Data Quality Reports for Session: 142588 User: kcwang Completed: 05/23/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D000221.8SGP/EBBR - EBBR E12 Anemometer Cups Frozen, Wind Speed Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D000225.10SGP/EBBR - EBBR E12 Net Radiation Incorrectsgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D000301.1SGP/EBBR - EBBR E12 Net Radiation Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D010213.1SGP/EBBR/E12 - EBBR E12 Wind Speed Icedsgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
D010213.2SGP/EBBR/E12 - EBBR E12 Wind Speed Icedsgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
D010402.13SGP/EBBR/E12 - E12 EBBR Wind Direction Incorrectsgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D010402.14SGP/EBBR/E12 - E12 EBBR Wind Speed Incorrectsgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
D010402.16SGP/EBBR/E12 - E12 EBBR AEM Stuck - Data Incorrectsgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
D011127.26SGP EBBR E12 - E12 EBBR Data Incorrect During 6 Month Checkssgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
D011207.11SGP EBBR E12 - E12 EBBR Data Incorrect From AEM In One Positionsgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
D020628.1SGP/EBBR/E12 - 3-month Checksgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D020628.15SGP/EBBR/E12 - T/RH Checksgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D020716.11SGP/EBBR/E12 - 6 Month Checkssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D020717.10SGP/EBBR/E12 - AEM Hungsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D020717.11SGP/EBBR/E12 - Measurements Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.00, sgp5ebbrE12.b1
D020717.12SGP/EBBR/E12 - Resistance Measurements Incorrectsgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D020717.6SGP/EBBR/E12 - Reprocess: Soil Temperature #3 Incorrectsgp30ebbrE12.b1
D020717.7SGP/EBBR/E12 - Wind Direction Incorrectsgp30ebbrE12.b1, sgp5ebbrE12.b1
D020717.8SGP/EBBR/E12 - Reprocess: Soil Moisture 4 and 5 Incorrectsgp30ebbrE12.b1
D020717.9SGP/EBBR/E12 - Reprocess: Soil Moisture 2 and 5 Incorrectsgp30ebbrE12.b1
D021113.1SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D021113.4SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D030110.33SGP/EBBR/E12 - Data Incorrect during 6 month checkssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D030114.11SGP/EBBR/E12 - Resistance-based Measurements Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D030114.12SGP/EBBR/E12 - Wind Direction Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D030114.13SGP/EBBR/E12 - Data zero following Logger Restartsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D030114.14SGP/EBBR/E12 - Battery Voltage Lowsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D030114.19SGP/EBBR/E12 - AEM Stuck in One Positionsgp30ebbrE12.b1
D030115.2SGP/EBBR/E12 - REPROCESS: Net Rad Calibration Coefficientssgp30ebbrE12.b1, sgp5ebbrE12.b1
D030115.3SGP/EBBR/E12 - Data Mostly Zero Following Logger Restartsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D030711.21SGP/EBBR/E12 - AEM Hung Inbetween Home Positionssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D030712.16SGP/EBBR/E12 - 6 Month Checkssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D031031.4SGP/EBBR/E12 - Water in Net Radiometer, Surface Fluxes Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D031124.12SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltagesgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D031204.9SGP/EBBR/E12 - 6 Month Checkssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D031217.4SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltagesgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D031222.15SGP/EBBR/E12 - Wind Speed Sensor Frozen By Ice Stormsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D040304.10SGP/EBBR/E12 - Wind Speed Frozen Stopped By Icesgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D040304.11SGP/EBBR/E12 - Wind Direction Frozen Stopped By Icesgp30ebbrE12.b1, sgp5ebbrE12.b1
D040615.3SGP/EBBR/E12 - Incorrect Timessgp15ebbrE12.b1, sgp30baebbrE12.c1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgpebbrE12.00
D041222.11SGP/EBBR/E12 - 6 Month Checkssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D041222.2SGP/EBBR/E12 - AEM home_15 Incorrect, Flux Measurements not affectedsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D050206.9SGP/EBBR/E12 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D050207.5SGP/EBBR/E12 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D050215.16SGP/EBBR/E12 - Wind Speed Frozen Stopped By Icesgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D050215.17SGP/EBBR/E12 - Wind Direction Frozen Stopped By Icesgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D050304.1SGP/EBBR/E12 - Wind Speed and Direction Frozen by Ice Stormsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D050719.9SGP/EBBR/E12 - Improved EBBR CR10 Programsgp30ebbrE12.b1
D051106.23SGP/EBBR/E12 - Average Soil Heat Flux Incorrectsgp30ebbrE12.b1
D051111.10SGP/EBBR/E12 - metadata correctionssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D060111.5SGP/EBBR/E12 - Sensible and Latent Heat Fluxes Incorrect at Timessgp15ebbrE12.b1, sgp30ebbrE12.b1
D060111.8SGP/EBBR/E12 - Multiplexer failuresgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D060501.11SGP/EBBR/E12 - Fluxes and Gradient Measurements Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D060921.3SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D060921.4SGP/EBBR/E12 - Soil Temperature #1 Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1
D061220.6SGP/EBBR/E12 - Wind Direction Dependency of Surface Fluxes and General Data Quality
Information
sgp30ebbrE12.b1
D090313.12SGP/EBBR/E12 - Wind Speed Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D100223.1SGP/EBBR/E12 - Wind Speed Sensor Frozen Stopped by Icingsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D100720.2SGP/EBBR/E12 - Intermittent data losssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D100720.3SGP/EBBR/E12 - Sensible and Latent Heat Fluxes and Other Measurements Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D101004.1SGP/EBBR/E12 - Net radiation too highsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D110830.1SGP/EBBR/E12 - Loose connection (SHF #4)sgp15ebbrE12.b1, sgp30ebbrE12.b1
D120307.1SGP/EBBR/E12 - Soil heat flux #4 intermittently incorrectsgp30ebbrE12.b1
D120507.5SGP/EBBR/E12 - Sensible and Latent Heat Fluxes Incorrectsgp30ebbrE12.b1
D940106.2SGP/EBBR/E12 - Invalid data due to blown AEM fuse at E12sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D940616.3SGP/EBBR/E12 - Wind Directionsgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D940711.3SGP/EBBR/E12 - Aspirator Failuresgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D940808.2SGP/EBBR/E12 - Stopped Ventilation Fansgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D940909.1SGP/EBBR/E12 - Miscellaneous Problems Affecting Datasgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D941021.12SGP/EBBR/E12 - Net Radiometer Hemisphere Changessgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
D941021.6SGP/EBBR/E12 - Low home_15 Valuessgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D950626.15SGP/EBBR/E12 - Wind Direction Malfunctionsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D950626.16SGP/EBBR/E12 - Wind Direction Malfunctionsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D950719.2SGP/EBBR/E12 - Wind Direction Malfunctionsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D950816.2SGP/EBBR/E12 - AEM Failuresgp30ebbrE12.b1, sgp5ebbrE12.b1
D950908.3SGP/EBBR/E12 - Wind Direction Malfunctionsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D950921.3SGP/EBBR/E12 - AEM replacementsgp30ebbrE12.b1, sgp5ebbrE12.b1
D951127.3SGP/EBBR/E12 - AEM Failure/Right Radiation Shield OFFsgp30ebbrE12.b1
D960320.3SGP/EBBR/E12 - Wind Speed Cups Frozensgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D960508.5SGP/EBBR/E12 - 3-month checksgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D961122.23SGP/EBBR/E12 - EBBR 3 Month Checks - 10 EFssgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
D961122.3SGP/EBBR/E12 - Annual Calibration Changeoutsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D961122.8SGP/EBBR/E12 - Left Air Temperature Thermocouple Incorrectsgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D961122.9SGP/EBBR/E12 - Battery Voltage Low - Fluxes Affectedsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D970401.1Controlled burn at E12 on 3/20/97 and affected datasgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgpsirosE12.a1
D970730.2SGP/EBBR/E12 - Wind Direction Sensor Malfunctionssgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D971021.4SGP/EBBR/E12 - EBBR Biannual Checkssgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
D980117.17SGP/EBBR/E12- EBBR Frozen Wind Speedsgp5ebbrE12.b1, sgp15ebbrE12.b1, sgp30ebbrE12.b1
D980117.26SGP/EBBR/E12 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
D980117.32SGP/EBBR/E12 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affectedsgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
D980117.6SGP/EBBR/E12 - AEM Failure and Replacementsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D980416.11SGP/EBBR/E12 - 3-Month Checksgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D980528.13SGP/EBBR/E12 - Wind Direction Sensor Failuresgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D980529.9SGP/EBBR/E12 - Six Month Checkssgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D990127.21SGP/EBBR/E12 - Wind Direction Data Incorrect (revised)sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D990128.1SGP/EBBR/E12 - Wind Speed Data Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D990128.2SGP/EBBR - EBBR E12 Wind Speed Data Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp5ebbrE12.00
D990129.1SGP/EBBR - EBBR E12 Wind Speed Data Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp5ebbrE12.00
D990129.2SGP/EBBR/E12 - Data Incorrectsgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp5ebbrE12.00, sgp15ebbrE12.b1
D990129.3SGP/EBBR/E12 - Temperature, RH, and Vapor Pressure Data Incorrectsgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
D990129.4SGP/EBBR/E12 - All Temperature Measurements Incorrectsgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
D990622.4SGP/EBBR/E12 - RH top Data Zerosgp30ebbrE12.b1


DQRID : D000221.8
Start DateStart TimeEnd DateEnd Time
12/21/1999000012/21/19991320
Subject:
SGP/EBBR - EBBR E12 Anemometer Cups Frozen, Wind Speed Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The anemometer cups were frozen stalled during this period.

The following values were therefore incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D000225.10
Start DateStart TimeEnd DateEnd Time
12/17/1999170012/27/19991845
Subject:
SGP/EBBR - EBBR E12 Net Radiation Incorrect
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
Condensation inside the domes (possibly water in the bottom dome also) 
during the period made daytime net radiation values as much as 50% too 
large and nighttime net radiations as much as 100% too small.  

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D000301.1
Start DateStart TimeEnd DateEnd Time
12/09/1999070012/14/19991500
Subject:
SGP/EBBR - EBBR E12 Net Radiation Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D010213.1
Start DateStart TimeEnd DateEnd Time
12/11/2000013012/15/20001630
Subject:
SGP/EBBR/E12 - EBBR E12 Wind Speed Iced
DataStreams:sgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
Description:
The anemometer was frozen stopped by freezing rain; the indicated data is incorrect.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D010213.2
Start DateStart TimeEnd DateEnd Time
12/18/2000073012/18/20001115
Subject:
SGP/EBBR/E12 - EBBR E12 Wind Speed Iced
DataStreams:sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
Description:
The anemometer was frozen stopped by freezing rain; the indicated data is incorrect.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D010402.13
Start DateStart TimeEnd DateEnd Time
12/18/2000064512/18/20001101
Subject:
SGP/EBBR/E12 - E12 EBBR Wind Direction Incorrect
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
The wind direction vane was frozen stopped in one direction by icing.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D010402.14
Start DateStart TimeEnd DateEnd Time
12/18/2000064512/18/20001101
Subject:
SGP/EBBR/E12 - E12 EBBR Wind Speed Incorrect
DataStreams:sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind speed sensor cups were frozen stopped by icing.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D010402.16
Start DateStart TimeEnd DateEnd Time
02/01/2000000002/08/20001531
Subject:
SGP/EBBR/E12 - E12 EBBR AEM Stuck - Data Incorrect
DataStreams:sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
Description:
The AEM became stuck between levels, causing all gradient measurements to be incorrect, 
and thus the latent and sensible heat fluxes and Bowen ratio.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D011127.26
Start DateStart TimeEnd DateEnd Time
04/03/2001162504/03/20011716
10/18/2001193010/18/20012116
Subject:
SGP EBBR E12 - E12 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE12.b1:
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_heat_flow_2_mv
  • soil_moisture_5_rr
  • soil_heat_flow_5_mv
  • soil_moisture_4_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • rh_right_mv
  • soil_moisture_3_rr
  • temp_trh_right_rr
  • soil_moisture_1_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • rh_left_mv
  • soil_moisture_2_rr
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • soil_moisture_5_r
  • net_radiation_mv
  • soil_heat_flow_3_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D011207.11
Start DateStart TimeEnd DateEnd Time
04/16/2001190004/17/20011631
04/17/2001233004/18/20011631
04/18/2001210004/20/20011301
04/20/2001213004/21/20010931
04/21/2001203004/26/20011501
04/27/2001003005/01/20011431
04/06/2001203004/11/20011731
Subject:
SGP EBBR E12 - E12 EBBR Data Incorrect From AEM In One Position
DataStreams:sgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
Description:
The AEM kept stopping in one position. Offset biases are not removed from the 
gradient data in this situation and the data indicated is therefore incorrect.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D020628.1
Start DateStart TimeEnd DateEnd Time
10/14/1995140010/14/19951700
Subject:
SGP/EBBR/E12 - 3-month Check
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D020628.15
Start DateStart TimeEnd DateEnd Time
11/23/1994151511/23/19941630
Subject:
SGP/EBBR/E12 - T/RH Check
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields
5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

5 minute:  1515, 1520, 1525, 1530, 1535, 1540, 1545, 1550, 1555,
           1600, 1605, 1610
15 minute: 1515, 1530, 1545, 1600, 1615
30 minute: 1530, 1600, 1630

(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D020716.11
Start DateStart TimeEnd DateEnd Time
04/30/2002154004/30/20021611
Subject:
SGP/EBBR/E12 - 6 Month Checks
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp15ebbrE12.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_air_top
  • temp_trh_top
  • rh_bottom_fraction
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D020717.10
Start DateStart TimeEnd DateEnd Time
01/30/2002043002/06/20021646
Subject:
SGP/EBBR/E12 - AEM Hung
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The automatic exchange mechanism did not exchange properly, causing other measurements to 
be incorrect.
Measurements:sgp15ebbrE12.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_bottom
  • rh_top_fraction
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_air_top
  • temp_trh_top
  • rh_bottom_fraction
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D020717.11
Start DateStart TimeEnd DateEnd Time
06/12/2002143006/12/20021501
Subject:
SGP/EBBR/E12 - Measurements Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.00, sgp5ebbrE12.b1
Description:
All measurements were incorrect or offscale for an unknown reason.
Measurements:sgp30ebbrE12.b1:
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_heat_flow_2_mv
  • soil_moisture_5_rr
  • soil_heat_flow_5_mv
  • soil_moisture_4_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • soil_moisture_3_rr
  • temp_trh_right_rr
  • soil_moisture_1_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • rh_left_mv
  • soil_moisture_2_rr
  • temp_air_left
  • soil_temp_1_rr
  • soil_temp_5_rr
  • net_radiation_mv
  • soil_heat_flow_3_mv

sgp5ebbrE12.00:
  • Raw data stream - documentation not supported

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D020717.12
Start DateStart TimeEnd DateEnd Time
06/28/2002180007/07/20022356
Subject:
SGP/EBBR/E12 - Resistance Measurements Incorrect
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
All sensors that depend on resistance measurements are incorrect.
Average soil heat flow, sensible heat flux, and latent heat flux are incorrect as a 
result.

This condition normally occurs when the reference temperature sensor is disconnected or 
bad.
Measurements:sgp15ebbrE12.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • soil_heat_capacity_5
  • energy_storage_change_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • bowen_ratio
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • soil_temp_5
  • corr_soil_heat_flow_3
  • soil_temp_4
  • soil_temp_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_temp_2
  • soil_temp_1
  • soil_moisture_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_top
  • vapor_pressure_top
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D020717.6
Start DateStart TimeEnd DateEnd Time
11/01/2001000006/20/20021231
Subject:
SGP/EBBR/E12 - Reprocess: Soil Temperature #3 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil Temperature #3 was flaky primarily during nighttime hours and sometimes during early 
daylight hours.  Average soil heat flow, sensible heat flux, and latent heat flux are 
also affected; these can be recalculated using the remaining good sets of soil sensors as 
follows:

The heat fluxes can be recalculated by using soil sets 1, 2, 4, and 5 as follows:
     ave_shf = (g1 + g2 + g4 + g5)/4
     e = -(q + ave_shf)/(1 + bowen)
     h = -(q + e + ave_shf)
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • soil_temp_3
  • energy_storage_change_3
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • surface_soil_heat_flux_3


Back To Table of Contents

DQRID : D020717.7
Start DateStart TimeEnd DateEnd Time
04/25/2002223006/30/20022356
Subject:
SGP/EBBR/E12 - Wind Direction Incorrect
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind direction measurement was zero, in the 50s, or always less than 180 degrees.

A DQPR has been issued to resolve the problem.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D020717.8
Start DateStart TimeEnd DateEnd Time
01/30/2002120001/30/20021201
Subject:
SGP/EBBR/E12 - Reprocess: Soil Moisture 4 and 5 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil moisture measurements from sets 4 and 5 were incorrect, leading to many other 
incorrect measurements calculated using them.

Average soil heat flow, sensible heat flux, and latent heat flux are affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
    ave_shf = (g1 + g2 + g3)/3
    e = -(q + ave_shf)/(1 + bowen)
    h = -(q + e + ave_shf)

Note:  D020717.6 reports Soil temperature sensor #3 was also bad during this
time, but for the very specific records affected by the soil moisture #4 and
#5 reporting incorrectly, soil temp #3 was okay.  Therefore the equations
given are correct.
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_5
  • corr_soil_heat_flow_4
  • soil_heat_capacity_4
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • surface_soil_heat_flux_4
  • soil_moisture_5
  • soil_moisture_4
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D020717.9
Start DateStart TimeEnd DateEnd Time
01/30/2002143001/30/20021431
Subject:
SGP/EBBR/E12 - Reprocess: Soil Moisture 2 and 5 Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil moisture measurements from sets 2 and 5 were incorrect, leading to many other 
incorrect measurements calculated using them.

Average soil heat flow, sensible heat flux, and latent heat flux are affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:
    ave_shf = (g1 + g3 + g4)/3
    e = -(q + ave_shf)/(1 + bowen)
    h = -(q + e + ave_shf)

Note:  D020717.6 reports Soil temperature sensor #3 was also bad during this
time, but for the very specific records affected by the soil moisture #2 and
#5 reporting incorrectly, soil temp #3 was okay.  Therefore the equations
given are correct.
Measurements:sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • corr_soil_heat_flow_2
  • soil_heat_capacity_5
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_5
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • surface_soil_heat_flux_2
  • soil_moisture_2


Back To Table of Contents

DQRID : D021113.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE2.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_4

sgp30ebbrE26.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE22.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE18.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE4.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE15.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE19.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1

sgp30ebbrE8.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1


Back To Table of Contents

DQRID : D021113.4
Start DateStart TimeEnd DateEnd Time
12/01/1993120006/18/20031159
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.
   
This does not affect the data quality.

(NOTE: The actual begin date of some of these data streams
 is as early as 7/4/93.  This DQR applies to all 30m EBBR
 data.)
Measurements:sgp30ebbrE26.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE4.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE15.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE22.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE8.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1


Back To Table of Contents

DQRID : D030110.33
Start DateStart TimeEnd DateEnd Time
08/20/2002160008/20/20021630
11/25/2002181511/25/20021845
Subject:
SGP/EBBR/E12 - Data Incorrect during 6 month checks
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp15ebbrE12.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE12.b1:
  • temp_air_top
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_air_top
  • temp_trh_top
  • rh_bottom_fraction
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D030114.11
Start DateStart TimeEnd DateEnd Time
07/08/2002000007/09/20021330
Subject:
SGP/EBBR/E12 - Resistance-based Measurements Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
When the Reference Temperature in the EBBR 
enclosure is not reported correctly, it
affects all resistance-based measurements
that are adjusted with the temperature of 
the reference junction.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_air_left
  • temp_reference_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • vapor_pressure_bottom
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • corr_soil_heat_flow_1
  • bowen_ratio
  • soil_temp_5
  • corr_soil_heat_flow_2
  • soil_temp_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • soil_temp_3
  • soil_temp_2
  • corr_soil_heat_flow_5
  • soil_temp_1
  • soil_moisture_1
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_moisture_5
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_moisture_4
  • soil_moisture_3
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_moisture_2
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • energy_storage_change_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_reference
  • vapor_pressure_top


Back To Table of Contents

DQRID : D030114.12
Start DateStart TimeEnd DateEnd Time
07/01/2002000007/12/20021800
Subject:
SGP/EBBR/E12 - Wind Direction Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind direction and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D030114.13
Start DateStart TimeEnd DateEnd Time
07/23/2002170007/23/20021729
08/16/2002160008/16/20021629
09/03/2002170009/03/20021729
Subject:
SGP/EBBR/E12 - Data zero following Logger Restart
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Most of the measurements were zero, which normally happens after a 
datalogger restart.  The restart on 08/16/02 occurred after an EBBR
unit changeout.
Measurements:sgp30ebbrE12.b1:
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_heat_flow_3
  • home_signal_30
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_heat_flow_2_mv
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • soil_moisture_3_rr
  • temp_trh_right_rr
  • soil_moisture_1_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • rh_left_mv
  • soil_moisture_2_rr
  • temp_air_left
  • soil_temp_1_rr
  • soil_temp_5_rr
  • net_radiation_mv
  • soil_heat_flow_3_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D030114.14
Start DateStart TimeEnd DateEnd Time
09/09/2002000010/29/20021830
Subject:
SGP/EBBR/E12 - Battery Voltage Low
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Normally, when Battery Voltage drops below 10.5 volts, most 
measurements are suspect and some are often incorrect.
In this particular case, some of the data is suspect when
the battery voltage is below 11.0 volts.

Soil Heat Flow #3 is normally affected first, with other 
measurements following at lower voltages.
Measurements:sgp15ebbrE12.b1:
  • temp_air_left
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right

sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • Radiation, net(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • home_signal_30
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • home_signal_15
  • bowen_ratio
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • soil_temp_5
  • corr_soil_heat_flow_3
  • soil_temp_4
  • corr_soil_heat_flow_4
  • soil_temp_3
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • corr_soil_heat_flow_5
  • soil_temp_2
  • soil_moisture_1
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_moisture_5
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • home_signal
  • wdir_vec_std
  • Barometric Pressure(atmos_pressure)
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • temp_reference
  • vapor_pressure_top
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • rh_top_fraction
  • temp_air_bottom
  • Radiation, net(net_radiation)
  • temp_trh_bottom


Back To Table of Contents

DQRID : D030114.19
Start DateStart TimeEnd DateEnd Time
10/31/2002070011/12/20021730
11/25/2002183011/25/20021900
Subject:
SGP/EBBR/E12 - AEM Stuck in One Position
DataStreams:sgp30ebbrE12.b1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
at a home position, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D030115.2
Start DateStart TimeEnd DateEnd Time
08/16/2002172012/10/20021720
Subject:
SGP/EBBR/E12 - REPROCESS: Net Rad Calibration Coefficients
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The Net Radiometer coefficients were incorrect in the CR10
program when the replacement EBBR unit was installed on
08/16/02.

The data can be easily corrected; see the Suggestion area below.
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D030115.3
Start DateStart TimeEnd DateEnd Time
12/10/2002170012/10/20021729
Subject:
SGP/EBBR/E12 - Data Mostly Zero Following Logger Restart
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Most of the measurements were zero, which normally happens after a 
datalogger restart.

The restart on 12/10/02 occurred after a CR10
program change of net radiometer coefficients 
and subsequent restart of the CR10.
Measurements:sgp30ebbrE12.b1:
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • home_signal_30
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_heat_flow_2_mv
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • soil_moisture_3_rr
  • temp_trh_right_rr
  • soil_moisture_1_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • rh_left_mv
  • soil_moisture_2_rr
  • temp_air_left
  • soil_temp_1_rr
  • soil_temp_5_rr
  • net_radiation_mv
  • soil_heat_flow_3_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D030711.21
Start DateStart TimeEnd DateEnd Time
01/01/2003000001/10/20031630
02/06/2003173002/18/20031715
02/23/2003153003/04/20031645
04/15/2003164504/15/20031700
Subject:
SGP/EBBR/E12 - AEM Hung Inbetween Home Positions
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The AEM was hung inbetween home positions, causing many measurements to be incorrect.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D030712.16
Start DateStart TimeEnd DateEnd Time
04/15/2003163004/15/20031700
Subject:
SGP/EBBR/E12 -  6 Month Checks
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D031031.4
Start DateStart TimeEnd DateEnd Time
10/14/2003013010/14/20031800
Subject:
SGP/EBBR/E12  - Water in Net Radiometer, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D031124.12
Start DateStart TimeEnd DateEnd Time
10/13/2003000011/26/20032300
Subject:
SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltage
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The barometer output was scaling with supply voltage (i.e. it 
               followed the charging of the battery by the solar panel).

               NOTE: The barometer was replaced later than the end date of 
               this DQR.  Why the problem ended on 26 Nov 2003 is unclear; 
               there was no site ops intervention on that date.

               The problem did not affect the sensible and latent heat flux 
               calculations beyond the expected system error.
Measurements:sgp15ebbrE12.b1:
  • atmos_pressure_mv

sgp30ebbrE12.b1:
  • Barometric Pressure(atmos_pressure)

sgp5ebbrE12.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031204.9
Start DateStart TimeEnd DateEnd Time
10/28/2003175010/28/20031845
Subject:
SGP/EBBR/E12 - 6 Month Checks
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D031217.4
Start DateStart TimeEnd DateEnd Time
01/03/2003150010/12/20032355
Subject:
SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltage
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
The barometer output scaled with supply voltage (it followed the charging of the battery 
by the solar panel).

The problem did not affect the sensible and latent heat flux calculations
beyond the expected system error.
Measurements:sgp15ebbrE12.b1:
  • atmos_pressure_mv

sgp30ebbrE12.b1:
  • Barometric Pressure(atmos_pressure)

sgp5ebbrE12.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031222.15
Start DateStart TimeEnd DateEnd Time
12/09/2003223512/10/20031705
Subject:
SGP/EBBR/E12  - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040304.10
Start DateStart TimeEnd DateEnd Time
02/02/2004094502/02/20041820
02/09/2004121502/09/20041430
Subject:
SGP/EBBR/E12  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D040304.11
Start DateStart TimeEnd DateEnd Time
02/02/2004081002/02/20041930
02/09/2004123502/09/20041405
Subject:
SGP/EBBR/E12  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D040615.3
Start DateStart TimeEnd DateEnd Time
02/19/2004221203/10/20042247
Subject:
SGP/EBBR/E12 - Incorrect Times
DataStreams:sgp15ebbrE12.b1, sgp30baebbrE12.c1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgpebbrE12.00
Description:
The ntpd server (time adjustment) stopped working on Feb. 19th at 22:12:16 GMT, and the 
clock was corrected by -5600.177269 seconds on March 10th at 22:47 GMT. The recorded times 
for observations are off by amounts ranging from 0 seconds on Feb. 19th to 5600 seconds 
on March 10th.
Measurements:sgp30ebbrE12.b1:
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_heat_flow_3
  • home_signal_30
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_flow_1
  • energy_storage_change_1
  • soil_heat_flow_2
  • energy_storage_change_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • soil_moisture_5
  • Barometric Pressure(atmos_pressure)
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_heat_flow_2_mv
  • soil_moisture_5_rr
  • soil_heat_flow_5_mv
  • soil_moisture_4_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • soil_moisture_3_rr
  • temp_trh_right_rr
  • soil_moisture_1_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • base_time
  • rh_left_mv
  • soil_moisture_2_rr
  • temp_air_left
  • soil_temp_1_rr
  • soil_temp_5_rr
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • time_offset

sgp30baebbrE12.c1:
  • ts5
  • ts4
  • ts3
  • ts2
  • ts1
  • vp_bot
  • hum_top
  • c_shf2
  • c_shf3
  • Heat flux, sensible, aerodynamic(ah)
  • c_shf1
  • ces5
  • ces4
  • ces3
  • ces2
  • ces1
  • tref
  • vp_top
  • time_offset
  • home_30
  • bowen
  • thum_bot
  • thum_top
  • hum_bot
  • res_ws
  • sigma_wd
  • Corrected sensible heat flux(h)
  • Heat flux, latent(e)
  • c_shf5
  • c_shf4
  • base_time
  • Heat flux, latent, aerodynamic(ale)
  • Average soil heat flux(ave_shf)
  • Radiation, net(q)
  • Heat flux, sensible, best estimate(hcomb)
  • tair_bot
  • g1
  • g4
  • g5
  • g2
  • g3
  • shf1
  • shf2
  • shf3
  • shf4
  • shf5
  • cs2
  • cs1
  • cs4
  • cs3
  • cs5
  • sm1
  • sm2
  • wind_d
  • tair_top
  • home_15
  • vegetation_height
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)
  • sm5
  • sm3
  • sm4
  • wind_s
  • austar
  • Heat flux, latent, best estimate(ecomb)

sgpebbrE12.00:
  • Raw data stream - documentation not supported

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • base_time
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • time_offset
  • time
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D041222.11
Start DateStart TimeEnd DateEnd Time
10/12/2004163010/12/20041700
Subject:
SGP/EBBR/E12 - 6 Month Checks
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D041222.2
Start DateStart TimeEnd DateEnd Time
10/12/2004154510/27/20040645
Subject:
SGP/EBBR/E12 - AEM home_15 Incorrect, Flux Measurements not affected
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The home_15 measurement was incorrect during much of the stated period.
The AEM was exchanging however, and thus the flux measurements were not affected.
Measurements:sgp15ebbrE12.b1:
  • home_signal

sgp30ebbrE12.b1:
  • home_signal_15

sgp5ebbrE12.b1:
  • home_signal


Back To Table of Contents

DQRID : D050206.9
Start DateStart TimeEnd DateEnd Time
01/05/2005073501/08/20051700
Subject:
SGP/EBBR/E12  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050207.5
Start DateStart TimeEnd DateEnd Time
01/05/2005093501/08/20051630
Subject:
SGP/EBBR/E12  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D050215.16
Start DateStart TimeEnd DateEnd Time
01/11/2005104001/11/20050755
Subject:
SGP/EBBR/E12  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D050215.17
Start DateStart TimeEnd DateEnd Time
01/11/2005104001/12/20050410
Subject:
SGP/EBBR/E12  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D050304.1
Start DateStart TimeEnd DateEnd Time
02/25/2005043002/25/20051130
Subject:
SGP/EBBR/E12 - Wind Speed and Direction Frozen by Ice Storm
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind speed and direction sensors were frozen by ice from and ice storm.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D050719.9
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/29/20051830
Subject:
SGP/EBBR/E12 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE12.b1
Description:
Effective 20050329.1830, the EBBR.E12 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050329, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE12.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE12.a1).
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D051106.23
Start DateStart TimeEnd DateEnd Time
03/01/2005180003/29/20051830
Subject:
SGP/EBBR/E12 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D051111.10
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E12 - metadata corrections
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E12 data collected by ARM back to the installation of the 
instrument in August 1993. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.  

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil type
4) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp15ebbrE12.b1:
  • base_time

sgp30ebbrE12.b1:
  • base_time

sgp5ebbrE12.b1:
  • base_time


Back To Table of Contents

DQRID : D060111.5
Start DateStart TimeEnd DateEnd Time
12/27/2005173001/02/20062330
Subject:
SGP/EBBR/E12 - Sensible and Latent Heat Fluxes Incorrect at Times
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1
Description:
Large spikes in soil temperature #2 are causing the soil heat storage
term to blow up, and thus the average soil heat flow, sensible heat flux, 
and latent heat flux to be incorrect at times.
Measurements:sgp15ebbrE12.b1:
  • soil_temp_2_rr

sgp30ebbrE12.b1:
  • energy_storage_change_2
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D060111.8
Start DateStart TimeEnd DateEnd Time
12/08/2005110012/08/20051300
Subject:
SGP/EBBR/E12 - Multiplexer failure
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Sensible and latent heat fluxes are incorrect during a period when multiplexer #2 
experienced a failure.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_air_left

sgp30ebbrE12.b1:
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • vapor_pressure_bottom
  • Radiation, net(net_radiation)
  • soil_moisture_1
  • vapor_pressure_top
  • surface_soil_heat_flux_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_heat_flow_3
  • Barometric Pressure(atmos_pressure)
  • surface_soil_heat_flux_4
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • soil_moisture_4
  • surface_soil_heat_flux_2
  • soil_moisture_3
  • surface_soil_heat_flux_3
  • soil_moisture_2
  • soil_heat_flow_1
  • soil_heat_flow_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • Radiation, net(net_radiation)
  • vapor_pressure_top


Back To Table of Contents

DQRID : D060501.11
Start DateStart TimeEnd DateEnd Time
04/15/2006230004/25/20061700
Subject:
SGP/EBBR/E12 - Fluxes and Gradient Measurements Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The AEM hung in one position; therefore the fluxes and gradient measurements were 
incorrect.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D060921.3
Start DateStart TimeEnd DateEnd Time
08/21/2006120008/29/20061630
Subject:
SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Rain entered into the net radiometer through a broken top dome.  Most of the net radiation 
values during the period are much too large, thus sensible and latent fluxes are also 
too large.
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D060921.4
Start DateStart TimeEnd DateEnd Time
09/01/2006013009/12/20061630
Subject:
SGP/EBBR/E12 - Soil Temperature #1 Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1
Description:
During much of this period soil temperature #1 was offscale or erratic.
Sensible and latent heat fluxes were not ususally affected.
Measurements:sgp15ebbrE12.b1:
  • soil_temp_1_rr

sgp30ebbrE12.b1:
  • soil_heat_capacity_1
  • energy_storage_change_1
  • soil_temp_1
  • surface_soil_heat_flux_1


Back To Table of Contents

DQRID : D061220.6
Start DateStart TimeEnd DateEnd Time
11/23/1993150010/12/20032330
Subject:
SGP/EBBR/E12 - Wind Direction Dependency of Surface Fluxes and General Data Quality 
Information
DataStreams:sgp30ebbrE12.b1
Description:
Beginning in FY2006, Data Quality Reports are not written for missing 
data or for situations when qc flags clearly show that the data is 
incorrect (this is true for most of the conditions listed below).  
DQRs are written for periods when data is incorrect, when the situation 
is not represented by qc flags in the data, and it's not obvious that 
the data should have been flagged as incorrect.

The EBBR data is only useful for particular wind directions at each 
Extended Facility.  Please use the following resources to help in 
interpreting the EBBR data.

1) qc flags in the EBBR data.

2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/

3) SGP EF Surface Conditions Observations (EFSCO) at 
http://198.124.96.210:591/sfc_cond1/default.htm

4) Surface fluxes are valid only for the following wind directions
(in degrees):

0-360

Note that there are wind directions at most sites for which the fetch
is insufficient and therefore EBBR data is invalid.  Appropriate 
fetch was determined from a 1/40 measurement height to fetch ratio, 
resulting in a required minimum fetch of 120 m.  Particular attention 
should be paid to the limited valid wind directions for the Central 
Facility EBBR.	The surface vegetation type for the EBBRs is grazed 
or ungrazed grassland (refer to the EFSCO for state).

5) Some conditions that commonly cause the EBBR primary measurements to 
be incorrect or missing follow:

a) Sensible and latent heat fluxes are not accurate during times when 
the Automatic Exchange Mechanism (AEM) is not functioning properly.  
The AEM switches the gradient measuring instrumentation between the 
top and bottom positions every 15 minutes; this reduces the effects of 
instrument offsets.  Sometimes the AEM does not reach it's full extent 
of travel, resulting in the home signal being zero.  

b) Sensible and latent heat fluxes are sometimes incorrect when surface 
soil heat flow is out of range, as seen in the average soil heat flux 
(ave_shf).

c) Very light winds may be seen at nights for brief periods. Wind 
direction flops around a lot during low wind conditions (< 1.5 m/s) 
and is often unreliable during those periods.

d) Missing data periods occur at times; this is usually a site data 
system collection/communication problem; it can also occur during 
replacement of the system with a newly calibrated unit.  Missing data 
is sometimes filled in later from manual or automatic re-collection of 
the data.
Measurements:sgp30ebbrE12.b1:
  • vapor_pressure_bottom
  • lat
  • lon
  • Radiation, net(net_radiation)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • soil_heat_flow_5
  • vapor_pressure_top
  • surface_soil_heat_flux_1
  • soil_heat_flow_4
  • soil_heat_flow_3
  • home_signal_30
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_flow_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • alt
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • temp_reference
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • home_signal_15
  • bowen_ratio
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • soil_temp_5
  • corr_soil_heat_flow_3
  • soil_temp_4
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • corr_soil_heat_flow_4
  • soil_temp_3
  • soil_temp_2
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • base_time
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • wdir_vec_std
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D090313.12
Start DateStart TimeEnd DateEnd Time
01/27/2009024501/28/20092005
Subject:
SGP/EBBR/E12 - Wind Speed Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind speed sensor was stopped by freezing rain.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D100223.1
Start DateStart TimeEnd DateEnd Time
02/21/2010230002/22/20101730
Subject:
SGP/EBBR/E12 - Wind Speed Sensor Frozen Stopped by Icing
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Icing stopped the wind speed sensor cups and resulted in the measurement of wind speed 
being equivalent to the sensor offset.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D100720.2
Start DateStart TimeEnd DateEnd Time
05/03/2010000006/08/20101800
Subject:
SGP/EBBR/E12 - Intermittent data loss
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The datalogger at E12 EBBR reset it's time to Dec 3, 1999 on a periodic basis.  This 
occurred on 5/3, 5/15, 5/17, 5/18, 5/27, 6/5 and 6/6 of 2010. Each time this occurred we lost 
1-2 hours of data.

The datalogger was apparently at fault.  The problem has not re-occurred since the 
datalogger was replaced on 6/8/2010.
Measurements:sgp30ebbrE12.b1:
  • lat
  • lon
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • alt
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • time
  • soil_heat_flow_5
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • home_signal_30
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • base_time
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • lat
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_heat_flow_2_mv
  • soil_moisture_5_rr
  • soil_heat_flow_5_mv
  • soil_moisture_4_rr
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • soil_moisture_3_rr
  • temp_trh_right_rr
  • soil_moisture_1_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • temp_trh_left_rr
  • soil_heat_flow_1_mv
  • base_time
  • time
  • rh_left_mv
  • soil_moisture_2_rr
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • alt
  • soil_moisture_5_r
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • lon
  • time_offset

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • base_time
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • lat
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • lon
  • alt
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • time_offset
  • time
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D100720.3
Start DateStart TimeEnd DateEnd Time
06/10/2010120006/23/20101630
Subject:
SGP/EBBR/E12 - Sensible and Latent Heat Fluxes and Other Measurements Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The power supply leads for the combined temperature probe shorted somehow, resulting in 
several measurements from the probe and for the multiplexer that it was connected to, to be 
incorrect.
Measurements:sgp30ebbrE12.b1:
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_1
  • energy_storage_change_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • temp_air_top
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • temp_trh_top
  • energy_storage_change_5
  • temp_reference
  • energy_storage_change_3
  • energy_storage_change_4
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • soil_temp_5
  • corr_soil_heat_flow_3
  • soil_temp_4
  • corr_soil_heat_flow_4
  • soil_temp_3
  • corr_soil_heat_flow_5
  • soil_temp_2
  • soil_moisture_1
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • soil_temp_2_rr
  • soil_temp_4_rr
  • temp_trh_left_rr
  • soil_temp_3_rr
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_moisture_5_r
  • temp_air_right
  • temp_trh_right_rr

sgp5ebbrE12.b1:
  • temp_trh_top
  • temp_air_top
  • temp_reference
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D101004.1
Start DateStart TimeEnd DateEnd Time
09/01/2010120009/29/20101600
Subject:
SGP/EBBR/E12 - Net radiation too high
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Net radiation was too high, resulting in overestimated sensible and latent heat fluxes. 

Net rad domes replaced.
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D110830.1
Start DateStart TimeEnd DateEnd Time
06/29/2011153008/03/20111500
Subject:
SGP/EBBR/E12 - Loose connection (SHF #4)
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1
Description:
Soil Heat Flow #4 was sometimes offscale due to a bad connection.  Sensible and latent 
heat fluxes also affected at times.
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_heat_flow_4
  • surface_soil_heat_flux_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • soil_heat_flow_4_mv


Back To Table of Contents

DQRID : D120307.1
Start DateStart TimeEnd DateEnd Time
01/19/2012170002/12/20121630
Subject:
SGP/EBBR/E12 - Soil heat flux #4 intermittently incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Soil heat flux #4 measurements were sometimes incorrect and sometimes affected the 
sensible and latent heat flux calculations.
Measurements:sgp30ebbrE12.b1:
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • corr_soil_heat_flow_4
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • soil_heat_flow_4
  • surface_soil_heat_flux_4
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D120507.5
Start DateStart TimeEnd DateEnd Time
03/05/2012000004/25/20121630
Subject:
SGP/EBBR/E12 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
The air and T/RH measurements were flaky at times.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D940106.2
Start DateStart TimeEnd DateEnd Time
12/20/1993073012/22/19931500
Subject:
SGP/EBBR/E12 - Invalid data due to blown AEM fuse at E12
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
On December 20, 1993, before 0730 GMT, the fuse in the AEM (Automatic
Exchange Mechanism) of Pawhuska, OK (E12) EBBR blew out.  The AEM remained
nonfunctional until the fuse was replaced just before 1500 GMT on
December 22, 1993.  This situation resulted in the following invalid data:

5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
          vp_top, vp_bot, home

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, mv_home, tair_r,
           tair_l

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h, home_15, home_30

Bowen, h, and e can not be recalculated from the 15 minute and/or 5 minute data
since we cannot determine the position of the sensors on the AEM from the home
signal; home signal is near zero when there is no power to the AEM.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • home_signal
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • home_signal_15
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • home_signal_30
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • home_signal
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D940616.3
Start DateStart TimeEnd DateEnd Time
06/03/1994120006/08/19941515
Subject:
SGP/EBBR/E12 - Wind Direction
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
For much of the period above, a malfunction in the E12 EBBR wind direction
sensor (insect larvae shorting out the circuit board) caused incorrect
values for 5 minute res_ws, wind_d, and sigma_wd, 15 minute mv_wind_d, and
30 minute res_ws, wind_d, and sigma_wd.  Wind direction normally indicated
north (near 0 or 360 degrees); there were some times during the period when
wind directions looked good, but the lack of variation in direction and sigma
implies that the data is suspect.  Therefore, it would be wise to flag all
of the values listed above during the entire time period as incorrect.
The wind direction sensor (S/N 3081) was replaced with S/N 3042 at 1515 GMT
on June 8, 1994.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D940711.3
Start DateStart TimeEnd DateEnd Time
06/18/1994200006/22/19941600
Subject:
SGP/EBBR/E12 - Aspirator Failure
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
On June 18, 1994 the aspirator fan in the EBBR at E12, Pawhuska stopped
working.  This situation was not discovered until a Preventative
Maintenance visit by site operations personnel on June 22, 1994.  I
determined the time of the beginning of the malfunction from close
inspection of the sensible and latent heat flux data.  There is no aspiration
status output for the EBBRs, nor is one presently possible.  Wind speeds during
most of the period listed were sufficient to provide some (although
inadequate) aspiration to the temperature and relative humidity probes, making
it difficult for most users of the data to be able to tell (except in a few
circumstances) that the sensible and latent heat flux values produced were
incorrect.  All of the data fields listed below are incorrect for the period
listed above.  Latent and Sensible heat fluxes cannot be recomputed, as the
measurements that they are based on are what was corrupted.

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D940808.2
Start DateStart TimeEnd DateEnd Time
07/22/1994120008/04/19941600
Subject:
SGP/EBBR/E12 - Stopped Ventilation Fan
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
On August 4, 1994, a site operator discovered the ventilation fan of the
EBBR to be stopped; the fan guard was clogged with animal remains.
Inspection of the EBBR data from Pawhuska, OK, E12 indicates that this
condition occurred from July 22 through August 4.  Lack of ventilation of
the temperature and relative humidity sensors attached to the AEM results
in questionable measurements of air temperature, relative humidity, and all
quantities calculated from them, including sensible and latent heat fluxes.
The quantities that are questionable for the period indicated are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, and vp_bot

15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l

30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D940909.1
Start DateStart TimeEnd DateEnd Time
08/20/1994023008/31/19941542
Subject:
SGP/EBBR/E12 - Miscellaneous Problems Affecting Data
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Three hardware problems occurred at E12, Pawhuska, OK in late August 1994.

On August 12 the wind direction sensor malfunctioned.  Therefore, all wind
direction, sigma, and resultant wind speed values for the period above are
incorrect.  The wind direction sensor was replaced on August 31.  Affected
data are:

        5 minute:  wind_d, sigma_wd, res_ws
        15 minute: mv_wind_d
        30 minute: wind_d, sigma_wd, res_ws.

Water accumulated in the AEM motor box and apparently caused a reduction in
the voltage level of the home signal (battery condition was very good and so
was not the cause); by late August 27 the hom30 level had fallen below the
minimum qc check level.  The AEM continued to exchange properly.  The minimum
qc level check is intended to help detect either a non-operating AEM or low
battery condition.  The Campbell CR10 software operates properly unless the
hom30 signal is thirty-five or greater.  So the low hom30 values do not
result in any incorrect data!!!.  I point this out because this situation
demonstrates a condition flagged by the qc checks, even though no effect on
the data has occurred.  The AEM box was dried out and new dessicant placed
in it on August 31.

On August 28, 1994 the left AEM housing ventilation fan ceased to operate
because of clogging of the ventilation system with debris.  Fifteen minute
data seems to indicate that the fan stopped operating just before 1245 GMT.
This is at least the third such incidence of clogging this summer at different
EBBRs.  The clog was removed and ventilation restored on August 31.  The lack
of ventilation caused improper measurements of temperature and
relative humidity in the left housing (these are quite obvious in the 15
minute data but difficult to detect in the 30 minute data) and therefore
incorrect values of sensible and latent heat.  Affected data are:

        5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top,
                   hum_bot, vp_top, vp_bot
        15 minute: rr_thum_l, mv_hum_l, tair_l
        30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top,
                   hum_bot, vp_top, vp_bot, bowen, e, h.
Measurements:sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • Wind speed vector mean(wspd_vec_mean)
  • rh_top_fraction
  • bowen_ratio
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • home_signal_30
  • rh_bottom_fraction
  • wdir_vec_std
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv
  • home_signal
  • temp_trh_left_rr
  • rh_left_mv
  • temp_air_left

sgp5ebbrE12.b1:
  • rh_top_fraction
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • vapor_pressure_top
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D941021.12
Start DateStart TimeEnd DateEnd Time
09/15/1994160009/29/19941430
Subject:
SGP/EBBR/E12 - Net Radiometer Hemisphere Changes
DataStreams:sgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
Description:
The upper hemisphere of the net radiometer at the site was punctured
allowing water to collect in the lower (and sometimes upper) section of the sensor. The 
punctures are most likely the result of migratory birds (a problem that we have experienced 
almost every year here at ANL also). The punctures (and water in some net radiometers) 
did not result in obvious invalidation of the data.

Whether there is water in the lower hemisphere or not, a small puncture of the upper 
hemisphere would not have a major effect on the net radiation measurement.  Significant 
amounts of water in the lower
hemisphere should have a major effect on nighttime measurements particularly, although 
that effect is hard to detect in the data. 
The date when the puncture occurred is approximate - but is certainly 
no more than two weeks before the hemisphere was replaced.
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D941021.6
Start DateStart TimeEnd DateEnd Time
09/03/1994190009/15/19941330
Subject:
SGP/EBBR/E12 - Low home_15 Values
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The home signal values for the EBBR system installed at E12, Pawhuska, OK have
generally been lower than for the other EBBR systems.  However, during the
period above the home_15 value was often lower than 35, which is then
improperly interpreted by the CR10 software.  A home_15 value less than 35 is
interpreted as meaning that the AEM aspirated housings (which hold the
temperature and relative humidity sensors) are in the opposite orientation to
what they actually are.  The AEM continues to exchange properly, but the
resulting calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect.  On September 15, 1994 Site Operations personnel
refurbished the wiring for the left housing and the home_15 signal returned
to proper levels.

When 30 minute home_15 values are below 35, the data fields listed below are
incorrect.

5 minute:  home, tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot

15 minute: mv_home

30 minute: home_15, tair_top, tair_bot, thum_top, thum_bot, hum_top,
           hum_bot, vp_top, vp_bot, Bowen, e, h

It is possible to recalculate the Bowen ratio, e, and h by using the 15
minute data to compute the correct gradients of temperature and relative
humidity (two 15 minute periods are averaged to give a half hour value); the
orientation of the AEM is obvious in the 15 minute data, based on the home
signal (which is largest for the first 15 minutes of the half hour).  More
information on performing this recalculation can be obtained from the
mentor.
Measurements:sgp15ebbrE12.b1:
  • home_signal

sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • home_signal
  • rh_top_fraction
  • temp_air_top
  • temp_trh_top
  • rh_bottom_fraction
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D950626.15
Start DateStart TimeEnd DateEnd Time
04/23/1995002004/26/19951630
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
For most of the period above, a malfunction in the E12 EBBR wind direction
sensor caused the following data values to be incorrect:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.

Wind direction normally indicated near north or 135 degrees (the latter
indicates a malfunction).

The wind direction sensor (S/N 3036) was replaced with S/N 3034 at 1620 GMT
on April 26, 1995.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D950626.16
Start DateStart TimeEnd DateEnd Time
06/06/1995070006/07/19951830
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
For the period indicated, a malfunction in the E12 EBBR wind direction
sensor caused the following data values to be incorrect:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.

Wind direction normally indicated smaller or larger than it should have.
The affected time period was determined from comparison with data from E7,
Elk Falls EBBR, which is located north of E12.

The wind direction sensor (S/N 3034) was replaced with S/N 3039 at 1822 GMT
on June 7, 1995.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D950719.2
Start DateStart TimeEnd DateEnd Time
07/03/1995060007/07/19951605
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
For the period indicated, a malfunction in the E12 EBBR wind direction
sensor caused the following data values to be incorrect:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.

Wind direction normally indicated small values (15 to 25 degrees) from 3 July
1995 at 0600 GMT through 6 July 1995 at 1500 GMT (at which time the sensor
was removed).  No sensor was in place between 6 July 1995 at 1500 GMT and 7
July 1995 at 1605 GMT (at which time a new sensor was installed).
 Old sensor S/N K3039, new S/N K3033.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D950816.2
Start DateStart TimeEnd DateEnd Time
07/20/1995170009/14/19952359
Subject:
SGP/EBBR/E12 - AEM Failure
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
As noted in a previous DQR, the home signal values at E12, Pawhuska, OK
began decreasing in July.  At the beginning of the period listed, the home
30 value dropped below 15; this causes a data quality message to be output in
the site operations log as the stated acceptable range for home 30 is 15 to
34.999999.  No data is incorrect as a result of this condition.

The home 15 value dropped below 35 beginning July 21, 1995, sometime after
2000 GMT; this causes a data quality message to be output in the site
operations log as the stated acceptable range for home 15 is 35 to
70.  Data is incorrect as a result of this condition, that being 30 minute e,
h, and bowen.

The home values frequently dropped below their proper levels until 10 August,
1995, at some time after 1100 GMT, when the set screws in the AEM would no
longer hold and the aspirator units were stranded inbetween the home
positions.  Thereafter, the reported home signals were negative.  All 30
minute e, h, and bowen data are incorrect for this condition.

On August 16, 1995, at about 1600 GMT, site operators determined that they
could not repair the AEM on-site and they determined that the replacement AEM
that they took with them has an electronic short.  Therefore, the AEM was
left in manual mode (no exchange).  Replacement of the AEM will not take
place until a working spare is available and all 30 minute e, h, and bowen
data will be incorrect until then.

I will submit another DQR or addendum when successful replacement of the
AEM is accomplished.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_30
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • home_signal


Back To Table of Contents

DQRID : D950908.3
Start DateStart TimeEnd DateEnd Time
08/16/1995001508/30/19951757
Subject:
SGP/EBBR/E12 - Wind Direction Malfunction
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
For the period above, a malfunction in the E12 EBBR wind direction
sensor caused the wind direction to output a constant 212 degrees.  Site
operations replaced the sensor (S/N K3033) with K3042.  The following data
values are incorrect for the period listed:

5 minute: res_ws, wind_d, and sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, and sigma_wd.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D950921.3
Start DateStart TimeEnd DateEnd Time
07/20/1995170009/14/19951830
Subject:
SGP/EBBR/E12 - AEM replacement
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
Please see DQR P950816.2, where this problem was first documented.

As noted in a previous DQR, the home signal values at E12, Pawhuska, OK
began decreasing in July.  At the beginning of the period listed, the home
30 value dropped below 15; this causes a data quality message to be output in
the site operations log as the stated acceptable range for home 30 is 15 to
34.999999.  No data is incorrect as a result of this condition.

The home 15 value dropped below 35 beginning July 21, 1995, sometime after
2000 GMT; this causes a data quality message to be output in the site
operations log as the stated acceptable range for home 15 is 35 to
70.  Data is incorrect as a result of this condition, that being 30 minute e,
h, and bowen.

The home values frequently dropped below their proper levels until 10 August,
1995, at some time after 1100 GMT, when the set screws in the AEM would no
longer hold and the aspirator units were stranded inbetween the home
positions.  Thereafter, the reported home signals were negative.  All 30
minute e, h, and bowen data are incorrect for this condition.

On August 16, 1995, at about 1600 GMT, site operators determined that they
could not repair the AEM on-site and they determined that the replacement AEM
that they took with them has an electronic short.  Therefore, the AEM was
left in manual mode (no exchange).  All 30 minute e, h, and bowen data are
incorrect until the end of the period listed above.

On 13 September 1995 site operations personnel replaced the AEM
(old S/N 92005, new S/N 94008).  The new AEM would not exchange when the
right sensor was in the home position: this was confirmed on 14 September
when site operations personnel again visited the site.  However, soon after
the site operations personnel left Pawhuska on 14 September (at 1810 GMT),
the AEM started to exchange properly (data correct for 1900 GMT and after).
The AEM continues to operate properly.
Measurements:sgp30ebbrE12.b1:
  • home_signal_15
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_30
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • home_signal


Back To Table of Contents

DQRID : D951127.3
Start DateStart TimeEnd DateEnd Time
11/18/1995031511/21/19952130
Subject:
SGP/EBBR/E12 - AEM Failure/Right Radiation Shield OFF
DataStreams:sgp30ebbrE12.b1
Description:
On 18 November 1995 the AEM at E12, Pawhuska, OK stopped exchanging, with
the right radiation shield at the bottom position.  The 30 minute home
signal reflects this condition.  During the 21 November PM visit, the site
operators also found that the right radiation shield was no longer attached
to the AEM, but was dangling by its conduit.  It is not clear whether both
conditions occurred simultaneously.  Comparison of E12 data with that at
the Central Facility indicates that E12 data was correct on 17 November.

The AEM had stopped exchanging because a transistor became unsoldered from
the AEM circuit board.  Site operators repaired this and reattached the
right radiation shield to bring the system to operational status at 2130
GMT.

All 30 minute latent heat (e), sensible heat (h), and Bowen ratio (bowen)
data during the period above are incorrect.
Measurements:sgp30ebbrE12.b1:
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)


Back To Table of Contents

DQRID : D960320.3
Start DateStart TimeEnd DateEnd Time
01/23/1996073001/24/19961615
01/18/1996050001/18/19962100
Subject:
SGP/EBBR/E12 - Wind Speed Cups Frozen
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
Freezing rain, snow, and below freezing conditions during 18 and 23 January 
1996 caused the wind speed sensor cups to freeze in a stopped state at E12, 
Pawhuska, OK.  The cups were freed up later on 18 January when the wind speed 
rose to above 10 meters per second.  When temperatures rose to above freezing 
on 24 January 1996, the ice thawed and the cups turned freely again. 

Measurements affected by the stalled wind speed sensor include:

5 minute:  wind_s, res_ws

15 minute: wind_s

30 minute: wind_s, res_ws
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D960508.5
Start DateStart TimeEnd DateEnd Time
04/11/1996155004/11/19961640
Subject:
SGP/EBBR/E12 - 3-month check
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed above; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D961122.23
Start DateStart TimeEnd DateEnd Time
10/25/1996160010/25/19961640
Subject:
SGP/EBBR/E12 - EBBR 3 Month Checks - 10 EFs
DataStreams:sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D961122.3
Start DateStart TimeEnd DateEnd Time
10/09/1996100010/09/19962000
Subject:
SGP/EBBR/E12 - Annual Calibration Changeout
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
On 9 October 1996 the EBBR changeout for annual calibration occurred at 
E12, Pawhuska, OK.  SEBS unit 10 was removed and unit 1 was installed.  Between 
1000 and 1500 GMT no data was collected.  Data for half hours 1530-2000 GMT is 
incorrect; 3 month calibration checks were being performed.
Measurements:sgp30ebbrE12.b1:
  • lat
  • lon
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • alt
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • base_time
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • lat
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_heat_flow_2_mv
  • soil_heat_flow_5_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • base_time
  • rh_left_mv
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • alt
  • soil_moisture_5_r
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • lon
  • time_offset

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • base_time
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • lat
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • lon
  • alt
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • time_offset
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D961122.8
Start DateStart TimeEnd DateEnd Time
09/24/1996171509/24/19961730
Subject:
SGP/EBBR/E12 - Left Air Temperature Thermocouple Incorrect
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
The left air temperature thermocouple was offscale, for unknown reasons, for 
1715 GMT for 15 minute, and 1730 GMT for 30 minute air temperature values.

The malfunction of the air temperature thermocouple results in incorrect Bowen 
ratio, sensible heat flux, and latent heat flux during the period indicated. 

The data values that are affected are:

5 minute:  tair_top, tair_bot

15 minute: tair_l

30 minute: tair_top, tair_bot, bowen, e, and h
Measurements:sgp15ebbrE12.b1:
  • temp_air_left

sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D961122.9
Start DateStart TimeEnd DateEnd Time
07/13/1996000010/09/19962359
Subject:
SGP/EBBR/E12 - Battery Voltage Low - Fluxes Affected
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The battery condition deteriorated over time so that the solar panel was not 
always able to keep the battery voltage high enough to produce correct home 
signal values.  The home 15 signal was too low much of the period above, 
with home 30 being low also occasionally.  The home signal qc checks should 
be consulted to determine which half hour values of sensible (h) and latent (e)
heat fluxes are incorrect; no other data values were affected.  The first 
occurrence of low home 15 signal appears to be 0630 GMT on 13 July 1996.  
Battery voltage did not drop low enough to cause any sensors to stop 
functioning.  The battery was replaced on 9 October 1996 at 2000 GMT, 
during annual calibration changeout of the entire EBBR unit (the mentor 
assumes that the battery was replaced - no instrument maintenance reports 
are available for that time).
Measurements:sgp15ebbrE12.b1:
  • home_signal

sgp30ebbrE12.b1:
  • home_signal_15
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • home_signal_30
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • home_signal


Back To Table of Contents

DQRID : D970401.1
Start DateStart TimeEnd DateEnd Time
03/20/1997225503/31/19972359
Subject:
Controlled burn at E12 on 3/20/97 and affected data
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgpsirosE12.a1
Description:
DQR No:                               Platforms:  sgpsirosE12
                                                  sgpebbrE12

Subject: Controlled burn at E12 on 3/20/97 and affected data

Date Submitted:  3/31/97
Submitted By: Mike Splitt             ___  Instrument Mentor
                                      ___  EST Member
                                      ___  Science Team Member
                                      _x_  Other _Site_Scientist_Team_
 
For questions or problems, please contact the ARM Experiment Center at
509-375-6898 or via email at problems@arm.gov.

Platform/Measurement:
        What level data: (raw,a0,a1,b1,c1 etc):
             all levels
    What location was the data collected at: sgp E12
 
    Period of time in question
        Begin Date   3/20/97  Time   22:55    (GMT)
        End Date      *       Time     :      (GMT)

* The "end date" is not necessarily in need of definition. The EBBR data
  appears to be directly affected for a period of about one hour. The
  effect on the local shortwave albedo will be longer lasting and could 
  be said to "end" when the vegetative state recovers to being representative
  of similar areas.

 Data should be labeled:
 ___  questionable                      ___  All data fields affected
 ___  incorrect                         ___  Only some data fields affected
 ___  wrong calibration
 _x_  others 
 
 Discussion of Problem:

This report is reflective of a change in environmental conditions thought
to be worth noting at E12, Pawhuska, and does not concern any issue of
substandard sensor performance. 

A contolled burn was conducted at the the Pawhuska Extened Facillity (E12)
by the Tallgrass Prairie Preserve. The Preserve director, Bob Hamilton,
contacted the ARM SGP Site prior to the activity which allowed Site Operations
to take precautionary steps. Danny Nelson reported the following activities by
Site Operations:

1)  Site Ops cut and removed all dried grass within the EF fence and
also to a 10' perimeter around the outside of the fence.  Final grass
height was 1-3".  This was done on Monday the 17th of March.

2)  Tallgrass Prairie Preserve personnel put down a 10' wet line around
our EF prior to the burn on the 20th, so the EF area was not burned.

3)  Site Ops had originally planned to deploy a field crew to inspect
the site on the day following the burn.  TPP director Bob Hamilton had
agreed to call us the morning of the burn, but didn't actually call us
until this morning; the day following the burn.  Due to the short
notification and prior commitment of personnel, Site Ops will not be
able to travel to the site until Monday or Tuesday of next week.

John Shatz was given the following information about the duration of
the burn:

>Bob Hamilton called and indicated that they did a control burn of the
>Tall Grass Prairie yesterday(3-20-97).  He indicated that the fire in
>our area lasted between 4:55 PM to 5:40 PM.  He also said that they
>plan to put this control burning on a two to three year cycle.

Affect on ARM Data:

Review of the EBBR temperature data (the sensor in the lower position)
shows a dramatic increase of temperature from 26 to 37 Celsius in a 
10 minute period.  The temperatures appear to have been affected for 
approximately 1 hour. 

Analysis of the broadband shortwave albedo during this period reveals
changes that appear to be related to the burn. The following is 
a listing of the daily average shortwave albedos (caluclated by running a linear
regression fit on the "curve" created by plotting the upwelling shortwave 
vs. the downwelling shortwave values from the E12 SIROS broadband instrumentation):

    Date        Broadband Shortwave Albedo
    ________   ____________________________

    3-14-97              .171
    3-15-97              .171
    3-16-97              .169
    3-17-97              .166
    3-18-97              .135
    3-19-97              .171
    3-20-97              .174
    3-21-97              .141
    3-22-97              .143
    3-23-97              .148
    3-24-97              .147

The grass cutting activity at the EF does not appear to be responsible
for the abledo change on 3-18; this is likely related to the drizzle
and overcast sky conditions in the area on that day. Note that the albedo
recovers to previous values by the next day. 

The burn occured late on the 20th, and it appears the albedo after the
burn sustained a more long-lasting decrease in value.  Examination of
both the upwelling and downwelling solar irradiance indicates that 
the albedo change was a resultant of the decrease in upwelling irradiance,
as the downwelling values were comparable to other sites.
Measurements:sgp30ebbrE12.b1:
  • lat
  • lon
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • alt
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • base_time
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • lat
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_heat_flow_2_mv
  • soil_heat_flow_5_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • temp_trh_left_rr
  • soil_heat_flow_1_mv
  • base_time
  • rh_left_mv
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • alt
  • soil_moisture_5_r
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • lon
  • time_offset

sgpsirosE12.a1:
  • Radiation, shortwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_short_hemisp)
  • time_offset
  • lon
  • lat
  • Radiation, shortwave, downwelling total hemispheric irradiance, 1-min avg(down_short_hemisp)
  • channel
  • down_long_case_temp
  • Direct Normal Irradiance, NIMFR(direct_norm_narrowband)
  • Radiation, shortwave, downwelling diffuse hemispheric irradiance, 1-min avg(down_short_diffuse_hemisp)
  • flag_zero_cosine1-24
  • down_long_dome_temp
  • Direct Normal Broadband Irradiance(direct_norm_broadband)
  • down_long_diffuse_hemisp
  • Radiation, longwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_long_hemisp)
  • mfrsr_temp
  • logger_temp
  • alt
  • hemisp_broadband
  • flag_zero_divisor1-24
  • therm_volt
  • flag_ln_error1-24
  • diffuse_hemisp_broadband
  • hemisp_narrowband
  • flag_nighttime1-24
  • up_long_dome_temp
  • base_time
  • up_long_case_temp
  • Radiation, shortwave, direct normal irradiance, 1-min avg(short_direct_normal)
  • logger_volt
  • diffuse_hemisp_narrowband

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • base_time
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • lat
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • lon
  • alt
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • time_offset
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D970730.2
Start DateStart TimeEnd DateEnd Time
06/03/1997120006/08/19971515
Subject:
SGP/EBBR/E12 - Wind Direction Sensor Malfunctions
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
For much of the period above, a malfunction in the E12 EBBR wind direction 
sensor (insect larvae shorting out the circuit board) caused incorrect 
values for 5 minute res_ws, wind_d, and sigma_wd, 15 minute mv_wind_d, and 
30 minute res_ws, wind_d, and sigma_wd.  Wind direction normally indicated 
north (near 0 or 360 degrees); there were some times during the period when 
wind directions looked good, but the lack of variation in direction and sigma 
implies that the data is suspect.  Therefore, it would be wise to flag all
of the values listed above during the entire time period as incorrect. 
The wind direction sensor (S/N 3081) was replaced with S/N 3042 at 1515 GMT 
on June 8, 1997.
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D971021.4
Start DateStart TimeEnd DateEnd Time
04/10/1997165204/10/19971758
Subject:
SGP/EBBR/E12 - EBBR Biannual Checks
DataStreams:sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled 
(reflected by home signals near zero) so that the two aspirator units
can be placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), 
or latent heat flux (e), nor do the air temperature and relative humidity 
measurements indicate correct gradients.  Checks performed before or after the 
AEM is disabled also lead to some incorrect data.  Incorrect 5, 15 minute and 
half hour data occurs for periods indicated.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D980117.17
Start DateStart TimeEnd DateEnd Time
01/04/1998075001/04/19981900
01/08/1998070501/08/19981925
Subject:
SGP/EBBR/E12- EBBR Frozen Wind Speed
DataStreams:sgp5ebbrE12.b1, sgp15ebbrE12.b1, sgp30ebbrE12.b1
Description:
Wind speed cups were frozen during the indicated time periods. All 5,
15, and 30 minute data values indicated  are incorrect for the periods
listed.
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D980117.26
Start DateStart TimeEnd DateEnd Time
01/04/1998130001/15/19981715
Subject:
SGP/EBBR/E12 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown)
DataStreams:sgp30ebbrE12.b1, sgp15ebbrE12.b1, sgp5ebbrE12.b1
Description:
The EBBR AEM stopped exchanging because of icing at during this time
period.

The calculations of Bowen ratio, latent heat flux, and sensible heat
flux are incorrect for the time period indicated.  The other
measurements listed  are also incorrect for those times:

Note:  Mentor supplied the end date/time for this DQR after submittal
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D980117.32
Start DateStart TimeEnd DateEnd Time
12/18/1997170012/31/19971615
Subject:
SGP/EBBR/E12 - EBBR Net Radiometer Domes Pierced, Water Inside - Data Affected
DataStreams:sgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
Description:
The upper dome of the EBBR net radiometers was punctured.
After the puncture, water collected in the top and/or bottom dome.  The
water was removed and the dome was replaced during PM visits. 

 In some cases, the puncture and water resulted in incorrect data. 
Comparison with net radiation values from surrounding EBBR sites and the
SIRS is neccesary to determine if the EBBR net radiation data 
are correct or incorrect.

It is often difficult to tell from the data when the punctures occurred,
but they would have existed for no more than 2 weeks, since the domes
are checked during each two-weekly PM visit.

Incorrect net radiation data results in the latent heat flux and
sensible heat flux also being incorrect.
Measurements:sgp30ebbrE12.b1:
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • Radiation, net(net_radiation)

sgp15ebbrE12.b1:
  • net_radiation_mv

sgp5ebbrE12.b1:
  • Radiation, net(net_radiation)


Back To Table of Contents

DQRID : D980117.6
Start DateStart TimeEnd DateEnd Time
11/27/1997053012/18/19971805
Subject:
SGP/EBBR/E12 - AEM Failure and Replacement
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The E12 AEM did not exchange for most of the period above, yielding small
negative home signals.  The AEM was replaced on 18 December by site
operations personnel.  All 30 minute e, h, and bowen data are incorrect for
the times when the home signal is incorrect, and the temperature, relative
humidity, and vapor pressures do not represent properly switched values.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • home_signal
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • home_signal_15
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • home_signal_30
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • home_signal
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D980416.11
Start DateStart TimeEnd DateEnd Time
10/23/1997195510/23/19972015
Subject:
SGP/EBBR/E12 - 3-Month Check
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during these periods 
do not produce correct outputs of bowen ratio (bowen), sensible heat flux
(h), or latent heat flux (e), nor do the air temperature and relative 
humidity measurements indicate correct gradients.  Checks performed before 
or after the AEM is disabled also lead to some incorrect data.  Incorrect 5,
15 minute and half hour data occurs for the period above.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D980528.13
Start DateStart TimeEnd DateEnd Time
04/07/1998013005/21/19981830
Subject:
SGP/EBBR/E12 - Wind Direction Sensor Failure
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind direction sensor failed, producing zero values.  
The cause is unknown.  Data values affected are below:

 5 minute: res_ws, wind_d, sigma_wd

15 minute: mv_wind_d

30 Minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D980529.9
Start DateStart TimeEnd DateEnd Time
05/21/1998185505/21/19981918
Subject:
SGP/EBBR/E12 - Six Month Checks
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
During EBBR 6 month checks (formally called 3 month checks) the Automatic 
Exchange Mechanism is disabled (reflected by home signals near zero) so that
the two aspirator units can be placed at the same height.  The measurements
during these periods do not produce correct outputs of bowen ratio (bowen), 
sensible heat flux (h), or latent heat flux (e), nor do the air temperature
and relative humidity measurements indicate correct gradients.  Checks 
performed just before or after the AEM is disabled also lead to some 
incorrect data.  Incorrect 5, 15 minute and half hour data occurs for the 
period indicated.
Measurements:sgp15ebbrE12.b1:
  • temp_air_right
  • temp_trh_left_rr
  • rh_left_mv
  • rh_right_mv
  • temp_air_left
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • rh_bottom_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_trh_top
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D990127.21
Start DateStart TimeEnd DateEnd Time
12/21/1998024512/22/19981630
Subject:
SGP/EBBR/E12 - Wind Direction Data Incorrect (revised)
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind direction sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  res_ws, wind_d, sigma_wd
15 minute: mv_wind_d
30 minute: res_ws, wind_d, sigma_wd
Measurements:sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • wdir_vec_std

sgp15ebbrE12.b1:
  • wdir_vec_mean_mv

sgp5ebbrE12.b1:
  • wdir_vec_std
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)


Back To Table of Contents

DQRID : D990128.1
Start DateStart TimeEnd DateEnd Time
12/20/1998233512/22/19981630
01/07/1999180501/09/19990330
01/01/1999170001/03/19991130
Subject:
SGP/EBBR/E12 - Wind Speed Data Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp15ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp30ebbrE12.b1:
  • Wind speed vector mean(wspd_vec_mean)
  • Wind speed, lower, 1-min avg(wspd_arith_mean)

sgp5ebbrE12.b1:
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • Wind speed vector mean(wspd_vec_mean)


Back To Table of Contents

DQRID : D990128.2
Start DateStart TimeEnd DateEnd Time
01/07/1999180501/09/19990330
Subject:
SGP/EBBR - EBBR E12 Wind Speed Data Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp5ebbrE12.00
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE12.b1:
  • lat
  • lon
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • alt
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • base_time
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • lat
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_heat_flow_2_mv
  • soil_heat_flow_5_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • base_time
  • rh_left_mv
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • alt
  • soil_moisture_5_r
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • lon
  • time_offset

sgp5ebbrE12.00:
  • Raw data stream - documentation not supported

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • base_time
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • lat
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • lon
  • alt
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • time_offset
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D990129.1
Start DateStart TimeEnd DateEnd Time
01/01/1999170001/03/19991130
Subject:
SGP/EBBR - EBBR E12 Wind Speed Data Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp5ebbrE12.00
Description:
The wind speed sensor was iced stopped by freezing rain, 
resulting in the following values being incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws,
Measurements:sgp30ebbrE12.b1:
  • lat
  • lon
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • rh_bottom_fraction
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • alt
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • energy_storage_change_1
  • soil_heat_flow_1
  • energy_storage_change_2
  • soil_heat_flow_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • soil_moisture_5
  • base_time
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • lat
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_heat_flow_2_mv
  • soil_heat_flow_5_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • base_time
  • rh_left_mv
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • alt
  • soil_moisture_5_r
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • lon
  • time_offset

sgp5ebbrE12.00:
  • Raw data stream - documentation not supported

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • base_time
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • lat
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • lon
  • alt
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • time_offset
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D990129.2
Start DateStart TimeEnd DateEnd Time
12/28/1998160012/28/19981630
Subject:
SGP/EBBR/E12 - Data Incorrect
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp5ebbrE12.00, sgp15ebbrE12.b1
Description:
Most of the data values for just this time (1630 GMT) for the 5, 15, and 30
minute periods are incorrect; this apparently was the result of PM activities.
Measurements:sgp30ebbrE12.b1:
  • lat
  • lon
  • Radiation, net(net_radiation)
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • rh_bottom_fraction
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • alt
  • Average soil heat flow at the surface(surface_soil_heat_flux_avg)
  • temp_trh_bottom
  • Wind speed vector mean(wspd_vec_mean)
  • energy_storage_change_5
  • energy_storage_change_3
  • energy_storage_change_4
  • rh_top_fraction
  • time_offset
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • wdir_vec_std
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_heat_flow_3
  • surface_soil_heat_flux_4
  • home_signal_30
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • soil_heat_flow_1
  • energy_storage_change_1
  • soil_heat_flow_2
  • energy_storage_change_2
  • temp_air_top
  • temp_trh_top
  • temp_reference
  • home_signal_15
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • soil_moisture_1
  • Barometric Pressure(atmos_pressure)
  • soil_moisture_5
  • base_time
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_2
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp15ebbrE12.b1:
  • lat
  • soil_temp_3_rr
  • atmos_pressure_mv
  • temp_reference_rr
  • soil_moisture_2_r
  • soil_moisture_4_r
  • soil_heat_flow_2_mv
  • soil_heat_flow_5_mv
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • temp_air_right
  • soil_heat_flow_4_mv
  • battery_voltage
  • rh_right_mv
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • soil_temp_2_rr
  • soil_temp_4_rr
  • home_signal
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • base_time
  • rh_left_mv
  • soil_moisture_3_r
  • temp_air_left
  • soil_moisture_1_r
  • soil_temp_1_rr
  • soil_temp_5_rr
  • alt
  • soil_moisture_5_r
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • lon
  • time_offset

sgp5ebbrE12.00:
  • Raw data stream - documentation not supported

sgp5ebbrE12.b1:
  • wdir_vec_std
  • temp_trh_top
  • rh_bottom_fraction
  • base_time
  • temp_air_top
  • Wind speed vector mean(wspd_vec_mean)
  • Wind direction, vector, lower, 1-min avg(wdir_vec_mean)
  • lat
  • Radiation, net(net_radiation)
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_bottom
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • lon
  • alt
  • temp_reference
  • vapor_pressure_top
  • rh_top_fraction
  • time_offset
  • temp_air_bottom
  • temp_trh_bottom


Back To Table of Contents

DQRID : D990129.3
Start DateStart TimeEnd DateEnd Time
12/28/1998134512/28/19981730
Subject:
SGP/EBBR/E12 - Temperature, RH, and Vapor Pressure Data Incorrect
DataStreams:sgp15ebbrE12.b1, sgp30ebbrE12.b1, sgp5ebbrE12.b1
Description:
The right aspirator housing fell off of the AEM around 1345 GMT, by looking
at the data.  The housing was put back into place later in the day during 
a PM visit.  The following values were affected:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top,
           vp_bot
15 minute: rr_thum_r, mv_hum_r, tair_r
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top,
           vp_bot, bowen, e, h
Measurements:sgp15ebbrE12.b1:
  • rh_right_mv
  • temp_air_right
  • temp_trh_right_rr

sgp30ebbrE12.b1:
  • bowen_ratio
  • temp_air_top
  • vapor_pressure_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_trh_top
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • rh_top_fraction
  • temp_air_top
  • temp_trh_top
  • rh_bottom_fraction
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D990129.4
Start DateStart TimeEnd DateEnd Time
11/24/1998131511/24/19981530
Subject:
SGP/EBBR/E12 - All Temperature Measurements Incorrect
DataStreams:sgp30ebbrE12.b1, sgp5ebbrE12.b1, sgp15ebbrE12.b1
Description:
Failure of the multiplexer connection for the reference temperature 
thermocouple in the control box or a problem with the Campbell CR10
bridge circuitry caused all air and soil temperature measurements
to be incorrect. Therefore, the computed 30 minute bowen, e, and h were 
also incorrect.
Measurements:sgp15ebbrE12.b1:
  • soil_temp_2_rr
  • soil_temp_4_rr
  • temp_air_right
  • temp_trh_left_rr
  • soil_temp_3_rr
  • temp_air_left
  • temp_trh_right_rr
  • soil_temp_1_rr
  • soil_temp_5_rr
  • temp_reference_rr

sgp30ebbrE12.b1:
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • temp_reference
  • bowen_ratio
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
  • temp_air_bottom
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)

sgp5ebbrE12.b1:
  • temp_trh_top
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_reference


Back To Table of Contents

DQRID : D990622.4
Start DateStart TimeEnd DateEnd Time
06/04/1999163006/04/19991700
Subject:
SGP/EBBR/E12 - RH top Data Zero
DataStreams:sgp30ebbrE12.b1
Description:
The one data value hum_top was incorrect in the 30 minute data.  5 and 15
minute data were not affected, and the 30 minute flux data was not affected.
The data value may have been lost in remote data retrieval, resulting in
a zero value instead.
Measurements:sgp30ebbrE12.b1:
  • rh_top_fraction


Back To Table of Contents



END OF DATA