Data Quality Reports for Session: 142900 User: pedro1jime Completed: 06/07/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D000210.1SGP/EBBR/E26 - Temperature from Left T/RH Probe Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000211.13SGP/EBBR/E26 - Left T/RH Probe Temperature Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000221.3SGP/EBBR/E26 - Right Aspirator Not Workingsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000221.6SGP/EBBR - EBBR E9 Anemometer Frozen, Wind Speed Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D000221.7SGP/EBBR/E26 - Anemometer Not Working, Wind Speed Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000225.1SGP/EBBR/26 - Low Battery Conditionsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000301.8SGP/EBBR - EBBR E9 Net Radiation Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D000301.9SGP/EBBR/E26 - Net Radiation Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000622.1SGP/EBBR/E26 - Reprocess Soil Moisture Off-Scalesgp30ebbrE26.b1, sgp15ebbrE26.b1
D000623.1SGP/EBBR/E26 - EBBR E26 Left Aspirator Not Workingsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.10SGP/EBBR/E26 - EBBR E26 All Data Incorrectsgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
D000623.11SGP/EBBR/E26 - All Data Incorrectsgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
D000623.2SGP/EBBR/E26 - All Data Incorrectsgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
D000623.3SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.5SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.6SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.7SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.8SGP/EBBR/E26 - All Data Incorrectsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D000623.9SGP/EBBR/E26 - All Data Incorrectsgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
D000627.10SGP/EBBR/E26 - Left Air Temperature Periodically Incorrectsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D000627.11SGP/EBBR/E26 - Reference Temperature Incorrectsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D000627.4SGP/EBBR/E26 - Electronics Problemsgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
D000627.6SGP/EBBR/E26 - Soil Heat Flow #5 Incorrectsgp30ebbrE26.b1, sgp15ebbrE26.b1
D000627.7SGP/EBBR/E26 - Soil Heat Flow #1 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D000627.8SGP/EBBR/E26 - Soil Heat Flow #2 Large Negativesgp30ebbrE26.b1, sgp15ebbrE26.b1
D000627.9SGP/EBBR/E26 - Left Air Temperature Incorrectsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D010213.12SGP/EBBR/E26 - Wind Speed Icedsgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
D010402.1SGP/EBBR/E9 - E9 EBBR Wind Direction Incorrectsgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
D010402.2SGP/EBBR/E9 - E9 EBBR Wind Speed Incorrectsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D010402.3SGP/EBBR/E9 - E9 EBBR Soil Heat Flow 1 Incorrectsgp30ebbrE9.b1, sgp15ebbrE9.b1
D010402.5SGP/EBBR/E9 - E9 EBBR Soil Heat Capacities Incorrectsgp30ebbrE9.b1
D010605.20SGP EBBR E26 - Data Suspect, Low Battery Voltagesgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D010605.22SGP EBBR E26 - All Data Incorrectsgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D010605.23SGP EBBR E26 - Soil Heat Flow #1 Incorrectsgp30ebbrE26.b1, sgp15ebbrE26.b1
D010605.24SGP EBBR E26 - Soil Heat Flow #2 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D010605.25SGP EBBR E26 - Soil Heat Flow #3 Incorrectsgp30ebbrE26.b1, sgp15ebbrE26.b1
D010723.3SGP EBBR E26 - Soil Moisture #1 Incorrectsgp30ebbrE26.b1, sgp15ebbrE26.b1
D010723.4SGP EBBR E26 - AEM Inbetween, Data Incorrectsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D010723.5SGP EBBR E26 - Soil Heat Flow #5 Incorrectsgp30ebbrE26.b1, sgp15ebbrE26.b1
D010723.7SGP EBBR E26 - Some Data Incorrectsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D010723.8SGP EBBR E26 - Some Data Incorrectsgp30ebbrE26.b1
D011127.25SGP EBBR E9 - E9 EBBR Data Incorect During 6 Month Checkssgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
D011127.34SGP EBBR E26 - Data Incorrect During 6 Month Checkssgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
D011206.1SGP EBBR E26 - Low Battery Voltagesgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
D011206.2SGP EBBR E26 - Battery Voltage Lowsgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
D011221.2SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrectsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D011221.3SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrectsgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
D011221.4SGP EBBR E9 - E9 EBBR Wind Speed Frozen Stoppedsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D011221.5SGP EBBR E9 - E9 EBBR Wind Direction Frozen In One Directionsgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
D011221.6SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrectsgp30ebbrE9.b1, sgp15ebbrE9.b1
D011221.8SGP EBBR E9 - E9 EBBR Gradients Incorrect During Sensor Replacementsgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
D020110.2SGP EBBR E9 - E9 EBBR Right Air Temperature Incorrectsgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
D020628.14SGP/EBBR/E9 - T/RH Checksgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D020628.6SGP/EBBR/E26 - 3-month Checksgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D020716.1SGP/EBBR/E9 - Annual calibration changeoutsgp30ebbrE9.b1, sgp15ebbrE9.b1
D020716.10SGP/EBBR/E9 - 6 Month Checkssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D020716.18SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D020716.2SGP/EBBR/E9 - Annual calibration changeoutsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D020717.2SGP/EBBR/E9 - Reprocess: Soil Temperature #5 Incorrectsgp30ebbrE9.b1
D020717.3SGP/EBBR/E9 - Measurements All Zerossgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.00, sgp5ebbrE9.b1
D020717.37SGP/EBBR/E26 - Measurements Zerosgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
D020717.38SGP/EBBR/E26 - Measurements Incorrectsgp30ebbrE26.b1
D020717.39SGP/EBBR/E26 - Multiplexer 2 Failure From High Temperaturesgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D020717.4SGP/EBBR/E9 - Humidity Probe Measurements Incorrectsgp30ebbrE9.b1, sgp5ebbrE9.b1
D020717.5SGP/EBBR/E9 - Right Humidity Suspectsgp5ebbrE9.b1, sgp30ebbrE9.b1
D020724.48SGP/EBBR/E26 - Annual Calibration Changeoutsgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1
D021113.1SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D021113.4SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D030110.27SGP/EBBR/E26 - Data Incorrect during 6 month checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030110.32SGP/EBBR/E9 - Data Incorrect during 6 month checkssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D030114.5SGP/EBBR/E9 - REPROCESS: Soil Temperature #5 Incorrectsgp30ebbrE9.b1
D030114.6SGP/EBBR/E9 - REPROCESS: Soil Heat Flow #4 Incorrectsgp30ebbrE9.b1
D030114.8SGP/EBBR/E9 - Net Rad data bad during dome replacementsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D030114.9SGP/EBBR/E9 - AEM Malfunctionsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D030117.26SGP/EBBR/E26 - Measurements zero following logger restartsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030117.27SGP/EBBR/E26 - Multiplexer Problemsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030117.28SGP/EBBR/E26 - Water in broken Net Radiometer Domesgp30ebbrE26.b1, sgp5ebbrE26.b1
D030117.29SGP/EBBR/E26 - Battery Voltage Lowsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030128.2SGP/EBBR/E26 - AEM Hungsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030128.3SGP/EBBR/E26 - Data zeros following logger restartsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030128.4SGP/EBBR/E26 - Left Air Temperature Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030514.8SGP/EBBR/E26 - E26 EBBR Soil Heat Flow #1 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D030711.6SGP/EBBR/E26 -Right Air Temperature Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030712.1SGP/EBBR/E9 - AEM Hung Inbetween Home Positionssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D030712.15SGP/EBBR/E9 - 6 Month Checkssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D030712.2SGP/EBBR/E9 - Soil Heat Flow #1 Incorrectsgp30ebbrE9.b1, sgp15ebbrE9.b1
D030712.23SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030712.3SGP/EBBR/E9 - Battery Voltage Lowsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D030728.4SGP/EBBR/E26 - Soil Heat Flow #5 Large Positivesgp15ebbrE26.b1, sgp30ebbrE26.b1
D030729.2SGP/EBBR/E9 - AEM Hung in home 30 position.sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D030919.11SGP/EBBR/E26 - Soil Storage Incorrect; Surface Fluxes Incorrectsgp30ebbrE26.b1
D030919.7SGP/EBBR/E9 - Water in Net Radiometer; Surface Fluxes are Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D031031.3SGP/EBBR/E9 - Measurements All Zerosgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D031103.1SGP/EBBR/E26 - AEM Home Signals Incorrect, Surface Fluxes Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031204.21SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031204.8SGP/EBBR/E9 - 6 Month Checkssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D031211.3SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031222.13SGP/EBBR/E9 - Net Radiometer Iced Over During Stormsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D031222.14SGP/EBBR/E9 - Wind Speed Sensor Frozen By Ice Stormsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D031222.24SGP/EBBR/E26 - Wind Speed Sensor Frozen By Ice Stormsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031222.25SGP/EBBR/E26 - Wind Direction Sensor Frozen By Ice Stormsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D040304.28SGP/EBBR/E26 - Wind Speed Frozen Stopped By Icesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D040304.29SGP/EBBR/E26 - Wind Direction Frozen Stopped By Icesgp30ebbrE26.b1, sgp5ebbrE26.b1
D040304.8SGP/EBBR/E9 - Wind Speed Frozen Stopped By Icesgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D040304.9SGP/EBBR/E9 - Wind Direction Frozen Stopped By Icesgp30ebbrE9.b1, sgp5ebbrE9.b1
D040723.2SGP/EBBR/E9 - net radiometer top dome broken, water in bottom domesgp30ebbrE9.b1, sgp5ebbrE9.b1
D040813.5SGP/EBBR/E26 - Soil Temperature #4 and Soil Heat Flow #4 Incorrectsgp30ebbrE26.b1
D041222.1SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D041222.10SGP/EBBR/E9 - 6 Month Checkssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D041222.18SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D041222.4SGP/EBBR/E26 - Low Battery Voltage - Many Measurements Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D041222.5SGP/EBBR/E26 - Most Measurements Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D050113.2SGP/EBBR/E9 - Wind Speed Threshhold Lowsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D050206.16SGP/EBBR/E26 - Wind Speed Frozen Stopped By Ice Stormsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D050206.8SGP/EBBR/E9 - Wind Speed Frozen Stopped By Ice Stormsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D050207.12SGP/EBBR/E26 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D050207.4SGP/EBBR/E9 - Wind Direction Frozen Stopped By Ice Stormsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D050211.1SGP/EBBR/E26 - Aging Pressure Sensor Output Changes With Supply Voltagesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D050215.14SGP/EBBR/E9 - Wind Direction Frozen Stopped By Icesgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D050215.15SGP/EBBR/E9 - Wind Speed Frozen Stopped By Icesgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D050324.3SGP/EBBR/E26 - Incorrect soil type coefficients usedsgp30ebbrE26.b1
D050601.2SGP/EBBR/E9 - Soil moisture too highsgp15ebbrE9.b1, sgp30ebbrE9.b1
D050719.15SGP/EBBR/E26 - Improved EBBR CR10 Programsgp30ebbrE26.b1
D050719.8SGP/EBBR/E9 - Improved EBBR CR10 Programsgp30ebbrE9.b1
D051104.1SGP/EBBR/E9 - Net Radiation Incorrect: Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D051106.22SGP/EBBR/E9 - Average Soil Heat Flux Incorrectsgp30ebbrE9.b1
D051106.30SGP/EBBR/E26 - Average Soil Heat Flux Incorrectsgp30ebbrE26.b1
D051112.6SGP/EBBR/E9 - metadata correctionssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D051112.9SGP/EBBR/E26 - metadata correctionssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D051215.2SGP/EBBR/E9 - Net Radiation, Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D051222.1SGP/EBBR/E26 - Data Suspect During Low Supply Voltagesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D060501.26SGP/EBBR/E26 - Measurements Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D060621.7SGP/EBBR/E9 - Wind Speed Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D061220.15SGP/EBBR/E26 - Wind Direction Dependency of Surface Fluxes and General Data Quality
Information
sgp30ebbrE26.b1
D061220.5SGP/EBBR/E9 - Wind Direction Dependency of Surface Fluxes and General Data Quality
Information
sgp30ebbrE9.b1
D071001.1SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensorsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D080102.2SGP/EBBR/E9 - Net Radiation Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D090313.11SGP/EBBR/E9 - Wind Speed Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D090313.8SGP/EBBR/E26 - Wind Speed Incorrectsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D091015.2SGP/EBBR/E26 - Low supply voltagesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D100521.2SGP/EBBR/E9 - Sensible and latent heat flux incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1
D101127.1SGP/EBBR/E9 - T/RH Probe Temperature Problem - Sensible and Latent Heat Fluxes Affectedsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D110105.4SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
D110830.2SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE9.b1
D931108.6SGP/EBBR/E9 - pressure calibrationsgp30ebbrE9.b1
D940211.1SGP/EBBR/E26 - Invalid data during Preventative Maintenancesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D940301.2SGP/EBBR/E26 - Winds, SM2 Invalid data 10/10/93 - 2/2/94sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D940301.6SGP/EBBR/E9 - Invalid wind speed frozen sensorsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D940329.1SGP/EBBR/E26 - Wind Direction Sensor Malfunctionsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D940329.3SGP/E9/EBBR - AEM Malfunctionsgp30ebbrE9.b1, sgp5ebbrE9.b1
D940503.1SGP/EBBR/E9 - AEM failuresgp30ebbrE9.b1
D940606.1SGP/EBBR/E26 - Wind Speed Malfunctionsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D940606.2SGP/EBBR/E26 - Wind Direction Sensor Failuresgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D940711.2SGP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor Failuresgp30ebbrE9.b1, sgp15ebbrE9.b1
D940818.1SGP/EBBR/E26 - Soil Moisture Sensor Malfunctionsgp15ebbrE26.b1, sgp30ebbrE26.b1
D940826.1SGP/EBBR/E9 - Malfunctioning Wind Dir Sensor, Incorrect SM2 Resultssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D940826.2SGP/EBBR/E9 - Reprocess: Soil Heat Flux Out of Rangesgp15ebbrE9.b1, sgp30ebbrE9.b1
D940830.7SGP/EBBR/E9 - Hail Damage to Net Radiometer and Wind Speed Sensorsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D941021.11SGP/EBBR/E26 - Net Radiometer Hemisphere Changessgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D941212.1SGP/EBBR/E26 - Wind Direction Sensor Affect on Soil Moisture 2sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D941221.1SGP/EBBR/E26 - T/RH Checksgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D950126.2SGP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Datasgp30ebbrE9.b1, sgp15ebbrE9.b1
D950308.2SGP/EBBR/E9 - Radiation Shield Problemsgp30ebbrE9.b1, sgp5ebbrE9.b1
D950308.3SGP/EBBR/E26 - Frozen Wind Speed Sensorsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D950626.10SGP/EBBR/E26 - Stopped Ventilation Fansgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D950626.11SGP/EBBR/E9 - Stopped Ventilation Fansgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D950626.12SGP/EBBR/E9 - Water in Net Radiometersgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D950626.14SGP/EBBR/E26 - Reprocess: Soil Heat Flow Sensor 1 Replacementsgp15ebbrE26.b1, sgp30ebbrE26.b1
D950626.19SGP/EBBR/E26 - Right Air Temperature Malfunctionsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D950626.5SGP/EBBR/E26 - Frozen Wind Speed Sensorsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D950626.6SGP/EBBR/E9 - Frozen Wind Speed Sensorsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D950626.8SBP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Datasgp15ebbrE9.b1, sgp30ebbrE9.b1
D950626.9SGP/EBBR/E26 - Frozen Wind Speed Sensorsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D950908.2SGP/EBBR/E26 - AEM not exchangingsgp30ebbrE26.b1, sgp5ebbrE26.b1
D950921.4SGP/EBBR/E26 - AEM replacementsgp30ebbrE26.b1, sgp5ebbrE26.b1
D951016.1SGP/EBBR/E26 - Battery Voltage Dropsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D951016.2SGP/EBBR/E26 - Net Radiometer Dome Puncturedsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D951020.1SGP/EBBR/E9 - 3-month Checksgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D951113.4SGP/EBBR/E26 - Right Tair Offscalesgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D951116.3SGP/EBBR/E26 - Wind Speed Cups Frozensgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D951116.5SGP/EBBR/E9 - AEM Exchange Stopped in Snow and Freezing Rainsgp30ebbrE9.b1
D951127.1SGP/EBBR/E9 - Annual calibration changeoutsgp30ebbrE9.b1, sgp5ebbrE9.b1
D960104.2SGP/EBBR/E26 - Wind Speed Cups Frozensgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D960104.8SGP/EBBR/E26 - Right Tair Offscalesgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D960119.3SGP/EBBR/E26 - Right tair Offscalesgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D960321.1SGP/EBBR/E9 - Wind Speed Cups Frozensgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D960409.1SGP/EBBR/E26 - Right Air Temperature Malfunctionsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D960501.4SGP/EBBR/E26 - Right Air Temp Malfunctionsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D960508.10SGP/EBBR/E26 - 3-month checksgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D960508.4SGP/EBBR/E9 - 3-month checksgp30ebbrE9.b1, sgp5ebbrE9.b1
D961122.10SGP/EBBR/E9 - Air Temperature Thermocouples Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D961122.12SGP/EBBR/E26 - Wind Direction Sensor Failuresgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D961122.13SGP/EBBR/E26 - Right Air Temperature Malfunctionsgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D961122.22SGP/EBBR/E9 - EBBR 3 Month Checks - 10 EFssgp15ebbrE9.b1, sgp5ebbrE9.b1, sgp30ebbrE9.b1
D961122.28SGP/EBBR/E26 - EBBR 3 Month Checks - 10 EFssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D961122.4SGP/EBBR/E26 - Annual Calibration Changeoutsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D961122.5SGP/EBBR/E26 - Wind Direction Sensor Failuresgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D970330.6SGP/EBBR/E26 - Wind Direction Sensor Failuresgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
D970623.2SGP/EBBR/E9 - Temperature Portion of T/RH Probesgp15ebbrE9.b1, sgp30ebbrE9.b1
D970627.2SGP/EBBR/E26 - Reprocess: E26 Soil Heat Flow Sensor 1 Replacementsgp15ebbrE26.b1, sgp30ebbrE26.b1
D971021.3SGP/EBBR/E9 - EBBR Biannual Checkssgp15ebbrE9.b1, sgp5ebbrE9.b1, sgp30ebbrE9.b1
D971021.9SGP/EBBR/E26 - EBBR Biannual Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D971027.8SGP/EBBR/E9 - Wind Direction Sensor Malfunctionsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D971027.9SGP/EBBR/E26 - Bad Datessgp30ebbrE26.b1
D980117.13SGP/EBBR/E9 - EBBR Frozen Wind Speedsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D980117.22SGP/EBBR/E26- EBBR Frozen Wind Speedsgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1
D980117.25SGP/EBBR/E9 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)sgp15ebbrE9.b1, sgp5ebbrE9.b1, sgp30ebbrE9.b1
D980117.31SGP/EBBR/E9 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affectedsgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D980117.33SGP/EBBR/E26 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affectedsgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
D980117.5SGP/EBBR/E26 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D980410.5SGP/EBBR/E9 - Wind Speed Sensor Frozensgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
D980416.10SGP/EBBR/E9 - 3-Month Checksgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
D980416.18SGP/EBBR/E26 - 3-Month Checksgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D980507.5SGP/EBBR/E26 - Character In EBBR E26, 30 Minute Datasgp30ebbrE26.b1
D980529.17SGP/EBBR/E26 - Six Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D980529.8SGP/EBBR/E9 - Six Month Checkssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
D990127.12SGP/EBBR/E9 - Wind Direction Data Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
D990127.31SGP/EBBR/E26 - Wind Direction Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D990127.42SGP/EBBR/E26 - Wind Speed Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D990127.43SGP/EBBR - EBBR E26 Wind Speed Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D990127.7SGP/EBBR/E26 - Battery Voltage Low, Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D990127.8SGP/EBBR/E9 - EBBR E9 Net Radiometer Dome Broken, Flux Data Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
D990128.6SGP/EBBR/E9 - Wind Speed Data Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
D990128.7SGP/EBBR/E9 - Wind Speed Data Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
D990129.5SGP/EBBR/E26 - Battery Voltage Lowsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D990409.6SGP/EBBR/E26 - Calibration Changeoutsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D990421.2SGP/EBBR/E26 - Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgpebbrE26.00, sgp5ebbrE26.00
D990622.5SGP/EBBR/E9 - Wind Speed Incorrectsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
D990622.6SGP/EBBR/E26 - Battery Wire Problem Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D990622.7SGP/EBBR/E26 - Battery Wire Problem Causes Questionable Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
D990623.1SGP/EBBR/E9 - Right Aspirator Not Workingsgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1


DQRID : D000210.1
Start DateStart TimeEnd DateEnd Time
06/11/1999000006/29/19992145
Subject:
SGP/EBBR/E26 - Temperature from Left T/RH Probe Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The temperature from the left T/RH probe went offscale frequently.  This
temperature is used in the calculation of the vapor pressure.  Therefore,
top and bottom Thum measurements, left Thum, top and bottom vapor pressure 
measurements, vapor pressure gradients, and the resulting latent and 
sensible heat fluxes and bowen ratio were frequently incorrect for the 
period stated.
Measurements:sgp30ebbrE26.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top

sgp15ebbrE26.b1:
  • temp_trh_left_rr

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D000211.13
Start DateStart TimeEnd DateEnd Time
06/11/1999000006/29/19992145
Subject:
SGP/EBBR/E26 - Left T/RH Probe Temperature Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Left T/RH probe temperature is frequently offscale during the period.
Examine the data (compare with the the T/RH right temperature) to determine
which times are incorrect.  Replacement of the probe on 29 June 1999 
solved the problem.

Affected data are:

5 minute:  tair_bot, tair_top
15 minute: tair_l
30 minute: tair_bot, tair_top, e, h, bowen
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D000221.3
Start DateStart TimeEnd DateEnd Time
01/08/2000023001/27/20001700
Subject:
SGP/EBBR/E26 - Right Aspirator Not Working
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The right aspirator fan did not work during the period.

The following values were therefore incorrect:

5 minute:  tair_top, tair_bot, thum_top. thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_l, mv_hum_l, tair_l
30 minute: tair_top, tair_bot, thum_top. thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, e, h, bowen
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D000221.6
Start DateStart TimeEnd DateEnd Time
12/18/1999080012/18/19991930
Subject:
SGP/EBBR - EBBR E9 Anemometer Frozen, Wind Speed Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The anemometer cups were frozen stalled.

The following values were therefore incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D000221.7
Start DateStart TimeEnd DateEnd Time
09/25/1999063510/07/19991620
Subject:
SGP/EBBR/E26 - Anemometer Not Working, Wind Speed Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The anemometer was not working during this period.

The following values were therefore incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D000225.1
Start DateStart TimeEnd DateEnd Time
07/27/1999061508/12/19991600
Subject:
SGP/EBBR/26 - Low Battery Condition
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
When battery voltage was less than 10.4 V DC during this period, all
data should be considered to be incorrect.  The cause of the problem
was a broken trace on J-panel #3.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time


Back To Table of Contents

DQRID : D000301.8
Start DateStart TimeEnd DateEnd Time
09/28/1999023009/30/19991500
Subject:
SGP/EBBR - EBBR E9 Net Radiation Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000301.9
Start DateStart TimeEnd DateEnd Time
09/25/1999070010/07/19991700
Subject:
SGP/EBBR/E26 - Net Radiation Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE26.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • net_radiation_mv

sgp5ebbrE26.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000622.1
Start DateStart TimeEnd DateEnd Time
07/17/1996000004/01/19991410
Subject:
SGP/EBBR/E26 - Reprocess Soil Moisture Off-Scale
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
During numerous periods within the days listed above, individual soil
moisture probes indicate small positive or else negative values when
soil moisture is high (greater than 35%).  This situation has occured
since the present EBBR unit was installed on 17 July 1996.  The cause
of the problem is inadequate range in the calibration curve equation.
Cement soil is somewhat unique amongst the EBBR sites, as the soil is
very sandy and porous; it can hold a larger amount of water per volume
than the other soils.  This high a soil moisture cannot be obtained with
the calibration soil used by REBS.  Therefore, the soil moisture equations
need to be manipulated to allow larger soil moistures to be calculated.
Much of the data from January 1998 is corrupted by this problem,
making changes in the equations prudent.

The soil moisture data must be inspected by the data user to see when
soil moisture values for one or more probes is inconsistent with the
others.

Recalculation of ave_shf, e, and h must be made using only the soil
moisture sets with correct soil moisture values.
Affected data values are (# for probe number):

15 minute: rr_sm#

30 minute: sm#, c_shf#, cs#, ces#, g#, ave_shf, e, h

Sensible, latent, and soil heat fluxes can be recalculated using the soil
probe sets that provide correct data.  For example, if soil moisture 2 is
incorrect,

ave_shf = (g1 + g3 + g4 + g5)/4

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),


If soil moisture 2 and 4 are incorrect,

ave_shf = (g1 + g3 + g5)/3

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),


If soil moisture 2, 4, and 5 are incorrect,

ave_shf = (g1 + g3)/2

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),

etc.

On 5 May 1998 at 1815 GMT a calibration coefficient was changed in the CR10
program as a result of a BCR by the mentor.  This coefficient has helped
reduce the least severe problems but has not eliminated problems from
large negative soil moistures measured even once during the integration
period.  However, now the incorrect average soil heat flow, latent heat
flux, and sensible heat flux are so large, negative or positive, that they
cannot be mistaken as being correct. 

The EBBR unit was replaced with a recalibrated system on 1 April 1999.
The previous unit experienced soil moisture problems the entire time
(almost 3 years) that the system was installed because of the inadequacy
of the soil moisture sensor calibrations.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_heat_capacity_4
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_moisture_1_r
  • soil_moisture_5_r
  • soil_moisture_3_r
  • soil_moisture_2_r
  • soil_moisture_4_r


Back To Table of Contents

DQRID : D000623.1
Start DateStart TimeEnd DateEnd Time
04/28/2000204505/04/20001500
Subject:
SGP/EBBR/E26 - EBBR E26 Left Aspirator Not Working
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The data is suspect because of inadequate aspiration for the sensors
in the left aspirated radiation shield.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D000623.10
Start DateStart TimeEnd DateEnd Time
02/22/2000133002/22/20001500
Subject:
SGP/EBBR/E26 - EBBR E26 All Data Incorrect
DataStreams:sgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
All data was incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000623.11
Start DateStart TimeEnd DateEnd Time
02/22/2000230002/23/20000030
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
All data wqas incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000623.2
Start DateStart TimeEnd DateEnd Time
04/06/2000163004/06/20001700
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
Description:
Data was incorrect because of Preventative Maintenance activities.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000623.3
Start DateStart TimeEnd DateEnd Time
04/13/2000121504/13/20001415
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage below about 10.5 volts DC caused a number of the
EBBR sensors to not measure correctly.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • home_signal_30
  • soil_heat_capacity_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_15
  • surface_soil_heat_flux_2
  • soil_temp_5
  • surface_soil_heat_flux_1
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • soil_heat_flow_4
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_1_mv

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.5
Start DateStart TimeEnd DateEnd Time
04/13/2000174504/13/20001800
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage less than 10.5 volts DC causes some
sensors to measure incorrectly.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • home_signal_30
  • soil_heat_capacity_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_15
  • surface_soil_heat_flux_2
  • soil_temp_5
  • surface_soil_heat_flux_1
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • soil_heat_flow_4
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_heat_flow_1_mv
  • soil_temp_1_rr

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.6
Start DateStart TimeEnd DateEnd Time
04/14/2000061504/14/20001530
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage less than 10.5 volts DC causes
some sensors to measure incorrectly.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • home_signal_30
  • soil_heat_capacity_1
  • home_signal_15
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • soil_temp_5
  • surface_soil_heat_flux_1
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_1_mv

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.7
Start DateStart TimeEnd DateEnd Time
04/16/2000084504/16/20001500
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage less than 10.5 volts DC causes
some sensors to make incorrect measurements.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • home_signal_30
  • soil_heat_capacity_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • soil_heat_flow_4
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_1_mv

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.8
Start DateStart TimeEnd DateEnd Time
03/24/2000000003/24/20000030
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
All data was incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000623.9
Start DateStart TimeEnd DateEnd Time
03/15/2000103003/15/20001430
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
All data was incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000627.10
Start DateStart TimeEnd DateEnd Time
02/26/2000153004/20/20001450
Subject:
SGP/EBBR/E26 - Left Air Temperature Periodically Incorrect
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
Left air temperature periodically was incorrect, causing the indicated measurements
to be incorrect.  The user will need to inspect the data to see when the left air
temperature was incorrect (compare left with right air temperature or with the
humidity probe temperature).
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D000627.11
Start DateStart TimeEnd DateEnd Time
03/07/2000090004/20/20001450
Subject:
SGP/EBBR/E26 - Reference Temperature Incorrect
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The reference temperature sensor did not work during the indicated period,
causing the indicated measurements to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_reference
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left
  • temp_reference_rr

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom
  • temp_reference


Back To Table of Contents

DQRID : D000627.4
Start DateStart TimeEnd DateEnd Time
03/24/2000010004/06/20001730
Subject:
SGP/EBBR/E26 - Electronics Problem
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
Description:
Incorrect home signal indicates an electronic problem that affected the indicated
measurements; this may have been a multiplexer #2 problem as all sensors affected 
are connected to that multiplexer and no sensors on multiplexer #1 were affected.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_air_top
  • Radiation, net(net_radiation)
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • bowen_ratio
  • home_signal_30
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • temp_air_left
  • soil_heat_flow_2_mv
  • home_signal
  • temp_air_right
  • soil_heat_flow_3_mv
  • soil_heat_flow_1_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • home_signal
  • temp_air_top
  • temp_air_bottom
  • temp_reference
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000627.6
Start DateStart TimeEnd DateEnd Time
04/06/2000180006/15/20001600
Subject:
SGP/EBBR/E26 - Soil Heat Flow #5 Incorrect
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
Soil Heat Flow #5 was incorrect, causing the indicated measurements to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D000627.7
Start DateStart TimeEnd DateEnd Time
12/16/1999003003/07/20001455
Subject:
SGP/EBBR/E26 - Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #1 was incorrect, causing the indicated measurements to be incorrect.
A broken sensor wire was at fault.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000627.8
Start DateStart TimeEnd DateEnd Time
03/03/2000060003/07/20001455
Subject:
SGP/EBBR/E26 - Soil Heat Flow #2 Large Negative
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
Soil Heat Flow #2 was large negative and incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • corr_soil_heat_flow_2
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_2_mv


Back To Table of Contents

DQRID : D000627.9
Start DateStart TimeEnd DateEnd Time
02/25/2000214502/26/20001130
Subject:
SGP/EBBR/E26 - Left Air Temperature Incorrect
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
Incorrect left air temperature caused the indicated measurements to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D010213.12
Start DateStart TimeEnd DateEnd Time
12/25/2000060012/28/20001145
Subject:
SGP/EBBR/E26 - Wind Speed Iced
DataStreams:sgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
The anemometer was frozen stopped by freezing rain.  Indicated data are incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D010402.1
Start DateStart TimeEnd DateEnd Time
12/11/2000000012/11/20001331
Subject:
SGP/EBBR/E9 - E9 EBBR Wind Direction Incorrect
DataStreams:sgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
The wind direction vane was frozen in one direction by icing during the indicated period.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE9.b1:
  • wdir_vec_mean_mv

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D010402.2
Start DateStart TimeEnd DateEnd Time
12/10/2000201512/15/20001631
Subject:
SGP/EBBR/E9 - E9 EBBR Wind Speed Incorrect
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
The wind speed sensor cups were frozen in place by icing.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D010402.3
Start DateStart TimeEnd DateEnd Time
12/18/2000153002/13/20011546
Subject:
SGP/EBBR/E9 - E9 EBBR Soil Heat Flow 1 Incorrect
DataStreams:sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
Soil Heat flow sensor #1 produced measurements that were large negative during the 
indicated period.  This was the result of sensor failure.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_1

sgp15ebbrE9.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D010402.5
Start DateStart TimeEnd DateEnd Time
03/13/2000160003/13/20001601
Subject:
SGP/EBBR/E9 - E9 EBBR Soil Heat Capacities Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Heat Capacities were out-of-range during this period, as reported by
the datalogger. The cause of this is unknown.

Actual values used in the computations of fluxes were okay, as the fluxes were not 
affected.
Measurements:sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5


Back To Table of Contents

DQRID : D010605.20
Start DateStart TimeEnd DateEnd Time
03/03/2000060003/07/20000901
03/24/2000010004/06/20001701
06/19/2000083006/19/20001431
06/19/2000163006/19/20001731
06/19/2000190006/19/20001901
06/20/2000143006/20/20002201
06/30/2000094506/30/20001346
07/02/2000093007/02/20001601
07/03/2000123007/03/20001316
Subject:
SGP EBBR E26 - Data Suspect, Low Battery Voltage
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
The data measurements are suspect because of low battery voltage.
Some measurements may be correct, but most are probably incorrect.
Large home signals indicate very low battery voltage is present.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D010605.22
Start DateStart TimeEnd DateEnd Time
09/06/2000223009/06/20002231
09/10/2000143009/10/20001431
10/16/2000150010/16/20001501
10/23/2000190010/23/20001901
10/26/2000153010/26/20001601
10/27/2000143010/27/20001501
01/03/2001153001/03/20011631
01/02/2001160001/02/20012201
Subject:
SGP EBBR E26 - All Data Incorrect
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
All data was incorrect during these periods for unknown reasons.
However, this tends to happen during preventative maintenance
visits if sensors have to be changed out or tested and the 
datalogger program is reloaded, or if the battery voltage is low.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D010605.23
Start DateStart TimeEnd DateEnd Time
12/16/1999170003/03/20000931
Subject:
SGP EBBR E26 - Soil Heat Flow #1 Incorrect
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
Soil Heat Flow #1 was incorrect because of a bad electronic
connection.  Average surface heat flow, sensible heat flux, and
latent heat flux are incorrect as a result; these can be re-calculated 
by using the remaining correct soil heat flows.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D010605.24
Start DateStart TimeEnd DateEnd Time
02/18/2000033002/19/20001131
03/04/2000150003/07/20000901
Subject:
SGP EBBR E26 - Soil Heat Flow #2 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #2 was incorrect.  Average soil heat flow, 
sensible heat flux, and latent heat flux were therefore also
incorrect; these can be re-calculated from the remaining 
correct soil heat flows.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • corr_soil_heat_flow_2
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_2_mv


Back To Table of Contents

DQRID : D010605.25
Start DateStart TimeEnd DateEnd Time
11/05/2000190011/16/20001601
11/30/2000160012/03/20000731
12/14/2000160012/16/20000301
06/15/2000150006/19/20002201
Subject:
SGP EBBR E26 - Soil Heat Flow #3 Incorrect
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
Soil heat Flow #3 was incorrect (large negative).  Therefore
average soil heat flow, sensible heat flux, and latent heat flux were
also incorrect; these can be re-calculated using the remaining
correct soil heat flows.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D010723.3
Start DateStart TimeEnd DateEnd Time
04/06/2000173002/08/20011546
Subject:
SGP EBBR E26 - Soil Moisture #1 Incorrect
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
Soil Moisture #1 was a constant 33.7 and was incorrect.

Latent and Sensible Heat fluxes were normally minimally affected.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_capacity_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • soil_moisture_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_moisture_1_r
  • soil_moisture_1_rr


Back To Table of Contents

DQRID : D010723.4
Start DateStart TimeEnd DateEnd Time
08/23/2000034508/23/20000401
Subject:
SGP EBBR E26 - AEM Inbetween, Data Incorrect
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
While the AEM was inbetween the correct measurement positions the measurements from the 
two levels were incorrect.

The sensible and latent heat fluxes and Bowen ratio were therefore incorrect also.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D010723.5
Start DateStart TimeEnd DateEnd Time
04/15/2000153002/22/20011535
Subject:
SGP EBBR E26 - Soil Heat Flow #5 Incorrect
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
Soil Heat Flow #5 was large negative during this period.

Therefore, calculated average soil heat flow, latent heat flux, and sensible heat flux 
were incorrect.  These measurements can be recalculated from the use of measurements from 
only soil heat flow sensors #1-4.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D010723.7
Start DateStart TimeEnd DateEnd Time
10/21/2000213010/21/20002131
Subject:
SGP EBBR E26 - Some Data Incorrect
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The reference temperature sensor malfunctioned, causing all associated measurements to be 
incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • temp_air_top
  • energy_storage_change_5
  • temp_trh_bottom
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • temp_trh_top
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • soil_temp_5
  • surface_soil_heat_flux_1
  • soil_temp_4
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_reference

sgp15ebbrE26.b1:
  • soil_temp_4_rr
  • soil_temp_5_rr
  • temp_reference_rr
  • temp_air_left
  • soil_temp_3_rr
  • soil_temp_2_rr
  • temp_air_right
  • soil_temp_1_rr

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • vapor_pressure_top
  • temp_reference
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D010723.8
Start DateStart TimeEnd DateEnd Time
09/10/2000150009/10/20001501
11/02/2000160011/02/20001601
01/03/2001170001/03/20011701
Subject:
SGP EBBR E26 - Some Data Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
Since soil temperature was not available for the previous half hour, soil energy storage 
could not be calculated properly for the indicated period.  The individual soil heat 
storage from the five soil sets, average soil heat flow, sensible heat flux, and latent heat 
flux are therefore incorrect.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • energy_storage_change_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4


Back To Table of Contents

DQRID : D011127.25
Start DateStart TimeEnd DateEnd Time
05/22/2001150005/22/20011536
04/12/2001180004/12/20011846
10/23/2001151010/23/20011701
Subject:
SGP EBBR E9 - E9 EBBR Data Incorect During 6 Month Checks
DataStreams:sgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE9.b1:
  • Barometric Pressure(atmos_pressure)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_trh_top
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • vapor_pressure_bottom
  • soil_heat_flow_4
  • soil_heat_flow_3
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • soil_temp_4
  • soil_temp_5
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Radiation, net(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_moisture_1
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_top

sgp15ebbrE9.b1:
  • soil_moisture_4_rr
  • soil_temp_3_rr
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_heat_flow_1_mv
  • soil_temp_5_rr
  • soil_temp_1_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • net_radiation_mv
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • rh_left_mv
  • soil_moisture_3_rr
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • atmos_pressure_mv
  • rh_right_mv
  • wdir_vec_mean_mv
  • temp_trh_left_rr
  • soil_moisture_1_r
  • soil_moisture_2_r
  • soil_moisture_5_rr
  • soil_moisture_2_rr
  • soil_moisture_3_r
  • soil_moisture_1_rr
  • soil_moisture_4_r
  • soil_moisture_5_r
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • temp_reference
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_top_fraction
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Barometric Pressure(atmos_pressure)
  • Wind speed vector mean(wspd_vec_mean)
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_bottom
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • Radiation, net(net_radiation)
  • wdir_vec_std


Back To Table of Contents

DQRID : D011127.34
Start DateStart TimeEnd DateEnd Time
04/05/2001141504/05/20011546
10/16/2001175010/16/20011921
Subject:
SGP EBBR E26 - Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D011206.1
Start DateStart TimeEnd DateEnd Time
09/14/2000113003/31/20012356
Subject:
SGP EBBR E26 - Low Battery Voltage
DataStreams:sgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
During the indicated the period the battery voltage often dropped 
to 10.4 volts or below.  At voltages less than 10.5 volts none of
the selected measurements can be considered to be correct.  The battery
charging capacity was insufficient to maintain voltage at night.

If the battery voltage is less than 10.5 volts (see battery voltage in the
15 minute data files), do not use the data.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D011206.2
Start DateStart TimeEnd DateEnd Time
04/01/2001000008/23/20011530
Subject:
SGP EBBR E26 - Battery Voltage Low
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
Description:
The battery voltage often dropped below 10.5 volts. 

All data for voltages below 10.5 volts should be considered to be incorrect.

See the 15 minute data files, which contain the battery voltage, to 
determine when the data was incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D011221.2
Start DateStart TimeEnd DateEnd Time
01/01/2001000001/03/20011901
02/22/2001203102/22/20012301
02/23/2001054502/25/20011201
02/28/2001201503/11/20010831
03/20/2001014503/29/20011601
02/09/2001061502/11/20011701
01/20/2001091502/09/20010001
Subject:
SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrect
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
A worn AEM belt caused the AEM to hang frequently.
Gradient measurements, sensible heat flux, latent heat flux,
and Bowen ratio are incorrect during the indicated periods.

The AEM hung on 2/9/01 because of icing from an ice storm.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D011221.3
Start DateStart TimeEnd DateEnd Time
04/08/2001131504/09/20010931
04/23/2001191504/24/20010031
04/10/2001154504/10/20011831
04/12/2001174504/12/20011901
04/24/2001124504/25/20010131
04/25/2001121504/26/20010501
04/29/2001000004/29/20010201
04/29/2001074504/29/20010801
04/29/2001100005/08/20011501
04/03/2001194504/03/20012331
Subject:
SGP EBBR E9 - E9 EBBR AEM Hung, Data Incorrect
DataStreams:sgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
The AEM belt was worn and the AEM hung frequently.
Gradients, sensible heat flux, latent heat flux,
and Bowen ratio were incorrect during the indicated period.

The AEM was replaced during the recalibration changeout
on 5/11/01.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D011221.4
Start DateStart TimeEnd DateEnd Time
01/28/2001053001/29/20012031
02/09/2001043002/11/20011531
02/14/2001173502/16/20011831
Subject:
SGP EBBR E9 - E9 EBBR Wind Speed Frozen Stopped
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stop.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D011221.5
Start DateStart TimeEnd DateEnd Time
01/28/2001080001/29/20011701
02/14/2001173502/16/20011831
02/09/2001043002/10/20011801
Subject:
SGP EBBR E9 - E9 EBBR Wind Direction Frozen In One Direction
DataStreams:sgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
An ice storm froze the wind direction sensor in one postion.
Th indicated measurements are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE9.b1:
  • wdir_vec_mean_mv

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D011221.6
Start DateStart TimeEnd DateEnd Time
05/15/2001231512/14/20012356
Subject:
SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrect
DataStreams:sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
Soil moisture probe #5 in the recalibrated unit installed
on 5/11/01 has not been working all of the time.  At times
the measurement has been very large and incorrect.  The
indicated measurements are incorrect at those times.  The
data must be inspected to determine the times that 
have incorrect data.  The sensible and latent heat fluxes can
be recalculated by using soil sets 1, 2, 3, and 4 only in a 
recalculation of the energy budget.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_temp_5
  • energy_storage_change_5

sgp15ebbrE9.b1:
  • soil_temp_5_rr


Back To Table of Contents

DQRID : D011221.8
Start DateStart TimeEnd DateEnd Time
07/19/2001150007/19/20011631
Subject:
SGP EBBR E9 - E9 EBBR Gradients Incorrect During Sensor Replacement
DataStreams:sgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
During the replacement of the right air temperature
probe, all gradient measurements were incorrect.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D020110.2
Start DateStart TimeEnd DateEnd Time
07/15/2001083007/15/20012216
07/16/2001053007/16/20011946
07/14/2001023007/14/20012016
07/17/2001130007/17/20011316
07/18/2001123007/18/20011431
07/19/2001071507/19/20011616
Subject:
SGP EBBR E9 - E9 EBBR Right Air Temperature Incorrect
DataStreams:sgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
The right air temperature probe measurements were
incorrect during these periods.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • temp_air_right

sgp5ebbrE9.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D020628.14
Start DateStart TimeEnd DateEnd Time
11/14/1994182011/14/19942000
Subject:
SGP/EBBR/E9 - T/RH Check
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h


5 minute:  1820, 1825, 1830, 1835, 1840, 1845, 1850, 1855, 1900,
           1905, 1910, 1915, 1920, 1925, 1930, 1935, 1940, 1945
15 minute: 1830, 1845, 1900, 1915, 1930, 1945
30 minute: 1830, 1900, 1930, 2000


(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D020628.6
Start DateStart TimeEnd DateEnd Time
10/13/1995140010/13/19951700
Subject:
SGP/EBBR/E26 - 3-month Check
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D020716.1
Start DateStart TimeEnd DateEnd Time
11/15/1995210011/25/19950000
Subject:
SGP/EBBR/E9 - Annual calibration changeout
DataStreams:sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
On November 15, 1995 the changeout for annual calibration occurred at E9,
Ashton, KS.  The soil moisture sensors were shipped wet from the vendor 
and did not stabilize until 25 November 1995.  The following data should 
be considered incorrect until 25 November 1995:

15 minute:  rr_sm1, rr_sm2, rr_sm3, rr_sm4, rr_sm5

30 minute:  h, e, ave_shf, shf1, shf2, shf3, shf4, shf5, sm1, sm2, sm3,
            sm4, sm5, cs1, cs2, cs3, cs4, cs5, ces1, ces2, ces3, ces4,
            g1, g2, g3, g4, g5.
Measurements:sgp30ebbrE9.b1:
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_1
  • energy_storage_change_5
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • soil_moisture_1
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4

sgp15ebbrE9.b1:
  • soil_moisture_5_rr
  • soil_moisture_2_rr
  • soil_moisture_4_rr
  • soil_moisture_1_rr
  • soil_moisture_3_rr


Back To Table of Contents

DQRID : D020716.10
Start DateStart TimeEnd DateEnd Time
05/09/2002160005/09/20021631
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction

sgp15ebbrE9.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D020716.18
Start DateStart TimeEnd DateEnd Time
05/02/2002150005/02/20021531
Subject:
SGP/EBBR/E26 - 6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D020716.2
Start DateStart TimeEnd DateEnd Time
11/15/1995210011/16/19951700
Subject:
SGP/EBBR/E9 - Annual calibration changeout
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
On November 15, 1995 the changeout for annual calibration occurred at E9,
Ashton, KS.  After installation of the new SEBS unit, RH output was zero.  
The next day site operations personnel found that the RH probe cable 
connections were loose.  RH returned to normal after the connections were 
tightened at 1700 GMT on 16 November 1995.  During the period of time that 
the connections were not made, the following data values are incorrect: 

5 minute:  hum_top, hum_bot, vp_top, vp_bot

15 minute: mv_hum_r, mv_hum_l

30 minute: hum_top, hum_bot, vp_top, vp_bot.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • rh_top_fraction

sgp15ebbrE9.b1:
  • rh_left_mv
  • rh_right_mv

sgp5ebbrE9.b1:
  • vapor_pressure_bottom
  • rh_top_fraction
  • vapor_pressure_top
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D020717.2
Start DateStart TimeEnd DateEnd Time
12/15/2001000006/30/20022356
Subject:
SGP/EBBR/E9 - Reprocess: Soil Temperature #5 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil temperature # 5 was incorrect most of the time, leading to incorrect surface heat 
flow, latent heat flux and sensible heat flux.  The heat fluxes can be recalculated by using 
soil sets 1-4 as follows:

ave_shf = (g1 + g2 + g3 + g4)/4
e = -(q + ave_shf)/(1 + bowen)
h = -(q + e + ave_shf)
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_temp_5
  • energy_storage_change_5


Back To Table of Contents

DQRID : D020717.3
Start DateStart TimeEnd DateEnd Time
03/28/2002160003/28/20021601
06/04/2002150006/04/20021501
Subject:
SGP/EBBR/E9 - Measurements All Zeros
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.00, sgp5ebbrE9.b1
Description:
The measurements were all zeros at the indicated times.  This occurs after a CR10 program 
restart, which sometimes happens after some servicing of the EBBR is performed.
Measurements:sgp30ebbrE9.b1:
  • Barometric Pressure(atmos_pressure)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_trh_top
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • vapor_pressure_bottom
  • soil_heat_flow_3
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • home_signal_30
  • soil_temp_4
  • soil_temp_5
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Radiation, net(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_moisture_1
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_top

sgp5ebbrE9.00:
  • Raw data stream - documentation not supported

sgp15ebbrE9.b1:
  • soil_moisture_4_rr
  • soil_temp_3_rr
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_heat_flow_1_mv
  • soil_temp_5_rr
  • soil_temp_1_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • net_radiation_mv
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • rh_left_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • atmos_pressure_mv
  • rh_right_mv
  • wdir_vec_mean_mv
  • temp_trh_left_rr
  • soil_moisture_5_rr
  • soil_moisture_2_rr
  • soil_moisture_1_rr
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • temp_reference
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_top_fraction
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • Wind speed vector mean(wspd_vec_mean)
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_bottom
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • vapor_pressure_bottom
  • Radiation, net(net_radiation)
  • wdir_vec_std


Back To Table of Contents

DQRID : D020717.37
Start DateStart TimeEnd DateEnd Time
05/30/2002150005/30/20021501
Subject:
SGP/EBBR/E26 - Measurements Zero
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
Description:
The measurements are often zero after a CR10 datalogger restart, as occurred here.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D020717.38
Start DateStart TimeEnd DateEnd Time
05/30/2002153005/30/20021531
Subject:
SGP/EBBR/E26 - Measurements Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
Change of energy storage (CES) measurements (calculated from the change of soil 
temperature with time) are sometimes incorrect after a CR10 program restart because the beginning 
measurement of the averaging period is zero.  

Average soil heat flow, sensible heat flux, and latent heat flux were affected and cannot 
be recalculated.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • energy_storage_change_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4


Back To Table of Contents

DQRID : D020717.39
Start DateStart TimeEnd DateEnd Time
06/01/2002211506/30/20022356
Subject:
SGP/EBBR/E26 - Multiplexer 2 Failure From High Temperature
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
Multiplexer 2 is failing during times of control box temperatures above 29 degrees C.  The 
failure begins in the last channel and progresses to lower channels as the temperature 
increases.  It has not yet been determined whether the failure is in the relays or a solid 
state component of the multiplexer.  This condition is probably due to the aging of the 
device and the millions of cycles that this 10 year old device has made.  More failures 
of this sort may occur in the future.  A cure is being sought aside from replacement of 
the multiplexers to prevent the problem.

The indicated measurements need to be inspected to determine which ones are usable.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • soil_heat_flow_3
  • soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • soil_heat_flow_4
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D020717.4
Start DateStart TimeEnd DateEnd Time
03/28/2002161503/28/20021801
Subject:
SGP/EBBR/E9 - Humidity Probe Measurements Incorrect
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The temperature and humidity measurements from both T/RH probes were incorrect during 
changeout of the right probe.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • rh_top_fraction

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_trh_bottom


Back To Table of Contents

DQRID : D020717.5
Start DateStart TimeEnd DateEnd Time
01/30/2002101507/16/20021630
Subject:
SGP/EBBR/E9 - Right Humidity Suspect
DataStreams:sgp5ebbrE9.b1, sgp30ebbrE9.b1
Description:
The Right Humidity measurement was normally incorrect, although it is often difficult to 
determine it by looking at the measurement.  The measurements float around, sometimes 
being too large and sometimes being too small, through most of the day, particularly for the 
hour before sunset through the hour after sunrise.  Great care and comparison with 
surrounding EBBR sites would be needed to be able to use any of the latent and sensible heat 
flux measurements from E9 for this period. 

Another DQPR has been issued to fix this problem, which has eluded repair efforts so far.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_top_fraction

sgp5ebbrE9.b1:
  • vapor_pressure_bottom
  • rh_top_fraction
  • vapor_pressure_top
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D020724.48
Start DateStart TimeEnd DateEnd Time
07/17/1996140007/17/19961430
Subject:
SGP/EBBR/E26 - Annual Calibration Changeout
DataStreams:sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
On 16 November 1996 the EBBR changeout for annual calibration occurred at 
E26, Cement, OK.  SEBS unit 2 was removed and unit 8 was installed.  
Data for half hours 1400 and 1430 GMT on 17 November is 
incorrect; 3 month calibration checks were being performed.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time


Back To Table of Contents

DQRID : D021113.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE2.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_4

sgp30ebbrE26.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE22.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE18.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE4.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE15.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE19.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1

sgp30ebbrE8.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1


Back To Table of Contents

DQRID : D021113.4
Start DateStart TimeEnd DateEnd Time
12/01/1993120006/18/20031159
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.
   
This does not affect the data quality.

(NOTE: The actual begin date of some of these data streams
 is as early as 7/4/93.  This DQR applies to all 30m EBBR
 data.)
Measurements:sgp30ebbrE26.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE4.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE15.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE22.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE8.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1


Back To Table of Contents

DQRID : D030110.27
Start DateStart TimeEnd DateEnd Time
11/27/2002160511/27/20021635
Subject:
SGP/EBBR/E26 - Data Incorrect during 6 month checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D030110.32
Start DateStart TimeEnd DateEnd Time
11/19/2002163511/19/20021735
Subject:
SGP/EBBR/E9 - Data Incorrect during 6 month checks
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction

sgp15ebbrE9.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_trh_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D030114.5
Start DateStart TimeEnd DateEnd Time
07/01/2002000007/16/20021530
Subject:
SGP/EBBR/E9 - REPROCESS: Soil Temperature #5 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Temperature #5 was intermittently incorrect.
The cause is unknown. The indicated measurements 
that are calculated using soil temperature are 
also incorrect.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_temp_5
  • energy_storage_change_5


Back To Table of Contents

DQRID : D030114.6
Start DateStart TimeEnd DateEnd Time
07/16/2002150007/16/20021529
Subject:
SGP/EBBR/E9 - REPROCESS: Soil Heat Flow #4 Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
Soil Heat Flow #4 was incorrect during these periods as a 
consequence of the repair of Soil Temperature #5.  
See below for a work-around.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_4
  • surface_soil_heat_flux_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • corr_soil_heat_flow_4


Back To Table of Contents

DQRID : D030114.8
Start DateStart TimeEnd DateEnd Time
09/24/2002160009/24/20021630
Subject:
SGP/EBBR/E9 - Net Rad data bad during dome replacement
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
The net radiation measurement was incorrect during replacement
of the top dome. Measurements calculated using net radiation are also incorrect.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D030114.9
Start DateStart TimeEnd DateEnd Time
11/16/2002133011/16/20021430
11/17/2002070011/19/20021730
Subject:
SGP/EBBR/E9 - AEM Malfunction
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
inbetween a home position, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction

sgp15ebbrE9.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D030117.26
Start DateStart TimeEnd DateEnd Time
07/11/2002160007/11/20021629
Subject:
SGP/EBBR/E26 - Measurements zero following logger restart
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most of the measurements were zero, which normally happens after a 
datalogger restart.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D030117.27
Start DateStart TimeEnd DateEnd Time
07/01/2002000007/11/20021300
Subject:
SGP/EBBR/E26 - Multiplexer Problem
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
One of the multiplexers exhibited dropouts of the channels, beginning
with the last channel at temperatures above about 30 C and moving backward
through the channels as the temperature rose. High temperatures affected the
switching speed of the multiplexer.  This is the first time that this behavior has been 
documented in a Campbell Scientific multiplexer. The multiplexer had
been in continuous field use for 10 years and had experienced probably more
switching cycles than what is normally expected of the device in that period.

The multiplexer was replaced to solve the problem.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • temp_air_top
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_4
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D030117.28
Start DateStart TimeEnd DateEnd Time
08/27/2002083009/05/20021700
Subject:
SGP/EBBR/E26 - Water in broken Net Radiometer Dome
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The net radiation measurement is incorrect. Measurements 
calculated using net radiation are also incorrect.  

No work-around is possible for this situation.
Measurements:sgp30ebbrE26.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE26.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D030117.29
Start DateStart TimeEnd DateEnd Time
11/01/2002084511/06/20020130
Subject:
SGP/EBBR/E26 - Battery Voltage Low
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
When Battery Voltage drops below 10.5 volts, most 
measurements are suspect and some are often incorrect.

The user will need to inspect the data carefully to 
determine the useability of the data.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D030128.2
Start DateStart TimeEnd DateEnd Time
12/04/2002101501/10/20031600
Subject:
SGP/EBBR/E26 - AEM Hung
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The AEM hung inbetween home positions during the period.  The Bowen ratio, gradient 
measurements, sensible heat flux, and latent heat flux are incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D030128.3
Start DateStart TimeEnd DateEnd Time
01/10/2003190001/10/20031904
Subject:
SGP/EBBR/E26 - Data zeros following logger restart
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most measurements were zero after restart of the CR10 datalogger,
after a calibration changeout of the EBBR unit.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D030128.4
Start DateStart TimeEnd DateEnd Time
01/14/2003172501/23/20031715
Subject:
SGP/EBBR/E26 - Left Air Temperature Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The left air temperature was incorrect during the period.  Poor electronic
connections may have caused this.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • vapor_pressure_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • vapor_pressure_bottom
  • temp_air_top
  • temp_air_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D030514.8
Start DateStart TimeEnd DateEnd Time
04/19/2003190005/16/20031500
Subject:
SGP/EBBR/E26 - E26 EBBR Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #1 was incorrect much of the time.

The sensor was replaced.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D030711.6
Start DateStart TimeEnd DateEnd Time
01/24/2003163503/06/20031520
Subject:
SGP/EBBR/E26 -Right Air Temperature Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
One of the Right Air Temperature connections was loose, producing incorrect data.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D030712.1
Start DateStart TimeEnd DateEnd Time
02/23/2003200003/13/20031745
Subject:
SGP/EBBR/E9  - AEM Hung Inbetween Home Positions
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The AEM was hung inbetween home positions, causing many measurements to be incorrect.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D030712.15
Start DateStart TimeEnd DateEnd Time
04/24/2003180004/24/20031830
Subject:
SGP/EBBR/E9  - 6 Month Checks
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D030712.2
Start DateStart TimeEnd DateEnd Time
05/09/2003180005/09/20031800
Subject:
SGP/EBBR/E9  - Soil Heat Flow #1 Incorrect
DataStreams:sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
Soil Heat Flow #1 was incorrect.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_1

sgp15ebbrE9.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D030712.23
Start DateStart TimeEnd DateEnd Time
04/17/2003144504/17/20031535
Subject:
SGP/EBBR/E26 -  6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D030712.3
Start DateStart TimeEnd DateEnd Time
05/14/2003110005/30/20031700
Subject:
SGP/EBBR/E9 -   Battery Voltage Low
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Many of the measurements are incorrect much of the time during this period,
when the battery voltage was 10.9 volts or less.
Measurements:sgp30ebbrE9.b1:
  • Barometric Pressure(atmos_pressure)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_trh_top
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • vapor_pressure_bottom
  • soil_heat_flow_3
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • home_signal_30
  • soil_temp_4
  • soil_temp_5
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Radiation, net(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_moisture_1
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_top

sgp15ebbrE9.b1:
  • soil_moisture_4_rr
  • soil_temp_3_rr
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_heat_flow_1_mv
  • soil_temp_5_rr
  • soil_temp_1_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • net_radiation_mv
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • rh_left_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • atmos_pressure_mv
  • rh_right_mv
  • wdir_vec_mean_mv
  • temp_trh_left_rr
  • soil_moisture_5_rr
  • soil_moisture_2_rr
  • soil_moisture_1_rr
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • temp_reference
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_top_fraction
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • Wind speed vector mean(wspd_vec_mean)
  • temp_trh_top
  • temp_air_bottom
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • Radiation, net(net_radiation)
  • wdir_vec_std
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D030728.4
Start DateStart TimeEnd DateEnd Time
06/12/2003023006/12/20030300
06/13/2003120006/13/20031230
Subject:
SGP/EBBR/E26 - Soil Heat Flow #5 Large Positive
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #5 was large positive for these two periods, for
an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D030729.2
Start DateStart TimeEnd DateEnd Time
07/24/2003123008/12/20031615
Subject:
SGP/EBBR/E9 - AEM Hung in home 30 position.
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
The AEM was hung in the home 30 position.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D030919.11
Start DateStart TimeEnd DateEnd Time
08/21/2003160008/21/20031600
Subject:
SGP/EBBR/E26  - Soil Storage Incorrect; Surface Fluxes Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
The half hour after restart of the CR10 datalogger, the soil temperatures for the 
beginning of the period are missing.  Therefore the soil energy storage and surface flux values 
are also incorrect.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • energy_storage_change_5
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4


Back To Table of Contents

DQRID : D030919.7
Start DateStart TimeEnd DateEnd Time
08/02/2003060008/04/20031800
Subject:
SGP/EBBR/E9  - Water in Net Radiometer; Surface Fluxes are Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D031031.3
Start DateStart TimeEnd DateEnd Time
09/23/2003160009/23/20031600
Subject:
SGP/EBBR/E9  - Measurements All Zero
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Data values were all zero after restarting the CR10 datalogger.
Measurements:sgp30ebbrE9.b1:
  • Barometric Pressure(atmos_pressure)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_trh_top
  • soil_heat_flow_5
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • vapor_pressure_bottom
  • soil_heat_flow_3
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • bowen_ratio
  • energy_storage_change_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • home_signal_30
  • soil_temp_4
  • soil_temp_5
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Radiation, net(net_radiation)
  • rh_top_fraction
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • temp_reference
  • soil_moisture_1
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • home_signal_15
  • vapor_pressure_top
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_top

sgp15ebbrE9.b1:
  • soil_moisture_4_rr
  • soil_temp_3_rr
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_heat_flow_1_mv
  • soil_temp_5_rr
  • soil_temp_1_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • net_radiation_mv
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • rh_left_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • atmos_pressure_mv
  • rh_right_mv
  • wdir_vec_mean_mv
  • temp_trh_left_rr
  • soil_moisture_5_rr
  • soil_moisture_2_rr
  • soil_moisture_1_rr
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • temp_reference
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • rh_top_fraction
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • Wind speed vector mean(wspd_vec_mean)
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_bottom
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • Radiation, net(net_radiation)
  • wdir_vec_std
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031103.1
Start DateStart TimeEnd DateEnd Time
10/30/2003154511/13/20031545
Subject:
SGP/EBBR/E26 - AEM Home Signals Incorrect, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During a preventative maintenance visit to perform the 6-month
calibrations, the home15 and home30 outputs began reading the
same as one another.  A fuse replacement and lubrication of the 
AEM sprockets on 11/13 corrected the problem.

During the interval specified, the home15, home30, and sensible
and latent heat fluxes are incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • home_signal_30
  • home_signal_15
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • home_signal
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031204.21
Start DateStart TimeEnd DateEnd Time
10/30/2003153510/30/20031615
Subject:
SGP/EBBR/E26 - 6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031204.8
Start DateStart TimeEnd DateEnd Time
11/04/2003173011/04/20031800
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D031211.3
Start DateStart TimeEnd DateEnd Time
10/13/2003000009/29/20041845
Subject:
SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
In a trip to E26, I found that a bad spark gap through which the barometer was powered was 
causing pressure measurements to be incorrect.  The pressure readings oscillated with 
the voltage of the EBBR battery.  During daytime the voltage and thus the pressure would 
increase and vice versa during dark hours.

Apparently only the positive side of the power supply was properly connected through the 
spark gap and thus the voltage received by the pressure sensor was lower than required to 
power it properly.  Under this condition the perssure measurement varies with voltage 
level.  The pressure measurements therefore had a diurnal signature and usually were 
incorrect.  

The decreased pressure during most times would cause latent heat flux to be slightly 
overestimated and sensible heat flux to be slightly underestimated.
Measurements:sgp30ebbrE26.b1:
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Barometric Pressure(atmos_pressure)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • atmos_pressure_mv

sgp5ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031222.13
Start DateStart TimeEnd DateEnd Time
12/14/2003010012/14/20031930
Subject:
SGP/EBBR/E9  - Net Radiometer Iced Over During Storm
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The net radiometer was covered with ice from a storm.  Net radiation values are incorrect, 
and are sometimes even negative during the daytime.  Sensible and latent heat fluxes are 
therefore incorrect.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D031222.14
Start DateStart TimeEnd DateEnd Time
12/09/2003202012/10/20030645
Subject:
SGP/EBBR/E9 - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D031222.24
Start DateStart TimeEnd DateEnd Time
12/12/2003193512/14/20031615
Subject:
SGP/EBBR/E26  - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D031222.25
Start DateStart TimeEnd DateEnd Time
12/12/2003214012/14/20031530
Subject:
SGP/EBBR/E26  - Wind Direction Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040304.28
Start DateStart TimeEnd DateEnd Time
02/02/2004020002/02/20041620
Subject:
SGP/EBBR/E26  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040304.29
Start DateStart TimeEnd DateEnd Time
02/02/2004041002/02/20041530
Subject:
SGP/EBBR/E26  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040304.8
Start DateStart TimeEnd DateEnd Time
01/27/2004174501/27/20041800
01/27/2004193501/28/20040140
01/28/2004033001/28/20040355
01/31/2004180002/12/20041640
Subject:
SGP/EBBR/E9  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition. The bearings
in the sensor appear to be worn, contributing to the problem.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D040304.9
Start DateStart TimeEnd DateEnd Time
02/02/2004000002/03/20041740
02/05/2004112002/05/20041405
02/09/2004094502/09/20041430
Subject:
SGP/EBBR/E9  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp5ebbrE9.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D040723.2
Start DateStart TimeEnd DateEnd Time
06/28/2004120006/29/20041530
Subject:
SGP/EBBR/E9 - net radiometer top dome broken, water in bottom dome
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The Net radiometer top dome was broken.  Site Ops did not indicate that there
was water in the bottom dome, but the data suggests it.  Net radiation values during the 
period are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D040813.5
Start DateStart TimeEnd DateEnd Time
07/30/2004160008/05/20041530
Subject:
SGP/EBBR/E26 - Soil Temperature #4 and Soil Heat Flow #4 Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
The soil temperature and soil heat flow probes for set #4 was pulled 
partially out of the ground.  This caused soil temperature #4 to be too high and soil heat 
flow #4 to be too low.  The error is not so great as to cause a large error in the 
sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • energy_storage_change_4
  • corr_soil_heat_flow_4
  • soil_temp_4
  • surface_soil_heat_flux_4
  • soil_heat_capacity_4
  • soil_heat_flow_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D041222.1
Start DateStart TimeEnd DateEnd Time
03/21/2003153010/12/20032355
Subject:
SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
In a trip to E26, I found that a bad spark gap through which the barometer was powered was 
causing pressure measurements to be incorrect.  The pressure readings oscillated with 
the voltage of the EBBR battery.  During daytime the voltage and thus the pressure would 
increase and vice versa during dark hours.

Apparently only the positive side of the power supply was properly connected through the 
spark gap and thus the voltage received by the pressure sensor was lower than required to 
power it properly.  Under this condition the perssure measurement varies with voltage 
level.  The pressure measurements therefore had a diurnal signature and usually were 
incorrect.  

The decreased pressure during most times would cause latent heat flux to be slightly 
overestimated and sensible heat flux to be slightly underestimated.
Measurements:sgp30ebbrE26.b1:
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Barometric Pressure(atmos_pressure)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • atmos_pressure_mv

sgp5ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D041222.10
Start DateStart TimeEnd DateEnd Time
10/05/2004163010/05/20041700
Subject:
SGP/EBBR/E9 - 6 Month Checks
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D041222.18
Start DateStart TimeEnd DateEnd Time
09/30/2004153009/30/20041600
Subject:
SGP/EBBR/E26 - 6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D041222.4
Start DateStart TimeEnd DateEnd Time
10/27/2004193011/05/20040100
11/10/2004060011/24/20041500
Subject:
SGP/EBBR/E26 - Low Battery Voltage - Many Measurements Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During low battery voltage conditions (< 10.5 V especially) many measurements are 
incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D041222.5
Start DateStart TimeEnd DateEnd Time
10/29/2004110010/29/20041600
Subject:
SGP/EBBR/E26 - Most Measurements Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most of the measurements became either too large or too small.
The cause is not known.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D050113.2
Start DateStart TimeEnd DateEnd Time
12/01/2004083001/31/20051400
Subject:
SGP/EBBR/E9 - Wind Speed Threshhold Low
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
When the wind speed is very low, the anemometer cups stop turning.  Wind
speeds above the threshhold may be underestimated.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D050206.16
Start DateStart TimeEnd DateEnd Time
01/05/2005074501/07/20051530
Subject:
SGP/EBBR/E26  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050206.8
Start DateStart TimeEnd DateEnd Time
01/04/2005150501/05/20050800
Subject:
SGP/EBBR/E9  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D050207.12
Start DateStart TimeEnd DateEnd Time
01/05/2005102001/06/20051730
Subject:
SGP/EBBR/E26  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050207.4
Start DateStart TimeEnd DateEnd Time
01/04/2005175501/05/20050800
Subject:
SGP/EBBR/E9  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE9.b1:
  • wdir_vec_mean_mv

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D050211.1
Start DateStart TimeEnd DateEnd Time
10/10/2004140002/17/20051630
Subject:
SGP/EBBR/E26 - Aging Pressure Sensor Output Changes
With Supply Voltage
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The E26 EBBR pressure sensor experienced the poor internal voltage regulation problem 
experienced at other sites last year.  Aging of the internal voltage regulator caused the 
pressure output to drop by 1-2 kPa (0.1-0.5 kPa is normal) when the Sun rose and the solar 
panel goosed the battery voltage up.  

The sensible and latent heat fluxes were not significantly affected.
Measurements:sgp30ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • atmos_pressure_mv

sgp5ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D050215.14
Start DateStart TimeEnd DateEnd Time
01/10/2005230001/11/20051645
Subject:
SGP/EBBR/E9  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE9.b1:
  • wdir_vec_mean_mv

sgp5ebbrE9.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D050215.15
Start DateStart TimeEnd DateEnd Time
02/08/2005053002/09/20051830
Subject:
SGP/EBBR/E9  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D050324.3
Start DateStart TimeEnd DateEnd Time
01/10/2003170003/03/20051600
Subject:
SGP/EBBR/E26 - Incorrect soil type coefficients used
DataStreams:sgp30ebbrE26.b1
Description:
The soil type coefficents for soil moisture were incorrect from the day
of the system installation on, making soil moisture values too large.

As a result, soil heat flows were overmeasured, and sensible and latent heat fluxes were 
underestimated.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_moisture_1
  • soil_heat_capacity_4
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D050601.2
Start DateStart TimeEnd DateEnd Time
05/02/2005121506/11/20050600
Subject:
SGP/EBBR/E9 - Soil moisture too high
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
The 15 and 30 minute data for sm3 indicated that there was a problem with the sensor that 
kept the soil moisture artificially high.  This corrected itself on 6/11, but it is not 
clear why. 

A new sensor was installed on 6/17 and it has behaved well since then.
Measurements:sgp30ebbrE9.b1:
  • soil_moisture_3

sgp15ebbrE9.b1:
  • soil_moisture_3_rr


Back To Table of Contents

DQRID : D050719.15
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/31/20051700
Subject:
SGP/EBBR/E26 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE26.b1
Description:
Effective 20050331.1700, the EBBR.E26 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050331, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE26.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE26.a1).
~
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D050719.8
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051600
Subject:
SGP/EBBR/E9 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE9.b1
Description:
Effective 20050322.1600, the EBBR.E9 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE9.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE9.a1).
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)


Back To Table of Contents

DQRID : D051104.1
Start DateStart TimeEnd DateEnd Time
10/31/2005090011/01/20051630
Subject:
SGP/EBBR/E9 - Net Radiation Incorrect: Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Water had entered the top of the net radiometer during the rain on 10/31 early morning.  
The net radiation, and thus sensible and latent heat fluxes were incorreect during the 
stated period.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D051106.22
Start DateStart TimeEnd DateEnd Time
03/08/2005163003/22/20051600
Subject:
SGP/EBBR/E9 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)


Back To Table of Contents

DQRID : D051106.30
Start DateStart TimeEnd DateEnd Time
03/03/2005180003/31/20051700
Subject:
SGP/EBBR/E26 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D051112.6
Start DateStart TimeEnd DateEnd Time
10/13/2003000004/19/20052359
Subject:
SGP/EBBR/E9 - metadata corrections
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
On 20050420, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E9 data collected by ARM back to the installation of the 
instrument in December 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE9.b1:
  • base_time

sgp15ebbrE9.b1:
  • base_time

sgp5ebbrE9.b1:
  • base_time


Back To Table of Contents

DQRID : D051112.9
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E26 - metadata corrections
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E26 data collected by ARM back to the installation of the 
instrument in June 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE26.b1:
  • base_time

sgp15ebbrE26.b1:
  • base_time

sgp5ebbrE26.b1:
  • base_time


Back To Table of Contents

DQRID : D051215.2
Start DateStart TimeEnd DateEnd Time
10/30/2005070011/01/20051615
Subject:
SGP/EBBR/E9 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The top dome of the net radiometer was broken, resulting in net radiations that were too 
small, and thus sensible and latent heat fluxes that were too small.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D051222.1
Start DateStart TimeEnd DateEnd Time
12/20/2005080012/22/20051500
Subject:
SGP/EBBR/E26 - Data Suspect During Low Supply Voltage
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Low battery supply voltage resulted in high home signals and questionable data at times.
Data for battery voltage <10.5 volts should be considered to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • time
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time


Back To Table of Contents

DQRID : D060501.26
Start DateStart TimeEnd DateEnd Time
02/21/2006040002/25/20061700
Subject:
SGP/EBBR/E26 - Measurements Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most measurements were incorrect during low battery voltage conditions.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • time
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time


Back To Table of Contents

DQRID : D060621.7
Start DateStart TimeEnd DateEnd Time
04/30/2006223005/02/20061550
Subject:
SGP/EBBR/E9 - Wind Speed Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The wind speed measurement was incorrect after the cup anemometer lost a cup.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D061220.15
Start DateStart TimeEnd DateEnd Time
07/05/1993000010/12/20032330
Subject:
SGP/EBBR/E26 - Wind Direction Dependency of Surface Fluxes and General Data Quality 
Information
DataStreams:sgp30ebbrE26.b1
Description:
Beginning in FY2006, Data Quality Reports are not written for missing 
data or for situations when qc flags clearly show that the data is 
incorrect (this is true for most of the conditions listed below).  
DQRs are written for periods when data is incorrect, when the situation 
is not represented by qc flags in the data, and it's not obvious that 
the data should have been flagged as incorrect.

The EBBR data is only useful for particular wind directions at each 
Extended Facility.  Please use the following resources to help in 
interpreting the EBBR data.

1) qc flags in the EBBR data.

2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/

3) SGP EF Surface Conditions Observations (EFSCO) at 
http://198.124.96.210:591/sfc_cond1/default.htm

4) Surface fluxes are valid only for the following wind directions
(in degrees):

0-33, 243-360

Note that there are wind directions at most sites for which the fetch
is insufficient and therefore EBBR data is invalid.  Appropriate 
fetch was determined from a 1/40 measurement height to fetch ratio, 
resulting in a required minimum fetch of 120 m.  Particular attention 
should be paid to the limited valid wind directions for the Central 
Facility EBBR.  The surface vegetation type for the EBBRs is grazed 
or ungrazed grassland (refer to the EFSCO for state).

5) Some conditions that commonly cause the EBBR primary measurements to 
be incorrect or missing follow:

a) Sensible and latent heat fluxes are not accurate during times when 
the Automatic Exchange Mechanism (AEM) is not functioning properly.  
The AEM switches the gradient measuring instrumentation between the 
top and bottom positions every 15 minutes; this reduces the effects of 
instrument offsets.  Sometimes the AEM does not reach it's full extent 
of travel, resulting in the home signal being zero.  

b) Sensible and latent heat fluxes are sometimes incorrect when surface 
soil heat flow is out of range, as seen in the average soil heat flux 
(ave_shf).

c) Very light winds may be seen at nights for brief periods. Wind 
direction flops around a lot during low wind conditions (< 1.5 m/s) 
and is often unreliable during those periods.

d) Missing data periods occur at times; this is usually a site data 
system collection/communication problem; it can also occur during 
replacement of the system with a newly calibrated unit.  Missing data 
is sometimes filled in later from manual or automatic re-collection of 
the data.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • rh_top_fraction
  • bowen_ratio
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • soil_heat_capacity_1
  • lat
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • temp_air_top
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • base_time
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D061220.5
Start DateStart TimeEnd DateEnd Time
07/11/1993150010/12/20032330
Subject:
SGP/EBBR/E9 - Wind Direction Dependency of Surface Fluxes and General Data Quality 
Information
DataStreams:sgp30ebbrE9.b1
Description:
Beginning in FY2006, Data Quality Reports are not written for missing 
data or for situations when qc flags clearly show that the data is 
incorrect (this is true for most of the conditions listed below).  
DQRs are written for periods when data is incorrect, when the situation 
is not represented by qc flags in the data, and it's not obvious that 
the data should have been flagged as incorrect.

The EBBR data is only useful for particular wind directions at each 
Extended Facility.  Please use the following resources to help in 
interpreting the EBBR data.

1) qc flags in the EBBR data.

2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/

3) SGP EF Surface Conditions Observations (EFSCO) at 
http://198.124.96.210:591/sfc_cond1/default.htm

4) Surface fluxes are valid only for the following wind directions
(in degrees):

0-360

Note that there are wind directions at most sites for which the fetch
is insufficient and therefore EBBR data is invalid.  Appropriate 
fetch was determined from a 1/40 measurement height to fetch ratio, 
resulting in a required minimum fetch of 120 m.  Particular attention 
should be paid to the limited valid wind directions for the Central 
Facility EBBR.	The surface vegetation type for the EBBRs is grazed 
or ungrazed grassland (refer to the EFSCO for state).

5) Some conditions that commonly cause the EBBR primary measurements to 
be incorrect or missing follow:

a) Sensible and latent heat fluxes are not accurate during times when 
the Automatic Exchange Mechanism (AEM) is not functioning properly.  
The AEM switches the gradient measuring instrumentation between the 
top and bottom positions every 15 minutes; this reduces the effects of 
instrument offsets.  Sometimes the AEM does not reach it's full extent 
of travel, resulting in the home signal being zero.  

b) Sensible and latent heat fluxes are sometimes incorrect when surface 
soil heat flow is out of range, as seen in the average soil heat flux 
(ave_shf).

c) Very light winds may be seen at nights for brief periods. Wind 
direction flops around a lot during low wind conditions (< 1.5 m/s) 
and is often unreliable during those periods.

d) Missing data periods occur at times; this is usually a site data 
system collection/communication problem; it can also occur during 
replacement of the system with a newly calibrated unit.  Missing data 
is sometimes filled in later from manual or automatic re-collection of 
the data.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Barometric Pressure(atmos_pressure)
  • home_signal_30
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_temp_4
  • soil_temp_5
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Radiation, net(net_radiation)
  • rh_top_fraction
  • base_time
  • lon
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • temp_trh_top
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • soil_heat_flow_5
  • temp_reference
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • vapor_pressure_bottom
  • temp_air_bottom
  • soil_heat_flow_3
  • soil_moisture_1
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • alt
  • soil_moisture_4
  • time_offset
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • home_signal_15
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • lat
  • bowen_ratio
  • temp_air_top


Back To Table of Contents

DQRID : D071001.1
Start DateStart TimeEnd DateEnd Time
09/28/2007014010/11/20071730
Subject:
SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The left Thum (temperature of the humidity sensor chamber) measurement was incorrect at 
times, affecting several measurements, including the sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_trh_left_rr

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D080102.2
Start DateStart TimeEnd DateEnd Time
12/22/2007150001/08/20081800
Subject:
SGP/EBBR/E9 - Net Radiation Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
There was water in the net radiometer.  

The net radiation data was incorrect.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D090313.11
Start DateStart TimeEnd DateEnd Time
01/27/2009035001/28/20091910
Subject:
SGP/EBBR/E9 - Wind Speed Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D090313.8
Start DateStart TimeEnd DateEnd Time
01/26/2009180501/28/20091955
Subject:
SGP/EBBR/E26 - Wind Speed Incorrect
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D091015.2
Start DateStart TimeEnd DateEnd Time
10/14/2009023010/17/20091530
Subject:
SGP/EBBR/E26 - Low supply voltage
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Low supply voltage during much of the period resulted in missing or incorrect
data most of the time.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D100521.2
Start DateStart TimeEnd DateEnd Time
03/20/2010173005/10/20101800
Subject:
SGP/EBBR/E9 - Sensible and latent heat flux incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
Sensible and latent heat fluxes were sometimes incorrect when soil temperature 4 and soil 
moisture 4 were acting up.

Sometimes the sensible and latent heat fluxes are indicated as incorrect by an offscale 
reading produced by the data logger error checking routine.  This occurs mostly during 
daytime.  However, you will have to examine the soil moisture 4 and soil temperature 4 data 
to see when they were incorrect or offscale to determine all times for which sensible and 
latent heat fluxes were incorrect.
Measurements:sgp30ebbrE9.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • soil_temp_4
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_moisture_4

sgp15ebbrE9.b1:
  • soil_temp_4_rr
  • soil_moisture_4_r
  • soil_moisture_4_rr


Back To Table of Contents

DQRID : D101127.1
Start DateStart TimeEnd DateEnd Time
09/28/2010163010/06/20102130
Subject:
SGP/EBBR/E9 - T/RH Probe Temperature Problem - Sensible and Latent Heat Fluxes Affected
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
During mid-day the left T/RH probe temperature was offscale, sometimes resulting in 
incorrect sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • temp_trh_top
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_trh_bottom


Back To Table of Contents

DQRID : D110105.4
Start DateStart TimeEnd DateEnd Time
10/14/2010080012/07/20101600
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
The right Air Temperature probe leads were loose.
During nighttime the right Air Temperature went offscale,
resulting in incorrect sensible and latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • temp_air_right

sgp5ebbrE9.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D110830.2
Start DateStart TimeEnd DateEnd Time
06/09/2011050009/29/20111600
Subject:
SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE9.b1
Description:
The AEM stuck in the home 15 or home 30 position, resulting in incorrect sensible and 
latent heat fluxes.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)


Back To Table of Contents

DQRID : D931108.6
Start DateStart TimeEnd DateEnd Time
07/11/1993030011/01/19931700
Subject:
SGP/EBBR/E9 - pressure calibration
DataStreams:sgp30ebbrE9.b1
Description:
In the original Campbell CR10 software provided by the vendor (version 1),
the EBBR had incorrect calibration pressure sensor slopes and offsets.
The slopes and offset was carried through into version 2 of the
software and was not discovered by the mentor (me) until sometime later.
The calibration and slope did not deleteriously affect calculations in
the program since only a four percent reduction in atmospheric pressure
measurement resulted (the calculations are not very sensitive to small
errors in pressure). The vendor does not recall how the wrong
calibrations came to be used.   

Version 4 of the CR10 program includes the proper calibration and offset. 
This remedies the apparent offset problem (it was actually a calibration 
and offset problem). In comparisons with the co-located SMOS pressure
sensor, the difference between the SMOS and EBBR pressure values appeared
almost constant with time, hence the assumption of an offset problem.
However, the EBBR pressure sensor offsets are so large (a consequence of
tailoring the calibration curve to a small range of elevations in which the
calibration applies) that the very small error in slope was difficult to
recognize.

The outputted pressure values for the EBBR system can be corrected
with the following information and equations.  

         Old Slope     Old Offset        New Slope     New Offset

          0.01952        81.24            0.02031        81.27

   Correct Pressure =
               ((Current Pressure Data - 81.24)*0.02031/0.01952) + 81.27
                    =  1.04047*(Current Pressure Data) - 3.258
Measurements:sgp30ebbrE9.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D940211.1
Start DateStart TimeEnd DateEnd Time
12/28/1993164512/28/19931900
Subject:
SGP/EBBR/E26 - Invalid data during Preventative Maintenance
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During a preventative maintenance visit the +12V DC supply to the wind
direction sensor at E26, Cement, Ok was temporarily disconnected, resulting
in invalid wind direction data for December 28, 1993 from 1645 through 1900
GMT.  The following fields are therefore invalid for that period:

30 minute: wind_d, sigma_wd, res_ws

15 minute: mv_wind_d

5 minute: wind_d, sigma_wd, res_ws.
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D940301.2
Start DateStart TimeEnd DateEnd Time
12/01/1993000002/02/19942359
Subject:
SGP/EBBR/E26 - Winds, SM2 Invalid data 10/10/93 - 2/2/94
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Beginning October 10, 1993 the EBBR system at E26, Cement, OK began to have
problems with outputs from soil moisture sensor number 2 and the wind direction
sensor.  This situation also occured in early 1993 and was eliminated by
replacing the soil moisture sensor (after replacing the wind direction
sensor did not help).  This time, replacing the soil moisture sensor did
not help, but the problem has not re-occured since the wind direction
sensor was replaced on February 2, 1994.  During periods of bad data the
wind direction output is a constant 135 degrees and soil moisture two is
offscale.

Invalid data for a constant wind direction of 135 degrees is:

30 minute: res_ws, wind_d, sigma_wd

15 minute: mv_wind_d

5 minute: res_ws, wind_d, sigma_wd.

Invalid data for soil moisture 2 offscale is:

30 minute: sm2, c_shf2, cs2, ces2, g2, ave_shf, h, e

15 minute: r_sm2

5 minute: no data affected.

    Apparent cause of data loss, if known:   Apparently an electronic
    problem in interfacing an intermittently malfunctioning wind direction
    sensor to the data acquisition system multiplexer, thereby affecting
    the other sensor (soil moisture 2) on that multiplexer pair.
Measurements:sgp30ebbrE26.b1:
  • soil_heat_capacity_2
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • wdir_vec_std
  • energy_storage_change_2
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Wind speed vector mean(wspd_vec_mean)
  • corr_soil_heat_flow_2
  • soil_moisture_2

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_moisture_2_r

sgp5ebbrE26.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D940301.6
Start DateStart TimeEnd DateEnd Time
02/23/1994040002/24/19941300
Subject:
SGP/EBBR/E9 - Invalid wind speed frozen sensor
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
On February 23, 1994 the EBBR wind speed sensor at E9, Ashton, KS was
frozen to a stationary condition by ice.  It broke free in strong winds on
February 24, 1994.  Invalid data for the time period indicated is:

30 minute: wind_s, res_ws

15 minute: wind_s

5 minute: wind_s, res_ws.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D940329.1
Start DateStart TimeEnd DateEnd Time
03/07/1994140003/16/19941700
Subject:
SGP/EBBR/E26 - Wind Direction Sensor Malfunction
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The wind direction sensor malfunctioned, outputting nearly a 
constant value, invalidating the following data values.

30 minute: wind_d, sigma_wd, res_ws

15 minute: mv_wind_d

5 minute: wind_d, sigma_wd, res_ws

The first good data after the affected period was the 1700 GMT, 30 minute
data on March 16, 1994.
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D940329.3
Start DateStart TimeEnd DateEnd Time
07/11/1993150103/22/19941643
Subject:
SGP/E9/EBBR - AEM Malfunction
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
EDITOR'S NOTE:  This DQR refers, in part, to data collected prior to the
begin date of regular ARM data.  During the first month covered by this
DQR, the EBBR.E9 data were not archived with standard ARM names.  The data
are therefore not readily available, but can be made available by special
request.  The total period covered by the problem documented here is
930615.0000-940322.1643.

The AEM at E9 frequently did not function properly during the time period
stated.  Please see the notes in the EBBR platform describing home signal
conditions for which certain of the data fields are suspect.  The newly
installed AEM is performing properly so far.

The files could be flagged, but it is up to the user to read the
platform notes concerning the condition of the home signal and then
view the quality of the data accordingly.  I would be at my terminal full-
time in attempting to list all days and times and data fields that are
affected by the numerous AEM malfunctions.  Furthermore, I have done so
previously in several PIFs that I will reference here for information:
P931101.4, P931115.2, P940105.2, P940211.3
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • home_signal_30
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • home_signal_15
  • rh_top_fraction

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • home_signal
  • temp_trh_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D940503.1
Start DateStart TimeEnd DateEnd Time
04/05/1994150004/19/19941525
Subject:
SGP/EBBR/E9 - AEM failure
DataStreams:sgp30ebbrE9.b1
Description:
The Automatic Exchange Mechanism would not function.  It was decided to
take the unit back to SGP CART to try to repair it.  A spare AEM was not
available for a replacement, so the aspirated radiation shields housing
temperature and humidity gradient sensors were attached to the EBBR
framework, one meter apart vertically, with the right side in the lower
position.  The housings remained this way for two weeks.  During this time
period, home signal, sensible heat flux, and latent heat flux values are
incorrect.  Significant reprocessing would be required to obtain correct
fluxes, and that would be possible only if one assumed that offsets in the
sensor calibrations are negligible; that is a very debatable assumption
considering that the EBBR system is already half a year past due for
calibration.
Measurements:sgp30ebbrE9.b1:
  • home_signal_30
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_15


Back To Table of Contents

DQRID : D940606.1
Start DateStart TimeEnd DateEnd Time
05/22/1994220005/25/19941645
Subject:
SGP/EBBR/E26 - Wind Speed Malfunction
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
For an unknown reason, the wind speed sensor at Cement began to record very
low wind speeds on a consistent basis, with most of the speeds recorded
reflecting what appeared to be zero wind speed (calibration offset).  When
the sensor was replaced on 5/25/94, it was damaged, although this damage
apparently did not occur until a thunderstorm around midnight (local time)
May 24.  The wind direction sensor was also damaged by the storm at the
same time.  At any rate, the wind speed data during the period listed 
should be considered questionable.  The wind speed sensor was replaced on
May 25, 1994 at 1639.  Old sensor S/N K1032, New sensor S/N K1035.
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D940606.2
Start DateStart TimeEnd DateEnd Time
05/25/1994043005/25/19941640
Subject:
SGP/EBBR/E26 - Wind Direction Sensor Failure
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Apparently, a fairly severe thunderstorm passed over the Cement, OK EBBR
early on May 25, 1994 (around midnight May 24, local time).  The storm
damaged the wind direction sensor and the wind speed sensor.  Wind
Direction and Sigma of Wind Direction data for the period listed 
should be considered incorrect.  The sensors were replaced on May 25, 1994
at 1631.  Old sensor S/N K3038, New sensor S/N K3040.
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D940711.2
Start DateStart TimeEnd DateEnd Time
06/17/1994190006/17/19941930
06/18/1994020006/25/19941930
06/25/1994230006/28/19941600
06/15/1994210006/15/19942130
06/15/1994230006/16/19940030
06/16/1994213006/17/19941530
Subject:
SGP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor Failure
DataStreams:sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
Failure of soil heat flow sensor #5 at E9, Ashton, KS resulted in incorrect
data values for 6 fields for much of the period of time listed above.  The
soil heat flow values from #5 were so large (in the absolute) that it
deleteriosly affected the soil heat flux average and the sensible and
latent heat fluxes.  The fields affected were:

30 minute: shf5, c_shf5, g5, ave_shf, e, h

15 minute: mv_hft5.

I list only the 30 minute times affected below; it can be assumed that the
15 minute value contained in the half hour are incorrect.  Sensor #5 was
replaced at 1545 GMT on June 28.  Old S/N 923029, new S/N 923092.  Half hour
1600 GMT is missing due to having to reload the CR10 program with a new shf5
calibration.  Sensible and latent heat fluxes can be recomputed by averaging
soil heat flow sensors 1-4; use the following equations:

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q +ave_shf)/(1 + bowen)

h = e * bowen,

where g is total soil heat flow, q is net radiation, and bowen is Bowen
Ratio.

Affected half hours:

Date          Times (GMT)

6/15    2130, 2300, 2330
6/16    0000, 0030, 2130-2330
6/17    0000-1530, 1900, 1930
6/18    0200-2330
6/19    All
6/20    All
6/21    All
6/22    All
6/23    All
6/24    All
6/25    0000-1930, 2300, 2330
6/26    All
6/27    All
6/28    0000-1600
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • corr_soil_heat_flow_5

sgp15ebbrE9.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D940818.1
Start DateStart TimeEnd DateEnd Time
07/31/1994210008/17/19941700
Subject:
SGP/EBBR/E26 - Soil Moisture Sensor Malfunction
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil moisture sensor #1 at Cement, Ok, E26 began a slow drift downwards on
July 31, 1994.  This continued until the sensor was replaced at 1700 GMT on
August 17, 1994.  The downwards drift occured coincident with a constant
decrease in soil moisture at the site.  As a result, the average soil
moisture (for the set of five sensors) was reduced by only about 2% (for a
range of 10 to 22%), and thus had a negligible effect on the calculations
of sensible and latent heat flux.  The sm1 output dropped below zero at
times during August 14-17.

Soil Moisture #1 Data Fields:

15 minute: r_sm1

30 minute:  sm1
Measurements:sgp30ebbrE26.b1:
  • soil_moisture_1

sgp15ebbrE26.b1:
  • soil_moisture_1_r


Back To Table of Contents

DQRID : D940826.1
Start DateStart TimeEnd DateEnd Time
08/19/1994010008/23/19941530
Subject:
SGP/EBBR/E9 - Malfunctioning Wind Dir Sensor, Incorrect SM2 Results
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
It has been reported previously that a malfunction of the wind direction
sensor resulting in zero or 135 degree outputs can cause the soil moisture
#2 sensor to read offscale.  The two sensors are attached to a multiplexer
pair.  The manufacturer of the multiplexer and data acquisition system have
not been able to explain how our instrument configuration can cause this
effect.  Shortly after 0030 GMT on August 20, 1994 significant rainfall
occurred, being reflected in more than a doubling of soil moisture within
an hour.  During the time period listed above, the wind direction sensor
mulfunctioned (apparently caused by water in the wind direction sensor
electronics), causing the following data fields to be incorrect:

5 minute:  res_ws, wind_d, sigma_wd

15 minute: mv_wind_dir

30 minute: res_ws, wind_d, sigma_wd.

During part of the listed period, Soil Moisture #2 was also incorrect,
being offscale; during those times the following 30 minute data is also
incorrect:

30 minute: sm2, c_shf2, ave_shf, cs2, ces2, g2, h, e.
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE9.b1:
  • wdir_vec_mean_mv

sgp5ebbrE9.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D940826.2
Start DateStart TimeEnd DateEnd Time
08/17/1994170008/17/19942300
Subject:
SGP/EBBR/E9 - Reprocess: Soil Heat Flux Out of Range
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
For an unknown reason, soil heat flux sensor #5 indicated too small a value
for the period listed above.  This resulted in an incorrect average of soil
heat flow for the five sets of soil heat flow plates, and therefore
incorrect e (latent heat flux) and h (sensible heat flux) in the 30 minute
data.  The following data values are incorrect:

15 minute: mv_hft5

30 minute: shf5, c_shf5, ave_shf, g5, e, h

The latent and sensible heat flux can be recalculated by using only soil
heat flows 1 through 4 to calculate the average soil heat flow,

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q).
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • corr_soil_heat_flow_5

sgp15ebbrE9.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D940830.7
Start DateStart TimeEnd DateEnd Time
08/20/1994013008/23/19941600
Subject:
SGP/EBBR/E9 - Hail Damage to Net Radiometer and Wind Speed Sensor
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Golf ball size hail was reported for the Ashton site for early August 20,
1994.  It damaged the wind speed sensor and the net radiometer shortly
before 0130 GMT.  The following data fields are to be flagged as incorrect
for the periods listed above (resultant wind speed has already been
indicated as incorrect in a previous DQR that documented the malfunction of
the wind direction sensor):

5 minute:  wind_s, res_ws, q

15 minute: wind_s, mv_q

30 minute: wind_s, res_ws, q, h, e.

Note that h and e are also incorrect as a consequence of q being incorrect.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Radiation, net(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D941021.11
Start DateStart TimeEnd DateEnd Time
09/14/1994160009/28/19941515
Subject:
SGP/EBBR/E26 - Net Radiometer Hemisphere Changes
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The upper hemisphere of the net radiometer at the site was punctured
allowing water to collect in the lower (and sometimes upper) section of the sensor. The 
punctures are most likely the result of migratory birds (a problem that we have experienced 
almost every year here at ANL also). The punctures (and water in some net radiometers) 
did not result in obvious invalidation of the data.

Whether there is water in the lower hemisphere or not, a small puncture of the upper 
hemisphere would not have a major effect on the net radiation measurement.  Significant 
amounts of water in the lower
hemisphere should have a major effect on nighttime measurements particularly, although 
that effect is hard to detect in the data. 
The date when the puncture occurred is approximate - but is certainly 
no more than two weeks before the hemisphere was replaced.
Measurements:sgp30ebbrE26.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • net_radiation_mv

sgp5ebbrE26.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D941212.1
Start DateStart TimeEnd DateEnd Time
12/07/1994043012/07/19940800
Subject:
SGP/EBBR/E26 - Wind Direction Sensor Affect on Soil Moisture 2
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
I have written a number of previous PIFs and DQRs about this same problem
previously.  This occurred most recently at E9, Ashton, KS in August 1994.
The wind direction sensor is on the same data acquisition system multiplexer
pair as soil moisture sensor 2.  Sometimes a malfunctioning wind direction
sensor (resulting in a constant wind direction of 135 degrees) will cause the
soil moisture 2 measurement to be offscale.  Between 0430 and 0800 GMT the wind
direction sensor did not function properly at E22, Cordell, KS.  As has often
been the case, soil moisture measurements were affected for a shorter time
period, from 0500 through 0730 GMT.  The cause of this problem is unknown and
only occurs on the multiplexer pair to which the wind direction sensor is
connected, not on any other pair to which a soil moisture sensor is attached.
None of the manufacturers of the applicable equipment can explain the
problem.  As done before, I will monitor the data for further occurrences
of this condition; if the frequency of occurrence increases, further action
will be taken.

The following data and times are incorrect:

Winds: 0430-0800 GMT

5 minute:  wind_d, sigma_wd, res_ws
15 minute: mv_wind_d
30 minute: wind_d, sigma_wd, res_ws

Soil Moisture 2: 0500-0730 GMT

15 minute: r_sm2
30 minute: sm2, c_shf2, cs2, ces2, g2, ave_shf, h, e
Measurements:sgp30ebbrE26.b1:
  • soil_heat_capacity_2
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • energy_storage_change_2
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_2
  • corr_soil_heat_flow_2
  • soil_moisture_2

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_moisture_2_r

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D941221.1
Start DateStart TimeEnd DateEnd Time
11/09/1994161511/09/19941800
Subject:
SGP/EBBR/E26 - T/RH Check
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

5 minute:  1615, 1620, 1625, 1630, 1635, 1640, 1645, 1650, 1655,
           1700, 1705, 1710, 1715, 1720, 1725, 1730, 1735
15 minute: 1615, 1630, 1645, 1700, 1715, 1730, 1745
30 minute: 1630, 1700, 1730, 1800

(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D950126.2
Start DateStart TimeEnd DateEnd Time
08/19/1994170008/19/19942300
10/13/1994180010/14/19941500
10/17/1994203010/17/19942100
10/28/1994203010/28/19942230
12/26/1994170012/27/19940130
12/27/1994160012/27/19941630
01/02/1995060001/05/19951700
01/05/1995220001/09/19950230
01/14/1995080001/15/19950300
01/15/1995120001/16/19951600
12/20/1994063012/23/19940530
01/09/1995090001/14/19950400
Subject:
SGP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Data
DataStreams:sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
Soil heat flow sensor #5 periodically outputted incorrect values from
mid-August 1994 until mid-January 1995.  The output often indicated large
negative heat flow.  The sensor was replaced on January 23, 1995, even
though the previous week of data was correct.  The data affected (and thus
incorrect) includes:

15 minute: mv_hft5
30 minute: shf5, c_shf5, g5, ave_shf, e, h.

The dates and times (GMT) of incorrect values are listed below.  Only half
hour times are listed.

08/19/94  1700-2300
10/13/94  1800-2330
10/14/94  0000-1500
10/17/94  2030-2100
10/28/94  2030-2230
12/20/94  0630-2330
12/21/94  0000-2330
12/22/94  0000-2330
12/23/94  0000-0530
12/26/94  1700-2330
12/27/94  0000-0130, 1630
01/02/95  0600-2330
01/03/95  0000-2330
01/04/95  0000-2330
01/05/95  0000-1700, 2200-2330
01/06/95  0000-2330
01/07/95  0000-2330
01/08/95  0000-2330
01/09/95  0000-0230, 0900-2330
01/10/95  0000-2330
01/11/95  0000-2330
01/12/95  0000-2330
01/13/95  0000-2330
01/14/95  0000-0400, 0800-2330
01/15/95  0000-0300, 1200-2330
01/16/95  0000-1600

The latent and sensible heat fluxes can be recalculated by using only soil
heat flows 1 through 4 to calculate the average soil heat flow,

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q)
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • corr_soil_heat_flow_5

sgp15ebbrE9.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D950308.2
Start DateStart TimeEnd DateEnd Time
02/21/1995003002/21/19951600
Subject:
SGP/EBBR/E9 - Radiation Shield Problem
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The left radiation shield was off during the period of time above.  Close
inspection of the 15 minute data was required to detect when the shield
fell off.  As is often the case in such a situation, the 30 minute data
does not adequately indicate such a failure.  A radiation shield has fallen off
of an EBBR before, apparently a result of vibration of the AEM during
exchanges.  All air and humidity probe temperatures (except the reference
temperature), relative humidities, vapor pressures, Bowen ratio, sensible heat
flux, and latent heat flux during this period are considered to be incorrect.
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D950308.3
Start DateStart TimeEnd DateEnd Time
02/16/1995150002/17/19951230
Subject:
SGP/EBBR/E26 - Frozen Wind Speed Sensor
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On February 16, 1994 a frontal system deposited freezing rain in central
Oklahoma that resulted in the EBBR wind speed instrument becoming frozen in
place at Cement (E26) for part of two days.  All 5, 15, and 30 minute data
values indicated below are incorrect for all times within the period
indicated.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D950626.10
Start DateStart TimeEnd DateEnd Time
04/11/1995123004/12/19950615
04/12/1995131504/12/19951400
Subject:
SGP/EBBR/E26 - Stopped Ventilation Fan
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On April 11, 1995, a site operator discovered the right aspirator ventilation
fan of the EBBR to be stopped.  Inspection of the data indicates that this
condition occurred during the two periods shown above; the fan apparently
worked briefly inbetween the periods.  Lack of ventilation of
the temperature and relative humidity sensors attached to the AEM results
in incorrect measurements of air temperature and relative humidity by the
right aspirator probes, and therefore all quantities calculated from them,
including sensible and latent heat fluxes, are incorrect as well.
The quantities that are incorrect for the periods indicated are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, mv_hum_r, tair_r

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_trh_right_rr
  • rh_right_mv

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D950626.11
Start DateStart TimeEnd DateEnd Time
04/18/1995013004/18/19951620
Subject:
SGP/EBBR/E9 - Stopped Ventilation Fan
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
On April 18, 1995, a site operator discovered the right aspirator ventilation
fan of the EBBR to be stopped.  Inspection of the data indicates that this
condition began early in the GMT day.  Interpretation of the start time of
the condition is made more difficult by a slight bias low in absolute
temperature in comparison to the left temperature probe.  Lack of ventilation
of the temperature and relative humidity sensors attached to the AEM results
in incorrect measurements of air temperature and relative humidity by the
right aspirator probes, and therefore all quantities calculated from them,
including sensible and latent heat fluxes, are incorrect as well.
The quantities that are incorrect for the period above are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, mv_hum_r, tair_r

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • temp_air_right
  • rh_right_mv

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D950626.12
Start DateStart TimeEnd DateEnd Time
04/18/1995113004/18/19951530
Subject:
SGP/EBBR/E9 - Water in Net Radiometer
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The top dome of the net radiometer was broken and a small amount of water
had collected in the bottom dome of the net radiometer.  It is not obvious
that it had been there for more than several hours before the site operators
arrived for a preventative maintenance visit.  There are noticable effects on
the data for the period listed above.  The domes were replaced.  The following
data is incorrect for the period above:

5 minute:  q

15 minute: mv_q

30 minute: q, e, h
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D950626.14
Start DateStart TimeEnd DateEnd Time
04/26/1995194504/26/19952000
Subject:
SGP/EBBR/E26 - Reprocess: Soil Heat Flow Sensor 1 Replacement
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
During preventative maintenance, site operations personnel observed that
soil heat flow sensor #1 at Cement, OK (E26) was outputting larger values
than the other four sensors.  Therefore, they replaced sensor #1.  A review
of the data indicates that the sensor was not malfunctioning, but that its
calibration was just too large.  The longer the sensors are in the ground,
the greater the likelihood that they will drift from their original
calibration.  The difference in the average soil heat flux caused by the #1
sensor data values being included in the average will have less than a 5%
affect on the calculated latent and sensible heat fluxes.  The data should
therefore not be labelled as incorrect.

However, during the replacement of sensor #1, the #1 data was spiked,
causing the following data values to be incorrect for the period listed:

15 minute: mv_hft1 at 1945 GMT.
30 minute: shf5, c_shf5, g5, ave_shf, e, h, bowen at 2000 GMT.

The latent and sensible heat fluxes can be recalculated by using only soil
heat flows 2 through 5 to calculate the average soil heat flow,

ave_shf = (g2 + g3 + g4 + g5)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q).
Measurements:sgp30ebbrE26.b1:
  • bowen_ratio
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D950626.19
Start DateStart TimeEnd DateEnd Time
05/09/1995170505/16/19951900
05/24/1995193005/28/19950100
05/28/1995013006/01/19951630
06/05/1995173006/05/19951900
06/06/1995153006/06/19951900
Subject:
SGP/EBBR/E26 - Right Air Temperature Malfunction
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The right air temperature probe malfunctioned continuously during the
periods of time indicated above as continuous.  On May 16, 1995, by 1900 GMT,
the probe was replaced (old S/N 92007, new S/N 92013).  There was a complete
loss of data between 1200 and 1900 GMT as Site Operations repaired a corroded
battery terminal.  For several days the right air temperature probe worked
well.  However, between May 24 and 28, the right air temperature probe
malfunctioned continuously again.  The right air temperature probe
malfunctioned intermittently between May 28 and June 1, as well as
during short periods on June 5 and 6.  The cause of these latter periods is
unknown; the time periods do not correspond with any Site Operations
activities.  During the intermittent periods the data that is not offscale
should be viewed as questionable, as it is not always easy to detect what
effect the malfunction might have had on that data.

The malfunction of the right air temperature probe results in incorrect Bowen
ratio, sensible heat flux, and latent heat flux during the periods indicated.

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_r

30 minute: tair_top, tair_bot, bowen, e, h.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D950626.5
Start DateStart TimeEnd DateEnd Time
03/06/1995220503/07/19952230
Subject:
SGP/EBBR/E26 - Frozen Wind Speed Sensor
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On March 6, 1995 freezing rain stopped the cups of the EBBR wind
speed instrument at Cement, OK (E26).  All 5, 15, and 30
minute data values indicated below are incorrect for the period listed.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D950626.6
Start DateStart TimeEnd DateEnd Time
03/07/1995024503/08/19951640
Subject:
SGP/EBBR/E9 - Frozen Wind Speed Sensor
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
On March 7, 1995 freezing rain stopped the cups of the EBBR wind
speed instrument at Ashton, KS (E9).  All 5, 15, and 30
minute data values indicated below are incorrect for the period listed above.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D950626.8
Start DateStart TimeEnd DateEnd Time
03/11/1995010003/11/19950600
03/11/1995153003/12/19951930
03/13/1995043003/13/19950500
03/16/1995183003/18/19951100
03/19/1995210003/20/19950400
03/20/1995153003/20/19951700
03/10/1995210003/10/19952130
Subject:
SBP/EBBR/E9 - Reprocess: Soil Heat Flow Sensor 5 Incorrect Data
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
Soil heat flow sensor #5 periodically outputted incorrect values during the
period above.  The output often indicated large negative heat flow.  The
sensor connections were tightened on March 20, 1995, which seems to have
corrected the problem.  The data affected (and thus incorrect) includes:

15 minute: mv_hft5
30 minute: shf5, c_shf5, g5, ave_shf, e, h.

The dates and times (GMT) of incorrect values are listed below.  Only half
hour times are listed.

03/10/95  2130
03/11/95  0100-0600, 1530-2330
03/12/95  0000-1930
03/13/95  0500
03/16/95  1830-2330
03/17/95  0000-2330
03/18/95  0000-1100
03/19/95  2100-2330
03/20/95  0000-0400, 1530-1700

The latent and sensible heat fluxes can be recalculated by using only soil
heat flows 1 through 4 to calculate the average soil heat flow,

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q)
Measurements:sgp30ebbrE9.b1:
  • soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • corr_soil_heat_flow_5

sgp15ebbrE9.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D950626.9
Start DateStart TimeEnd DateEnd Time
03/17/1995200003/19/19950500
03/19/1995190504/12/19951430
Subject:
SGP/EBBR/E26 - Frozen Wind Speed Sensor
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
A broken lead on the EBBR wind speed instrument cable at Cement, OK (E26)
resulted in the loss of wind speed data.  It was nearly a month before the
cable could be repaired and reinstalled.  All 5, 15, and 30
minute data values indicated below are incorrect for the periods listed above.

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D950908.2
Start DateStart TimeEnd DateEnd Time
08/26/1995034509/12/19952000
Subject:
SGP/EBBR/E26 - AEM not exchanging
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On August 26, 1995 at approximately 0345 GMT the gears on the lower sprocket
shaft of the AEM appear to have been damaged, causing the AEM to stop
exchanging.  The home signal values then remained at around -0.5 for both
home_15 and Home_30.  On August 29 site operations personnel removed the fuse
(to prevent exchange) with the left aspirator in the down position.  The AEM
will remain in this condition until a replacement is available.

Therefore, the calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for all times after August 26, 1995 at 0345 GMT.  The data
fields listed below are incorrect after this time:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top,
           hum_bot, vp_top, vp_bot, Bowen, e, h.

It is not possible to reliably calculate the Bowen ratio, e, and h using the
15 minute data.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D950921.4
Start DateStart TimeEnd DateEnd Time
08/26/1995034509/12/19952000
Subject:
SGP/EBBR/E26 - AEM replacement
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Please see DQR P950908.2, where this problem was first documented.

On August 26, 1995 at approximately 0345 GMT the gears on the lower sprocket
shaft of the AEM appear to have been damaged, causing the AEM to stop
exchanging.  The home signal values then remained at around -0.5 for both
home_15 and Home_30.  On August 29 site operations personnel removed the fuse
(to prevent exchange) with the left aspirator in the down position.

On 12 September 1995 the AEM was replaced at 1959 GMT (old S/N 92004,
new S/N 92008) and is functioning properly.

Calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for all times during the period above.  The data
fields listed below are incorrect during the period:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top,
           hum_bot, vp_top, vp_bot, Bowen, e, h.

It is not possible to reliably calculate the Bowen ratio, e, and h using the
15 minute data.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D951016.1
Start DateStart TimeEnd DateEnd Time
09/27/1995210010/13/19951230
Subject:
SGP/EBBR/E26 - Battery Voltage Drop
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Shortly after the PM visit on September 26, 1995 the EBBR battery voltage at
E26, Cement, OK declined to lower than acceptable levels.  During the October
13, 1995 PM visit the battery was replaced.  I do not know the specifics of why
the battery voltage declined so suddenly, but failure of one or more of the
battery cells is a possibility.  I have not received the site operations log of
the PM visit yet.  The voltage dropped to 10 volts at night.  At various times,
soil temperature, soil heat flux plate output, and atmospheric pressure (at
least) were not reported correctly by the CR10 datalogger.

Amazingly, the AEM continued to work and reported millivolt outputs that
did not fall below the acceptable ranges.

All data between 2100 GMT on September 26, 1995 and 1230 GMT on October 13,
1995 should be considered suspect, particularly when the battery voltage
fell below 11 volts (every nighttime).  This general caution is issued
because incorrect reporting of data also took place during times when the
battery voltage was reported as 12 Volts, a normally acceptable level;
the reason for this behavior is unknown.
Measurements:sgp30ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_temp_3_rr
  • soil_temp_2_rr
  • atmos_pressure_mv
  • soil_temp_1_rr

sgp5ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D951016.2
Start DateStart TimeEnd DateEnd Time
09/12/1995000010/13/19951230
Subject:
SGP/EBBR/E26 - Net Radiometer Dome Punctured
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The upper dome of the net radiometer was punctured sometime between the PM
visits of September 12 and 26, 1995.  After the puncture, water collected
in the top hemisphere.  The water was removed on September 26, but a
replacement dome was not available.  The dome was replaced during the PM
visit on October 13, 1995.  The puncture and water did not result in
obviously incorrect data.  I cannot tell when the puncture occurred from
the data.  The data, particularly during the two weeks between September 12
and 26, 1995, should be considered suspect.

Suspect net radiation data results in the latent heat flux and sensible
heat flux also being suspect.  Suspect data then includes:

5 minute:  q

15 minute: mv_q

30 minute: q, e, h.
Measurements:sgp30ebbrE26.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • net_radiation_mv

sgp5ebbrE26.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D951020.1
Start DateStart TimeEnd DateEnd Time
10/05/1995153010/05/19951830
Subject:
SGP/EBBR/E9 - 3-month Check
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D951113.4
Start DateStart TimeEnd DateEnd Time
11/01/1995154511/01/19951845
Subject:
SGP/EBBR/E26 - Right Tair Offscale
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
On 1 November 1995 at E26, Cement, OK EBBR the right thermocouple output
went offscale for a few hours.  The cause for this is unknown and the
sensor recovered fully.  Incorrect data for the period above includes:

5 minute:   tair_top, tair_bot

15 minute:  tair_r, tair_l

30 minute:  tair_top, tair_bot, bowen, h, e
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D951116.3
Start DateStart TimeEnd DateEnd Time
11/11/1995024011/11/19951505
Subject:
SGP/EBBR/E26 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
Freezing rain, snow, and below freezing conditions during the night of 10-11
November 1995 resulted in the wind speed sensor cups becoming frozen in a
stopped state at E26, Cement, OK on early 11 November 1995.  When temperatures
rose to almost freezing under cloudless skies later in the day, the ice thawed
and the cups were free to turn again.

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D951116.5
Start DateStart TimeEnd DateEnd Time
11/11/1995014511/11/19951600
Subject:
SGP/EBBR/E9 - AEM Exchange Stopped in Snow and Freezing Rain
DataStreams:sgp30ebbrE9.b1
Description:
On the night of November 10-11, a north-south line from south central
Kansas through south central Oklahoma received snow and freezing rain and experienced 
below freezing temperatures.  This caused the EBBR automatic exchange mechanism (AEM) to stop 
exchanging temporarily.   

Note that temperatures, relative humidities, and vapor pressures are not affected; these 
are correct as measured, but the height at which the measurements occurred must be 
determined from the home signal value.
Measurements:sgp30ebbrE9.b1:
  • bowen_ratio
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)


Back To Table of Contents

DQRID : D951127.1
Start DateStart TimeEnd DateEnd Time
11/15/1995123011/15/19952100
Subject:
SGP/EBBR/E9 - Annual calibration changeout
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
On November 15, 1995 the changeout for annual calibration occurred at E9,
Ashton, KS.  SEBS unit 4 was removed and unit 6 was installed.  Between
1230 and 2100 GMT no data was collected; data during this period is missing.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • Barometric Pressure(atmos_pressure)
  • home_signal_30
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_temp_4
  • soil_temp_5
  • energy_storage_change_5
  • Wind speed vector mean(wspd_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Radiation, net(net_radiation)
  • rh_top_fraction
  • base_time
  • lon
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • temp_trh_top
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • wdir_vec_std
  • soil_heat_flow_5
  • temp_reference
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_4
  • vapor_pressure_bottom
  • soil_heat_flow_3
  • temp_air_bottom
  • soil_moisture_1
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_moisture_3
  • soil_moisture_2
  • soil_moisture_5
  • soil_moisture_4
  • alt
  • time_offset
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_1
  • rh_bottom_fraction
  • home_signal_15
  • vapor_pressure_top
  • temp_trh_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • lat
  • bowen_ratio
  • temp_air_top

sgp5ebbrE9.b1:
  • temp_reference
  • alt
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Barometric Pressure(atmos_pressure)
  • lon
  • lat
  • Wind speed vector mean(wspd_vec_mean)
  • temp_trh_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • base_time
  • vapor_pressure_top
  • temp_trh_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_air_top
  • Radiation, net(net_radiation)
  • vapor_pressure_bottom
  • wdir_vec_std
  • time_offset
  • home_signal


Back To Table of Contents

DQRID : D960104.2
Start DateStart TimeEnd DateEnd Time
12/18/1995211012/19/19951425
Subject:
SGP/EBBR/E26 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
Freezing rain, snow, and below freezing conditions during 18-19 January
1995 caused the wind speed sensor cups to freeze in a stopped state at E26,
Cement, OK on 18 January 1995.  When temperatures rose to above freezing on
19 January, the ice thawed and the cups turned freely again.

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D960104.8
Start DateStart TimeEnd DateEnd Time
12/26/1995163012/31/19951930
Subject:
SGP/EBBR/E26 - Right Tair Offscale
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
On 26 and 31 December 1995 at E26, Cement, OK EBBR the right thermocouple
output went offscale.  The cause for this is unknown and the sensor recovered
fully.  Five minute data would need to be inspected during the periods
above for incorrect five minute values.  Site Operations has been asked to
check the sensor connections.  Incorrect data for the period indicated includes:

5 minute:   tair_top, tair_bot

15 minute:  tair_r

30 minute:  tair_top, tair_bot, bowen, h, e
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D960119.3
Start DateStart TimeEnd DateEnd Time
01/04/1996151501/05/19960430
01/07/1996201501/07/19962330
01/08/1996154501/09/19961330
01/09/1996200001/09/19962030
Subject:
SGP/EBBR/E26 - Right tair Offscale
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
On five days in January 1996 at E26, Cement, OK EBBR the right thermocouple
output went offscale.  The cause for this is unknown, although poor probe
connections are common.  Site Operation personnel tightened the probe
connections in mid January.

Five minute data would need to be inspected during the periods
indicated for incorrect five minute values.  Incorrect data for the period
indicated includes:

5 minute:   tair_top, tair_bot

15 minute:  tair_r

30 minute:  tair_top, tair_bot, bowen, h, e

The data are not recoverable from other measurements.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D960321.1
Start DateStart TimeEnd DateEnd Time
01/23/1996045001/23/19961555
Subject:
SGP/EBBR/E9 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
Freezing rain, snow, and below freezing conditions during 23 January 
1996 caused the wind speed sensor cups to freeze in a stopped state at E9, 
Ashton, KS.  Site operations personnel removed the ice from the cups later 
in the day to allow them to turn freely again. 

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D960409.1
Start DateStart TimeEnd DateEnd Time
04/01/1996171504/01/19961830
Subject:
SGP/EBBR/E26 - Right Air Temperature Malfunction
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The right air temperature probe malfunctioned and produced incorrect data 
during the period of time indicated above.  The cause of the problem is 
unknown.  The right air temperature probe appears to be working well presently.

The malfunction of the right air temperature probe results in incorrect Bowen 
ratio, sensible heat flux, and latent heat flux during the period above. 

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_r (1715-1830 GMT values)

30 minute: tair_top, tair_bot, bowen, e, and h (1730-1830 GMT values)
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D960501.4
Start DateStart TimeEnd DateEnd Time
04/23/1996150004/23/19962115
Subject:
SGP/EBBR/E26 - Right Air Temp Malfunction
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The right air temperature probe malfunctioned and produced incorrect data 
during the period of time indicated above.  The probe (S/N 92013) was 
replaced by Site Operations on 23 April 1996 at 2115 GMT with S/N 92002.  

The malfunction of the right air temperature probe results in incorrect Bowen 
ratio, sensible heat flux, and latent heat flux during the period indicated. 

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_r (1515-2115 GMT values)

30 minute: tair_top, tair_bot, bowen, e, and h (1530-2130 GMT values)
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D960508.10
Start DateStart TimeEnd DateEnd Time
04/09/1996182004/09/19962000
Subject:
SGP/EBBR/E26 - 3-month check
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D960508.4
Start DateStart TimeEnd DateEnd Time
04/30/1996173104/30/19961800
Subject:
SGP/EBBR/E9 - 3-month check
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp30ebbrE9.b1:
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • bowen_ratio
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • rh_bottom_fraction
  • temp_air_bottom


Back To Table of Contents

DQRID : D961122.10
Start DateStart TimeEnd DateEnd Time
09/20/1996143009/20/19961500
Subject:
SGP/EBBR/E9 - Air Temperature Thermocouples Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
Both air temperature thermocouples were offscale, for unknown reasons, for 
1500 GMT for both 15 and 30 minute air temperature values.

The malfunction of the air temperature thermocouples results in incorrect Bowen 
ratio, sensible heat flux, and latent heat flux during the period above. 

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_r, tair_l

30 minute: tair_top, tair_bot, bowen, e, and h
Measurements:sgp30ebbrE9.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE9.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D961122.12
Start DateStart TimeEnd DateEnd Time
07/24/1996101508/13/19961800
Subject:
SGP/EBBR/E26 - Wind Direction Sensor Failure
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Wind Direction and resultant wind speed data for the period listed above 
is incorrect.  Wind direction would not record outside 0 to 20 degrees.  
This is a common malfunction in this style of wind direction sensor.  
The sensor was replaced on 13 August 1996.  The old sensor S/N was K3038
and new sensor is S/N K3033.  The affected data values are:

 5 minute: wind_d, sigma_wd, res_ws

15 minute: mv_wind_d

30 minute: wind_d, sigma_wd, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D961122.13
Start DateStart TimeEnd DateEnd Time
05/12/1996000007/05/19962359
Subject:
SGP/EBBR/E26 - Right Air Temperature Malfunction
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
The right air temperature probe malfunctioned again and produced 
incorrect data (outside of range) during some of the period indicated above.  
The cause of the problem is unknown.  On 18 June site operations tightened the
connection to the J-panel and repaired a broken aspirator fan wire.  However, 
incorrect data resumed shortly after site operations left the site.  Data 
continued to be incorrect during some times through July 5.  No incorrect data 
was recorded from July 6 through July 17.  The EBBR unit was changed out on 
July 17, 1996.

The times of incorrect right air temperatures are easy to recognize from 
the EBBR data, so the precise times of incorrect data are not enumerated 
here.  Typically, the top and bottom air temperature is out of range, 
resulting in the sensible heat flux being zero.

The malfunction of the right air temperature probe results in incorrect Bowen 
ratio, sensible heat flux, and latent heat flux. 

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_r 

30 minute: tair_top, tair_bot, bowen, e, and h
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D961122.22
Start DateStart TimeEnd DateEnd Time
11/15/1996155711/15/19961630
Subject:
SGP/EBBR/E9 - EBBR 3 Month Checks - 10 EFs
DataStreams:sgp15ebbrE9.b1, sgp5ebbrE9.b1, sgp30ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D961122.28
Start DateStart TimeEnd DateEnd Time
10/24/1996155010/24/19961613
Subject:
SGP/EBBR/E26 - EBBR 3 Month Checks - 10 EFs
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D961122.4
Start DateStart TimeEnd DateEnd Time
07/16/1996150007/16/19962230
Subject:
SGP/EBBR/E26 - Annual Calibration Changeout
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On 16 November 1996 the EBBR changeout for annual calibration occurred at 
E26, Cement, OK.  SEBS unit 2 was removed and unit 8 was installed.  Between 
1500 and 2230 GMT no data or incorrect data was collected; most of the data 
is missing.  3 month calibration checks were being performed.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time


Back To Table of Contents

DQRID : D961122.5
Start DateStart TimeEnd DateEnd Time
11/06/1996200011/19/19961830
Subject:
SGP/EBBR/E26 - Wind Direction Sensor Failure
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Wind Direction and resultant wind speed data for much of the period listed 
above is incorrect.  Wind directions of 135, 0, or 360 would continue for 
extended periods.  This behavior is indicative of a failed sensor.    
This is a common malfunction in this style of wind direction sensor.  
A work request has been submitted to site operations for replacement of the 
sensor.  All values of 135, 0, and 360 should be considered to be 
incorrect during the period above.  Furthermore, more incorrect data may 
occur until the sensor is replaced (by 6 December).

The affected data values are:

 5 minute: wind_d, sigma_wd, res_ws

15 minute: mv_wind_d

30 minute: wind_d, sigma_wd, res_ws
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D970330.6
Start DateStart TimeEnd DateEnd Time
11/06/1996200011/19/19961825
Subject:
SGP/EBBR/E26 - Wind Direction Sensor Failure
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp15ebbrE26.b1
Description:
Wind Direction and Sigma of Wind Direction data for the period listed  
is incorrect.  The wind direction sensor began to malfunction on 6 November, 
with the characteristic constant 135 degree output.  At other times the output
remained a nearly constant 230 to 240 degrees.  On 16 November at 1819 GMT site
operations replaced sensor  S/N 3033 with S/N 3036.  Apparently they left it 
aligned at north when they left the EF; output for the next few days was 0 or 
360 degrees, until they returned on 19 November at 1825 GMT and gave the vane 
it's freedom.

Affected fields are:

5 minute: wind_d, sigma_wd

15 minute: mv_wind_d

30 minute: wind_d, sigma_wd
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D970623.2
Start DateStart TimeEnd DateEnd Time
07/15/1996171506/18/19971645
Subject:
SGP/EBBR/E9 - Temperature Portion of T/RH Probe
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1
Description:
The Temperature portion of the right T/RH probe indicated too high a 
temperature for nearly 11 months.  I twice placed work requests to have the 
probe replaced, but no spares were available.  Spares recently became 
available and I placed a new work request to have the probe changed.  The 
replacement occurred on 18 June 1997; this fixed the problem.  The main 
results of the high temperatures were probe top and bottom temperatures
(used only for the calculation of vapor pressure) and vapor pressures that 
were too large.  Furthermore, this caused latent heat flux to be reported 
to be too large, and therefore sensible heat flux was reported to be too 
small.  Recalculation of the fluxes using thermocouple temperatures to 
calculate vapor pressure would be quite time consuming and would have to
assume that the thermocouple temperature and probe temperature were nearly 
the same.

The EBBR procedures have been changed to include comparison of the 
thermocouple and probe temperatures to make it easier for the site 
operators to detect this condition.

The data affected (and thus incorrect) includes:

15 minute: rr_thum_r 
30 minute: thum_top, thum_bot, vp_top, vp_bot, e, h, bowen.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_bottom
  • bowen_ratio

sgp15ebbrE9.b1:
  • base_time
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • lat
  • battery_voltage
  • soil_heat_flow_4_mv
  • lon
  • soil_heat_flow_5_mv
  • soil_heat_flow_3_mv
  • alt
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D970627.2
Start DateStart TimeEnd DateEnd Time
12/03/1996193006/17/19972030
Subject:
SGP/EBBR/E26 - Reprocess: E26 Soil Heat Flow Sensor 1 Replacement
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Apparently, during installation of the present system on 17 July 1996, soil 
heat flow sensor #4 was intentionally placed upside down in the soil to 
produce the correct sign of flux. The leads from the sensor must have been
connected with the wrong polarity.  On 3 December 1996 site operations 
corrected some wiring problems and reconnected soil heat flow sensor #4 
according to the proper color code; this caused the sign of the soil heat 
flow from that sensor to then be opposite of the other four sensors.  All 
data from sensor #4 is the wrong sign during the period listed above.

On 17 June 1997 site operations removed the sensor and installed it with 
the correct side up, fixing the problem.

The result of this problem was a decrease of reported average soil heat flow of 
approximately 40%.  This translates into a 0 to 20% error in latent and 
sensible heat fluxes (soil heat flow is rarely more than 50% of net radiation,
upon which the Bowen ratio calculation depends).  Therefore, sensible and 
latent heat fluxes were typically overestimated by about 10% during the 
daytime.  This is of the same magnitude as the EBBR system/technique error.

The following data values were affected for the period listed 
above: 

15 minute: mv_hft4
30 minute: shf4, c_shf4, g4, ave_shf, e, h

The latent and sensible heat fluxes can be recalculated by using only soil
heat flows 1, 2, 3, and 5 to calculate the average soil heat flow,

ave_shf = (g1 + g2 + g3 + g5)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(e + ave_shf + q).
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_4
  • soil_heat_flow_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv


Back To Table of Contents

DQRID : D971021.3
Start DateStart TimeEnd DateEnd Time
04/15/1997184504/15/19971915
Subject:
SGP/EBBR/E9 - EBBR Biannual Checks
DataStreams:sgp15ebbrE9.b1, sgp5ebbrE9.b1, sgp30ebbrE9.b1
Description:
During EBBR 6 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D971021.9
Start DateStart TimeEnd DateEnd Time
04/23/1997200804/23/19972050
Subject:
SGP/EBBR/E26 - EBBR Biannual Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D971027.8
Start DateStart TimeEnd DateEnd Time
08/10/1997000009/30/19971550
Subject:
SGP/EBBR/E9 - Wind Direction Sensor Malfunction
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
During numerous intermittent times during the period listed, the wind direction
sensor at E9, Ashton, KS malfunctioned, putting out a value of 135.  The
sensor was replaced on 30 September 1997, at 1550 GMT.  All wind direction data
with values of 135 during the period listed should be considered incorrect.
The affected data are:

 5 minute: res_ws, wind_d, sigma_d

15 minute: mv_wind_d

30 minute: res_ws, wind_d, sigma_d
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE9.b1:
  • wdir_vec_mean_mv

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D971027.9
Start DateStart TimeEnd DateEnd Time
09/10/1997000009/10/19972359
Subject:
SGP/EBBR/E26 - Bad Dates
DataStreams:sgp30ebbrE26.b1
Description:
At the end of the netcdf 30 minute file for 10 September 1997 there are two
half hours with date 9 September 1997, and time 2200 GMT.  It is unknown
how this happens, but it does occasionally. Those two half hour records
should be ignored.
Measurements:sgp30ebbrE26.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • Wind speed vector mean(wspd_vec_mean)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • rh_top_fraction
  • bowen_ratio
  • soil_heat_capacity_1
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • home_signal_30
  • lat
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • temp_air_top
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • base_time
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D980117.13
Start DateStart TimeEnd DateEnd Time
12/21/1997071512/21/19971115
01/04/1998074501/05/19981710
01/09/1998094501/09/19981610
Subject:
SGP/EBBR/E9 - EBBR Frozen Wind Speed
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D980117.22
Start DateStart TimeEnd DateEnd Time
01/07/1998195001/08/19982230
Subject:
SGP/EBBR/E26- EBBR Frozen Wind Speed
DataStreams:sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980117.25
Start DateStart TimeEnd DateEnd Time
01/04/1998184501/08/19981715
Subject:
SGP/EBBR/E9 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)
DataStreams:sgp15ebbrE9.b1, sgp5ebbrE9.b1, sgp30ebbrE9.b1
Description:
The EBBR AEM stopped exchanging because of icing at during this time
period.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for the time period indicated.  The other
measurements listed  are also incorrect for those times:
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D980117.31
Start DateStart TimeEnd DateEnd Time
12/24/1997163001/08/19981800
Subject:
SGP/EBBR/E9 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affected
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
The upper dome of the EBBR net radiometers was punctured.
After the puncture, water collected in the top and/or bottom dome.  The
water was removed and the dome was replaced during PM visits. 

 In some cases, the puncture and water resulted in incorrect data. 
Comparison with net radiation values from surrounding EBBR sites and the
SIRS is neccesary to determine if the EBBR net radiation data 
are correct or incorrect.

It is often difficult to tell from the data when the punctures occurred,
but they would have existed for no more than 2 weeks, since the domes
are checked during each two-weekly PM visit.

Incorrect net radiation data results in the latent heat flux and
sensible heat flux also being incorrect.
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D980117.33
Start DateStart TimeEnd DateEnd Time
12/16/1997200012/29/19971840
Subject:
SGP/EBBR/E26 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affected
DataStreams:sgp5ebbrE26.b1, sgp30ebbrE26.b1, sgp15ebbrE26.b1
Description:
The upper dome of the EBBR net radiometers was punctured.
After the puncture, water collected in the top and/or bottom dome.  The
water was removed and the dome was replaced during PM visits. 

 In some cases, the puncture and water resulted in incorrect data. 
Comparison with net radiation values from surrounding EBBR sites and the
SIRS is neccesary to determine if the EBBR net radiation data 
are correct or incorrect.

It is often difficult to tell from the data when the punctures occurred,
but they would have existed for no more than 2 weeks, since the domes
are checked during each two-weekly PM visit.

Incorrect net radiation data results in the latent heat flux and
sensible heat flux also being incorrect.
Measurements:sgp30ebbrE26.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE26.b1:
  • net_radiation_mv

sgp5ebbrE26.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D980117.5
Start DateStart TimeEnd DateEnd Time
01/08/1998010001/08/19982030
Subject:
SGP/EBBR/E26 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The EBBR AEM stopped exchanging because of icing at during this time
period.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for the time period indicated.  The other
measurements listed  are also incorrect for those times:
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980410.5
Start DateStart TimeEnd DateEnd Time
01/14/1998050001/15/19980030
Subject:
SGP/EBBR/E9 - Wind Speed Sensor Frozen
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
Description:
The wind speed sensor was frozen stalled during this period. 

Data values that were affected are:

 5 minute: wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp5ebbrE9.00:
  • Raw data stream - documentation not supported

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D980416.10
Start DateStart TimeEnd DateEnd Time
10/16/1997192810/16/19972002
Subject:
SGP/EBBR/E9 - 3-Month Check
DataStreams:sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp15ebbrE9.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period above.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D980416.18
Start DateStart TimeEnd DateEnd Time
10/21/1997212510/21/19972148
Subject:
SGP/EBBR/E26 - 3-Month Check
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period indicated.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980507.5
Start DateStart TimeEnd DateEnd Time
06/18/1997013006/18/19970200
Subject:
SGP/EBBR/E26 - Character In EBBR E26, 30 Minute Data
DataStreams:sgp30ebbrE26.b1
Description:
A non-numeric character appears in the field for shf1 in 
the 30 minute data file at the time shown. Data
processing programs that assume that a numeric character
is there will display an error condition.  I had to
create a short routine to put in my analysis program to
avoid using that data point.
Measurements:sgp30ebbrE26.b1:
  • soil_heat_flow_1


Back To Table of Contents

DQRID : D980529.17
Start DateStart TimeEnd DateEnd Time
05/19/1998164605/19/19981717
Subject:
SGP/EBBR/E26 - Six Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period indicated.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D980529.8
Start DateStart TimeEnd DateEnd Time
05/14/1998174005/14/19981759
Subject:
SGP/EBBR/E9 - Six Month Checks
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period above.
Measurements:sgp30ebbrE9.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom
  • vapor_pressure_top
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_air_right
  • rh_right_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_air_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents

DQRID : D990127.12
Start DateStart TimeEnd DateEnd Time
11/12/1998210011/25/19981830
Subject:
SGP/EBBR/E9 - Wind Direction Data Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
Description:
The wind direction sensor stopped working correctly, resulting in the
following values being affected:

5 minute:  res_ws, wind_d, sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp5ebbrE9.00:
  • Raw data stream - documentation not supported

sgp15ebbrE9.b1:
  • wdir_vec_mean_mv

sgp5ebbrE9.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std


Back To Table of Contents

DQRID : D990127.31
Start DateStart TimeEnd DateEnd Time
01/08/1999083501/08/19991600
Subject:
SGP/EBBR/E26 - Wind Direction Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind direction sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  res_ws, wind_d, sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990127.42
Start DateStart TimeEnd DateEnd Time
12/21/1998070512/24/19981630
01/08/1999031501/09/19990600
Subject:
SGP/EBBR/E26 - Wind Speed Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp15ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE26.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990127.43
Start DateStart TimeEnd DateEnd Time
01/08/1999031501/09/19990600
Subject:
SGP/EBBR - EBBR E26 Wind Speed Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D990127.7
Start DateStart TimeEnd DateEnd Time
01/09/1999020001/14/19991830
Subject:
SGP/EBBR/E26 - Battery Voltage Low, Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
Battery voltages less than 10.4 volts occurred some of the time.  All data
should be considered incorrect when the voltage is less than 10.4 volts.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D990127.8
Start DateStart TimeEnd DateEnd Time
11/12/1998123011/12/19982000
Subject:
SGP/EBBR/E9 - EBBR E9 Net Radiometer Dome Broken, Flux Data Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
Description:
Incorrect Net Radiation values resulted in incorrect sensible and 
latent heat fluxes. Affected values are:

5 minute:   q
15 minute:  mv_q
30 minute:  q, e, h
Measurements:sgp30ebbrE9.b1:
  • Radiation, net(net_radiation)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)

sgp5ebbrE9.00:
  • Raw data stream - documentation not supported

sgp15ebbrE9.b1:
  • net_radiation_mv

sgp5ebbrE9.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D990128.6
Start DateStart TimeEnd DateEnd Time
01/01/1999151501/03/19991830
Subject:
SGP/EBBR/E9 - Wind Speed Data Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp5ebbrE9.00:
  • Raw data stream - documentation not supported

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D990128.7
Start DateStart TimeEnd DateEnd Time
01/08/1999060501/08/19991900
Subject:
SGP/EBBR/E9 - Wind Speed Data Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp5ebbrE9.00:
  • Raw data stream - documentation not supported

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D990129.5
Start DateStart TimeEnd DateEnd Time
12/30/1998030012/30/19981300
Subject:
SGP/EBBR/E26 - Battery Voltage Low
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
Battery voltage dropped below 10.4 volts.  All data should be considered to
be incorrect.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D990409.6
Start DateStart TimeEnd DateEnd Time
04/01/1999141504/02/19991645
Subject:
SGP/EBBR/E26 - Calibration Changeout
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
The data from this period was either missing or incorrect during the
calibration changeout of the EBBR unit.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D990421.2
Start DateStart TimeEnd DateEnd Time
04/02/1999164504/02/19991800
Subject:
SGP/EBBR/E26 - Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgpebbrE26.00, sgp5ebbrE26.00
Description:
All data is incorrect for this time.  This problem was related
to changeout activities.
Measurements:sgpebbrE26.00:
  • Raw data stream - documentation not supported

sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D990622.5
Start DateStart TimeEnd DateEnd Time
04/22/1999075004/29/19991850
Subject:
SGP/EBBR/E9 - Wind Speed Incorrect
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1, sgp5ebbrE9.00
Description:
The wind speed sensor lost two of the three cups.  Flux data is not 
affected.  The data values affected are:

5 minute: wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)

sgp5ebbrE9.00:
  • Raw data stream - documentation not supported

sgp15ebbrE9.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE9.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)


Back To Table of Contents

DQRID : D990622.6
Start DateStart TimeEnd DateEnd Time
04/15/1999183004/15/19991900
Subject:
SGP/EBBR/E26 - Battery Wire Problem Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
The battery voltage dropped suddenly to 8 volts at 1900 GMT, making all
data incorrect for that time.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D990622.7
Start DateStart TimeEnd DateEnd Time
04/28/1999224504/29/19990600
Subject:
SGP/EBBR/E26 - Battery Wire Problem Causes Questionable Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1, sgp5ebbrE26.00
Description:
The battery voltage dropped to less than 10.4 volts, causing all
data to be suspect for the time period.
Measurements:sgp30ebbrE26.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Radiation, net(net_radiation)
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • home_signal_30
  • lat
  • soil_temp_5
  • soil_heat_flow_3
  • soil_temp_4
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • time_offset
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • alt
  • Barometric Pressure(atmos_pressure)
  • base_time

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_2_mv
  • temp_trh_right_rr
  • battery_voltage
  • lon
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat
  • temp_air_left
  • alt
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • time_offset
  • soil_moisture_5_r
  • base_time
  • soil_temp_2_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • time_offset
  • rh_bottom_fraction
  • temp_reference
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • temp_trh_top
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_air_bottom
  • vapor_pressure_bottom
  • alt
  • vapor_pressure_top
  • Radiation, net(net_radiation)
  • lat
  • base_time

sgp5ebbrE26.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D990623.1
Start DateStart TimeEnd DateEnd Time
05/13/1999123006/11/19991645
Subject:
SGP/EBBR/E9 - Right Aspirator Not Working
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
The result of the right aspirator not working was a reduction in measured
temperature gradient and thus a reduction in estimated sensible heat flux
and an increase in latent heat flux.  The fluxes could be in error by as
much as 10%.  Reported right air and humidity probe temperatures, top and 
bottom air and humidity probe temperatures, right relative humidity, and 
top and bottom vapor pressure are affected.
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction

sgp15ebbrE9.b1:
  • temp_trh_right_rr
  • temp_air_right
  • rh_right_mv
  • rh_left_mv
  • temp_air_left
  • temp_trh_left_rr

sgp5ebbrE9.b1:
  • rh_top_fraction
  • temp_air_top
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_air_bottom
  • rh_bottom_fraction


Back To Table of Contents