DQRID : D080428.4
Start DateStart TimeEnd DateEnd Time
07/01/2004000006/30/20102359
Subject:
TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values
DataStreams:twpsmet60sC2.b1
Description:
The ORG data is collected via analog signal and not digital.  Therefore, we continuously 
collect data even when no rain is occurring.  We also capture small events such as leaves, 
large bugs, dust, etc blowing through the measurement path.  Because this discrete event 
occurs quickly the value is usually captured for 1 or 2 seconds.  This value is then 
averaged to the minute producing rainrate on the order of .009 mm/hr or less.  

These values are not indicative of rain and should be removed from the record or summing 
over long periods can bias the climate record.  We will reprocess the data to remove these 
small values.
Measurements:twpsmet60sC2.b1:
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • precip_sd


Back To Table of Contents

DQRID : D081022.5
Start DateStart TimeEnd DateEnd Time
11/01/1998000002/23/20090410
Subject:
TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC2.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC2.b1:
  • lo_spd_arith_avg
  • lo_spd_min
  • lo_spd_vec_avg
  • up_spd_min
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_sd
  • up_spd_max
  • lo_spd_sd
  • up_spd_vec_avg


Back To Table of Contents

DQRID : D090604.2
Start DateStart TimeEnd DateEnd Time
05/20/2009000406/05/20092359
Subject:
TWP/SMET/C2 - Barometer data incorrect
DataStreams:twpsmet60sC2.b1
Description:
Beginning 05/20, atmos_pressure exceeded MAX between ~21:00 and 01:00 UTC on most days.  
The inlet tube was accidentally pinched in the door of the logger enclosure artificially 
increasing the atmospheric pressure during the listed times.  Only a few hours exceeded 
max limits.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D090918.1
Start DateStart TimeEnd DateEnd Time
07/01/2009010010/15/20090300
Subject:
TWP/SMET/C2 - Induced wind speed when calm
DataStreams:twpsmet60sC2.b1
Description:
The upper and lower wind sensors were not trending well at wind speed below 1 m/s.  Both 
sensors were showing values above 0m/s when calm.  The lightning protector was at fault 
resulting in an induced wind voltage during calm conditions.

Users should subtract any offset found (for example 0.19 m/s for upper wind speed) when 
the wind speeds are flat-lined.  The offset value was not consistent.
Measurements:twpsmet60sC2.b1:
  • lo_spd_arith_avg
  • lo_spd_min
  • lo_spd_vec_avg
  • up_spd_min
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_max
  • up_spd_vec_avg


Back To Table of Contents

DQRID : D091030.2
Start DateStart TimeEnd DateEnd Time
10/14/2009215010/15/20090315
Subject:
TWP/SMET/C2 - Tower Lowered for Maintenance
DataStreams:twpsmet60sC2.b1
Description:
Data is suspect due to the tower being lowered.
Measurements:twpsmet60sC2.b1:
  • vappress_sd
  • lo_spd_arith_avg
  • relh_sd
  • lo_spd_min
  • lo_dir_vec_avg
  • temp_sd
  • up_dir_vec_avg
  • lo_spd_vec_avg
  • Vapor pressure mean(vappress_mean)
  • up_spd_min
  • up_dir_sd
  • up_spd_max
  • Mean Air Temperature or Hardware Error(temp_mean)
  • up_spd_vec_avg
  • lo_dir_sd
  • Relative humidity mean(relh_mean)
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_sd
  • lo_spd_sd


Back To Table of Contents



END OF DATA