Data Quality Reports for Session: 142922 User: ql_data Completed: 06/07/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D111027.1SGP/RAIN/C1 - Missing datasgprainC1.b1
D120113.5SGP/RAIN/C1 - Reprocess: Incorrect datestampsgprainC1.b1
D120301.2SGP/RAIN/C1 - Lightning strikesgprainC1.b1


DQRID : D111027.1
Start DateStart TimeEnd DateEnd Time
09/27/2011183709/28/20110120
10/07/2011142710/18/20111527
09/01/2011001209/03/20112206
09/17/2011123809/19/20111516
Subject:
SGP/RAIN/C1 - Missing data
DataStreams:sgprainC1.b1
Description:
The datalogger connection was disrupted resulting in no data from the weighing bucket rain 
gauge.
Measurements:sgprainC1.b1:
  • total_mm
  • total_weight
  • error_latch
  • stat_latch
  • frequency2
  • frequency1
  • frequency3
  • Precipitation rate(precip_rate)
  • Precipitation, total(precip)
  • temp3
  • weight3
  • weight2
  • temp1
  • weight1
  • Model derived 2-meter temperature(temp2)


Back To Table of Contents

DQRID : D120113.5
Start DateStart TimeEnd DateEnd Time
11/21/2011000011/21/20112359
Subject:
SGP/RAIN/C1 - Reprocess: Incorrect datestamp
DataStreams:sgprainC1.b1
Description:
The datestamp was off by one day for a several day period. Precipitation was only reported 
for one day during this time period.  The data for 20111121 should be reported as 
20111122.
Measurements:sgprainC1.b1:
  • maintenance_cnt
  • total_mm
  • volt_min
  • error_latch
  • alt
  • stat_latch
  • weight3
  • time_offset
  • weight2
  • weight1
  • time
  • total_weight
  • base_time
  • scans_per_min
  • lon
  • frequency2
  • frequency1
  • Precipitation rate(precip_rate)
  • lat
  • frequency3
  • Precipitation, total(precip)
  • ptemp
  • temp3
  • temp1
  • Model derived 2-meter temperature(temp2)


Back To Table of Contents

DQRID : D120301.2
Start DateStart TimeEnd DateEnd Time
06/12/2011050006/15/20110000
Subject:
SGP/RAIN/C1 - Lightning strike
DataStreams:sgprainC1.b1
Description:
A lightning strike took out the instrument on 6/12.  Error_latch and stat_latch flags were 
tripped and the instrument failed to record precip measured by co-located instruments 
(e.g. on 6/13).  Voltage and other data fields were also very erratic.

Instrument was replaced and normal operations resumed on 20110615.
Measurements:sgprainC1.b1:
  • maintenance_cnt
  • total_mm
  • volt_min
  • total_weight
  • error_latch
  • scans_per_min
  • stat_latch
  • frequency2
  • frequency1
  • frequency3
  • Precipitation rate(precip_rate)
  • Precipitation, total(precip)
  • ptemp
  • temp3
  • weight3
  • weight2
  • temp1
  • weight1
  • Model derived 2-meter temperature(temp2)


Back To Table of Contents