature(tdry)
  • Wind Direction(deg)


Back To Table of Contents

DQRID : D940804.1
Start DateStart TimeEnd DateEnd Time
07/13/1994113108/03/19941430
Subject:
Possible error in humidity ground check
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  sgpsondewrpnC1

Subject:   Possible error in humidity ground check

Date Submitted:  8/3/94
Submitted By:    Barry Lesht          _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
	What level data: (raw,a0,a1,b1,c1 etc): raw, a0, a1

    What location was the data collected at: CF
 
    Period of time in question
 	Begin Date   7/13/94   Time   11:31    (GMT)
 	End Date     8/ 3/94   Time   14:30    (GMT)

 Data should be labeled:
 _X_  questionable                      ___  All data fields affected
 ___  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

We suspect that the dessicant in the bbss ground check set (located 
only at the central facility) has become saturated and is no longer
providing a 0 %RH environment against which to check the sonde RH sensor.
This would result in a bias in the correction for humidity for 
those soundings that were done during the time the dessicant was bad.  
Examination of the data suggests that the potential errors are small, 
(on the order of a few percent RH), but sufficiently different from previous 
corrections to warrant temporary suspension of the ground check procedure.

A review of the data collected since the beginning of the year shows no
trend in humidity correction until July 13, 1994.  The last positive
humidity correction was recorded on July 12, 1994 and since then has been
noticably (though slightly) downward.

The humidity correction is applied linearly.  That is, U = U' + (Uo - Uo')
where U is the humidity with the ground check applied (this is the RH
value in our data stream), U' is the humidity measured at the sonde before
correction, Uo is the reference humidity (assumed to be 0%), and Uo' is
is the humidity measured by the sonde in the ground check set.  Users
can recover the RH measured at the sonde by subtracing the global attribute
"humidity-correction" from the RH values in the data set.  Based on our
experience with the ground check data, we expect the RH values measured
at the sonde to be accurate within +/-2% RH.  

 
Other observations/measurements impacted by this problem:  

Any measurement derived from the sonde RH measurement, for example
dew point temperature, water vapor mixing ratio).


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data warning user that RH may be biased high by an unknown amount,
probably not exceeding 2% RH.


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D941104.1
Start DateStart TimeEnd DateEnd Time
10/30/1994232610/30/19942326
Subject:
Bad surface RH value in sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  SGPSONDEC1

Subject:        Bad surface RH value in sounding 10/30/94 23:26

Date Submitted: 11/4/94
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: All
	What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: SGP/CF
 
    Period of time in question
 	Begin Date  10/30/94   Time   23:26    (GMT)
 	End Date    10/30/94   Time   23:26    (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

It looks as though an incorrect value was entered by the operator for
surface relative humidity.  The value entered 16% is much lower than the
first value given by the radiosonde 80%.  The rest of the sounding is
consistent with humid, rainy conditions, suggesting a typographical
error (16 instead of 76?).

 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D941108.2
Start DateStart TimeEnd DateEnd Time
11/06/1994173311/06/19941733
Subject:
Bad surface RH value in sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  SGPSONDEC1

Subject:        Bad surface RH value in sounding 11/6/94 17:33

Date Submitted: 11/8/94
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: All
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: SGP/CF
 
    Period of time in question
     Begin Date  11/06/94   Time   17:33    (GMT)
     End Date    11/06/94   Time   17:33    (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

An incorrect value was entered by the operator for surface relative humidity.  
The value as entered as 4% should be 45%.  This typographical error was
noted in the site operations log by the operator shortly after it occurred.
The remaining values in the sounding should be fine.

 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D941108.4
Start DateStart TimeEnd DateEnd Time
01/21/1993164008/03/19941430
Subject:
CF Sonde Ground Check Corrections
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  SGPSONDEC1

Subject:        CF Sonde Ground Check Corrections

Date Submitted: 11/8/94
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondec1
	What level data: (raw,a0,a1,b1,c1 etc):  all

    What location was the data collected at: SGP/CF
 
    Period of time in question
 	Begin Date  01/21/93   Time   16:40    (GMT)
 	End Date    08/03/94   Time   14:30    (GMT)

 Data should be labeled:
 _?_  questionable                      ___  All data fields affected
 ___  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

Between 1/21/93 and 8/3/94 all radiosondes launched from the central
facility were ground checked before launch.  The ground check procedure
consists of placing the sonde sensor arm into a sealed, dessicated chamber
containing a certified calibrated mercury thermometer, allowing the sonde
to equilibrate, and comparing the sonde output readings for RH and
temperature to the thermometer reading and an assumed 0% RH.  All data after
launch were "corrected" to account for any differences between the sonde
output and the reference conditions in the ground check set.

Analysis of the population of ground check values shows that the average
RH correction was 0% RH and average temperature correction was -0.4 degC.
Because there is some question as to whether applying the ground check
correction increases or decreases the accuracy of the output data, some
investigators may wish to remove the effect of the ground check before
using the data in their analyses.  Ground checks were suspended on 8/3/94.

The algorithms for removing the ground check are:

RH (without ground check) = RH (as reported) - humidity_correction

Temp (without ground chk) = [Temp (as reported) - FACTOR1]/FACTOR2 where

FACTOR1 = [(90*temperature_correction)/(tref+90)
FACOTR2 = [1+(temperature_correction)/(tref+90)

The variables "humidity_correction" and "temperature_correction" are
metadata contained in the netCDF data files from 5/20/93 to 8/3/94.
Between 1/21/93 and 5/20/93 these variables were misnamed and are not
easily accessible via FORTRAN (see PIF 940917.1).

The variable tref is the actual temperature reported by the radiosonde
while in the ground check set.  This variable is not included in the
netCDF file and can be estimated by using a value of 15 degC.  The
correction function is relatively insensitive to variations in this
value.  (see PIF 940917.2)

FORTRAN routines for reading the metadata and for applying the algorithms
to produce "uncorrected" data are available from the instrument mentor.
 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Send (another) notice to users of the data.  

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D941213.1
Start DateStart TimeEnd DateEnd Time
12/09/1994113312/09/19941133
Subject:
Questionable initial values sounding 941209:1133
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondec1

Subject:   Questionable initial values sounding 941209:1133

Date Submitted: 12/12/94
Submitted By:   Barry Lesht           _x_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:  All
	What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: SGP/CF
 
    Period of time in question
 	Begin Date  12/09/94   Time   11:33:00 (GMT)
 	End Date    12/09/94   Time   11:33:02 (GMT)

 Data should be labeled:
 _x_  questionable                      ___  All data fields affected
 ___  incorrect                         _x_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

It appears that incorrect values were entered for surface temperature and
relative humidity in the subject sounding.  The values entered were
temp = 25.1 degC, rh = 18 %.  The next values in the sounding are
temp =- 2.4 degC, rh = 70 %.  Because these do not appear to be simple
typographical errors, the values should be noted as questionable rather
than incorrect until the paper log can be consulted by site ops.

Initial values for subsequent soundings seem fine.

 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Check paper log and flag data.  Note for possible correction later.


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950109.1
Start DateStart TimeEnd DateEnd Time
01/02/1995113201/02/19951132
Subject:
Questionable surface value 1/2/95 11:32
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondec1wrpn

Subject:   Questionable surface value 1/2/95 11:32

Date Submitted: 1/9/95
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:  sgpsondec1
	What level data: (raw,a0,a1,b1,c1 etc):  all

    What location was the data collected at: cf
 
    Period of time in question
 	Begin Date   1/02/95   Time   11:32:00    (GMT)
 	End Date     1/02/95   Time   11:32:02    (GMT)

 Data should be labeled:
 _x_  questionable                      ___  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

It appears that incorrect surface values of temperature and relative
humidity were entered for the subject sounding.



 
Other observations/measurements impacted by this problem:

None



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950109.2
Start DateStart TimeEnd DateEnd Time
01/03/1995112901/03/19951129
Subject:
Questionable surface value 1/3/95 11:29
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondec1wrpn

Subject:   Questionable surface value 1/3/95 11:29

Date Submitted: 1/9/95
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:  sgpsondec1
	What level data: (raw,a0,a1,b1,c1 etc):  all

    What location was the data collected at: cf
 
    Period of time in question
 	Begin Date   1/03/95   Time   11:29:00    (GMT)
 	End Date     1/03/95   Time   11:29:02    (GMT)

 Data should be labeled:
 _x_  questionable                      ___  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

It appears that incorrect surface values of temperature and relative
humidity were entered for the subject sounding.



 
Other observations/measurements impacted by this problem:

None



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950304.1
Start DateStart TimeEnd DateEnd Time
02/22/1995053002/22/19950730
Subject:
Reprocess: Sounding 950222:0530 done in research mode
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:

Subject: Sounding 950222:0530 Done in Research Mode

Date Submitted:  3/4/95
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:  SGPSONDEC1
	What level data: (raw,a0,a1,b1,c1 etc):  ALL

    What location was the data collected at:   SGP/CF
 
    Period of time in question
 	Begin Date   2/22/95   Time   05:30    (GMT)
 	End Date     2/22/95   Time   07:30    (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 _X_  others 
 
 Discussion of Problem:   This sounding was done in RESEARCH mode for
                          both thermodynamic as well as wind data.  The
                          normal mode is to for RESEARCH winds only.  As
                          a result, both the ascending and descending
                          flights of the sonde are included in the data
                          file and none of the data are smoothed or
                          filtered.  

 
Other observations/measurements impacted by this problem:  I think that
                          some of the radiation codes that use the sonde
                          data as input don't handle the descending samples
                          well.  I'm not sure which ones may be affected.


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)  Users should be notified and,
if (and only if) requested, the sounding could be reprocessed either using
the software developed at the EC or the digi-CORA.


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950310.1
Start DateStart TimeEnd DateEnd Time
03/09/1995053003/09/19950530
Subject:
Bad surface values in sounding 3/9/95:0530
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface values in sounding 3/9/95:0530

Date Submitted:  3/10/95
Submitted By:                         _x_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
	What level data: (raw,a0,a1,b1,c1 etc):  all

    What location was the data collected at: sgp/cf
 
    Period of time in question
 	Begin Date   3/09/95   Time   05:30    (GMT)
 	End Date     3/09/95   Time   05:30    (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _x_  incorrect                         _x_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:   It appears that the operator entered incorrect
values for the surface temperature and humidity for this sounding.  The
entered values are 24.8 degC (temp) and 19 %RH (humidity) which are most
likely the values obtained from the met instruments inside the trailer
rather from the sonde on the launch platfrom.  The next sample values of
-3.1 degC (temp) and 81 %RH (humidity) appear to be valid.



 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950316.1
Start DateStart TimeEnd DateEnd Time
03/15/1995142903/15/19951629
Subject:
Reprocess: Sounding 950315:1429 done in research mode
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
P950316.1                                                  Barry Lesht
SGP/SONDE.C1.950315.950315 - Sounding 950315:1429 Done in Research Mode

DQR No:                               Platform:

Subject: Sounding 950315:1429 Done in Research Mode

Date Submitted:  3/4/95
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:  SGPSONDEC1
 What level data: (raw,a0,a1,b1,c1 etc):  ALL

    What location was the data collected at:   SGP/CF

    Period of time in question
  Begin Date   3/15/95   Time   14:29    (GMT)
  End Date     3/15/95   Time   16:29    (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 _X_  others

 Discussion of Problem:   This sounding was done in RESEARCH mode for
                          both thermodynamic as well as wind data.  The
                          normal mode is to for RESEARCH winds only.  As
                          a result, both the ascending and descending
                          flights of the sonde are included in the data
                          file and none of the data are smoothed or
                          filtered.


Other observations/measurements impacted by this problem:  I think that
                          some of the radiation codes that use the sonde
                          data as input don't handle the descending samples
                          well.  I'm not sure which ones may be affected.


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)  Users should be notified and,
if (and only if) requested, the sounding could be reprocessed either using
the software developed at the EC or the digi-CORA.


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950417.1
Start DateStart TimeEnd DateEnd Time
04/13/1995113004/13/19951330
Subject:
Reprocess: Sounding 950413:1130 done in research mode
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:

Subject: Sounding 950413:1130 Done in Research Mode

Date Submitted:  4/17/95
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:  SGPSONDEC1
	What level data: (raw,a0,a1,b1,c1 etc):  ALL

    What location was the data collected at:   SGP/CF
 
    Period of time in question
 	Begin Date   4/13/95   Time   11:30    (GMT)
 	End Date     4/13/95   Time   13:30    (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 _X_  others 
 
 Discussion of Problem:   This sounding was done in RESEARCH mode for
                          both thermodynamic as well as wind data.  The
                          normal mode is to for RESEARCH winds only.  As
                          a result, both the ascending and descending
                          flights of the sonde are included in the data
                          file and none of the data are smoothed or
                          filtered.  

 
Other observations/measurements impacted by this problem:  I think that
                          some of the radiation codes that use the sonde
                          data as input don't handle the descending samples
                          well.  I'm not sure which ones may be affected.


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)  Users should be notified and,
if (and only if) requested, the sounding could be reprocessed either using
the software developed at the EC or the digi-CORA.


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950419.1
Start DateStart TimeEnd DateEnd Time
04/17/1995142904/17/19951551
Subject:
Bad surface values in sounding 4/17/95 14:29
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  SGPSONDEC1

Subject:        Bad surface values in sounding 4/17/95 14:29

Date Submitted: 4/19/95
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: All
	What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: SGP/CF
 
    Period of time in question
 	Begin Date  4/17/95   Time   14:29    (GMT)
 	End Date    4/17/95   Time   15:51    (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The operator entered incorrect surface values for both RH and pressure.
Because of the way altitude is calculated, the incorrect pressure value
has the effect of making all subsequent altitude values incorrect.  The
RH error only affects the first sample.  

 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D950420.1
Start DateStart TimeEnd DateEnd Time
05/06/1994142905/06/19941629
Subject:
SGP/SONDE/C1 - Reprocess: Bad surface pressure
DataStreams:sgpsondeC1.a0, sgpsondeC1.a1
Description:
An incorrect value was entered by the operator for surface pressure. The value as entered 
as 873.9 (hPa) should be 973.9.  This error results in incorrect altitude values 
throughout the sounding and incorrect ascent rate values during the first few minutes.
Measurements:sgpsondeC1.a1:
  • Dry Bulb Temperature(tdry)
  • asc
  • Eastward Wind Component(u_wind)
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • Mean Wind Speed(wspd)
  • lon
  • time_offset
  • Dewpoint Temperature(dp)
  • wstat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • Wind Direction(deg)

sgpsondeC1.a0:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • base_time
  • lat
  • wstat
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • asc
  • alt
  • time_offset
  • lon
  • Dry Bulb Temperature(tdry)
  • Wind Direction(deg)


Back To Table of Contents

DQRID : D950815.1
Start DateStart TimeEnd DateEnd Time
04/11/1994143205/31/19942359
Subject:
SGP/SONDE/C1 - Sonde RESEARCH mode altitudes biased low
DataStreams:sgpsondewrprC1.a0, sgpsondewrprC1.a1, sgpsondewrprB1.a1, sgpsondewrprB1.a0,
sgpsondewrprB4.a1, sgpsondewrprB4.a0, sgpsondewrprB5.a0, sgpsondewrprB5.a1
Description:
EDITOR'S NOTE:  The C1 begin date is actually 4/7/94.  This DQR applies to
all sgpsondewXprFF.aN data, where X is r or n, FF is B1, B4, B5, C1, and
N is 0 or 1.

Discussion of Problem:  I have discovered a problem with the RESEARCH mode
(for PTU) Vaisala processing that results in a negative bias in the calculation
of sonde altitude.  This bias results from neglecting the sensed relative
humidity when calculating air density when integrating the hydrostatic
equation.  In essence, the Vaisala RESEARCH mode (PTU) processing assumes
a dry atmosphere when calculating sonde altitude.  The magnitude of the bias
is cumulative with height and will depend on the vertical distribution of 
moisture, but I have found that it can be as much as 20 meters at the 
tropopause (the RESEARCH-mode sounding altitudes will be smaller than 
altitudes calculated by using sensed RH).  This problem applies to all 
soundings done in 'WXPR' mode, where X is either R or N.  In particular, 
all soundings done during the April 1994 (RCS) IOP (4/7/94 to 5/21/94) 
are affected as well as those occasional inadvertent WXPR soundings.
Note that the only variable affected is 'alt.'

In response to my queries, Vaisala explained that the dry-air calculation was
selected to increase the processing speed in RESEARCH mode.  They consider
the problem to be a minor one.  Vaisala claims that altitudes in NORMAL
(or NOMINAL) processing are calculated by including the sensed RH.
Measurements:sgpsondewrprB4.a1:
  • alt

sgpsondewrprC1.a1:
  • alt

sgpsondewrprB4.a0:
  • alt

sgpsondewrprB5.a0:
  • alt

sgpsondewrprB5.a1:
  • alt

sgpsondewrprB1.a0:
  • alt

sgpsondewrprC1.a0:
  • alt

sgpsondewrprB1.a1:
  • alt


Back To Table of Contents

DQRID : D950816.5
Start DateStart TimeEnd DateEnd Time
08/11/1995175508/11/19951755
Subject:
bad surface tdry value in sounding 17:55
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  SGPSONDEC1

Subject:        Bad surface tdry value in sounding 8/11/95 17:55

Date Submitted: 8/16/95
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: All
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: SGP/CF
 
    Period of time in question
        Begin Date  8/11/95    Time   17:55    (GMT)
        End Date    8/11/95    Time   17:55    (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

An incorrect value was entered by the operator for surface temperature.
The value entered as 28.8 should be 31.8.  This error was noted in the 
site operations log by the operator shortly after it occurred.
The remaining values in the sounding should be fine.

 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D951006.1
Start DateStart TimeEnd DateEnd Time
10/03/1995000010/03/19950100
Subject:
Apparent Interference Signal in Sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sondeC1

Subject: Apparent Interference Signal in Sounding CF:951002:2330

Date Submitted:   October 6, 1995
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
    What level data: (raw,a0,a1,b1,c1 etc):  All

    What location was the data collected at:     CF

    Period of time in question
        Begin Date   10/03/95   Time   XX:XX:XX (GMT)
        End Date     10/03/95   Time   00:54:12 (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:  It appears as if the ground station started to
 receive data from a foreign sonde (i.e., not the sonde originally being
 tracked) at an altitude of about 14.5 km.  At this point the RH signal
 drops out, and both the pressure and temperature signals are noisy and
 look unnatural.


Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

    Flag


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D951006.2
Start DateStart TimeEnd DateEnd Time
10/03/1995000010/03/19950940
Subject:
Apparent Interference Signal in Sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sondeC1

Subject: Apparent Interference Signal in Sounding CF:951003:0830

Date Submitted:   October 6, 1995
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
 What level data: (raw,a0,a1,b1,c1 etc):  All

    What location was the data collected at:     CF

    Period of time in question
  Begin Date   10/03/95   Time   XX:XX:XX (GMT)
  End Date     10/03/95   Time   09:40:20 (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:  It appears as if the ground station started to
 receive data from a foreign sonde (i.e., not the sonde originally being
 tracked) at an altitude of about 14.0 km.  At this point the RH signal
 drops out, and both the pressure and temperature signals are noisy and
 look unnatural.


Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

    Flag


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D951006.3
Start DateStart TimeEnd DateEnd Time
10/03/1995000010/03/19951525
Subject:
Apparent Interference Signal in Sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sondeC1

Subject: Apparent Interference Signal in Sounding CF:951003:1429

Date Submitted:   October 6, 1995
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
 What level data: (raw,a0,a1,b1,c1 etc):  All

    What location was the data collected at:     CF

    Period of time in question
  Begin Date   10/03/95   Time   XX:XX:XX (GMT)
  End Date     10/03/95   Time   15:25:24 (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:  It appears as if the ground station started to
 receive data from a foreign sonde (i.e., not the sonde originally being
 tracked) at an altitude of about 12.7 km.  At this point the RH signal
 drops out, and both the pressure and temperature signals are noisy and
 look unnatural.


Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

    Flag


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D951006.4
Start DateStart TimeEnd DateEnd Time
10/04/1995000010/04/19950707
Subject:
Apparent Interference Signal in Sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sondeC1

Subject: Apparent Interference Signal in Sounding CF:951004:0530

Date Submitted:   October 6, 1995
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
 What level data: (raw,a0,a1,b1,c1 etc):  All

    What location was the data collected at:     CF

    Period of time in question
  Begin Date   10/04/95   Time   XX:XX:XX (GMT)
  End Date     10/04/95   Time   07:07:50 (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:  It appears as if the ground station started to
 receive data from a foreign sonde (i.e., not the sonde originally being
 tracked) at an altitude of about 12.0 km.  At this point the RH signal
 drops out, and both the pressure and temperature signals are noisy and
 look unnatural.


Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

    Flag


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D951006.5
Start DateStart TimeEnd DateEnd Time
10/04/1995000010/04/19950945
Subject:
Apparent Interference Signal in Sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sondeC1

Subject: Apparent Interference Signal in Sounding CF:951004:0834

Date Submitted:   October 6, 1995
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
 What level data: (raw,a0,a1,b1,c1 etc):  All

    What location was the data collected at:     CF

    Period of time in question
  Begin Date   10/04/95   Time   XX:XX:XX (GMT)
  End Date     10/04/95   Time   09:45:30 (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:  It appears as if the ground station started to
 receive data from a foreign sonde (i.e., not the sonde originally being
 tracked) at an altitude of about 11.5 km.  At this point the RH signal
 and the pressure and temperature signals are noisy and look unnatural.


Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

    Flag


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D951006.6
Start DateStart TimeEnd DateEnd Time
10/04/1995000010/04/19951312
Subject:
Apparent Interference Signal in Sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sondeC1

Subject: Apparent Interference Signal in Sounding CF:951004:1130

Date Submitted:   October 6, 1995
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement:
 What level data: (raw,a0,a1,b1,c1 etc):  All

    What location was the data collected at:     CF

    Period of time in question
  Begin Date   10/04/95   Time   XX:XX:XX (GMT)
  End Date     10/04/95   Time   13:12:02 (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:  It appears as if the ground station started to
 receive data from a foreign sonde (i.e., not the sonde originally being
 tracked) at an altitude of about 17.0 km.  At this point the RH signal
 drops out and the pressure and temperature signals are noisy and look
 unnatural.


Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

    Flag


Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960122.1
Start DateStart TimeEnd DateEnd Time
01/17/1996203101/17/19962031
Subject:
Jump in pressure value upon launch
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  SGPSONDEC1

Subject:        Jump in pressure value upon launch 960117:2031

Date Submitted: 1/22/96
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondeWRPNC1/ (alt, asc, press)
    What level data: (raw,a0,a1,b1,c1 etc): all

    What location was the data collected at: SGP/CF
 
    Period of time in question
        Begin Date  1/17/96    Time   20:31    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

It appears that the pressure sensor was jarred during launch and jumped
readings from 975.4 hPa at the surface to 950.2 hPa at the first sample
after launch.  This results in erroneous altitude values throughout the
sounding and erroneous ascent rate values during the first 30 seconds.
The relative altitude calculations after the second sample should be
correct.  Although the surface wind speed was recorded at 10.3 m/s,
the next wind value is reported as 18.2 m/s - quite strong.  The bouncing
of the balloon during the launch might account for the abnormal jarring
of the sonde.


 
Other observations/measurements impacted by this problem:



Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960122.2
Start DateStart TimeEnd DateEnd Time
01/18/1996053301/18/19960533
Subject:
Jump in pressure value upon launch
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  SGPSONDEC1

Subject:        Jump in pressure value upon launch 960118:0533

Date Submitted: 1/22/96
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondeWRPNC1/ (alt, asc, press)
    What level data: (raw,a0,a1,b1,c1 etc): all

    What location was the data collected at: SGP/CF
 
    Period of time in question
        Begin Date  1/18/96    Time   05:33    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

It appears that the pressure sensor was jarred during launch and jumped
readings from 973.1 hPa at the surface to 960.7 hPa at the first sample
after launch.  This results in erroneous altitude values throughout the
sounding and erroneous ascent rate values during the first 30 seconds.
The relative altitude calculations after the second sample should be
correct.  The surface winds were quite strong, 16.5 m/s.  The bouncing
of the balloon during the launch might account for the abnormal jarring
of the sonde.

 
Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960129.1
Start DateStart TimeEnd DateEnd Time
12/13/1995053112/13/19950531
Subject:
Bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding 12/13/95:0531

Date Submitted:  1/29/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
	What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: CF
 
    Period of time in question
 	Begin Date  12/13/95   Time   05:31    (GMT)
 	End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 1010 hPa.
The first pressure value reported by the sonde is 971.8 hPa. Pressure at SMOS13
at 05:30 was 973.7 hPa.  The reason for the discrepency between the apparent
surface pressure and that entered by the operator is unknown.

 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960202.2
Start DateStart TimeEnd DateEnd Time
02/01/1996112902/01/19961129
Subject:
bad pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad pressure sounding 02/01/96:1129

Date Submitted:  2/01/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
 What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: CF

    Period of time in question
  Begin Date  02/01/96   Time   11:29    (GMT)
  End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 962.6.
The first pressure value reported by the sonde is 962.4 hPa. The surface
pressure in the previous (0533) and subsequent (1429) soundings were 983.3
and 985.7 respectively.  SMOS13 pressures were in the 983+ range during
this same period.  It appears that the sonde pressure sensor was bad and
was used as the source of the surface pressure (this is CF standard procedure).
Both the pressure and altitude values for this sounding are likely incorrect.

Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960223.1
Start DateStart TimeEnd DateEnd Time
02/21/1996113102/21/19961131
Subject:
Incorrect surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Incorrect surface pressure sounding 960221:1131

Date Submitted:  2/22/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: CF

    Period of time in question
        Begin Date  02/21/96   Time   11:31    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 995.6 hPa.
The first pressure value reported by the sonde is 972.3 hPa.  It appears that
the operator entered sea-level pressure reported by the WeatherMeasureII instead
of sonde surface pressure. The altitude values for this sounding are likely
incorrect.

Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data and remind operators of current procedures.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960223.2
Start DateStart TimeEnd DateEnd Time
02/21/1996143002/21/19961430
Subject:
Incorrect surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Incorrect surface pressure sounding 960221:1430

Date Submitted:  2/22/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________

For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: CF

    Period of time in question
        Begin Date  02/21/96   Time   14:30    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others

 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 995.6 hPa.
The first pressure value reported by the sonde is 969.7 hPa.  It appears that
the operator entered sea-level pressure reported by the WeatherMeasureII instead
of sonde surface pressure. The altitude values for this sounding are likely
incorrect.

Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data and remind operators of current procedures.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960229.2
Start DateStart TimeEnd DateEnd Time
01/20/1995113009/22/19951130
Subject:
SGP/SONDE/C1 - incorrect factory RH calib-radiosondes
DataStreams:sgpsondewrpnC1.a1, sgpsondewrpnC1.a0
Description:
Ongoing investigation of differences between preciptiable water vapor
measured by the microwave radiometer and precipitable water vapor estimated
by integrating the radiosonde-measured profile of water vapor density, along
with isolated periods of anomalous behavior in the AERI/LBLRTM QME results
led to the suggestion that the calibration of some radiosondes may be suspect.
One group of radiosondes, calibrated in November 1994, seemed particularly
irregular.  I met with the manufacturer on February 7 to show them my
results and discuss this issue with them.  The manufacturer agreed that
the data were suggestive of a calibration problem and offered to review
their calibration records for the period in question.

The initial results of the manufacture's investigation were sent to me
on February 27.  The manufacturer found that radiosondes assembled
between 10/26/94 and 11/22/94 were incorrectly calibrated.  The incorrect
calibration affected only the relative humidity measurement; the nature
of the calibration error is non-linear, with the radiosondes meeting
the specified +/- 2% RH accuracy at both 20%RH (+45 degC) and 0%RH (room
temperature).  The error in calibration occurs at high RH and low temperature
(approximate saturation at -30 degC) and can be as large as 10%RH with
the radiosonde reading high.  The direction of this error agrees with
the observation of negative integrated residuals in the AERI ch 1 region
made by Tony Clough and the tendency toward greater than 'normal' differences
in PWV when compared to the MWR when these sondes were used.

The cause of the calibration error was the addition of new, high RH,
quality control check (-30 degC) into the manufacturing stream that
required a change in the calibration software.  The new software mistakenly
loaded an incorrect parameter file that caused the calibration to be
off at high RH - this was not noticed at the time because the radiosondes
passed the regular production QC checks and the failure to agree at the
new QC value was thought to result from a problem with the new reference
standard.  Troubleshooting the entire calibration system in an effort
to incorporate the new QC check was conducted along with normal production,
and took about a month to complete.  The troubleshooting including adjustment
of the calibration software, at which time the correct parameter file
happened to be reloaded, and after which the radiosondes met the desired
specification at the high RH value.

According to the manufacturer, approximately 1900 radiosondes were calibrated
during the period in question.  Sondes from this period were used at all
CART facilities.  At least 1178 soundings involving these sondes were
included in the QME results I looked at (some QME results were discarded
because of problems with either the MWR data or the sounding data).  The
distribution of these 1178 by facility is:

Facility   Number of Sondes          First Used         Last Used
           (based on QME)
   CF            316               1/20/95 (11:30)    9/22/95 (11:30)
   B1            143               2/21/95 (17:30)    9/29/95 ( 8:30)
   B4            313               4/ 6/95 (17:30)   11/ 7/95 (17:28)
   B5            153               4/14/95 (17:30)   12/14/95 (17:30)
   B6            253               3/22/95 (17:30)   10/19/95 (17:30)

The sondes can be recognized by decoding the serial_number metadata word
in the sounding netCDF file.  The serial number of the sondes in question
is a  number (8 or 9 digit) of the form DDMMYTTPP where DD is the day of
the month (leading zero missing in the netCDF data), MM is the month +80
(e.g. 91 for November), Y is the last digit of the year (4 for 1994),
TT is the calibration tray ID, and PP is the position of the sonde in
the calibration tray.  The sondes in question will therefore have serial
numbers coded between 26904TTPP and 22914TTPP.
Measurements:sgpsondewrpnC1.a1:
  • Humidity, relative(rh)

sgpsondewrpnC1.a0:
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D960403.1
Start DateStart TimeEnd DateEnd Time
04/01/1996143004/01/19961430
Subject:
Bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding 04/01/96 14:30

Date Submitted:  4/2/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: CF
 
    Period of time in question
        Begin Date   4/01/96   Time   14:30    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 1016.1
hPa. The first pressure value reported by the sonde is 988.3 hPa. The surface
pressure at 11:29 was 987.6 and at 17:32 was 988.3.  It appears that the
operator entered the sea-level pressure rather than the station pressure.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960415.1
Start DateStart TimeEnd DateEnd Time
04/12/1996053104/12/19960531
Subject:
Bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding 04/12/96 05:31

Date Submitted:  4/15/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: CF
 
    Period of time in question
    Begin Date   4/12/96   Time   05:31    (GMT)
    End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 996.1
hPa. The first pressure value reported by the sonde is 964.2 hPa. The surface
pressure at 11:30 was 972.0 and at 14:30 was 973.5.  It appears that the
operator entered the sea-level pressure rather than the station pressure.
The SMOS pressure during the period is in the 960-970 range.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960506.1
Start DateStart TimeEnd DateEnd Time
05/06/1996052905/06/19960529
Subject:
Bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding 05/04/96 05:29

Date Submitted:  5/06/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at: CF
 
    Period of time in question
        Begin Date   5/06/96   Time   05:29    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 993.3
hPa. The first pressure value reported by the sonde is 964.0 hPa. The surface
pressure at 08:30 was 964.7 and at 11:31 was 954.3.  It appears that the
operator entered the sea-level pressure rather than the station pressure.
The SMOS pressure during the period is in the 960-950 range.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960602.2
Start DateStart TimeEnd DateEnd Time
05/29/1996203105/29/19962031
Subject:
bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding 05/29/96 20:31

Date Submitted:  6/2/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  05/29/96   Time   20:31    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 999.2
hPa. The first pressure value reported by the sonde is 978.2 hPa. The surface
pressure at 17:25 was 980.1 and at 05:30 (5/30) was 981.8.  It appears that the
operator entered the sea-level pressure rather than the station pressure.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960611.3
Start DateStart TimeEnd DateEnd Time
06/10/1996173006/10/19961730
Subject:
bad surface values sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface values sounding 06/10/96 17:30

Date Submitted:  6/11/96
Submitted By:    Barry Lesht          _X_  Instrument Mentor
                 David Glahn          ___  EST Member
                                      ___  Science Team Member
                                      _X_  Other _Site Ops__________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  06/10/96   Time   17:30    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The site operator inadvertently entered incorrect surface met values for
the subject sounding.  Although he caught the error soon after launch
and reported it immediately, it was too late to correct.  The following
table shows the incorrect (present in the file) and correct values.

                      Incorrect           Correct
Pressure               1000.0              973.9
Temperature              35.0               30.5
Relative Humidity        27                 30

The incorrect values of surface temperature and relative humidity will not
affect the other values in the sounding.  The incorrect surface pressure
will, however, affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960701.4
Start DateStart TimeEnd DateEnd Time
07/01/1996113007/01/19961130
Subject:
Bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding 06/21/96 11:30

Date Submitted:  7/1/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
       Begin Date  07/01/96   Time   11:30    (GMT)
       End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 996.4
hPa. The first pressure value reported by the sonde is 972.3 hPa. The surface
pressure at 05:30 was 972.3 and at 14:46 was 976.1.  It appears that the
operator entered the sea-level pressure rather than the station pressure.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960706.1
Start DateStart TimeEnd DateEnd Time
07/04/1996172807/04/19961728
Subject:
Bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding 07/04/96 17:28

Date Submitted:  7/6/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
	What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
 	Begin Date  07/04/96   Time   17:28    (GMT)
 	End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 995.4
hPa. The first pressure value reported by the sonde is 970.1 hPa. The surface
pressure at 14:30 was 972.3 and at 20:27 was 971.1.  It appears that the
operator entered the sea-level pressure rather than the station pressure.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960913.1
Start DateStart TimeEnd DateEnd Time
09/09/1996142909/09/19961429
Subject:
bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding C1 09/09/96:14:29

Date Submitted:  9/9/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  09/09/96   Time   14:29    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ____  questionable                      ___  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 1001.4
hPa. The first pressure value reported by the sonde is 979.7 hPa.  It appears
that the operator incorrectly entered sea-level pressure obtained from the
WeatherMeasure set rather than surface pressure obtained from the radiosonde.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960913.2
Start DateStart TimeEnd DateEnd Time
09/09/1996173109/09/19961731
Subject:
bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding C1 09/09/96:17:31

Date Submitted:  9/9/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
 	Begin Date  09/09/96   Time   17:31    (GMT)
 	End Date               Time            (GMT)

 Data should be labeled:
 ____  questionable                      ___  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 1001.5
hPa. The first pressure value reported by the sonde is 978.9 hPa.  It appears
that the operator incorrectly entered sea-level pressure obtained from the
WeatherMeasure set rather than surface pressure obtained from the radiosonde.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.

Data Processing Notes                Date




----- End Included Message -----
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960913.3
Start DateStart TimeEnd DateEnd Time
09/09/1996202909/09/19962029
Subject:
bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding C1 09/09/96:20:29

Date Submitted:  9/9/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  09/09/96   Time   20:29    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ____  questionable                      ___  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 999.4
hPa. The first pressure value reported by the sonde is 975.4 hPa.  It appears
that the operator incorrectly entered sea-level pressure obtained from the
WeatherMeasure set rather than surface pressure obtained from the radiosonde.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960913.5
Start DateStart TimeEnd DateEnd Time
09/12/1996083009/12/19960830
Subject:
bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding C1 09/12/96:0830

Date Submitted:  9/13/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  012/96   Time 08:30    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ____  questionable                      ___  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 987.7
hPa. The first pressure value reported by the sonde is 976.1 hPa.  The
operator transposed the correct surface pressure 978.7 when entering the
data.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D960927.2
Start DateStart TimeEnd DateEnd Time
09/27/1996082809/27/19960828
Subject:
Bad surface pressure sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Bad surface pressure sounding C1 09/26/96:0828

Date Submitted:  9/27/96
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  09/27/96   Time 08:28      (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ____  questionable                      ___  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The surface pressure for this sounding was entered by the operator as 976.1
hPa.  Analysis of the raw data file suggests that the actual surface pressure
at time of launch was 967.1 hPa.  It appears that the operator transposed 
the correct surface pressure from 967.1 to 976.1 when entering the data.

Note that this will affect the altitude calculation throughout the sounding.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D970111.1
Start DateStart TimeEnd DateEnd Time
01/10/1997173001/10/19971730
Subject:
Incorrect surface temperature
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Incorrect surface temperature: sounding C1 01/10/97:1730

Date Submitted:  1/11/97
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      _X_  Other - Site Ops
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  01/10/97   Time 17:30      (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ____  questionable                      ___  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The site operator noted that the surface temperature for the subject sounding
was entered incorrectly.  The value entered was -3.3 degC; the correct value
should be -6.3 degC.  This is a fairly benign error, only the surface values
will be affected.
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D970318.2
Start DateStart TimeEnd DateEnd Time
03/07/1997142703/07/19971427
Subject:
Questionable RH
DataStreams:sgpsondewrpnC1.a1
Description:
DQR No:                               Platform: sgpsondeC1

Subject: Questionable RH: sounding C1 03/07/97:1427

Date Submitted:  3/18/97
Submitted By:                         _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other - Site Ops
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnC1.A1/all
    What level data: (raw,a0,a1,b1,c1 etc):

    What location was the data collected at:  CF
 
    Period of time in question
        Begin Date  03/07/97   Time 14:27      (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 _X__  questionable                      _?_  All data fields affected
 _X__  incorrect                         _X_  Only some data fields affected
 _?_  wrong calibration
 ___  others 
 
 Discussion of Problem:

David Cook pointed out that the RH values for the subject sounding disagree
substantially with values reported at the 60m tower.  Review of the sounding
data shows saturation (100%) values reported at the surface and during
most of the sounding.  The site ops log shows RH values of between 68% (1400) 
and 52% (1500) at the surface.  Surface temperature (8.4) and pressure (983.0)
obtained from the sonde are not substantially different from the surface
observations (7.8/10.8) and (982.7/982.4) at 1400 and 1500 respectively, so
it is unlikely that an incorrect calibration tape was used for the sonde.
I think the conclusion must be that the RH sensor on this sonde was bad.

As an operational issue, this sonde should have been rejected by site ops
because the surface RH value of 100% is more than 7% different than the surface
value obtained from an independent reference instrument.  I will check the 
procedures that I have provided to site ops to be sure that I included this
criterion.  
 
Other observations/measurements impacted by this problem:

None

Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D970507.2
Start DateStart TimeEnd DateEnd Time
05/05/1997173205/05/19971732
Subject:
Jump in pressure value
DataStreams:sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  sgpsondeC1

Subject:        Jump in pressure value C1 sounding 970505.1732

Date Submitted: 5/06/97
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnc1/ (alt, asc, press)
    What level data: (raw,a0,a1,b1,c1 etc): all

    What location was the data collected at: SGP/CF
 
    Period of time in question
        Begin Date  5/05/97    Time   17:32    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      _X_  All data fields affected
 _X_  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

The first pressure value reported by the radiosonde (t = 2 sec) is
974.9.  The surface pressure value was 980.9 hPa.  This difference
is somewhat greater than the expected (normal) change and may mean that
either the pressure sensor was jarred during launch or the system 
mis-identified the actual launch start time.  Further clarification requires 
analysis of the raw data which will take some time.  The altitude values 
for this sounding will be incorrect.  The ascent rate values during the 
first 30 seconds also will be wrong.  Because the system will reject 
samples with out of bound ascent rates (i.e., during the first 30 seconds), 
the temperature and rh values also will be incorrect (result of 
interpolation).  Relative height values after 30 seconds should be okay.

 
Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D970624.2
Start DateStart TimeEnd DateEnd Time
06/21/1997202706/21/19972027
Subject:
Incorrect surface values
DataStreams:sgpsondewrpnC1.a1
Description:
DQR No:                               Platform:  sgpsondeC1

Subject:        Incorrect surface values sounding 970621:2027

Date Submitted: 6/23/97
Submitted By:   Barry Lesht           _X_  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      ___  Other _____________________________
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at dqr@arm.gov.

Platform/Measurement: sgpsondewrpnc1
    What level data: (raw,a0,a1,b1,c1 etc): all

    What location was the data collected at: SGP/CF
 
    Period of time in question
        Begin Date  6/21/97    Time   20:27    (GMT)
        End Date               Time            (GMT)

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 _X_  incorrect                         _X_  Only some data fields affected
 ___  wrong calibration
 ___  others 
 
 Discussion of Problem:

Site operations reports that incorrect surface values were entered into
the subject sounding.  Instead of 972.3, 33.7, and 46 the surface pressure,
temperature, and humidity values should have been 971.8, 33.3, and 47.

The incorrect surface pressure will result in incorrect altitudes throughout
the profile and incorrect ascent rate values during the first 30 seconds.
The effects of the incorrect temperature and relative humidty values should
be negligable.
 
Other observations/measurements impacted by this problem:


Suggested Corrections of the Problem: (e.g. change calibration factor and
recompute, flag data with this comment, etc.)

Flag data.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D970625.1
Start DateStart TimeEnd DateEnd Time
06/22/1997022806/22/19970236
Subject:
Bad sounding file CF 970622:0228
DataStreams:sgpsondewrpnC1.a1
Description:
It appears that there was a problem with the radiosonde that generated
this short file. The pressure values are unreasonably high and the
file terminated after only 484 seconds of flight.  I note that the
operators started a new sounding at 0252.  This entire file should be
disregarded or deleted.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D970709.1
Start DateStart TimeEnd DateEnd Time
07/04/1997052507/04/19970630
Subject:
Bad pressure values CF sounding 970704:0525
DataStreams:sgpsondewrpnC1.a1
Description:
The pressure values and hence altitude values are most likely incorrect
in this sounding.  It also appears that an incorrect surface pressure
value was entered by the operator.  The surface pressure value in
the data (986.8) is somewhat higher than the surface pressures for the
neighboring soundings and higher than recorded in the raw data collected
before launch (~978 hPa).  The first pressure value recorded by the
sonde after launch is 884.8 hPa.  Analysis of the absolutely raw data
reveals that the sonde was reading about 978 hPa well before launch,
then suddenly dropped to 886.8 at which it remained stable for several
minutes, then began slowly decreasing as would be expected after launch.
My best guess is that the sonde was somehow damaged during handling
before launch resulting in erroneous pressure values.  Relative pressure
changes from an 'apparent' surface value of 886.8 hPa may be correct,
but the absolute pressure values are not.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D970710.1
Start DateStart TimeEnd DateEnd Time
04/29/1996052704/29/19960527
Subject:
Questionable pressure/altitude data
DataStreams:sgpsondewrpnC1.a1
Description:
Ric Cederwall noticed that the lowest 85 samples of this sounding have
nearly constant values of temperature and relative humidity.  It appears
that the system may have mis-identified the launch start time in a way
that resulted in the system using interpolated values of pressure even
though the sonde was still on the ground.  This may have been caused by
a damaged pressure sensor.  I will examine the absolutely raw data to
try and understand this further, but I think it is reasonable to assume
that the first 85 samples or so are incorrect and representative of
condidtions at the surface and that the pressure sensor was damaged
during this sounding.  I will request the raw data from the archive
today.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D970923.2
Start DateStart TimeEnd DateEnd Time
09/21/1997053009/21/19970530
Subject:
Pressure jump at launch
DataStreams:sgpsondewrpnC1.a1
Description:
The difference between the first pressure value recorded by the radiosonde
after launch (984.5) that the surface value entered by the operator (989.3)
is somewhat larger than would normally be expected.  This will result in
incorrect altitude values throughout the sounding.  The ascent rates
during the first 30 seconds also will be incorrect.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D980126.1
Start DateStart TimeEnd DateEnd Time
01/01/1998000012/31/19992359
Subject:
Incorrect radiosonde serial numbers
DataStreams:sgpsondewrpnB1.a0, sgpsondewrpnB1.a1, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1,
sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.a0, sgpsondewrpnB6.a1, sgpsondewrpnC1.a0,
sgpsondewrpnC1.a1
Description:
Radiosondes manufactured at Vaisala's Woburn, MA factory during the first
of January 1998 have incorrect serial numbers.  Instead of being numbered
8012XXXXX these sondes are numbered 7012XXXXX.  Vaisala has been informed
of this, has confirmed the problem, and has corrected their numbering for
all subsequent sondes.  163 incorrectly numbered sondes were shipped to ARM
on 1/9/98.  Some have been used at the CF since 1/19/98:1430.
Measurements:sgpsondewrpnB4.a0:
  • lon
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • Wind Direction(deg)
  • Dry Bulb Temperature(tdry)
  • base_time
  • time_offset
  • asc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Dewpoint Temperature(dp)
  • wstat
  • lat
  • alt

sgpsondewrpnB5.a0:
  • wstat
  • Humidity, relative(rh)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Wind Direction(deg)
  • lon
  • alt
  • asc
  • time_offset
  • Mean Wind Speed(wspd)
  • base_time
  • Dewpoint Temperature(dp)
  • lat
  • Dry Bulb Temperature(tdry)

sgpsondewrpnB5.a1:
  • Dry Bulb Temperature(tdry)
  • time_offset
  • wstat
  • Dewpoint Temperature(dp)
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • Humidity, relative(rh)
  • asc
  • base_time
  • Eastward Wind Component(u_wind)
  • Wind Direction(deg)
  • lon
  • Northward Wind Component(v_wind)
  • Mean Wind Speed(wspd)

sgpsondewrpnB4.a1:
  • asc
  • Dewpoint Temperature(dp)
  • lon
  • Northward Wind Component(v_wind)
  • time_offset
  • Eastward Wind Component(u_wind)
  • Humidity, relative(rh)
  • Dry Bulb Temperature(tdry)
  • base_time
  • alt
  • wstat
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • Mean Wind Speed(wspd)
  • Wind Direction(deg)

sgpsondewrpnB1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Northward Wind Component(v_wind)
  • lat
  • asc
  • Wind Direction(deg)
  • lon
  • Dry Bulb Temperature(tdry)
  • wstat
  • Humidity, relative(rh)
  • Eastward Wind Component(u_wind)
  • alt
  • base_time
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • time_offset

sgpsondewrpnB1.a0:
  • alt
  • wstat
  • asc
  • Humidity, relative(rh)
  • lon
  • lat
  • base_time
  • Mean Wind Speed(wspd)
  • time_offset
  • Dewpoint Temperature(dp)
  • Wind Direction(deg)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Dry Bulb Temperature(tdry)

sgpsondewrpnB6.a0:
  • base_time
  • wstat
  • asc
  • Dry Bulb Temperature(tdry)
  • lat
  • Dewpoint Temperature(dp)
  • Wind Direction(deg)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • Humidity, relative(rh)
  • lon
  • alt
  • Mean Wind Speed(wspd)

sgpsondewrpnC1.a1:
  • Eastward Wind Component(u_wind)
  • alt
  • Mean Wind Speed(wspd)
  • Wind Direction(deg)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • lat
  • Northward Wind Component(v_wind)
  • time_offset
  • Dewpoint Temperature(dp)
  • lon
  • base_time
  • Humidity, relative(rh)
  • asc
  • Dry Bulb Temperature(tdry)
  • wstat

sgpsondewrpnC1.a0:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Humidity, relative(rh)
  • alt
  • lat
  • lon
  • base_time
  • asc
  • Dewpoint Temperature(dp)
  • wstat
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • time_offset
  • Wind Direction(deg)

sgpsondewrpnB6.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • Mean Wind Speed(wspd)
  • Eastward Wind Component(u_wind)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)
  • Dry Bulb Temperature(tdry)
  • base_time
  • Northward Wind Component(v_wind)
  • wstat
  • lon
  • asc
  • Wind Direction(deg)
  • alt


Back To Table of Contents

DQRID : D980126.2
Start DateStart TimeEnd DateEnd Time
01/19/1998113001/19/19981130
Subject:
Incorrect surface temperature and humidity
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
Incorrect values of surface temperature and relative humidity were entered
by the operator.  The surface temperature was entered as 17.5 degC; the
first value reported by the sonde was -3.6 degC.  The surface humidity
was entered as 26; the first value reported by the sonde was 81%. It
appears that the operator used the inside temperature/humidity rather
than the sonde-reported outside temperature/humidity.

Only the first few samples of the sounding will be affected.  Note that
the delta-check QC flag is set by this error.
Measurements:sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D980506.1
Start DateStart TimeEnd DateEnd Time
04/29/1998143104/29/19981431
Subject:
Incorrect surface values
DataStreams:sgpsondewrpnC1.a1
Description:
The surface pressure, temperature, and relative humidity are incorrect for
this soundings.  The values in the sounding netCDF file (975.6, 3.2, 86)
are different from the surface observations in the site ops log (978.9,
9.1, and 83) and from the values in the raw radiosonde data file at
the moment just before ascent (978.7, 9.5, 83).  The reason for the
differences are unknown, but insofar as the surface values are manually
entered by the operator into both the log (where they are correct) and
into the sounding file (where they are incorrect) an operator
miscue is a possibility.

The major effect of this problem will be incorrect absolute altitude.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D980507.4
Start DateStart TimeEnd DateEnd Time
05/06/1998083205/06/19980832
Subject:
Incorrect surface pressure
DataStreams:sgpsondewrpnC1.a1
Description:
The operator transposed the digits of the surface pressure entering 976.3
instead of 967.3.  The ops log shows 967.3 for the sonde and 968.3 for
the THWAPS.  Analysis of the absolutely raw sonde data shows 968.0 at
the system-identified launch time.

Note that because the output pressure data are smoothed, under the
assumption that the surface data value is true, the first value
reported by the sonde after launch 970.4 also is incorrect.  The raw
value corresponding to the sample after launch is 966.6.

The absolute pressure values will be incorrect for the first few samples
of the sounding, as will be the ascent rates for the first 30 seconds.
The absolute altitude values also will be in error.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D980511.2
Start DateStart TimeEnd DateEnd Time
05/09/1998143105/09/19981431
Subject:
Incorrect surface pressure
DataStreams:sgpsondewrpnC1.a1
Description:
The operator entered 960.2 for the surface pressure in both the log and
the system.  The first reading from the sonde is 950.9.  Examination of
the absolutely raw data shows that the sonde pressure before launch was
952.3.  The THWAPS reading was 964.2.  From the raw data it appears that
either the system was not reset before this sounding or that a second
sonde was started without resetting the system.  The sonde pressure
may be low in absolute terms or the operator may have mis-entered the
actual sonde reading.  In either case the absolute altitude will be wrong
in this sounding and the ascent rates will be incorrect for the first
30 seconds.
Measurements:sgpsondewrpnC1.a1:
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Humidity, relative(rh)
  • Northward Wind Component(v_wind)
  • asc
  • Eastward Wind Component(u_wind)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time
  • alt
  • Dry Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D980716.1
Start DateStart TimeEnd DateEnd Time
07/14/1998234607/14/19982346
Subject:
Bad sounding
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
Data from this sounding look very fragmented as if only a few actual points
were collected and intermediate points were intepolated.  In a general
sense this sounding looks 'weird' and should not be trusted.  I do not yet
have access to r1 so I can't look at the raw data, but I doubt that it will
shed much light on the situation.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D980917.1
Start DateStart TimeEnd DateEnd Time
05/09/1998202905/09/19982029
Subject:
Incorrect surface readings
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
It appears that the operator entered an incorrect set of surface data for
the subject sounding.  The sounding has surface PTU as 975.6 hPa, 20.0 degC,
and 93% RH - the corresponding THWAPS readings are 969.7 hPa, 19.9 degC, and
72.1 %RH.  The OMIS log for the subject souding shows sonde surface values
of 969.2 hPa, 17.6 degC, and 70% RH.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D980917.2
Start DateStart TimeEnd DateEnd Time
05/07/1998232905/07/19982329
Subject:
Incorrect surface RH
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
Because of what appears to be a typographical error, the operator entered
5% RH when the surface RH was 54% RH.  The corresponding THWAPS reading
is 50.1% RH and the OMIS log shows 54%RH.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D990124.2
Start DateStart TimeEnd DateEnd Time
05/27/1992000005/31/20022359
Subject:
SGP/SONDE - Dry bias in sonde RH
DataStreams:sgpsondewnpnB1.a1, sgpsondewnpnB4.a0, sgpsondewnpnB4.a1, sgpsondewnpnB5.a0,
sgpsondewnpnB5.a1, sgpsondewnpnB6.a0, sgpsondewnpnB6.a1, sgpsondewnpnC1.a0, sgpsondewnpnC1.a1,
sgpsondewnprC1.a0, sgpsondewnprC1.a1, sgpsondewrpnB1.00, sgpsondewrpnB1.a0,
sgpsondewrpnB1.a1, sgpsondewrpnB4.00, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1, sgpsondewrpnB5.00,
sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.00, sgpsondewrpnB6.a0,
sgpsondewrpnB6.a1, sgpsondewrpnC1.00, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrprB1.00,
sgpsondewrprB1.a0, sgpsondewrprB1.a1, sgpsondewrprB4.00, sgpsondewrprB4.a0, sgpsondewrprB4.a1,
sgpsondewrprB5.00, sgpsondewrprB5.a0, sgpsondewrprB5.a1, sgpsondewrprC1.00,
sgpsondewrprC1.a0, sgpsondewrprC1.a1, DsgpsondeB1.00, DsgpsondeB1.a0, DsgpsondeB1.a1,
DsgpsondeB4.00, DsgpsondeB4.a0, DsgpsondeB4.a1, DsgpsondeB5.00, DsgpsondeB5.a0, DsgpsondeB5.a1,
DsgpsondeC1.00, DsgpsondeC1.a0, DsgpsondeC1.a1, DsgpsondenogcptucalcB1.c1,
DsgpsondenogcptucalcB4.c1, DsgpsondenogcptucalcB5.c1, DsgpsondenogcptucalcC1.c1,
DsgpsondenogcwrpnB1.c1, DsgpsondenogcwrpnB4.c1, DsgpsondenogcwrpnB5.c1, DsgpsondenogcwrpnC1.c1,
DsgpsondeptuB1.00, DsgpsondeptuB4.00, DsgpsondeptuB5.00, DsgpsondeptuB6.00,
DsgpsondeptuC1.00, DsgpsondeptucalcB1.c1, DsgpsondeptucalcB4.c1, DsgpsondeptucalcB5.c1,
DsgpsondeptucalcC1.c1, sgpsondeB1.00, sgpsondeB1.a0, sgpsondeB1.a1, sgpsondeB4.00, sgpsondeB4.a0,
sgpsondeB4.a1, sgpsondeB5.00, sgpsondeB5.a0, sgpsondeB5.a1, sgpsondeB6.00,
sgpsondeC1.00, sgpsondeC1.a0, sgpsondeC1.a1, sgpsondeptuC1.00, sgpsondewnpnB1.a0
Description:
Vaisala has confirmed ARM findings of an apparent dry bias in the
relative humidity measured by RS-80H radiosondes.  The cause of
the dry bias is thought to be contamination of the humidity sensor
by volatile organic substances originating from some plastic parts
of the radiosonde.  The amount of contamination is a function of
the time between the date of sonde manufacture and its use.  All
RS-80H sondes manufactured before week 34 of 1998 will show this
bias.  After week 34 of 1998 Vaisala changed its packaging to
reduce, but not eliminate the contamination problem.

Starting with RS-80 radiosonde manufactured in late June 2000 Vaisala
enclosed the sensor boom in an inert plastic shield, thereby eliminating
the contamination that caused the dry bias.

Starting in May 2001 at the SGP, May 2002 at the TWP, and later 2002
at the NSA, ARM has moved to using RS-90 radiosondes.  These sondes
are not subject to the contaminatino that caused the dry bias.

Vaisala is in the process of developing an algorithm that can be 
used to estimate the correct RH from knowledge of the sonde age.
All of the ARM sounding data have sufficient metadata available
to apply the correction.

Additionally, ARM has funded a Science Team effort (Milosevich) to
develop a 'best' correction algorithm for the RS-80 radiosonde humidity
data.  When completed this algorithm will allow us to reprocess the
accumulated RS-80 data and produce a new data platform with what we
hope will be more accurate data.
Measurements:sgpsondeptuC1.00:
  • Raw data stream - documentation not supported

sgpsondeB4.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondeB4.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeptuB4.00:
  • Development raw data stream - documentation not supported

sgpsondewrprB1.00:
  • Raw data stream - documentation not supported

DsgpsondeC1.a1:
  • Development data stream - documentation not supported

DsgpsondeB5.a0:
  • Development data stream - documentation not supported

DsgpsondeC1.a0:
  • Development data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnprC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

DsgpsondenogcptucalcC1.c1:
  • Development data stream - documentation not supported

sgpsondewrpnB5.00:
  • Raw data stream - documentation not supported

sgpsondewrpnB4.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewnpnB1.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnB1.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeB5.a1:
  • Development data stream - documentation not supported

sgpsondewrprB4.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewrpnB4.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

DsgpsondeB4.a0:
  • Development data stream - documentation not supported

sgpsondewrpnB6.00:
  • Raw data stream - documentation not supported

DsgpsondeB4.a1:
  • Development data stream - documentation not supported

sgpsondewrprB4.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeptuB6.00:
  • Development raw data stream - documentation not supported

sgpsondewnpnC1.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewrpnB6.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

DsgpsondeptuB5.00:
  • Development raw data stream - documentation not supported

sgpsondewnpnC1.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondenogcwrpnB4.c1:
  • Development data stream - documentation not supported

DsgpsondeB4.00:
  • Development raw data stream - documentation not supported

sgpsondewrpnB6.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondenogcptucalcB4.c1:
  • Development data stream - documentation not supported

DsgpsondeC1.00:
  • Development raw data stream - documentation not supported

DsgpsondeptuC1.00:
  • Development raw data stream - documentation not supported

DsgpsondeptucalcB1.c1:
  • Development data stream - documentation not supported

sgpsondewrpnB1.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeptucalcB5.c1:
  • Development data stream - documentation not supported

sgpsondewrpnB1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnB1.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeptuB1.00:
  • Development raw data stream - documentation not supported

DsgpsondeB1.00:
  • Development raw data stream - documentation not supported

DsgpsondeptucalcB4.c1:
  • Development data stream - documentation not supported

DsgpsondenogcwrpnB5.c1:
  • Development data stream - documentation not supported

sgpsondewrpnB5.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewrpnB5.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

DsgpsondenogcptucalcB1.c1:
  • Development data stream - documentation not supported

sgpsondeC1.00:
  • Raw data stream - documentation not supported

sgpsondewrprB4.00:
  • Raw data stream - documentation not supported

sgpsondeB4.00:
  • Raw data stream - documentation not supported

sgpsondewrprB1.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewrprC1.00:
  • Raw data stream - documentation not supported

sgpsondewrprB1.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewnpnB5.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondeB1.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeB5.00:
  • Development raw data stream - documentation not supported

sgpsondewnpnB5.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondeB1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnB4.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewnpnB6.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnB6.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewnpnB4.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

DsgpsondenogcwrpnB1.c1:
  • Development data stream - documentation not supported

sgpsondeB5.00:
  • Raw data stream - documentation not supported

sgpsondeB6.00:
  • Raw data stream - documentation not supported

DsgpsondenogcptucalcB5.c1:
  • Development data stream - documentation not supported

sgpsondewrprB5.00:
  • Raw data stream - documentation not supported

DsgpsondeptucalcC1.c1:
  • Development data stream - documentation not supported

DsgpsondenogcwrpnC1.c1:
  • Development data stream - documentation not supported

sgpsondeC1.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondeC1.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeB1.a0:
  • Development data stream - documentation not supported

sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondeB5.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewrpnB4.00:
  • Raw data stream - documentation not supported

sgpsondeB5.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

DsgpsondeB1.a1:
  • Development data stream - documentation not supported

sgpsondewrprC1.a1:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewrprB5.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondewrprB5.a1:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewrpnC1.a0:
  • Humidity, relative(rh)
  • Dewpoint Temperature(dp)

sgpsondewnprC1.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)

sgpsondeB1.00:
  • Raw data stream - documentation not supported

sgpsondewrprC1.a0:
  • Dewpoint Temperature(dp)
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D990210.1
Start DateStart TimeEnd DateEnd Time
02/09/1999083402/09/19991016
Subject:
SGP/SONDE - Wrong cal tape
DataStreams:sgpsondewndcalcC1.c1, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
There is something wrong with this sounding, its not clear exactly
what happened, however.  The first values reported by the radiosonde
are much different from those entered by the operator.  My impression
is that this is a calibration tape mixup.  The raw data file shows
that the sounding software was initialized twice for this sounding,
the first time showing sonde 823360910, the second time showing
sonde 819351814.  There is no enties in the operations log that
describe a problem with a sonde before launch.
Measurements:sgpsondewndcalcC1.c1:
  • lat
  • base_time
  • lon
  • u_wind_calc
  • alt
  • v_wind_flags
  • u_wind_flags
  • time_offset
  • v_wind_calc
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)

sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • Dry Bulb Temperature(tdry)
  • alt
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • Dry Bulb Temperature(tdry)
  • wstat
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D990303.1
Start DateStart TimeEnd DateEnd Time
03/02/1999082803/02/19990828
Subject:
SGP/SONDE - Pressure jump at launch
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
The difference between the sonde-reported pressure at the surface
(969.1 hPa) and the first pressure value reported after launch
(963.5) is larger than expected.  This may indicate that either
the pressure sensor was jarred at launch, that the system failed
to correctly identify the launch start time, or some other problem.

The ascent rates during the first 30 seconds of the sounding will be
incorrect as will the absolute altitudes during the sounding.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D990329.1
Start DateStart TimeEnd DateEnd Time
03/22/1999023003/22/19990230
Subject:
Incorrect surface RH
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
The operator entered an incorrect value (7.5%) for the surface RH for this
sounding.  The correct value should have been 70%.  The operator noticed
the error after the sounding had been completed and reported it in his log.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D990513.1
Start DateStart TimeEnd DateEnd Time
05/10/1999113005/11/19992041
Subject:
SGP/SONDE - RH probably biased low in several soundings
DataStreams:sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrpnC1.00
Description:
In the process of moving storage facilties, site operations uncovered some old radiosondes 
(vintage April 1998) that were used in several soundings starting on May 10 at 0530 and 
continuing at least through May 11 at 2040.
Because these sondes are so old and pre-date Vaisala's repackaging they are likely subject 
to the sensor contamination problem that results in a dry bias in RH.  The sondes in 
question have serial numbers 816XXXXXX.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D991221.1
Start DateStart TimeEnd DateEnd Time
12/18/1999053012/18/19990530
Subject:
SGP/SONDE - Incorrect surface temperature
DataStreams:sgpsondewrpnC1.00, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1
Description:
The operator entered 20.0 degrees rather than the true temperature of 2.0
degrees.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • alt
  • Dry Bulb Temperature(tdry)
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • Dry Bulb Temperature(tdry)
  • wstat
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents

DQRID : D991228.1
Start DateStart TimeEnd DateEnd Time
12/22/1999233012/22/19992330
Subject:
SGP/SONDE - Incorrect surface temperature
DataStreams:sgpsondewrpnC1.a1, sgpsondewrpnC1.a0, sgpsondewrpnC1.00
Description:
The operator entered the surface temperature as 25 degC rather than the
correct 2.5 deg C.  This is the second time in a week this type of error
has occurred.  I have sent a separate e-mail to site ops.
Measurements:sgpsondewrpnC1.00:
  • Raw data stream - documentation not supported

sgpsondewrpnC1.a1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • time_offset
  • lat
  • Northward Wind Component(v_wind)
  • Humidity, relative(rh)
  • asc
  • Eastward Wind Component(u_wind)
  • Dry Bulb Temperature(tdry)
  • alt
  • Mean Wind Speed(wspd)
  • Dewpoint Temperature(dp)
  • lon
  • wstat
  • Wind Direction(deg)
  • base_time

sgpsondewrpnC1.a0:
  • base_time
  • alt
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • asc
  • Wind Direction(deg)
  • Dewpoint Temperature(dp)
  • lat
  • wstat
  • Dry Bulb Temperature(tdry)
  • Humidity, relative(rh)
  • Mean Wind Speed(wspd)
  • lon
  • time_offset


Back To Table of Contents