DQRID : D090213.1
Start DateStart TimeEnd DateEnd Time
05/16/2008000012/28/20082359
Subject:
HFE/SKYRAD/M1 - IRT bias
DataStreams:hfeskyrad60sM1.b1
Description:
The sky temperatures exhibited a positive bias compared to AERI, especially when < 230K. 
This is indicative of an incorrect emissivity setting (to compensate for the gold mirror) 
or a poor calibration. A similar problem with the same instrument occurred during the FKB 
deployment that was attributed to water vapor.
Measurements:hfeskyrad60sM1.b1:
  • sky_ir_temp_min
  • IR Brightness Temperature(sky_ir_temp)
  • sky_ir_temp_max


Back To Table of Contents

DQRID : D100216.5
Start DateStart TimeEnd DateEnd Time
05/08/2008000012/28/20082359
Subject:
HFE/VCEIL/M1 - Reprocess: Incorrect serial_number and sum_backscatter fields
DataStreams:hfevceil25kM1.b1
Description:
Attribute serial_number: In most cases, this field is not representative of the actual 
serial number of the instrument because the value did not change when an instrument changed 
locations or was replaced with a spare.
   
Variable sum_backscatter: An out-of-range condition for the "sum of detected and 
normalized backscatter" was reported as 0 instead of missing (-9999). The valid range is 0 - 
0.0999 /srad.
Measurements:hfevceil25kM1.b1:
  • sum_backscatter


Back To Table of Contents

DQRID : D100225.2
Start DateStart TimeEnd DateEnd Time
10/06/2008000012/13/20082359
Subject:
HFE/VCEIL/S1 - Incorrect serial_number and sum_backscatter fields
DataStreams:hfevceil25kS1.b1
Description:
Attribute serial_number: In most cases, this field is not representative of the actual 
serial number of the instrument because the value did not change when an instrument changed 
locations or was replaced with a spare.
   
Variable sum_backscatter: An out-of-range condition for the "sum of detected and 
normalized backscatter" was reported as 0 instead of missing (-9999). The valid range is 0 - 
0.0999 /srad.
Measurements:hfevceil25kS1.b1:
  • sum_backscatter


Back To Table of Contents

DQRID : D101122.5
Start DateStart TimeEnd DateEnd Time
05/16/2008000012/28/20082359
Subject:
HFE/QCRAD/M1  - Error in qc fields
DataStreams:hfeqcrad1longM1.c1
Description:
In the qc_down_short_diffuse_hemisp field, QC failures from the test indicated by 
   bit_13: "data failed tracker off test"
were set incorrectly as


In the qc_short_direct_normal field, QC failures from the test indicated by 
   bit_10: "data failed tracker off test"
were set incorrectly as 
   bit_9\: "GSW2SumSW (93 > SZA > 75 and SumSW > 50; GSW/ SumSW < 0.85 or GSW/SumSW > 
1.15)"
Measurements:hfeqcrad1longM1.c1:
  • Radiation, shortwave, direct normal irradiance, 1-min avg(short_direct_normal)
  • Radiation, shortwave, downwelling diffuse hemispheric irradiance, 1-min avg(down_short_diffuse_hemisp)