Data Quality Reports for Session: 140956 User: yanhrong04 Completed: 03/02/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050812.12SGP/THWAPS/C1 - Minor bias in saturation vapor pressuresgpthwapsC1.b1
D080116.24SGP/THWAPS/C1 - RH Data IncorrectsgpthwapsC1.b1
D090211.2SGP/THWAPS/C1 - Barometer intermittentsgpthwapsC1.b1
D090306.1SGP/THWAPS/C1 - Time stamp of data record incorrectsgpthwapsC1.b1
D090824.2SGP/THWAPS/C1 - Wind speed incorrectsgpthwapsC1.b1


DQRID : D050812.12
Start DateStart TimeEnd DateEnd Time
09/21/1999000008/10/20051445
Subject:
SGP/THWAPS/C1 - Minor bias in saturation vapor pressure
DataStreams:sgpthwapsC1.b1
Description:
The saturation vapor correction when temps are below 0C contained an error
in the multiplier.  The incorrect multiplier only equates to an error of
0.01 kPa which is less than the stated uncertainty of the measurement (+/-
0.035 kPa).
Measurements:sgpthwapsC1.b1:
  • Pressure, vapor, 60-m height, 30-min intervals(vap_pres)


Back To Table of Contents

DQRID : D080116.24
Start DateStart TimeEnd DateEnd Time
12/22/2007175012/22/20072130
Subject:
SGP/THWAPS/C1 - RH Data Incorrect
DataStreams:sgpthwapsC1.b1
Description:
The RH data was incorrect during the times listed.  Reason unknown.  The sensor recovered 
on its own.
Measurements:sgpthwapsC1.b1:
  • Pressure, vapor, 60-m height, 30-min intervals(vap_pres)
  • Humidity, relative, 30-min intervals, standard deviation(sd_rh)
  • sd_vap_pres
  • Humidity, relative(rh)


Back To Table of Contents

DQRID : D090211.2
Start DateStart TimeEnd DateEnd Time
01/09/2009000002/13/20092359
Subject:
SGP/THWAPS/C1 - Barometer intermittent
DataStreams:sgpthwapsC1.b1
Description:
Intermittent dropouts on the barometer data were occurring, with data reading low or 
missing.  Loose wiring was the probable culprit.

In most instances, only 1 minute of data was missing. Linear interpolation between the 
last known good point and the first good point following the dropout can be accomplished.
Measurements:sgpthwapsC1.b1:
  • Pressure, atmospheric, constant value of model level, RUC model output(pres)


Back To Table of Contents

DQRID : D090306.1
Start DateStart TimeEnd DateEnd Time
12/09/2008000001/23/20092359
Subject:
SGP/THWAPS/C1 - Time stamp of data record incorrect
DataStreams:sgpthwapsC1.b1
Description:
Due to problems with the collector system, the datalogger was being time synched 
inappropriately.  This problem was intermittent and did not affect every time stamp.  The worst 
case time adjustments were approximately +/- 7 minutes.  These were infrequent and most of 
the time adjustments were less than 7 minutes.
Measurements:sgpthwapsC1.b1:
  • time_offset
  • base_time


Back To Table of Contents

DQRID : D090824.2
Start DateStart TimeEnd DateEnd Time
07/17/2009000011/27/20091745
Subject:
SGP/THWAPS/C1 - Wind speed incorrect
DataStreams:sgpthwapsC1.b1
Description:
The wind sensor was reporting 0 m/s winds for excessive periods of time and appeared to 
measure lower wind speeds than nearby co-located wind sensors.  Sensor was replaced.
Measurements:sgpthwapsC1.b1:
  • Mean Wind Speed(wspd)


Back To Table of Contents