DQR ID | Subject | Data Streams Affected |
---|---|---|
D090724.1 | NSA/TWR/C2 - Reprocess: 5m vapor pressure incorrect at temps above freezing | nsatwrC2.b1 |
D090924.2 | NSA/TWR/C2 - 5m RH values Incorrect | nsatwrC2.b1 |
D091030.3 | NSA/MET/C2 - CMH Data Incorrect During Maintenance | nsametC2.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/09/2008 | 0000 | 07/21/2009 | 1749 |
Subject: | NSA/TWR/C2 - Reprocess: 5m vapor pressure incorrect at temps above freezing |
DataStreams: | nsatwrC2.b1 |
Description: | The 5m Vapor pressure calculation was in error for temperatures equal to or above 0C. The 2m Dew Point values were used for calculating the Vapor Pressure when the temps were equal to or above 0C. The following formula should be used to correct the data: VP5M = (6.1365 (EXP((17.502*DP5M)/(240.97+DP5M))))*0.1. |
Measurements: | nsatwrC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/31/2009 | 1630 | 10/17/2009 | 0135 |
Subject: | NSA/TWR/C2 - 5m RH values Incorrect |
DataStreams: | nsatwrC2.b1 |
Description: | The 5m RH sensor cap had fallen off and caused the 5m RH readings to be incorrect during times of high RH (>95%). |
Measurements: | nsatwrC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/23/2009 | 0047 | 10/23/2009 | 1958 |
Subject: | NSA/MET/C2 - CMH Data Incorrect During Maintenance |
DataStreams: | nsametC2.b1 |
Description: | Data was incorrect as the CMH was offline and undergoing maintenance. |
Measurements: | nsametC2.b1:
|